NMW transient search results

This analysis is done by the script util/transients/transient_factory_test31.sh /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp

The list of candidates will appear below. Please manually reload the page every few minutes untill the 'Processing complete' message appears.

Processing fields Dra-04-Q2b1x1

Processing complete!

Total number of candidates identified: 0

FITS images used in this processing run:

Field Dra-04-Q2b1x1 reference image: Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits
Field Dra-04-Q2b1x1 reference image: Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits
Field Dra-04-Q2b1x1 second-epoch image: Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits
Field Dra-04-Q2b1x1 second-epoch image: Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits

Processing log:

Filtering log:

######## Processing parameters ########
AAVSO_COMMENT_STRING= NMW-TexasTech Camera-2 135mm f/2.2 telephoto lens + QHY600M CMOS
ASTCHECK_ASTEROID_SEARCH_RADIUS_ARCSEC= 
BAD_REGION_FILE= /var/www/nmw_calibration/TTUQ2b1x1/TTUQ2_bad_region.lst
CAMERA_SETTINGS= TTUQ2b1x1
CHECK_POINTING_ACCURACY= yes
DARK_FRAMES_DIR_OR_FILE= /var/www/nmw_calibration/TTUQ2b1x1/darks
EXCLUSION_LIST= ../exclusion_list_TTUQ2.txt
FILTER_BAD_IMG__MAX_APERTURE_STAR_SIZE_PIX= 12.5
FILTER_BAD_IMG__MAX_ELONGATION_AminusB_PIX= 0.55
FILTER_BAD_IMG__MIN_APERTURE_STAR_SIZE_PIX= 2.0
FILTER_BRIGHT_MAG_CUTOFF_TRANSIENT_SEARCH= -5
FILTER_FAINT_MAG_CUTOFF_TRANSIENT_SEARCH= 15.5
FLAT_FIELD_DIR_OR_FILE= /var/www/nmw_calibration/TTUQ2b1x1/flats
FRAME_EDGE_OFFSET_PIX= 600
GAIA_BAND_FOR_CATALOGED_SOURCE_CHECK= 
MAX_NEW_TO_REF_MEAN_IMG_VALUE_RATIO= 100
DISABLE_NEW_TO_REF_MEAN_IMG_RATIO_CHECK= yes
MAX_NEW_IMG_MEAN_VALUE= 25000
MAX_SD_RATIO_OF_SECOND_EPOCH_IMGS= 0.18
MAX_SD_RATIO_OF_SECOND_EPOCH_IMGS_SOFT_LIMIT= 0.12
MPC_CODE= V36
NMW_CALIBRATION= /var/www/nmw_calibration
NUMBER_OF_DETECTED_TRANSIENTS_BEFORE_FILTERING_HARD_LIMIT= 10000
NUMBER_OF_DETECTED_TRANSIENTS_BEFORE_FILTERING_SOFT_LIMIT= 8000
OMP_NUM_THREADS= 3
ONLINE_MPCHECKER_BUTTON_ASTEROID_SEARCH_RADIUS_ARCMIN= 
PHOTOMETRIC_CALIBRATION= 
REQUIRE_PIX_SHIFT_BETWEEN_IMAGES_FOR_TRANSIENT_CANDIDATES= yes
SEXTRACTOR_CONFIG_BRIGHTSTARPASS= default.sex.telephoto_lens_onlybrightstars_v1
SEXTRACTOR_CONFIG_FILES= default.sex.telephoto_lens_onlybrightstars_v1 default.sex.telephoto_lens_vSTL
SEXTRACTOR_CONFIG_FILES_HIGH_PRIORITY_EXTRA= default.sex.telephoto_lens_vTTU
HIGH_PRIORITY_FIELDS= Sco6 Oph-08-Q1b1x1 Oph-08-Q2b1x1 Sco-04-Q1b1x1 Sco-04-Q2b1x1 Sgr-04-Q1b1x1 Sgr-04-Q2b1x1 242
STARMATCH_RADIUS_PIX= 5
SYSREM_ITERATIONS= 0
TELESCOP= 
TELESCOP_NAME_KNOWN_TO_VaST_FOR_FOV_DETERMINATION= 
UCAC5_PLATESOLVE_ITERATIONS= 2
FPACK_FULLY_CALIBRATED_IMAGE= no
#######################################
HOSTNAME= tau
USER= 
HOME= 
#######################################
SExtractor catalog cache: enabled, directory /data_ssd/NMW-TexasTech/vast_sextractor_cache
Reference image directory is set to /data_ssd/NMW-TexasTech/reference_imgs
VIZIER_SITE=vizier.cds.unistra.fr
GAIA_DR2_CLIENT=vizquery (lib/vizquery -> VizieR vizier.cds.unistra.fr)
INFO: MAKE_PNG_PLOTS is set to yes
FITS_FILE_EXT=fits
CALIBRATION_STATUS_PREFIX=
Fields in the data directory: 
Dra-04-Q2b1x1
#######################################
########### Starting Dra-04-Q2b1x1 ###########
Processing Dra-04-Q2b1x1
server tau has sufficient free disk space available: 115068 MB at /data_ssd/NMW-TexasTech/workdir
server tau has sufficient free disk space available: 115068 MB at .
Checking input images (2 new)
REFERENCE_EPOCH__FIRST_IMAGE= /data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits
REFERENCE_EPOCH__SECOND_IMAGE= /data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits
Small preview (one of the new images): 
Large previews of the second-epoch (new) images:
MAKE_PNG_PLOTS=yes
renamed 'Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.png' -> 'transient_report/Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits_preview.png'
Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits

renamed 'Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.png' -> 'transient_report/Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits_preview.png'
Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits


Read-check the input FITS images... read-check OK Blank image check the input FITS images... blank-image-check OK Read date check the input FITS images... read-date-check OK Mean value check the input FITS images... OK, at least two new images have mean values below the threshold. ---------------------------------------------- INFO: REFERENCE_EPOCH__FIRST_IMAGE_MEAN_VALUE= 424.1538 INFO: REFERENCE_EPOCH__FIRST_IMAGE_SD= 523.5073 INFO: SECOND_EPOCH__FIRST_IMAGE_MEAN_VALUE= 1098.8918 INFO: SECOND_EPOCH__FIRST_IMAGE_SD= 546.8110 INFO: SECOND_EPOCH__SECOND_IMAGE_MEAN_VALUE= 1099.6501 INFO: SECOND_EPOCH__SECOND_IMAGE_SD= 545.7966 ---------------------------------------------- INFO: ref_to_second_epoch_img_mean_ratio= 2.59079 INFO: SECOND_EPOCH__SD_ratio= 0.002 INFO: the new-to-reference mean image value ratio check is disabled (DISABLE_NEW_TO_REF_MEAN_IMG_RATIO_CHECK=yes) - expected with a background-subtracted reference image ---------------------------------------------- Calibration settings: DARK_FRAMES_DIR_OR_FILE=/var/www/nmw_calibration/TTUQ2b1x1/darks FLAT_FIELD_DIR_OR_FILE=/var/www/nmw_calibration/TTUQ2b1x1/flats EXPTIME = 20.0 / [s] Exposure duration SET-TEMP= 0.0 / [degC] CCD temperature setpoint CCD-TEMP= -0.0 / [degC] CCD temperature FOCTEMP = 27.8199996948242 / [degC] Focuser temperature AMBTEMP = 27.8 / [degC] Ambient air temperature Exploring image header: /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits CCD-TEMP= -0.000000 for /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits SET-TEMP= 0.000000 for /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Header: 74 keys total, 33 keys left Record 0: "" status=0 Record 1: "SIMPLE = T / C# FITS" status=0 Record 2: "BITPIX = 16" status=0 Record 3: "NAXIS = 2 / Dimensionality" status=0 Record 4: "NAXIS1 = 9576" status=0 Record 5: "NAXIS2 = 6388" status=0 Record 6: "BZERO = 32768" status=0 Record 7: "EXTEND = T / Extensions are permitted" status=0 Record 8: "IMAGETYP= 'LIGHT' / Type of exposure" status=0 Record 9: "EXPOSURE= 20.0 / [s] Exposure duration" status=0 Record 10: "EXPTIME = 20.0 / [s] Exposure duration" status=0 Record 11: "DATE-LOC= '2026-09-12T01:16:47.8966097' / Time of observation (local)" status=0 Record 12: "DATE-OBS= '2026-09-12T06:16:47.8966097' / Time of observation (UTC)" status=0 Record 13: "MJD-OBS = 61295.261665463 / Modified Julian Date of observation" status=0 Record 14: "DATE-AVG= '2026-09-12T06:16:57.8020656' / Averaged midpoint time (UTC)" status=0 Record 15: "MJD-AVG = 61295.2617801158 / Modified Julian Date of averaged midpoint" status=0 Record 16: "XBINNING= 1 / X axis binning factor" status=0 Record 17: "YBINNING= 1 / Y axis binning factor" status=0 Record 18: "GAIN = 30 / Sensor gain" status=0 Record 19: "OFFSET = 30 / Sensor gain offset" status=0 Record 20: "XPIXSZ = 3.76 / [um] Pixel X axis size" status=0 Record 21: "YPIXSZ = 3.76 / [um] Pixel Y axis size" status=0 Record 22: "INSTRUME= 'QHY600M' / Imaging instrument name" status=0 Record 23: "CAMERAID= 'QHY600M-84137c4dbbbd119a9' / Imaging instrument identifier" status=0 Record 24: "SET-TEMP= 0.0 / [degC] CCD temperature setpoint" status=0 Record 25: "CCD-TEMP= -0.0 / [degC] CCD temperature" status=0 Record 26: "READOUTM= '2CMS-0' / Sensor readout mode" status=0 Record 27: "USBLIMIT= 50 / Camera-specific USB setting" status=0 Record 28: "TELESCOP= 'QHY600M-TTU2' / Name of telescope" status=0 Record 29: "FOCALLEN= 135.0 / [mm] Focal length" status=0 Record 30: "FOCRATIO= 2.2 / Focal ratio" status=0 Record 31: "RA = 251.996025214695 / [deg] RA of telescope" status=0 Record 32: "DEC = 69.9995910069442 / [deg] Declination of telescope" status=0 Record 33: "CENTALT = 30.9105555555556 / [deg] Altitude of telescope" status=0 Record 34: "CENTAZ = 336.465555555556 / [deg] Azimuth of telescope" status=0 Record 35: "AIRMASS = 1.9414759542946 / Airmass at frame center (Gueymard 1993)" status=0 Record 36: "PIERSIDE= 'East' / Telescope pointing state" status=0 Record 37: "SITEELEV= 1009.5 / [m] Observation site elevation" status=0 Record 38: "SITELAT = 33.7482925 / [deg] Observation site latitude" status=0 Record 39: "SITELONG= -101.958319 / [deg] Observation site longitude" status=0 Record 40: "OBSERVER= 'Sokolovsky' / Observer name" status=0 Record 41: "OBSERVAT= 'TTU Skyview' / Observatory name" status=0 Record 42: "SITENAME= '' / Observatory site name" status=0 Record 43: "FWHEEL = 'Simulator' / Filter Wheel name" status=0 Record 44: "FILTER = 'CV' / Active filter name" status=0 Record 45: "OBJECT = 'Dra-04' / Name of the object of interest" status=0 Record 46: "OBJCTRA = '16 48 00' / [H M S] RA of imaged object" status=0 Record 47: "OBJCTDEC= '+70 00 00' / [D M S] Declination of imaged object" status=0 Record 48: "OBJCTROT= 0.0 / [deg] planned rotation of imaged object" status=0 Record 49: "FOCNAME = 'ZWO Focuser' / Focusing equipment name" status=0 Record 50: "FOCPOS = 20440 / [step] Focuser position" status=0 Record 51: "FOCUSPOS= 20440 / [step] Focuser position" status=0 Record 52: "FOCUSSZ = 0.0 / [um] Focuser step size" status=0 Record 53: "FOCTEMP = 27.8199996948242 / [degC] Focuser temperature" status=0 Record 54: "FOCUSTEM= 27.8199996948242 / [degC] Focuser temperature" status=0 Record 55: "DEWPOINT= 14.4 / [degC] Dew point" status=0 Record 56: "HUMIDITY= 44.0 / [percent] Relative humidity" status=0 Record 57: "PRESSURE= 896.89 / [hPa] Air pressure" status=0 Record 58: "AMBTEMP = 27.8 / [degC] Ambient air temperature" status=0 Record 59: "WINDDIR = 15.0 / [deg] Wind direction: 0=N, 180=S, 90=E, 270=W" status=0 Record 60: "WINDGUST= 22.00176 / [kph] Wind gust" status=0 Record 61: "WINDSPD = 13.701096 / [kph] Wind speed" status=0 Record 62: "ROWORDER= 'TOP-DOWN' / FITS Image Orientation" status=0 Record 63: "EQUINOX = 2000.0 / Equinox of celestial coordinate system" status=0 Record 64: "SWCREATE= 'N.I.N.A. 3.2.0.9001 (x64)' / Software that created this file" status=0 Record 65: "QHY_EXP = 20.000096 / [s] Actual exposure time" status=0 Record 66: "QHY_PP = 13888.0 / [ps] pixelPeriod" status=0 Record 67: "QHY_LP = 85000.0 / [ns] linePeriod" status=0 Record 68: "GPS_LP = 85000.0 / [ns] linePeriod" status=0 Record 69: "QHY_FP = 20000160.0 / [us] framePeriod" status=0 Record 70: "QHY_CPL = 6120.0 / clocksPerLine" status=0 Record 71: "QHY_LPF = 235295.0 / linesPerFrame" status=0 Record 72: "QHY_AET = 20000096.0 / [us] actualExposureTime" status=0 Record 73: "QHY_LEM = T / isLongExposureMode" status=0 Record 74: "QHY_OFF0= 3767.777 / [us] RollingShutterEndOffset row 0" status=0 Allocating memory for image, dark and result arrays... Reading image /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits 9576 6388 16 bitpix SET-TEMP= 0.000000 for /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits SET-TEMP= 0.000000 for /var/www/nmw_calibration/TTUQ2b1x1/darks/mdark_TTUQ2b1x1_0C_20s_2026-08-12_multinight.fit CCD-TEMP= -0.000000 for /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits CCD-TEMP= -0.000000 for /var/www/nmw_calibration/TTUQ2b1x1/darks/mdark_TTUQ2b1x1_0C_20s_2026-08-12_multinight.fit Reading dark frame /var/www/nmw_calibration/TTUQ2b1x1/darks/mdark_TTUQ2b1x1_0C_20s_2026-08-12_multinight.fit 9576 6388 16 bitpix Dark frame is subtracted, output is written to /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/d_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits :) Spent 1.018512 seconds renamed 'mdark_TTUQ2b1x1_0C_20s_2026-08-12_multinight.png' -> 'transient_report/dark.png' try_to_calibrate_the_input_frame(): selected flat field /var/www/nmw_calibration/TTUQ2b1x1/flats/mff_TTUQ2b1x1_2026-08-12_multinight.fit from directory /var/www/nmw_calibration/TTUQ2b1x1/flats MegaDivider v7 Reading image /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/d_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits 9576 6388 16 bitpix Reading flat /var/www/nmw_calibration/TTUQ2b1x1/flats/mff_TTUQ2b1x1_2026-08-12_multinight.fit 9576 6388 16 bitpix Avarage count on flat field image: 37096.658242 Minimal real count (from overscan): 5 Output is written to /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits :) No overscan detected - all values seem high! (left_median=24199.0, right_median=29433.0) renamed 'mff_TTUQ2b1x1_2026-08-12_multinight.png' -> 'transient_report/flat.png' Using calibrated image CALIBRATED_SECOND_EPOCH__FIRST_IMAGE=/data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits EXPTIME = 20.0 / [s] Exposure duration SET-TEMP= 0.0 / [degC] CCD temperature setpoint CCD-TEMP= -0.0 / [degC] CCD temperature FOCTEMP = 27.7900009155273 / [degC] Focuser temperature AMBTEMP = 27.8 / [degC] Ambient air temperature Exploring image header: /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits CCD-TEMP= -0.000000 for /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits SET-TEMP= 0.000000 for /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits Header: 74 keys total, 33 keys left Record 0: "" status=0 Record 1: "SIMPLE = T / C# FITS" status=0 Record 2: "BITPIX = 16" status=0 Record 3: "NAXIS = 2 / Dimensionality" status=0 Record 4: "NAXIS1 = 9576" status=0 Record 5: "NAXIS2 = 6388" status=0 Record 6: "BZERO = 32768" status=0 Record 7: "EXTEND = T / Extensions are permitted" status=0 Record 8: "IMAGETYP= 'LIGHT' / Type of exposure" status=0 Record 9: "EXPOSURE= 20.0 / [s] Exposure duration" status=0 Record 10: "EXPTIME = 20.0 / [s] Exposure duration" status=0 Record 11: "DATE-LOC= '2026-09-12T01:17:33.1908729' / Time of observation (local)" status=0 Record 12: "DATE-OBS= '2026-09-12T06:17:33.1908729' / Time of observation (UTC)" status=0 Record 13: "MJD-OBS = 61295.2621896989 / Modified Julian Date of observation" status=0 Record 14: "DATE-AVG= '2026-09-12T06:17:43.0907950' / Averaged midpoint time (UTC)" status=0 Record 15: "MJD-AVG = 61295.2623042823 / Modified Julian Date of averaged midpoint" status=0 Record 16: "XBINNING= 1 / X axis binning factor" status=0 Record 17: "YBINNING= 1 / Y axis binning factor" status=0 Record 18: "GAIN = 30 / Sensor gain" status=0 Record 19: "OFFSET = 30 / Sensor gain offset" status=0 Record 20: "XPIXSZ = 3.76 / [um] Pixel X axis size" status=0 Record 21: "YPIXSZ = 3.76 / [um] Pixel Y axis size" status=0 Record 22: "INSTRUME= 'QHY600M' / Imaging instrument name" status=0 Record 23: "CAMERAID= 'QHY600M-84137c4dbbbd119a9' / Imaging instrument identifier" status=0 Record 24: "SET-TEMP= 0.0 / [degC] CCD temperature setpoint" status=0 Record 25: "CCD-TEMP= -0.0 / [degC] CCD temperature" status=0 Record 26: "READOUTM= '2CMS-0' / Sensor readout mode" status=0 Record 27: "USBLIMIT= 50 / Camera-specific USB setting" status=0 Record 28: "TELESCOP= 'QHY600M-TTU2' / Name of telescope" status=0 Record 29: "FOCALLEN= 135.0 / [mm] Focal length" status=0 Record 30: "FOCRATIO= 2.2 / Focal ratio" status=0 Record 31: "RA = 251.996025365052 / [deg] RA of telescope" status=0 Record 32: "DEC = 69.9995910109694 / [deg] Declination of telescope" status=0 Record 33: "CENTALT = 30.8466666666667 / [deg] Altitude of telescope" status=0 Record 34: "CENTAZ = 336.484722222222 / [deg] Azimuth of telescope" status=0 Record 35: "AIRMASS = 1.9450729006044 / Airmass at frame center (Gueymard 1993)" status=0 Record 36: "PIERSIDE= 'East' / Telescope pointing state" status=0 Record 37: "SITEELEV= 1009.5 / [m] Observation site elevation" status=0 Record 38: "SITELAT = 33.7482925 / [deg] Observation site latitude" status=0 Record 39: "SITELONG= -101.958319 / [deg] Observation site longitude" status=0 Record 40: "OBSERVER= 'Sokolovsky' / Observer name" status=0 Record 41: "OBSERVAT= 'TTU Skyview' / Observatory name" status=0 Record 42: "SITENAME= '' / Observatory site name" status=0 Record 43: "FWHEEL = 'Simulator' / Filter Wheel name" status=0 Record 44: "FILTER = 'CV' / Active filter name" status=0 Record 45: "OBJECT = 'Dra-04' / Name of the object of interest" status=0 Record 46: "OBJCTRA = '16 48 00' / [H M S] RA of imaged object" status=0 Record 47: "OBJCTDEC= '+70 00 00' / [D M S] Declination of imaged object" status=0 Record 48: "OBJCTROT= 0.0 / [deg] planned rotation of imaged object" status=0 Record 49: "FOCNAME = 'ZWO Focuser' / Focusing equipment name" status=0 Record 50: "FOCPOS = 20440 / [step] Focuser position" status=0 Record 51: "FOCUSPOS= 20440 / [step] Focuser position" status=0 Record 52: "FOCUSSZ = 0.0 / [um] Focuser step size" status=0 Record 53: "FOCTEMP = 27.7900009155273 / [degC] Focuser temperature" status=0 Record 54: "FOCUSTEM= 27.7900009155273 / [degC] Focuser temperature" status=0 Record 55: "DEWPOINT= 14.4 / [degC] Dew point" status=0 Record 56: "HUMIDITY= 44.0 / [percent] Relative humidity" status=0 Record 57: "PRESSURE= 896.89 / [hPa] Air pressure" status=0 Record 58: "AMBTEMP = 27.8 / [degC] Ambient air temperature" status=0 Record 59: "WINDDIR = 15.0 / [deg] Wind direction: 0=N, 180=S, 90=E, 270=W" status=0 Record 60: "WINDGUST= 22.00176 / [kph] Wind gust" status=0 Record 61: "WINDSPD = 13.701096 / [kph] Wind speed" status=0 Record 62: "ROWORDER= 'TOP-DOWN' / FITS Image Orientation" status=0 Record 63: "EQUINOX = 2000.0 / Equinox of celestial coordinate system" status=0 Record 64: "SWCREATE= 'N.I.N.A. 3.2.0.9001 (x64)' / Software that created this file" status=0 Record 65: "QHY_EXP = 20.000096 / [s] Actual exposure time" status=0 Record 66: "QHY_PP = 13888.0 / [ps] pixelPeriod" status=0 Record 67: "QHY_LP = 85000.0 / [ns] linePeriod" status=0 Record 68: "GPS_LP = 85000.0 / [ns] linePeriod" status=0 Record 69: "QHY_FP = 20000160.0 / [us] framePeriod" status=0 Record 70: "QHY_CPL = 6120.0 / clocksPerLine" status=0 Record 71: "QHY_LPF = 235295.0 / linesPerFrame" status=0 Record 72: "QHY_AET = 20000096.0 / [us] actualExposureTime" status=0 Record 73: "QHY_LEM = T / isLongExposureMode" status=0 Record 74: "QHY_OFF0= 3767.777 / [us] RollingShutterEndOffset row 0" status=0 Allocating memory for image, dark and result arrays... Reading image /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits 9576 6388 16 bitpix SET-TEMP= 0.000000 for /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits SET-TEMP= 0.000000 for /var/www/nmw_calibration/TTUQ2b1x1/darks/mdark_TTUQ2b1x1_0C_20s_2026-08-12_multinight.fit CCD-TEMP= -0.000000 for /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits CCD-TEMP= -0.000000 for /var/www/nmw_calibration/TTUQ2b1x1/darks/mdark_TTUQ2b1x1_0C_20s_2026-08-12_multinight.fit Reading dark frame /var/www/nmw_calibration/TTUQ2b1x1/darks/mdark_TTUQ2b1x1_0C_20s_2026-08-12_multinight.fit 9576 6388 16 bitpix Dark frame is subtracted, output is written to /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/d_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits :) Spent 1.143811 seconds renamed 'mdark_TTUQ2b1x1_0C_20s_2026-08-12_multinight.png' -> 'transient_report/dark.png' try_to_calibrate_the_input_frame(): selected flat field /var/www/nmw_calibration/TTUQ2b1x1/flats/mff_TTUQ2b1x1_2026-08-12_multinight.fit from directory /var/www/nmw_calibration/TTUQ2b1x1/flats MegaDivider v7 Reading image /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/d_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits 9576 6388 16 bitpix Reading flat /var/www/nmw_calibration/TTUQ2b1x1/flats/mff_TTUQ2b1x1_2026-08-12_multinight.fit 9576 6388 16 bitpix Avarage count on flat field image: 37096.658242 Minimal real count (from overscan): 5 Output is written to /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits :) No overscan detected - all values seem high! (left_median=24199.0, right_median=29433.0) renamed 'mff_TTUQ2b1x1_2026-08-12_multinight.png' -> 'transient_report/flat.png' Using calibrated image CALIBRATED_SECOND_EPOCH__SECOND_IMAGE=/data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits Dark frame used to calibrate the second-epoch images:

Flat field used to calibrate the second-epoch images:

after the calibration attempt: SECOND_EPOCH__FIRST_IMAGE=/data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits SECOND_EPOCH__SECOND_IMAGE=/data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits Previews of the CALIBRATED second-epoch images:

fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits


fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits


Updating neverexclude_list.txt '/var/www/nmw_calibration/neverexclude_list.txt' -> './neverexclude_list.txt' Choosing bad regions list '/var/www/nmw_calibration/TTUQ2b1x1/TTUQ2_bad_region.lst' -> 'bad_region.lst' wait *------ default.sex.telephoto_lens_onlybrightstars_v1 ------* 'default.sex.telephoto_lens_onlybrightstars_v1' -> 'default.sex' Starting VaST with default.sex.telephoto_lens_onlybrightstars_v1 ./vast --noflagimage --starmatchraius 5 --matchstarnumber 500 --selectbestaperture --sysrem 0 --type 4 --maxsextractorflag 99 --UTC --nofind --nojdkeyword /data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits /data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits SExtractor catalog cache: saved Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits.cat to cache SExtractor catalog cache: saved Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits.cat to cache VaST run complete with default.sex.telephoto_lens_onlybrightstars_v1 The four input images were /data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits /data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits Checking WCS cache directory local_wcs_cache Checking WCS cache directory /mnt/usb/NMW_NG/solved_reference_images Found WCS cache directory /mnt/usb/NMW_NG/solved_reference_images Checking WCS cache directory /home/NMW_web_upload/solved_reference_images Checking WCS cache directory /dataX/kirx/NMW_NG_rt3_autumn2019/solved_reference_images The reference JD(UT) for computing planet and comet positions: 2461295.76178120 Re-using ../asassn_transients_list.txt '../asassn_transients_list.txt' -> 'asassn_transients_list.txt' Re-using ../tocp_transients_list.txt '../tocp_transients_list.txt' -> 'tocp_transients_list.txt' Re-using ../tns_transients_list.txt '../tns_transients_list.txt' -> 'tns_transients_list.txt' Plate-solving the images wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits exists and is non-empty wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits exists and is non-empty wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits exists and is non-empty wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits exists and is non-empty ################################### # fov_of_wcs_calibrated_image.sh output for wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits (1st reference image) verification OK: wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits Image size: 937.4'x624.3' 15.6(deg)x10.4(deg) 9576x6388 pix Image scale: 5.87"/pix along the X axis and 5.86"/pix along the Y axis Image center: 16:47:55.522 +70:01:38.12 J2000 4789.000 3195.000 ################################### The image scale is 5.87"/pix, setting the soft and hard astrometric limits for filtering second-epoch detections: 5.9" and 8.8" ################################### # fov_of_wcs_calibrated_image.sh output for wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits (1st new image) verification OK: wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Image size: 937.4'x623.9' 15.6(deg)x10.4(deg) 9576x6388 pix Image scale: 5.87"/pix along the X axis and 5.86"/pix along the Y axis Image center: 16:48:35.535 +69:56:05.44 J2000 4789.000 3195.000 ################################### ################################### # Check the image center offset between the reference and the first second-epoch image (pointing accuracy) Reference image center 16:47:55.522 +70:01:38.12 Second-epoch image center 16:48:35.535 +69:56:05.44 Angular distance between the image centers 0.1086 deg. Soft limit: 0.50 deg. Hard limit: 1.00 deg. ################################### ################################### # fov_of_wcs_calibrated_image.sh output for wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits (2nd new image) verification OK: wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits Image size: 937.4'x623.9' 15.6(deg)x10.4(deg) 9576x6388 pix Image scale: 5.87"/pix along the X axis and 5.86"/pix along the Y axis Image center: 16:48:32.076 +69:56:45.41 J2000 4789.000 3195.000 ################################### ################################### # Check the image center offset between the reference and the second second-epoch image (pointing accuracy) Reference image center 16:47:55.522 +70:01:38.12 Second-epoch image center 16:48:32.076 +69:56:45.41 Angular distance between the image centers 0.0966 deg. ################################### ################################### # Check the image center offset between the first and the second second-epoch image (shift should be applied between the second-epoch images) Second-epoch first image center 16:48:35.535 +69:56:05.44 Second-epoch second image center 16:48:32.076 +69:56:45.41 Angular distance between the image centers 0.01215 deg. ################################### Running solve_plate_with_UCAC5... Preparing for a parallel run Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits &> /tmp/tmp.9MTx4JmYkO Parallel run for /data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits &> /tmp/tmp.G6gzOvHCJh Parallel run for /data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits &> /tmp/tmp.Y48mVMIaxe Parallel run for /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits &> /tmp/tmp.KenXsupc7A Parallel run for /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits Calibrating the magnitude scale Found non-empty wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits ____ Start of magnitude calibration ____ PHOTOMETRIC_CALIBRATION=TYCHO2_V Calibrating the magnitude scale with Tycho-2 stars util/transients/transient_factory_test31.sh is checking for the presence of non-empty wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits and wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits.wcscat wait (drain background util/solve_plate_with_UCAC5 jobs before Tycho-2 calibration -- avoids wcs_.fits write race) Tycho-2 catalog is found at lib/catalogs/tycho2 Tycho-2 catalog and the derived bright star exclusion list are ready Checking for the presence of non-empty wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits and wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits.wcscat Found non-empty wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits and wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits.wcscat The reference image (wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits) and catalog (wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits.wcscat) found 'wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits.wcscat' -> 'wcsmag.cat' Read 10255 stars from the SExtractor catalog wcsmag.cat Detected star coordinate range: RA 224.3441 to 280.0542 deg, Dec +63.5291 to +75.3009 deg Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.00 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.01 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.02 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.03 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.04 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.05 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.06 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.07 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.08 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.09 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.10 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.11 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.12 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.13 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.14 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.15 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.16 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.17 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.18 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.19 Tycho-2 catalog search boundaries: RA 224.3441 to 280.0542 deg, Dec 63.5291 to 75.3009 deg Loaded 10549 Tycho-2 stars within the image boundaries (VT and BT non-zero). Relation between the catalog and instrumental magnitudes is written to calib.txt Stars used for magnitude calibration (good matches): 6106 out of 6343 total matches. Matched with Tycho-2 6343 out of 10255 detected stars. The calibration function type and coefficients are written to calib.txt_param util/calibrate_magnitude_scale 0.000000 1.000000 22.636500 a=0.000000 b=1.000000 c=22.636500 From vast_summary.log: estimated ref. image limiting mag.: -7.33 Updating vast_summary.log: Estimated ref. image limiting mag.: 15.31 Updated vast_limiting_magnitude.log with calibrated magnitudes Working... Please, PLEASE, be patient!!! All lightcurves processed! =) Estimated ref. image limiting mag.: 15.31
Lightcurve magnitude calibration plot:

Preparing per-reference-image forced-photometry calibration (method=tycho2 band=V) Read 10255 stars from the SExtractor catalog wcsmag.cat Detected star coordinate range: RA 224.3441 to 280.0542 deg, Dec +63.5291 to +75.3009 deg Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.00 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.01 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.02 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.03 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.04 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.05 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.06 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.07 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.08 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.09 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.10 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.11 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.12 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.13 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.14 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.15 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.16 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.17 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.18 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.19 Tycho-2 catalog search boundaries: RA 224.3441 to 280.0542 deg, Dec 63.5291 to 75.3009 deg Loaded 10549 Tycho-2 stars within the image boundaries (VT and BT non-zero). Relation between the catalog and instrumental magnitudes is written to calib.txt Stars used for magnitude calibration (good matches): 6106 out of 6343 total matches. Matched with Tycho-2 6343 out of 10255 detected stars. util/calibrate_single_image_with_tycho2.sh: calibrated wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits via Tycho-2
Single-image forced-photometry magnitude calibration plot for wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits:

Forced-photometry filter: reusing the VaST-run aperture from image00001.cat.aperture for wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits Forced-photometry filter: calibrated wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits -> calib.txt_param_ref_wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits (aperture=6.5) Read 9713 stars from the SExtractor catalog wcsmag.cat Detected star coordinate range: RA 224.3437 to 280.0520 deg, Dec +63.5294 to +75.3010 deg Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.00 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.01 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.02 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.03 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.04 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.05 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.06 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.07 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.08 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.09 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.10 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.11 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.12 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.13 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.14 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.15 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.16 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.17 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.18 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.19 Tycho-2 catalog search boundaries: RA 224.3437 to 280.0520 deg, Dec 63.5294 to 75.3010 deg Loaded 10549 Tycho-2 stars within the image boundaries (VT and BT non-zero). Relation between the catalog and instrumental magnitudes is written to calib.txt Stars used for magnitude calibration (good matches): 6063 out of 6283 total matches. Matched with Tycho-2 6283 out of 9713 detected stars. util/calibrate_single_image_with_tycho2.sh: calibrated wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits via Tycho-2
Single-image forced-photometry magnitude calibration plot for wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits:

Forced-photometry filter: reusing the VaST-run aperture from image00002.cat.aperture for wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits Forced-photometry filter: calibrated wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits -> calib.txt_param_ref_wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits (aperture=6.3) ____ End of magnitude calibration ____ Applying consolidated magnitude filters... Preparing the exclusion lists for this field Done with filtering Found 3 candidate transients before the final filtering. (Hard limit: 10000) Median FWHM seeing for isolated stars: 2.3 pix Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits 2.3 pix Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits 2.5 pix fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits 2.5 pix fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits Limiting magnitude estimates: 15.3 mag. Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits 15.3 mag. Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits 15.1 mag. fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits 15.1 mag. fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits cp: cannot create regular file 'local_wcs_cache/': Not a directory All-image limiting magnitude estimate: 15.1 (SNR ) 12.1 (80% of stars) with default.sex.telephoto_lens_onlybrightstars_v1 The first estimate is the magnitude of a star detected with a signal-to-noise ratio of following Karpov (2025, Acta Polytechnica, 65, 50). This value should be representative of the faintest stars clearly visible in the image. The brighter of the limiting magnitude estimates for the two second-epoch images is reported here. The second estimate is the 80th percentile of the magnitude distribution of stars detected on all four images. This value is representative of the faintest object that may enter the candidate transients list. The hard cut-off for the candidate transients is 15.5 mag. Waiting for UCAC5 plate solver wait ############ /tmp/tmp.9MTx4JmYkO (6) ############ Parsing command line arguments... The guess is based on the existing WCS header. Trying to blindly solve the plate (local solve-field or remote server)... /data_ssd/NMW-TexasTech/workdir/vast_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits 571.0 Entering WCS image calibration mode. ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits verification OK: /data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits It's a known telescope with plate solutions that are supposed to be good. The input image /data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits has a WCS header - will blindly trust it is good... '/data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits' -> 'wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits' This WCS solution (astrometrynet) will be kept as is, not refit by util/solve_plate_with_UCAC5 FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits WCS_IMAGE_NAME=wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits WCS-calibrated image found: wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits Checking if the catalog wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits.wcscat corresponding to the image wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits alredy exist and is non-empty... Catalog wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits.wcscat corresponding to the image wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits found. The catalog is in the new format, as expected. The plate-solved (WCS-calibrated) image is saved to wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits WCS catalog name: wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits.wcscat Excluding image region: -1.0 -1.0 1.0 1.0 (defined in bad_region.lst) Excluding image region: 7500.0 0.0 9576.0 6388.0 (defined in bad_region.lst) Excluding image region: 1122.0 1550.0 1124.0 1552.0 (defined in bad_region.lst) Excluding image region: 1637.0 2824.0 1639.0 2826.0 (defined in bad_region.lst) Excluding image region: 1831.0 2839.0 1833.0 2841.0 (defined in bad_region.lst) Excluding image region: 1905.0 4570.0 1907.0 4572.0 (defined in bad_region.lst) Excluding image region: 2012.0 4693.0 2014.0 4695.0 (defined in bad_region.lst) Excluding image region: 2397.0 4241.0 2399.0 4243.0 (defined in bad_region.lst) Excluding image region: 2679.0 2807.0 2681.0 2809.0 (defined in bad_region.lst) Excluding more image regions!.. (will not print them all) Excluded a total of 31 image regions (defined in bad_region.lst). SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=0, blended=639, bad_region=2049, passed=10255 Got 10255 stars (including 7690 good ones) from the SExtractor catalog wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits.wcscat util/solve_plate_with_UCAC5 got 10255 stars from the SExtractor catalog Updated FoV from the plate-solved image: 937.4' Seting catalog search parameters based on the expected field of view 937.4 arcmin UCAC5 catalog search parameters: catalog_search_parameters->search_radius_deg= 0.013019 (46.9 arcsec) catalog_search_parameters->brightest_mag= 1.00 catalog_search_parameters->faintest_mag= 13.50 catalog_search_parameters->search_radius_second_step_deg 0.010416 (37.5 arcsec) ITERATION 01 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50 Reading UCAC5 zone files... Searching UCAC5 zones 767 to 828 (Dec 63.5 to 75.3) Done reading UCAC5 zone files... Matched 4893 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Correcting the measured astrometric positions... Accuracy estimation diagnostic: 4883 matched stars entering correct_measured_positions(), 4883 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.32" Removing outliers... Correcting the measured astrometric positions... Accuracy estimation diagnostic: 4883 matched stars entering correct_measured_positions(), 8625 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.32" ITERATION 02 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50 Reading UCAC5 zone files... Searching UCAC5 zones 767 to 828 (Dec 63.5 to 75.3) Done reading UCAC5 zone files... Matched 4894 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Accuracy estimation diagnostic: 4883 matched stars entering correct_measured_positions(), 8625 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.33" Accuracy estimation diagnostic: 4883 matched stars entering correct_measured_positions(), 8625 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.34" Excluding outliers - 4883 stars left (next iteration limit 5371) Stop iterations. The field is successfully solved and matched with the astrometric catalog! :) SIP_REFIT: util/identify.sh trusts the WCS of wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits (astrometrynet) - keeping it, no refit (set VAST_FORCE_SIP_REFIT=1 to refit anyway) WCS_QUALITY_DIAG: file=Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits N_match=4883 sigma_overall_arcsec=0.357 sigma_q1_arcsec=0.308 sigma_q2_arcsec=0.387 sigma_q3_arcsec=0.423 sigma_q4_arcsec=0.345 n_q1=1682 n_q2=915 n_q3=1541 n_q4=745 worst_quadrant_to_overall_ratio=1.184 The image catalog is written to wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits.wcscat.ucac5 The DS9 region file with the matched stars is written to wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits.wcscat.ds9.reg You may view it with the command: ds9 /data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits -region wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits.wcscat.ds9.reg The astrometric residuals vector field is written to wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits.wcscat.astrometric_residuals Option '-n' not using photometric catalogs, just stick with astrometry opt '-i': 2 is the maximum number of iterations FORCED_PHOTOMETRY_CALIBRATION_METHOD=tycho2 - not using remote photometric catalogs, just stick with astrometry ############ /tmp/tmp.G6gzOvHCJh (6) ############ Parsing command line arguments... The guess is based on the existing WCS header. Trying to blindly solve the plate (local solve-field or remote server)... /data_ssd/NMW-TexasTech/workdir/vast_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits 571.0 Entering WCS image calibration mode. ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits verification OK: /data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits It's a known telescope with plate solutions that are supposed to be good. The input image /data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits has a WCS header - will blindly trust it is good... '/data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits' -> 'wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits' This WCS solution (astrometrynet) will be kept as is, not refit by util/solve_plate_with_UCAC5 FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits WCS_IMAGE_NAME=wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits WCS-calibrated image found: wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits Checking if the catalog wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits.wcscat corresponding to the image wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits alredy exist and is non-empty... Catalog wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits.wcscat corresponding to the image wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits found. The catalog is in the new format, as expected. The plate-solved (WCS-calibrated) image is saved to wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits WCS catalog name: wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits.wcscat Excluding image region: -1.0 -1.0 1.0 1.0 (defined in bad_region.lst) Excluding image region: 7500.0 0.0 9576.0 6388.0 (defined in bad_region.lst) Excluding image region: 1122.0 1550.0 1124.0 1552.0 (defined in bad_region.lst) Excluding image region: 1637.0 2824.0 1639.0 2826.0 (defined in bad_region.lst) Excluding image region: 1831.0 2839.0 1833.0 2841.0 (defined in bad_region.lst) Excluding image region: 1905.0 4570.0 1907.0 4572.0 (defined in bad_region.lst) Excluding image region: 2012.0 4693.0 2014.0 4695.0 (defined in bad_region.lst) Excluding image region: 2397.0 4241.0 2399.0 4243.0 (defined in bad_region.lst) Excluding image region: 2679.0 2807.0 2681.0 2809.0 (defined in bad_region.lst) Excluding more image regions!.. (will not print them all) Excluded a total of 31 image regions (defined in bad_region.lst). SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=0, blended=583, bad_region=1827, passed=9713 Got 9713 stars (including 7378 good ones) from the SExtractor catalog wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits.wcscat util/solve_plate_with_UCAC5 got 9713 stars from the SExtractor catalog Updated FoV from the plate-solved image: 937.3' Seting catalog search parameters based on the expected field of view 937.3 arcmin UCAC5 catalog search parameters: catalog_search_parameters->search_radius_deg= 0.013018 (46.9 arcsec) catalog_search_parameters->brightest_mag= 1.00 catalog_search_parameters->faintest_mag= 13.50 catalog_search_parameters->search_radius_second_step_deg 0.010414 (37.5 arcsec) ITERATION 01 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50 Reading UCAC5 zone files... Searching UCAC5 zones 767 to 828 (Dec 63.5 to 75.3) Done reading UCAC5 zone files... Matched 4895 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Correcting the measured astrometric positions... Accuracy estimation diagnostic: 4886 matched stars entering correct_measured_positions(), 4886 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.35" Removing outliers... Correcting the measured astrometric positions... Accuracy estimation diagnostic: 4886 matched stars entering correct_measured_positions(), 8254 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.35" ITERATION 02 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50 Reading UCAC5 zone files... Searching UCAC5 zones 767 to 828 (Dec 63.5 to 75.3) Done reading UCAC5 zone files... Matched 4896 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Accuracy estimation diagnostic: 4886 matched stars entering correct_measured_positions(), 8254 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.36" Accuracy estimation diagnostic: 4886 matched stars entering correct_measured_positions(), 8254 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.37" Excluding outliers - 4886 stars left (next iteration limit 5374) Stop iterations. The field is successfully solved and matched with the astrometric catalog! :) SIP_REFIT: util/identify.sh trusts the WCS of wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits (astrometrynet) - keeping it, no refit (set VAST_FORCE_SIP_REFIT=1 to refit anyway) WCS_QUALITY_DIAG: file=Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits N_match=4886 sigma_overall_arcsec=0.407 sigma_q1_arcsec=0.367 sigma_q2_arcsec=0.403 sigma_q3_arcsec=0.478 sigma_q4_arcsec=0.371 n_q1=1697 n_q2=870 n_q3=1587 n_q4=732 worst_quadrant_to_overall_ratio=1.174 The image catalog is written to wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits.wcscat.ucac5 The DS9 region file with the matched stars is written to wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits.wcscat.ds9.reg You may view it with the command: ds9 /data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits -region wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits.wcscat.ds9.reg The astrometric residuals vector field is written to wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits.wcscat.astrometric_residuals Option '-n' not using photometric catalogs, just stick with astrometry opt '-i': 2 is the maximum number of iterations FORCED_PHOTOMETRY_CALIBRATION_METHOD=tycho2 - not using remote photometric catalogs, just stick with astrometry ############ /tmp/tmp.Y48mVMIaxe (6) ############ Parsing command line arguments... The minor axis of the CCD chip should be 24.0 mm based on the derived pixel size of 3.8 um Internal estimated FoV 605.3' The guess is based on the FOCALLEN keyword. Trying to blindly solve the plate (local solve-field or remote server)... /data_ssd/NMW-TexasTech/workdir/vast_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits 605.0 Entering WCS image calibration mode. ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits verification OK: /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits It's not one of the telescopes that are know to produce images with good WCS solutions - will try to re-solve! FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits WCS_IMAGE_NAME=wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits WCS-calibrated image found: wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Checking if the catalog wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits.wcscat corresponding to the image wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits alredy exist and is non-empty... Catalog wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits.wcscat corresponding to the image wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits found. The catalog is in the new format, as expected. The plate-solved (WCS-calibrated) image is saved to wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits WCS catalog name: wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits.wcscat Excluding image region: -1.0 -1.0 1.0 1.0 (defined in bad_region.lst) Excluding image region: 7500.0 0.0 9576.0 6388.0 (defined in bad_region.lst) Excluding image region: 1122.0 1550.0 1124.0 1552.0 (defined in bad_region.lst) Excluding image region: 1637.0 2824.0 1639.0 2826.0 (defined in bad_region.lst) Excluding image region: 1831.0 2839.0 1833.0 2841.0 (defined in bad_region.lst) Excluding image region: 1905.0 4570.0 1907.0 4572.0 (defined in bad_region.lst) Excluding image region: 2012.0 4693.0 2014.0 4695.0 (defined in bad_region.lst) Excluding image region: 2397.0 4241.0 2399.0 4243.0 (defined in bad_region.lst) Excluding image region: 2679.0 2807.0 2681.0 2809.0 (defined in bad_region.lst) Excluding more image regions!.. (will not print them all) Excluded a total of 31 image regions (defined in bad_region.lst). SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=0, blended=607, bad_region=1237, passed=8914 Got 8914 stars (including 7272 good ones) from the SExtractor catalog wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits.wcscat util/solve_plate_with_UCAC5 got 8914 stars from the SExtractor catalog Updated FoV from the plate-solved image: 937.4' Seting catalog search parameters based on the expected field of view 937.4 arcmin UCAC5 catalog search parameters: catalog_search_parameters->search_radius_deg= 0.013019 (46.9 arcsec) catalog_search_parameters->brightest_mag= 1.00 catalog_search_parameters->faintest_mag= 13.50 catalog_search_parameters->search_radius_second_step_deg 0.010416 (37.5 arcsec) ITERATION 01 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50 Reading UCAC5 zone files... Searching UCAC5 zones 768 to 827 (Dec 63.6 to 75.2) Done reading UCAC5 zone files... Matched 4893 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Correcting the measured astrometric positions... Accuracy estimation diagnostic: 4881 matched stars entering correct_measured_positions(), 4881 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.32" Removing outliers... Correcting the measured astrometric positions... Accuracy estimation diagnostic: 4881 matched stars entering correct_measured_positions(), 7966 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.32" ITERATION 02 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50 Reading UCAC5 zone files... Searching UCAC5 zones 768 to 827 (Dec 63.6 to 75.2) Done reading UCAC5 zone files... Matched 4892 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Accuracy estimation diagnostic: 4881 matched stars entering correct_measured_positions(), 7966 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.34" Accuracy estimation diagnostic: 4881 matched stars entering correct_measured_positions(), 7966 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.34" Excluding outliers - 4881 stars left (next iteration limit 5369) Stop iterations. The field is successfully solved and matched with the astrometric catalog! :) SIP_REFIT: SIP order 2 trial: matched=4881 robust_rms=5.937 arcsec worst_quadrant_rms=11.915 arcsec SIP_REFIT: SIP order 3 trial: matched=4881 robust_rms=0.391 arcsec worst_quadrant_rms=0.438 arcsec SIP_REFIT: SIP order 5 trial: matched=4881 robust_rms=0.338 arcsec worst_quadrant_rms=0.421 arcsec SIP_REFIT: selected SIP order 3 SIP_REFIT: order=3 matched=4881 robust_rms_before=0.612 arcsec robust_rms_before_corrected=0.341 arcsec robust_rms_after=0.391 arcsec worst_quadrant_rms_before=0.437 worst_quadrant_rms_after=0.438 SIP_REFIT: refit does not sufficiently improve on the solution it would replace (best worst-quadrant baseline 0.437 arcsec) - keeping the original WCS_QUALITY_DIAG: file=fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits N_match=4881 sigma_overall_arcsec=0.325 sigma_q1_arcsec=0.298 sigma_q2_arcsec=0.340 sigma_q3_arcsec=0.361 sigma_q4_arcsec=0.481 n_q1=1735 n_q2=800 n_q3=1671 n_q4=675 worst_quadrant_to_overall_ratio=1.479 The image catalog is written to wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits.wcscat.ucac5 The DS9 region file with the matched stars is written to wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits.wcscat.ds9.reg You may view it with the command: ds9 /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits -region wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits.wcscat.ds9.reg The astrometric residuals vector field is written to wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits.wcscat.astrometric_residuals Option '-n' not using photometric catalogs, just stick with astrometry opt '-i': 2 is the maximum number of iterations FORCED_PHOTOMETRY_CALIBRATION_METHOD=tycho2 - not using remote photometric catalogs, just stick with astrometry ############ /tmp/tmp.KenXsupc7A (6) ############ Parsing command line arguments... The minor axis of the CCD chip should be 24.0 mm based on the derived pixel size of 3.8 um Internal estimated FoV 605.3' The guess is based on the FOCALLEN keyword. Trying to blindly solve the plate (local solve-field or remote server)... /data_ssd/NMW-TexasTech/workdir/vast_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits 605.0 Entering WCS image calibration mode. ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits verification OK: /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits It's not one of the telescopes that are know to produce images with good WCS solutions - will try to re-solve! FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits WCS_IMAGE_NAME=wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits WCS-calibrated image found: wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits Checking if the catalog wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits.wcscat corresponding to the image wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits alredy exist and is non-empty... Catalog wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits.wcscat corresponding to the image wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits found. The catalog is in the new format, as expected. The plate-solved (WCS-calibrated) image is saved to wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits WCS catalog name: wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits.wcscat Excluding image region: -1.0 -1.0 1.0 1.0 (defined in bad_region.lst) Excluding image region: 7500.0 0.0 9576.0 6388.0 (defined in bad_region.lst) Excluding image region: 1122.0 1550.0 1124.0 1552.0 (defined in bad_region.lst) Excluding image region: 1637.0 2824.0 1639.0 2826.0 (defined in bad_region.lst) Excluding image region: 1831.0 2839.0 1833.0 2841.0 (defined in bad_region.lst) Excluding image region: 1905.0 4570.0 1907.0 4572.0 (defined in bad_region.lst) Excluding image region: 2012.0 4693.0 2014.0 4695.0 (defined in bad_region.lst) Excluding image region: 2397.0 4241.0 2399.0 4243.0 (defined in bad_region.lst) Excluding image region: 2679.0 2807.0 2681.0 2809.0 (defined in bad_region.lst) Excluding more image regions!.. (will not print them all) Excluded a total of 31 image regions (defined in bad_region.lst). SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=0, blended=607, bad_region=1230, passed=8903 Got 8903 stars (including 7254 good ones) from the SExtractor catalog wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits.wcscat util/solve_plate_with_UCAC5 got 8903 stars from the SExtractor catalog Updated FoV from the plate-solved image: 937.4' Seting catalog search parameters based on the expected field of view 937.4 arcmin UCAC5 catalog search parameters: catalog_search_parameters->search_radius_deg= 0.013019 (46.9 arcsec) catalog_search_parameters->brightest_mag= 1.00 catalog_search_parameters->faintest_mag= 13.50 catalog_search_parameters->search_radius_second_step_deg 0.010416 (37.5 arcsec) ITERATION 01 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50 Reading UCAC5 zone files... Searching UCAC5 zones 768 to 827 (Dec 63.7 to 75.2) Done reading UCAC5 zone files... Matched 4887 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Correcting the measured astrometric positions... Accuracy estimation diagnostic: 4874 matched stars entering correct_measured_positions(), 4874 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.31" Removing outliers... Correcting the measured astrometric positions... Accuracy estimation diagnostic: 4874 matched stars entering correct_measured_positions(), 7960 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.32" ITERATION 02 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50 Reading UCAC5 zone files... Searching UCAC5 zones 768 to 827 (Dec 63.7 to 75.2) Done reading UCAC5 zone files... Matched 4887 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Accuracy estimation diagnostic: 4874 matched stars entering correct_measured_positions(), 7960 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.33" Accuracy estimation diagnostic: 4874 matched stars entering correct_measured_positions(), 7960 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.34" Excluding outliers - 4874 stars left (next iteration limit 5361) Stop iterations. The field is successfully solved and matched with the astrometric catalog! :) SIP_REFIT: SIP order 2 trial: matched=4874 robust_rms=5.943 arcsec worst_quadrant_rms=11.893 arcsec SIP_REFIT: SIP order 3 trial: matched=4874 robust_rms=0.396 arcsec worst_quadrant_rms=0.447 arcsec SIP_REFIT: SIP order 5 trial: matched=4874 robust_rms=0.344 arcsec worst_quadrant_rms=0.455 arcsec SIP_REFIT: selected SIP order 3 SIP_REFIT: order=3 matched=4874 robust_rms_before=0.616 arcsec robust_rms_before_corrected=0.340 arcsec robust_rms_after=0.396 arcsec worst_quadrant_rms_before=0.442 worst_quadrant_rms_after=0.447 SIP_REFIT: refit does not sufficiently improve on the solution it would replace (best worst-quadrant baseline 0.442 arcsec) - keeping the original WCS_QUALITY_DIAG: file=fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits N_match=4874 sigma_overall_arcsec=0.327 sigma_q1_arcsec=0.308 sigma_q2_arcsec=0.328 sigma_q3_arcsec=0.359 sigma_q4_arcsec=0.468 n_q1=1716 n_q2=798 n_q3=1687 n_q4=673 worst_quadrant_to_overall_ratio=1.434 The image catalog is written to wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits.wcscat.ucac5 The DS9 region file with the matched stars is written to wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits.wcscat.ds9.reg You may view it with the command: ds9 /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits -region wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits.wcscat.ds9.reg The astrometric residuals vector field is written to wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits.wcscat.astrometric_residuals Option '-n' not using photometric catalogs, just stick with astrometry opt '-i': 2 is the maximum number of iterations FORCED_PHOTOMETRY_CALIBRATION_METHOD=tycho2 - not using remote photometric catalogs, just stick with astrometry Saving the final (post-refit) wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits to local_wcs_cache/ 'wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits' -> 'local_wcs_cache/wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits' Saving the final (post-refit) wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits to local_wcs_cache/ 'wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits' -> 'local_wcs_cache/wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits' Saving the final (post-refit) wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits to local_wcs_cache/ 'wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits' -> 'local_wcs_cache/wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits' Saving the final (post-refit) wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits to local_wcs_cache/ 'wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits' -> 'local_wcs_cache/wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits' ################################### # Pre-local-correction WCS quality summary (see WCS_QUALITY_DIAG lines above) ref1=Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits sigma_overall=0.357 worst_q_ratio=1.184 ref2=Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits sigma_overall=0.407 worst_q_ratio=1.174 new1=fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits sigma_overall=0.325 worst_q_ratio=1.479 new2=fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits sigma_overall=0.327 worst_q_ratio=1.434 reference average sigma_overall=0.382 worst_q_ratio=1.179 warn-on-ratio threshold: 2.0x reference ###################################
Astrometric residual vector field (catalog-matched stars):
plot_astrometric_residuals_xy.py: wrote wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262_astrometric_residuals.png (4883 matched stars from wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits.wcscat.astrometric_residuals, image 9576x6388, median residual 0.32 arcsec)
plot_astrometric_residuals_xy.py: wrote wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188_astrometric_residuals.png (4886 matched stars from wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits.wcscat.astrometric_residuals, image 9576x6388, median residual 0.36 arcsec)
plot_astrometric_residuals_xy.py: wrote wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294_astrometric_residuals.png (4881 matched stars from wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits.wcscat.astrometric_residuals, image 9576x6388, median residual 0.30 arcsec)
plot_astrometric_residuals_xy.py: wrote wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295_astrometric_residuals.png (4874 matched stars from wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits.wcscat.astrometric_residuals, image 9576x6388, median residual 0.30 arcsec)
Copying WCS-calibrated images back to input directory Saving fully-calibrated image wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits INFO: FPACK_FULLY_CALIBRATED_IMAGE=no (not compressing the image) 'wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits' -> '/data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits' Saving fully-calibrated image wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits INFO: FPACK_FULLY_CALIBRATED_IMAGE=no (not compressing the image) 'wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits' -> '/data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits' Preparing the HTML report for the field Dra-04-Q2b1x1 with default.sex.telephoto_lens_onlybrightstars_v1 Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:08:32.99 +70:16:20.5: 12.23 +/- 0.01 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:08:32.99 +70:16:20.5: 12.24 +/- 0.01 detection Forced photometry reference-image weighted average: 12.23 +/- 0.01 Forced photometry filter REJECTED candidate at 17:08:32.99 +70:16:20.5: ref_mag=12.23 +/- 0.01 new_mean_mag=12.2762 delta=-0.04 (need > 0.90) make_report_in_HTML.sh Phase 1 (network queries): 5s Pre-generating preview images in parallel... Done pre-generating preview images. Pre-generating finding charts in parallel... Done pre-generating finding charts. make_report_in_HTML.sh Pre-generation: 1s xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 20372_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 20372_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 2   2026 09 12.26231    2461295.76231    11.59    17:04:04.83 +71:47:44.9   4054 2054   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits **** FOUND 17:04:04.81 +71:47:44.6 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 20407_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 20407_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 2   2026 09 12.26231    2461295.76231    11.98    17:02:24.23 +66:18:56.8   3949 5371   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits **** FOUND 17:02:24.22 +66:18:57.0 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 20432_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 20432_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    12.28    17:08:33.00 +70:16:20.7   3772 2951   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    12.28    17:08:32.99 +70:16:20.4   3769 2958   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits make_report_in_HTML.sh Phase 2 (HTML assembly): 0s make_report_in_HTML.sh TOTAL: 6s Prepared the HTML report for the field Dra-04-Q2b1x1 with default.sex.telephoto_lens_onlybrightstars_v1 *------ done with default.sex.telephoto_lens_onlybrightstars_v1 ------* #### The local exclusion list is exclusion_list_local.txt #### wait *------ default.sex.telephoto_lens_vSTL ------* 'default.sex.telephoto_lens_vSTL' -> 'default.sex' Starting VaST with default.sex.telephoto_lens_vSTL ./vast --noflagimage --starmatchraius 5 --matchstarnumber 500 --selectbestaperture --sysrem 0 --type 4 --maxsextractorflag 99 --UTC --nofind --nojdkeyword /data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits /data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits SExtractor catalog cache: saved Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits.cat to cache SExtractor catalog cache: saved Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits.cat to cache VaST run complete with default.sex.telephoto_lens_vSTL The four input images were /data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits /data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits Checking WCS cache directory local_wcs_cache Found WCS cache directory local_wcs_cache Creating symlink local_wcs_cache/wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits Creating symlink local_wcs_cache/wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits Creating symlink local_wcs_cache/wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Creating symlink local_wcs_cache/wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits Checking WCS cache directory /mnt/usb/NMW_NG/solved_reference_images Found WCS cache directory /mnt/usb/NMW_NG/solved_reference_images Checking WCS cache directory /home/NMW_web_upload/solved_reference_images Checking WCS cache directory /dataX/kirx/NMW_NG_rt3_autumn2019/solved_reference_images Plate-solving the images wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits exists and is non-empty wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits exists and is non-empty wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits exists and is non-empty wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits exists and is non-empty ################################### # fov_of_wcs_calibrated_image.sh output for wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits (1st reference image) verification OK: wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits Image size: 937.4'x624.3' 15.6(deg)x10.4(deg) 9576x6388 pix Image scale: 5.87"/pix along the X axis and 5.86"/pix along the Y axis Image center: 16:47:55.522 +70:01:38.12 J2000 4789.000 3195.000 ################################### The image scale is 5.87"/pix, setting the soft and hard astrometric limits for filtering second-epoch detections: 5.9" and 8.8" ################################### # fov_of_wcs_calibrated_image.sh output for wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits (1st new image) verification OK: wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Image size: 937.4'x623.9' 15.6(deg)x10.4(deg) 9576x6388 pix Image scale: 5.87"/pix along the X axis and 5.86"/pix along the Y axis Image center: 16:48:35.535 +69:56:05.44 J2000 4789.000 3195.000 ################################### ################################### # Check the image center offset between the reference and the first second-epoch image (pointing accuracy) Reference image center 16:47:55.522 +70:01:38.12 Second-epoch image center 16:48:35.535 +69:56:05.44 Angular distance between the image centers 0.1086 deg. Soft limit: 0.50 deg. Hard limit: 1.00 deg. ################################### ################################### # fov_of_wcs_calibrated_image.sh output for wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits (2nd new image) verification OK: wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits Image size: 937.4'x623.9' 15.6(deg)x10.4(deg) 9576x6388 pix Image scale: 5.87"/pix along the X axis and 5.86"/pix along the Y axis Image center: 16:48:32.076 +69:56:45.41 J2000 4789.000 3195.000 ################################### ################################### # Check the image center offset between the reference and the second second-epoch image (pointing accuracy) Reference image center 16:47:55.522 +70:01:38.12 Second-epoch image center 16:48:32.076 +69:56:45.41 Angular distance between the image centers 0.0966 deg. ################################### ################################### # Check the image center offset between the first and the second second-epoch image (shift should be applied between the second-epoch images) Second-epoch first image center 16:48:35.535 +69:56:05.44 Second-epoch second image center 16:48:32.076 +69:56:45.41 Angular distance between the image centers 0.01215 deg. ################################### Running solve_plate_with_UCAC5... Preparing for a parallel run Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits &> /tmp/tmp.KO54hAhCRH Parallel run for /data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits &> /tmp/tmp.XMzbkyNIQI Parallel run for /data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits &> /tmp/tmp.1iKFopNsXL Parallel run for /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits &> /tmp/tmp.DtP0T7OACR Parallel run for /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits Calibrating the magnitude scale Found non-empty wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits ____ Start of magnitude calibration ____ PHOTOMETRIC_CALIBRATION=TYCHO2_V Calibrating the magnitude scale with Tycho-2 stars util/transients/transient_factory_test31.sh is checking for the presence of non-empty wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits and wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits.wcscat wait (drain background util/solve_plate_with_UCAC5 jobs before Tycho-2 calibration -- avoids wcs_.fits write race) Tycho-2 catalog is found at lib/catalogs/tycho2 Tycho-2 catalog and the derived bright star exclusion list are ready Checking for the presence of non-empty wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits and wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits.wcscat Found non-empty wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits and wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits.wcscat The reference image (wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits) and catalog (wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits.wcscat) found 'wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits.wcscat' -> 'wcsmag.cat' Read 59001 stars from the SExtractor catalog wcsmag.cat Detected star coordinate range: RA 223.8682 to 280.2840 deg, Dec +63.5166 to +75.3036 deg Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.00 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.01 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.02 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.03 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.04 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.05 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.06 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.07 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.08 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.09 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.10 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.11 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.12 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.13 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.14 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.15 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.16 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.17 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.18 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.19 Tycho-2 catalog search boundaries: RA 223.8682 to 280.2840 deg, Dec 63.5166 to 75.3036 deg Loaded 10684 Tycho-2 stars within the image boundaries (VT and BT non-zero). Relation between the catalog and instrumental magnitudes is written to calib.txt Stars used for magnitude calibration (good matches): 5760 out of 6510 total matches. Matched with Tycho-2 6510 out of 59001 detected stars. The calibration function type and coefficients are written to calib.txt_param util/calibrate_magnitude_scale 0.000000 1.000000 22.499400 a=0.000000 b=1.000000 c=22.499400 From vast_summary.log: estimated ref. image limiting mag.: -7.01 Updating vast_summary.log: Estimated ref. image limiting mag.: 15.49 Updated vast_limiting_magnitude.log with calibrated magnitudes Working... Please, PLEASE, be patient!!! All lightcurves processed! =) Estimated ref. image limiting mag.: 15.49
Lightcurve magnitude calibration plot:

Preparing per-reference-image forced-photometry calibration (method=tycho2 band=V) Read 59001 stars from the SExtractor catalog wcsmag.cat Detected star coordinate range: RA 223.8682 to 280.2840 deg, Dec +63.5166 to +75.3036 deg Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.00 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.01 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.02 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.03 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.04 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.05 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.06 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.07 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.08 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.09 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.10 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.11 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.12 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.13 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.14 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.15 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.16 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.17 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.18 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.19 Tycho-2 catalog search boundaries: RA 223.8682 to 280.2840 deg, Dec 63.5166 to 75.3036 deg Loaded 10684 Tycho-2 stars within the image boundaries (VT and BT non-zero). Relation between the catalog and instrumental magnitudes is written to calib.txt Stars used for magnitude calibration (good matches): 5760 out of 6510 total matches. Matched with Tycho-2 6510 out of 59001 detected stars. util/calibrate_single_image_with_tycho2.sh: calibrated wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits via Tycho-2
Single-image forced-photometry magnitude calibration plot for wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits:

Forced-photometry filter: reusing the VaST-run aperture from image00001.cat.aperture for wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits Forced-photometry filter: calibrated wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits -> calib.txt_param_ref_wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits (aperture=4.9) Read 57363 stars from the SExtractor catalog wcsmag.cat Detected star coordinate range: RA 223.8668 to 280.2819 deg, Dec +63.5294 to +75.3037 deg Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.00 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.01 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.02 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.03 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.04 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.05 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.06 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.07 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.08 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.09 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.10 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.11 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.12 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.13 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.14 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.15 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.16 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.17 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.18 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.19 Tycho-2 catalog search boundaries: RA 223.8668 to 280.2819 deg, Dec 63.5294 to 75.3037 deg Loaded 10672 Tycho-2 stars within the image boundaries (VT and BT non-zero). Relation between the catalog and instrumental magnitudes is written to calib.txt Stars used for magnitude calibration (good matches): 5834 out of 6504 total matches. Matched with Tycho-2 6504 out of 57363 detected stars. util/calibrate_single_image_with_tycho2.sh: calibrated wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits via Tycho-2
Single-image forced-photometry magnitude calibration plot for wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits:

Forced-photometry filter: reusing the VaST-run aperture from image00002.cat.aperture for wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits Forced-photometry filter: calibrated wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits -> calib.txt_param_ref_wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits (aperture=4.8) ____ End of magnitude calibration ____ Applying consolidated magnitude filters... Preparing the exclusion lists for this field Done with filtering Found 74 candidate transients before the final filtering. (Hard limit: 10000) Median FWHM seeing for isolated stars: 2.1 pix Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits 2.1 pix Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits 2.4 pix fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits 2.5 pix fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits Limiting magnitude estimates: 15.5 mag. Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits 15.4 mag. Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits 15.2 mag. fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits 15.2 mag. fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits All-image limiting magnitude estimate: 15.2 (SNR ) 14.4 (80% of stars) with default.sex.telephoto_lens_vSTL The first estimate is the magnitude of a star detected with a signal-to-noise ratio of following Karpov (2025, Acta Polytechnica, 65, 50). This value should be representative of the faintest stars clearly visible in the image. The brighter of the limiting magnitude estimates for the two second-epoch images is reported here. The second estimate is the 80th percentile of the magnitude distribution of stars detected on all four images. This value is representative of the faintest object that may enter the candidate transients list. The hard cut-off for the candidate transients is 15.5 mag. Waiting for UCAC5 plate solver wait ############ /tmp/tmp.KO54hAhCRH (6) ############ Parsing command line arguments... The guess is based on the existing WCS header. Trying to blindly solve the plate (local solve-field or remote server)... /data_ssd/NMW-TexasTech/workdir/vast_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits 571.0 Entering WCS image calibration mode. ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits verification OK: /data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits It's a known telescope with plate solutions that are supposed to be good. The input image /data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits has a WCS header - will blindly trust it is good... '/data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits' -> 'wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits' This WCS solution (astrometrynet) will be kept as is, not refit by util/solve_plate_with_UCAC5 FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits WCS_IMAGE_NAME=wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits WCS-calibrated image found: wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits Checking if the catalog wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits.wcscat corresponding to the image wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits alredy exist and is non-empty... Catalog wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits.wcscat corresponding to the image wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits found. The catalog is in the new format, as expected. The plate-solved (WCS-calibrated) image is saved to wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits WCS catalog name: wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits.wcscat Excluding image region: -1.0 -1.0 1.0 1.0 (defined in bad_region.lst) Excluding image region: 7500.0 0.0 9576.0 6388.0 (defined in bad_region.lst) Excluding image region: 1122.0 1550.0 1124.0 1552.0 (defined in bad_region.lst) Excluding image region: 1637.0 2824.0 1639.0 2826.0 (defined in bad_region.lst) Excluding image region: 1831.0 2839.0 1833.0 2841.0 (defined in bad_region.lst) Excluding image region: 1905.0 4570.0 1907.0 4572.0 (defined in bad_region.lst) Excluding image region: 2012.0 4693.0 2014.0 4695.0 (defined in bad_region.lst) Excluding image region: 2397.0 4241.0 2399.0 4243.0 (defined in bad_region.lst) Excluding image region: 2679.0 2807.0 2681.0 2809.0 (defined in bad_region.lst) Excluding more image regions!.. (will not print them all) Excluded a total of 31 image regions (defined in bad_region.lst). SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=31, blended=3328, bad_region=9570, passed=58970 Got 58970 stars (including 46512 good ones) from the SExtractor catalog wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits.wcscat util/solve_plate_with_UCAC5 got 58970 stars from the SExtractor catalog Updated FoV from the plate-solved image: 937.4' Seting catalog search parameters based on the expected field of view 937.4 arcmin UCAC5 catalog search parameters: catalog_search_parameters->search_radius_deg= 0.013019 (46.9 arcsec) catalog_search_parameters->brightest_mag= 1.00 catalog_search_parameters->faintest_mag= 13.50 catalog_search_parameters->search_radius_second_step_deg 0.010416 (37.5 arcsec) ITERATION 01 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50 Reading UCAC5 zone files... Searching UCAC5 zones 767 to 828 (Dec 63.5 to 75.3) Done reading UCAC5 zone files... Matched 4885 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Correcting the measured astrometric positions... Accuracy estimation diagnostic: 4877 matched stars entering correct_measured_positions(), 4877 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.32" Removing outliers... Correcting the measured astrometric positions... Accuracy estimation diagnostic: 4877 matched stars entering correct_measured_positions(), 51842 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.33" ITERATION 02 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50 Reading UCAC5 zone files... Searching UCAC5 zones 767 to 828 (Dec 63.5 to 75.3) Done reading UCAC5 zone files... Matched 4885 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Accuracy estimation diagnostic: 4877 matched stars entering correct_measured_positions(), 51842 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.33" Accuracy estimation diagnostic: 4877 matched stars entering correct_measured_positions(), 51842 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.35" Excluding outliers - 4877 stars left (next iteration limit 5364) Stop iterations. The field is successfully solved and matched with the astrometric catalog! :) SIP_REFIT: wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits is a symbolic link - will not rewrite the WCS of whatever it points to, but will still refit the output catalog positions SIP_REFIT: util/identify.sh trusts the WCS of wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits (astrometrynet) - keeping it, no refit (set VAST_FORCE_SIP_REFIT=1 to refit anyway) WCS_QUALITY_DIAG: file=Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits N_match=4877 sigma_overall_arcsec=0.359 sigma_q1_arcsec=0.313 sigma_q2_arcsec=0.373 sigma_q3_arcsec=0.424 sigma_q4_arcsec=0.341 n_q1=1709 n_q2=919 n_q3=1490 n_q4=759 worst_quadrant_to_overall_ratio=1.182 The image catalog is written to wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits.wcscat.ucac5 The DS9 region file with the matched stars is written to wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits.wcscat.ds9.reg You may view it with the command: ds9 /data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits -region wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits.wcscat.ds9.reg The astrometric residuals vector field is written to wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits.wcscat.astrometric_residuals Option '-n' not using photometric catalogs, just stick with astrometry opt '-i': 2 is the maximum number of iterations FORCED_PHOTOMETRY_CALIBRATION_METHOD=tycho2 - not using remote photometric catalogs, just stick with astrometry ############ /tmp/tmp.XMzbkyNIQI (6) ############ Parsing command line arguments... The guess is based on the existing WCS header. Trying to blindly solve the plate (local solve-field or remote server)... /data_ssd/NMW-TexasTech/workdir/vast_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits 571.0 Entering WCS image calibration mode. ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits verification OK: /data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits It's a known telescope with plate solutions that are supposed to be good. The input image /data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits has a WCS header - will blindly trust it is good... '/data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits' -> 'wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits' This WCS solution (astrometrynet) will be kept as is, not refit by util/solve_plate_with_UCAC5 FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits WCS_IMAGE_NAME=wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits WCS-calibrated image found: wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits Checking if the catalog wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits.wcscat corresponding to the image wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits alredy exist and is non-empty... Catalog wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits.wcscat corresponding to the image wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits found. The catalog is in the new format, as expected. The plate-solved (WCS-calibrated) image is saved to wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits WCS catalog name: wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits.wcscat Excluding image region: -1.0 -1.0 1.0 1.0 (defined in bad_region.lst) Excluding image region: 7500.0 0.0 9576.0 6388.0 (defined in bad_region.lst) Excluding image region: 1122.0 1550.0 1124.0 1552.0 (defined in bad_region.lst) Excluding image region: 1637.0 2824.0 1639.0 2826.0 (defined in bad_region.lst) Excluding image region: 1831.0 2839.0 1833.0 2841.0 (defined in bad_region.lst) Excluding image region: 1905.0 4570.0 1907.0 4572.0 (defined in bad_region.lst) Excluding image region: 2012.0 4693.0 2014.0 4695.0 (defined in bad_region.lst) Excluding image region: 2397.0 4241.0 2399.0 4243.0 (defined in bad_region.lst) Excluding image region: 2679.0 2807.0 2681.0 2809.0 (defined in bad_region.lst) Excluding more image regions!.. (will not print them all) Excluded a total of 31 image regions (defined in bad_region.lst). SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=29, blended=2985, bad_region=8505, passed=57334 Got 57334 stars (including 46234 good ones) from the SExtractor catalog wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits.wcscat util/solve_plate_with_UCAC5 got 57334 stars from the SExtractor catalog Updated FoV from the plate-solved image: 937.3' Seting catalog search parameters based on the expected field of view 937.3 arcmin UCAC5 catalog search parameters: catalog_search_parameters->search_radius_deg= 0.013018 (46.9 arcsec) catalog_search_parameters->brightest_mag= 1.00 catalog_search_parameters->faintest_mag= 13.50 catalog_search_parameters->search_radius_second_step_deg 0.010414 (37.5 arcsec) ITERATION 01 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50 Reading UCAC5 zone files... Searching UCAC5 zones 767 to 828 (Dec 63.5 to 75.3) Done reading UCAC5 zone files... Matched 4884 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Correcting the measured astrometric positions... Accuracy estimation diagnostic: 4878 matched stars entering correct_measured_positions(), 4878 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.35" Removing outliers... Correcting the measured astrometric positions... Accuracy estimation diagnostic: 4878 matched stars entering correct_measured_positions(), 51019 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.35" ITERATION 02 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50 Reading UCAC5 zone files... Searching UCAC5 zones 767 to 828 (Dec 63.5 to 75.3) Done reading UCAC5 zone files... Matched 4884 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Accuracy estimation diagnostic: 4878 matched stars entering correct_measured_positions(), 51019 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.36" Accuracy estimation diagnostic: 4878 matched stars entering correct_measured_positions(), 51018 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.38" Excluding outliers - 4878 stars left (next iteration limit 5365) Stop iterations. The field is successfully solved and matched with the astrometric catalog! :) SIP_REFIT: wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits is a symbolic link - will not rewrite the WCS of whatever it points to, but will still refit the output catalog positions SIP_REFIT: util/identify.sh trusts the WCS of wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits (astrometrynet) - keeping it, no refit (set VAST_FORCE_SIP_REFIT=1 to refit anyway) WCS_QUALITY_DIAG: file=Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits N_match=4878 sigma_overall_arcsec=0.399 sigma_q1_arcsec=0.366 sigma_q2_arcsec=0.392 sigma_q3_arcsec=0.482 sigma_q4_arcsec=0.366 n_q1=1725 n_q2=869 n_q3=1544 n_q4=740 worst_quadrant_to_overall_ratio=1.206 The image catalog is written to wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits.wcscat.ucac5 The DS9 region file with the matched stars is written to wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits.wcscat.ds9.reg You may view it with the command: ds9 /data_ssd/NMW-TexasTech/reference_imgs/Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits -region wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits.wcscat.ds9.reg The astrometric residuals vector field is written to wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits.wcscat.astrometric_residuals Option '-n' not using photometric catalogs, just stick with astrometry opt '-i': 2 is the maximum number of iterations FORCED_PHOTOMETRY_CALIBRATION_METHOD=tycho2 - not using remote photometric catalogs, just stick with astrometry ############ /tmp/tmp.1iKFopNsXL (6) ############ Parsing command line arguments... The minor axis of the CCD chip should be 24.0 mm based on the derived pixel size of 3.8 um Internal estimated FoV 605.3' The guess is based on the FOCALLEN keyword. Trying to blindly solve the plate (local solve-field or remote server)... /data_ssd/NMW-TexasTech/workdir/vast_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits 605.0 Entering WCS image calibration mode. ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits verification OK: /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits It's not one of the telescopes that are know to produce images with good WCS solutions - will try to re-solve! FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits WCS_IMAGE_NAME=wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits WCS-calibrated image found: wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Checking if the catalog wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits.wcscat corresponding to the image wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits alredy exist and is non-empty... Catalog wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits.wcscat corresponding to the image wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits found. The catalog is in the new format, as expected. The plate-solved (WCS-calibrated) image is saved to wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits WCS catalog name: wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits.wcscat Excluding image region: -1.0 -1.0 1.0 1.0 (defined in bad_region.lst) Excluding image region: 7500.0 0.0 9576.0 6388.0 (defined in bad_region.lst) Excluding image region: 1122.0 1550.0 1124.0 1552.0 (defined in bad_region.lst) Excluding image region: 1637.0 2824.0 1639.0 2826.0 (defined in bad_region.lst) Excluding image region: 1831.0 2839.0 1833.0 2841.0 (defined in bad_region.lst) Excluding image region: 1905.0 4570.0 1907.0 4572.0 (defined in bad_region.lst) Excluding image region: 2012.0 4693.0 2014.0 4695.0 (defined in bad_region.lst) Excluding image region: 2397.0 4241.0 2399.0 4243.0 (defined in bad_region.lst) Excluding image region: 2679.0 2807.0 2681.0 2809.0 (defined in bad_region.lst) Excluding more image regions!.. (will not print them all) Excluded a total of 31 image regions (defined in bad_region.lst). SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=15, blended=3263, bad_region=4731, passed=45194 Got 45194 stars (including 38477 good ones) from the SExtractor catalog wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits.wcscat util/solve_plate_with_UCAC5 got 45194 stars from the SExtractor catalog Updated FoV from the plate-solved image: 937.4' Seting catalog search parameters based on the expected field of view 937.4 arcmin UCAC5 catalog search parameters: catalog_search_parameters->search_radius_deg= 0.013019 (46.9 arcsec) catalog_search_parameters->brightest_mag= 1.00 catalog_search_parameters->faintest_mag= 13.50 catalog_search_parameters->search_radius_second_step_deg 0.010416 (37.5 arcsec) ITERATION 01 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50 Reading UCAC5 zone files... Searching UCAC5 zones 768 to 827 (Dec 63.6 to 75.2) Done reading UCAC5 zone files... Matched 4885 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Correcting the measured astrometric positions... Accuracy estimation diagnostic: 4873 matched stars entering correct_measured_positions(), 4873 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.32" Removing outliers... Correcting the measured astrometric positions... Accuracy estimation diagnostic: 4873 matched stars entering correct_measured_positions(), 41627 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.32" ITERATION 02 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50 Reading UCAC5 zone files... Searching UCAC5 zones 768 to 827 (Dec 63.6 to 75.2) Done reading UCAC5 zone files... Matched 4884 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Accuracy estimation diagnostic: 4873 matched stars entering correct_measured_positions(), 41627 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.32" Accuracy estimation diagnostic: 4873 matched stars entering correct_measured_positions(), 41627 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.34" Excluding outliers - 4873 stars left (next iteration limit 5360) Stop iterations. The field is successfully solved and matched with the astrometric catalog! :) SIP_REFIT: wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits is a symbolic link - will not rewrite the WCS of whatever it points to, but will still refit the output catalog positions SIP_REFIT: SIP order 2 trial: matched=4873 robust_rms=5.771 arcsec worst_quadrant_rms=13.214 arcsec SIP_REFIT: SIP order 3 trial: matched=4873 robust_rms=0.395 arcsec worst_quadrant_rms=0.441 arcsec SIP_REFIT: SIP order 5 trial: matched=4873 robust_rms=0.342 arcsec worst_quadrant_rms=0.415 arcsec SIP_REFIT: selected SIP order 5 SIP_REFIT: order=5 matched=4873 robust_rms_before=0.614 arcsec robust_rms_before_corrected=0.343 arcsec robust_rms_after=0.342 arcsec worst_quadrant_rms_before=0.441 worst_quadrant_rms_after=0.415 SIP_REFIT: refit does not sufficiently improve on the solution it would replace (best worst-quadrant baseline 0.441 arcsec) - keeping the original WCS_QUALITY_DIAG: file=fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits N_match=4873 sigma_overall_arcsec=0.323 sigma_q1_arcsec=0.295 sigma_q2_arcsec=0.345 sigma_q3_arcsec=0.359 sigma_q4_arcsec=0.485 n_q1=1748 n_q2=757 n_q3=1705 n_q4=663 worst_quadrant_to_overall_ratio=1.499 The image catalog is written to wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits.wcscat.ucac5 The DS9 region file with the matched stars is written to wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits.wcscat.ds9.reg You may view it with the command: ds9 /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits -region wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits.wcscat.ds9.reg The astrometric residuals vector field is written to wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits.wcscat.astrometric_residuals Option '-n' not using photometric catalogs, just stick with astrometry opt '-i': 2 is the maximum number of iterations FORCED_PHOTOMETRY_CALIBRATION_METHOD=tycho2 - not using remote photometric catalogs, just stick with astrometry ############ /tmp/tmp.DtP0T7OACR (6) ############ Parsing command line arguments... The minor axis of the CCD chip should be 24.0 mm based on the derived pixel size of 3.8 um Internal estimated FoV 605.3' The guess is based on the FOCALLEN keyword. Trying to blindly solve the plate (local solve-field or remote server)... /data_ssd/NMW-TexasTech/workdir/vast_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits 605.0 Entering WCS image calibration mode. ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits verification OK: /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits It's not one of the telescopes that are know to produce images with good WCS solutions - will try to re-solve! FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits WCS_IMAGE_NAME=wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits WCS-calibrated image found: wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits Checking if the catalog wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits.wcscat corresponding to the image wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits alredy exist and is non-empty... Catalog wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits.wcscat corresponding to the image wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits found. The catalog is in the new format, as expected. The plate-solved (WCS-calibrated) image is saved to wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits WCS catalog name: wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits.wcscat Excluding image region: -1.0 -1.0 1.0 1.0 (defined in bad_region.lst) Excluding image region: 7500.0 0.0 9576.0 6388.0 (defined in bad_region.lst) Excluding image region: 1122.0 1550.0 1124.0 1552.0 (defined in bad_region.lst) Excluding image region: 1637.0 2824.0 1639.0 2826.0 (defined in bad_region.lst) Excluding image region: 1831.0 2839.0 1833.0 2841.0 (defined in bad_region.lst) Excluding image region: 1905.0 4570.0 1907.0 4572.0 (defined in bad_region.lst) Excluding image region: 2012.0 4693.0 2014.0 4695.0 (defined in bad_region.lst) Excluding image region: 2397.0 4241.0 2399.0 4243.0 (defined in bad_region.lst) Excluding image region: 2679.0 2807.0 2681.0 2809.0 (defined in bad_region.lst) Excluding more image regions!.. (will not print them all) Excluded a total of 31 image regions (defined in bad_region.lst). SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=3, blended=3173, bad_region=4715, passed=44819 Got 44819 stars (including 38140 good ones) from the SExtractor catalog wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits.wcscat util/solve_plate_with_UCAC5 got 44819 stars from the SExtractor catalog Updated FoV from the plate-solved image: 937.4' Seting catalog search parameters based on the expected field of view 937.4 arcmin UCAC5 catalog search parameters: catalog_search_parameters->search_radius_deg= 0.013019 (46.9 arcsec) catalog_search_parameters->brightest_mag= 1.00 catalog_search_parameters->faintest_mag= 13.50 catalog_search_parameters->search_radius_second_step_deg 0.010416 (37.5 arcsec) ITERATION 01 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50 Reading UCAC5 zone files... Searching UCAC5 zones 768 to 827 (Dec 63.6 to 75.2) Done reading UCAC5 zone files... Matched 4881 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Correcting the measured astrometric positions... Accuracy estimation diagnostic: 4872 matched stars entering correct_measured_positions(), 4872 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.31" Removing outliers... Correcting the measured astrometric positions... Accuracy estimation diagnostic: 4872 matched stars entering correct_measured_positions(), 41273 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.32" ITERATION 02 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50 Reading UCAC5 zone files... Searching UCAC5 zones 768 to 827 (Dec 63.6 to 75.2) Done reading UCAC5 zone files... Matched 4881 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Accuracy estimation diagnostic: 4872 matched stars entering correct_measured_positions(), 41273 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.32" Accuracy estimation diagnostic: 4872 matched stars entering correct_measured_positions(), 41273 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.33" Excluding outliers - 4872 stars left (next iteration limit 5359) Stop iterations. The field is successfully solved and matched with the astrometric catalog! :) SIP_REFIT: wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits is a symbolic link - will not rewrite the WCS of whatever it points to, but will still refit the output catalog positions SIP_REFIT: SIP order 2 trial: matched=4872 robust_rms=5.812 arcsec worst_quadrant_rms=13.179 arcsec SIP_REFIT: SIP order 3 trial: matched=4872 robust_rms=0.403 arcsec worst_quadrant_rms=0.452 arcsec SIP_REFIT: SIP order 5 trial: matched=4872 robust_rms=0.347 arcsec worst_quadrant_rms=0.448 arcsec SIP_REFIT: selected SIP order 3 SIP_REFIT: order=3 matched=4872 robust_rms_before=0.617 arcsec robust_rms_before_corrected=0.342 arcsec robust_rms_after=0.403 arcsec worst_quadrant_rms_before=0.436 worst_quadrant_rms_after=0.452 SIP_REFIT: refit does not sufficiently improve on the solution it would replace (best worst-quadrant baseline 0.436 arcsec) - keeping the original WCS_QUALITY_DIAG: file=fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits N_match=4872 sigma_overall_arcsec=0.328 sigma_q1_arcsec=0.304 sigma_q2_arcsec=0.325 sigma_q3_arcsec=0.360 sigma_q4_arcsec=0.460 n_q1=1743 n_q2=764 n_q3=1700 n_q4=665 worst_quadrant_to_overall_ratio=1.401 The image catalog is written to wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits.wcscat.ucac5 The DS9 region file with the matched stars is written to wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits.wcscat.ds9.reg You may view it with the command: ds9 /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits -region wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits.wcscat.ds9.reg The astrometric residuals vector field is written to wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits.wcscat.astrometric_residuals Option '-n' not using photometric catalogs, just stick with astrometry opt '-i': 2 is the maximum number of iterations FORCED_PHOTOMETRY_CALIBRATION_METHOD=tycho2 - not using remote photometric catalogs, just stick with astrometry Skipping WCS quality comparison: not the first SExtractor pass (default.sex.telephoto_lens_vSTL) Copying WCS-calibrated images back to input directory Saving fully-calibrated image wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits INFO: FPACK_FULLY_CALIBRATED_IMAGE=no (not compressing the image) The destination file is already there - not rewriting /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Saving fully-calibrated image wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits INFO: FPACK_FULLY_CALIBRATED_IMAGE=no (not compressing the image) The destination file is already there - not rewriting /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/wcs_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits Preparing the HTML report for the field Dra-04-Q2b1x1 with default.sex.telephoto_lens_vSTL Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:37:25.32 +66:26:59.6: 14.66 +/- 0.12 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:47:35.42 +69:28:24.5: 14.34 +/- 0.08 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:45:22.54 +70:57:14.3: 14.28 +/- 0.08 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:43:19.31 +71:17:29.8: 14.60 +/- 0.10 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:18:14.26 +66:52:31.8: 14.69 +/- 0.11 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:31:49.31 +68:10:36.0: 11.88 +/- 0.01 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 16:58:15.70 +67:28:42.5: 13.99 +/- 0.06 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:16:09.22 +69:00:07.1: 14.27 +/- 0.07 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:47:59.89 +66:04:16.8: 12.41 +/- 0.02 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 18:08:05.61 +69:46:05.6: 12.57 +/- 0.02 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:45:22.54 +70:57:14.3: 14.23 +/- 0.08 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:16:09.22 +69:00:07.1: 14.40 +/- 0.09 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 16:58:15.70 +67:28:42.5: 13.88 +/- 0.05 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:47:35.42 +69:28:24.5: 14.56 +/- 0.11 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:47:59.89 +66:04:16.8: 12.37 +/- 0.02 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:18:14.26 +66:52:31.8: 14.78 +/- 0.13 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:31:49.31 +68:10:36.0: 11.82 +/- 0.01 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:43:19.31 +71:17:29.8: 14.85 +/- 0.14 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 18:08:05.61 +69:46:05.6: 12.52 +/- 0.02 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:37:25.32 +66:26:59.6: 14.54 +/- 0.12 detection Forced photometry reference-image weighted average: 13.93 +/- 0.04 Forced photometry reference-image weighted average: 11.85 +/- 0.01 Forced photometry reference-image weighted average: 14.26 +/- 0.06 Forced photometry reference-image weighted average: 14.41 +/- 0.06 Forced photometry reference-image weighted average: 14.73 +/- 0.09 Forced photometry reference-image weighted average: 14.68 +/- 0.08 Forced photometry reference-image weighted average: 14.32 +/- 0.06 Forced photometry reference-image weighted average: 12.54 +/- 0.01 Forced photometry reference-image weighted average: 14.60 +/- 0.08 Forced photometry filter REJECTED candidate at 16:58:15.70 +67:28:42.5: ref_mag=13.93 +/- 0.04 new_mean_mag=14.1390 delta=-0.21 (need > 0.90) Forced photometry filter REJECTED candidate at 17:31:49.31 +68:10:36.0: ref_mag=11.85 +/- 0.01 new_mean_mag=11.8724 delta=-0.02 (need > 0.90) Forced photometry filter REJECTED candidate at 17:47:35.42 +69:28:24.5: ref_mag=14.41 +/- 0.06 new_mean_mag=14.5254 delta=-0.11 (need > 0.90) Forced photometry filter REJECTED candidate at 17:43:19.31 +71:17:29.8: ref_mag=14.68 +/- 0.08 new_mean_mag=14.5556 delta=0.13 (need > 0.90) Forced photometry filter REJECTED candidate at 17:18:14.26 +66:52:31.8: ref_mag=14.73 +/- 0.09 new_mean_mag=14.4229 delta=0.31 (need > 0.90) Forced photometry filter REJECTED candidate at 17:45:22.54 +70:57:14.3: ref_mag=14.26 +/- 0.06 new_mean_mag=14.2063 delta=0.05 (need > 0.90) Forced photometry filter REJECTED candidate at 17:16:09.22 +69:00:07.1: ref_mag=14.32 +/- 0.06 new_mean_mag=14.3769 delta=-0.06 (need > 0.90) Forced photometry reference-image weighted average: 12.39 +/- 0.01 Forced photometry filter REJECTED candidate at 17:37:25.32 +66:26:59.6: ref_mag=14.60 +/- 0.08 new_mean_mag=14.6622 delta=-0.06 (need > 0.90) Forced photometry filter REJECTED candidate at 18:08:05.61 +69:46:05.6: ref_mag=12.54 +/- 0.01 new_mean_mag=12.6875 delta=-0.14 (need > 0.90) Forced photometry filter REJECTED candidate at 17:47:59.89 +66:04:16.8: ref_mag=12.39 +/- 0.01 new_mean_mag=12.6293 delta=-0.24 (need > 0.90) Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 18:06:17.52 +68:58:52.9: 13.71 +/- 0.05 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 16:56:44.37 +67:26:13.1: 12.95 +/- 0.02 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:45:23.79 +65:40:39.0: 13.62 +/- 0.05 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:48:23.12 +69:06:49.4: 12.95 +/- 0.02 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 16:30:24.26 +67:20:17.2: 13.95 +/- 0.06 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 16:52:36.90 +71:05:07.7: 13.82 +/- 0.05 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:39:00.81 +68:13:06.6: 14.05 +/- 0.07 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:49:56.21 +66:11:06.6: 13.85 +/- 0.06 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 16:52:36.90 +71:05:07.7: 13.86 +/- 0.06 detection Forced photometry reference-image weighted average: 13.84 +/- 0.04 Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:48:23.12 +69:06:49.4: 12.86 +/- 0.03 detection Forced photometry filter REJECTED candidate at 16:52:36.90 +71:05:07.7: ref_mag=13.84 +/- 0.04 new_mean_mag=13.8641 delta=-0.03 (need > 0.90) Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:39:00.81 +68:13:06.6: 13.95 +/- 0.07 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:45:23.79 +65:40:39.0: 13.60 +/- 0.06 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:49:56.21 +66:11:06.6: 13.84 +/- 0.06 detection Forced photometry reference-image weighted average: 14.00 +/- 0.05 Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 16:30:24.26 +67:20:17.2: 13.92 +/- 0.06 detection Forced photometry reference-image weighted average: 12.91 +/- 0.02 Forced photometry reference-image weighted average: 13.61 +/- 0.04 Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 18:06:17.52 +68:58:52.9: 13.79 +/- 0.06 detection Forced photometry filter REJECTED candidate at 17:39:00.81 +68:13:06.6: ref_mag=14.00 +/- 0.05 new_mean_mag=14.0091 delta=-0.01 (need > 0.90) Forced photometry filter REJECTED candidate at 17:48:23.12 +69:06:49.4: ref_mag=12.91 +/- 0.02 new_mean_mag=13.0483 delta=-0.14 (need > 0.90) Forced photometry filter REJECTED candidate at 17:45:23.79 +65:40:39.0: ref_mag=13.61 +/- 0.04 new_mean_mag=13.8886 delta=-0.28 (need > 0.90) Forced photometry reference-image weighted average: 13.85 +/- 0.04 Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:48:37.30 +65:41:44.3: 14.75 +/- 0.13 detection Forced photometry filter REJECTED candidate at 17:49:56.21 +66:11:06.6: ref_mag=13.85 +/- 0.04 new_mean_mag=14.1522 delta=-0.31 (need > 0.90) Forced photometry reference-image weighted average: 13.74 +/- 0.04 Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 16:56:44.37 +67:26:13.1: 12.95 +/- 0.02 detection Forced photometry reference-image weighted average: 13.94 +/- 0.04 Forced photometry filter REJECTED candidate at 18:06:17.52 +68:58:52.9: ref_mag=13.74 +/- 0.04 new_mean_mag=13.8806 delta=-0.14 (need > 0.90) Forced photometry filter REJECTED candidate at 16:30:24.26 +67:20:17.2: ref_mag=13.94 +/- 0.04 new_mean_mag=13.9728 delta=-0.04 (need > 0.90) Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:38:02.16 +67:36:37.1: 14.08 +/- 0.07 detection Forced photometry reference-image weighted average: 12.95 +/- 0.02 Forced photometry filter REJECTED candidate at 16:56:44.37 +67:26:13.1: ref_mag=12.95 +/- 0.02 new_mean_mag=12.9762 delta=-0.03 (need > 0.90) Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:48:37.30 +65:41:44.3: 14.68 +/- 0.14 detection Forced photometry reference-image weighted average: 14.72 +/- 0.10 Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:38:02.16 +67:36:37.1: 14.27 +/- 0.09 detection Forced photometry filter REJECTED candidate at 17:48:37.30 +65:41:44.3: ref_mag=14.72 +/- 0.10 new_mean_mag=14.4736 delta=0.25 (need > 0.90) Forced photometry reference-image weighted average: 14.14 +/- 0.05 Forced photometry filter REJECTED candidate at 17:38:02.16 +67:36:37.1: ref_mag=14.14 +/- 0.05 new_mean_mag=14.3340 delta=-0.19 (need > 0.90) Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:25:36.15 +65:56:52.6: 14.76 +/- 0.13 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:43:46.85 +65:21:30.6: 14.78 +/- 0.14 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:58:40.19 +69:27:22.9: 14.71 +/- 0.13 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:43:09.91 +65:29:49.5: 14.72 +/- 0.14 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:42:15.18 +68:20:54.7: 14.86 +/- 0.13 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 18:03:03.96 +69:23:52.6: 14.74 +/- 0.13 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:25:36.15 +65:56:52.6: 14.53 +/- 0.12 detection Forced photometry reference-image weighted average: 14.63 +/- 0.09 Forced photometry filter REJECTED candidate at 17:25:36.15 +65:56:52.6: ref_mag=14.63 +/- 0.09 new_mean_mag=14.6070 delta=0.03 (need > 0.90) Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:43:46.85 +65:21:30.6: 14.66 +/- 0.14 detection Forced photometry reference-image weighted average: 14.72 +/- 0.10 Forced photometry filter REJECTED candidate at 17:43:46.85 +65:21:30.6: ref_mag=14.72 +/- 0.10 new_mean_mag=14.5976 delta=0.13 (need > 0.90) Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 18:03:03.96 +69:23:52.6: 14.77 +/- 0.15 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:58:40.19 +69:27:22.9: 14.68 +/- 0.14 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:43:09.91 +65:29:49.5: 14.82 +/- 0.17 detection Forced photometry reference-image weighted average: 14.76 +/- 0.10 Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:42:15.18 +68:20:54.7: 14.51 +/- 0.11 detection Forced photometry reference-image weighted average: 14.69 +/- 0.10 Forced photometry reference-image weighted average: 14.76 +/- 0.11 Forced photometry filter REJECTED candidate at 17:58:40.19 +69:27:22.9: ref_mag=14.69 +/- 0.10 new_mean_mag=14.4104 delta=0.28 (need > 0.90) Forced photometry filter REJECTED candidate at 18:03:03.96 +69:23:52.6: ref_mag=14.76 +/- 0.10 new_mean_mag=14.6151 delta=0.14 (need > 0.90) Forced photometry filter REJECTED candidate at 17:43:09.91 +65:29:49.5: ref_mag=14.76 +/- 0.11 new_mean_mag=14.5715 delta=0.19 (need > 0.90) Forced photometry reference-image weighted average: 14.65 +/- 0.08 Forced photometry filter REJECTED candidate at 17:42:15.18 +68:20:54.7: ref_mag=14.65 +/- 0.08 new_mean_mag=14.4576 delta=0.19 (need > 0.90) Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:46:59.88 +68:36:35.5: 14.70 +/- 0.12 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:53:13.90 +69:31:36.9: 14.67 +/- 0.12 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:44:15.14 +66:42:51.9: 14.84 +/- 0.13 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:35:58.73 +66:15:29.3: 14.49 +/- 0.09 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:46:59.88 +68:36:35.5: 14.56 +/- 0.12 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:53:13.90 +69:31:36.9: 14.76 +/- 0.14 detection Forced photometry reference-image weighted average: 14.63 +/- 0.09 Forced photometry filter REJECTED candidate at 17:46:59.88 +68:36:35.5: ref_mag=14.63 +/- 0.09 new_mean_mag=14.5206 delta=0.11 (need > 0.90) Forced photometry reference-image weighted average: 14.71 +/- 0.09 Forced photometry filter REJECTED candidate at 17:53:13.90 +69:31:36.9: ref_mag=14.71 +/- 0.09 new_mean_mag=14.5321 delta=0.18 (need > 0.90) Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:35:58.73 +66:15:29.3: 14.60 +/- 0.12 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:44:15.14 +66:42:51.9: 14.92 +/- 0.17 detection Forced photometry reference-image weighted average: 14.53 +/- 0.07 Forced photometry reference-image weighted average: 14.87 +/- 0.11 Forced photometry filter REJECTED candidate at 17:35:58.73 +66:15:29.3: ref_mag=14.53 +/- 0.07 new_mean_mag=14.5139 delta=0.02 (need > 0.90) Forced photometry filter REJECTED candidate at 17:44:15.14 +66:42:51.9: ref_mag=14.87 +/- 0.11 new_mean_mag=14.7306 delta=0.14 (need > 0.90) Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 16:54:59.11 +65:46:45.4: 14.55 +/- 0.10 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:52:20.60 +65:30:29.4: 14.51 +/- 0.11 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:51:11.16 +67:15:20.3: 15.20 +/- 0.20 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:50:05.75 +65:10:58.3: 14.87 +/- 0.16 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:25:22.53 +65:30:52.0: 14.89 +/- 0.14 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:49:23.47 +65:20:38.5: 14.83 +/- 0.14 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:52:20.60 +65:30:29.4: 14.38 +/- 0.11 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:49:32.41 +66:54:14.6: 15.14 +/- 0.18 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 16:54:59.11 +65:46:45.4: 14.46 +/- 0.10 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:50:05.75 +65:10:58.3: 14.55 +/- 0.14 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:51:11.16 +67:15:20.3: 15.45 +/- 0.28 detection Forced photometry reference-image weighted average: 14.45 +/- 0.08 Forced photometry filter REJECTED candidate at 17:52:20.60 +65:30:29.4: ref_mag=14.45 +/- 0.08 new_mean_mag=14.7138 delta=-0.27 (need > 0.90) Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:50:19.49 +66:21:28.5: 14.93 +/- 0.16 detection Forced photometry reference-image weighted average: 14.69 +/- 0.10 Forced photometry reference-image weighted average: 15.28 +/- 0.16 Forced photometry reference-image weighted average: 14.50 +/- 0.07 Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:49:23.47 +65:20:38.5: 14.78 +/- 0.17 detection Forced photometry filter REJECTED candidate at 17:50:05.75 +65:10:58.3: ref_mag=14.69 +/- 0.10 new_mean_mag=14.7694 delta=-0.08 (need > 0.90) Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:25:22.53 +65:30:52.0: 15.17 +/- 0.20 detection Forced photometry filter REJECTED candidate at 16:54:59.11 +65:46:45.4: ref_mag=14.50 +/- 0.07 new_mean_mag=14.5166 delta=-0.01 (need > 0.90) Forced photometry filter REJECTED candidate at 17:51:11.16 +67:15:20.3: ref_mag=15.28 +/- 0.16 new_mean_mag=14.8596 delta=0.42 (need > 0.90) Forced photometry reference-image weighted average: 14.81 +/- 0.11 Forced photometry reference-image weighted average: 14.98 +/- 0.11 Forced photometry filter REJECTED candidate at 17:49:23.47 +65:20:38.5: ref_mag=14.81 +/- 0.11 new_mean_mag=14.7027 delta=0.10 (need > 0.90) Forced photometry filter REJECTED candidate at 17:25:22.53 +65:30:52.0: ref_mag=14.98 +/- 0.11 new_mean_mag=14.6950 delta=0.28 (need > 0.90) Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:56:14.37 +67:40:43.7: 14.84 +/- 0.13 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:49:32.41 +66:54:14.6: 14.77 +/- 0.15 detection Forced photometry reference-image weighted average: 14.92 +/- 0.12 Forced photometry filter REJECTED candidate at 17:49:32.41 +66:54:14.6: ref_mag=14.92 +/- 0.12 new_mean_mag=14.8279 delta=0.09 (need > 0.90) Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:50:19.49 +66:21:28.5: 14.95 +/- 0.18 detection Forced photometry reference-image weighted average: 14.94 +/- 0.12 Forced photometry filter REJECTED candidate at 17:50:19.49 +66:21:28.5: ref_mag=14.94 +/- 0.12 new_mean_mag=14.8033 delta=0.14 (need > 0.90) Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:56:14.37 +67:40:43.7: 14.44 +/- 0.11 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:52:30.06 +66:46:26.0: 15.63 +/- 0.29 detection Forced photometry reference-image weighted average: 14.61 +/- 0.09 Forced photometry filter REJECTED candidate at 17:56:14.37 +67:40:43.7: ref_mag=14.61 +/- 0.09 new_mean_mag=14.6771 delta=-0.07 (need > 0.90) Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 18:00:11.70 +68:27:35.2: 15.22 +/- 0.20 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 18:10:58.55 +70:52:24.3: 15.39 +/- 0.23 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:12:29.88 +65:44:03.0: 15.28 +/- 0.19 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:21:53.26 +66:20:32.0: 15.47 +/- 0.24 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:49:22.67 +68:59:30.1: 15.27 +/- 0.20 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:52:30.06 +66:46:26.0: 14.91 +/- 0.17 detection Forced photometry reference-image weighted average: 15.09 +/- 0.15 Forced photometry filter REJECTED candidate at 17:52:30.06 +66:46:26.0: ref_mag=15.09 +/- 0.15 new_mean_mag=14.8168 delta=0.28 (need > 0.90) Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 18:00:11.70 +68:27:35.2: 14.97 +/- 0.18 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 18:10:58.55 +70:52:24.3: 15.25 +/- 0.24 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:53:45.62 +66:50:24.8: 15.09 +/- 0.20 detection Forced photometry reference-image weighted average: 15.32 +/- 0.17 Forced photometry reference-image weighted average: 15.08 +/- 0.13 Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:12:29.88 +65:44:03.0: 15.05 +/- 0.17 detection Forced photometry filter REJECTED candidate at 18:00:11.70 +68:27:35.2: ref_mag=15.08 +/- 0.13 new_mean_mag=14.9600 delta=0.12 (need > 0.90) Forced photometry filter REJECTED candidate at 18:10:58.55 +70:52:24.3: ref_mag=15.32 +/- 0.17 new_mean_mag=14.8993 delta=0.42 (need > 0.90) Forced photometry reference-image weighted average: 15.16 +/- 0.13 Forced photometry filter REJECTED candidate at 17:12:29.88 +65:44:03.0: ref_mag=15.16 +/- 0.13 new_mean_mag=14.7528 delta=0.40 (need > 0.90) Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:47:58.15 +67:02:18.9: 14.93 +/- 0.14 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:21:53.26 +66:20:32.0: 14.83 +/- 0.14 detection Forced photometry reference-image weighted average: 15.00 +/- 0.12 Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:35:16.26 +68:26:14.1: 15.01 +/- 0.15 detection Forced photometry filter REJECTED candidate at 17:21:53.26 +66:20:32.0: ref_mag=15.00 +/- 0.12 new_mean_mag=14.7897 delta=0.21 (need > 0.90) Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:52:57.83 +66:55:48.4: 15.00 +/- 0.16 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:49:22.67 +68:59:30.1: 14.71 +/- 0.13 detection Forced photometry reference-image weighted average: 14.88 +/- 0.11 Forced photometry filter REJECTED candidate at 17:49:22.67 +68:59:30.1: ref_mag=14.88 +/- 0.11 new_mean_mag=14.7153 delta=0.17 (need > 0.90) Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:53:45.62 +66:50:24.8: 14.79 +/- 0.16 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:47:58.15 +67:02:18.9: 15.13 +/- 0.20 detection Forced photometry reference-image weighted average: 15.00 +/- 0.12 Forced photometry filter REJECTED candidate at 17:47:58.15 +67:02:18.9: ref_mag=15.00 +/- 0.12 new_mean_mag=14.8797 delta=0.12 (need > 0.90) Forced photometry reference-image weighted average: 14.91 +/- 0.13 Forced photometry filter REJECTED candidate at 17:53:45.62 +66:50:24.8: ref_mag=14.91 +/- 0.13 new_mean_mag=14.8620 delta=0.05 (need > 0.90) Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:52:57.83 +66:55:48.4: 14.67 +/- 0.14 detection Forced photometry reference-image weighted average: 14.81 +/- 0.11 Forced photometry filter REJECTED candidate at 17:52:57.83 +66:55:48.4: ref_mag=14.81 +/- 0.11 new_mean_mag=14.8775 delta=-0.07 (need > 0.90) Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:35:16.26 +68:26:14.1: 15.10 +/- 0.17 detection Forced photometry reference-image weighted average: 15.05 +/- 0.11 Forced photometry filter REJECTED candidate at 17:35:16.26 +68:26:14.1: ref_mag=15.05 +/- 0.11 new_mean_mag=14.8340 delta=0.21 (need > 0.90) Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:50:05.18 +67:08:01.8: 15.25 +/- 0.20 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:46:56.35 +68:53:52.8: 15.14 +/- 0.18 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:51:53.76 +68:46:04.9: 15.64 +/- 0.28 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:35:20.58 +65:48:12.3: 15.43 +/- 0.22 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:50:05.18 +67:08:01.8: 14.82 +/- 0.15 detection Forced photometry reference-image weighted average: 14.98 +/- 0.12 Forced photometry filter REJECTED candidate at 17:50:05.18 +67:08:01.8: ref_mag=14.98 +/- 0.12 new_mean_mag=14.8565 delta=0.12 (need > 0.90) Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 18:00:41.19 +70:02:49.3: 15.30 +/- 0.23 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:36:38.73 +68:41:53.6: 14.91 +/- 0.15 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:46:56.35 +68:53:52.8: 14.95 +/- 0.16 detection Forced photometry reference-image weighted average: 15.03 +/- 0.12 Forced photometry filter REJECTED candidate at 17:46:56.35 +68:53:52.8: ref_mag=15.03 +/- 0.12 new_mean_mag=14.9040 delta=0.13 (need > 0.90) Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:51:53.76 +68:46:04.9: 14.97 +/- 0.18 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 18:06:50.25 +70:45:12.8: 15.10 +/- 0.18 detection Forced photometry reference-image weighted average: 15.17 +/- 0.15 Forced photometry filter REJECTED candidate at 17:51:53.76 +68:46:04.9: ref_mag=15.17 +/- 0.15 new_mean_mag=14.9567 delta=0.21 (need > 0.90) Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 18:00:41.19 +70:02:49.3: 14.95 +/- 0.18 detection Forced photometry reference-image weighted average: 15.08 +/- 0.14 Forced photometry filter REJECTED candidate at 18:00:41.19 +70:02:49.3: ref_mag=15.08 +/- 0.14 new_mean_mag=14.8910 delta=0.19 (need > 0.90) Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:41:55.87 +68:50:44.1: 15.15 +/- 0.17 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:56:18.82 +70:50:41.2: 15.13 +/- 0.19 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:35:20.58 +65:48:12.3: 14.93 +/- 0.17 detection Forced photometry reference-image weighted average: 15.10 +/- 0.13 Forced photometry filter REJECTED candidate at 17:35:20.58 +65:48:12.3: ref_mag=15.10 +/- 0.13 new_mean_mag=14.8982 delta=0.21 (need > 0.90) Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:28:48.84 +73:35:28.0: 15.52 +/- 0.25 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:36:38.73 +68:41:53.6: 14.91 +/- 0.16 detection Forced photometry reference-image weighted average: 14.91 +/- 0.11 Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 18:06:50.25 +70:45:12.8: 15.30 +/- 0.24 detection Forced photometry filter REJECTED candidate at 17:36:38.73 +68:41:53.6: ref_mag=14.91 +/- 0.11 new_mean_mag=14.8626 delta=0.05 (need > 0.90) Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:41:55.87 +68:50:44.1: 15.19 +/- 0.21 detection Forced photometry reference-image weighted average: 15.17 +/- 0.13 Forced photometry reference-image weighted average: 15.17 +/- 0.15 Forced photometry filter REJECTED candidate at 18:06:50.25 +70:45:12.8: ref_mag=15.17 +/- 0.15 new_mean_mag=14.9029 delta=0.27 (need > 0.90) Forced photometry filter REJECTED candidate at 17:41:55.87 +68:50:44.1: ref_mag=15.17 +/- 0.13 new_mean_mag=14.9179 delta=0.25 (need > 0.90) Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:56:18.82 +70:50:41.2: 14.72 +/- 0.14 detection Forced photometry reference-image weighted average: 14.87 +/- 0.11 Forced photometry filter REJECTED candidate at 17:56:18.82 +70:50:41.2: ref_mag=14.87 +/- 0.11 new_mean_mag=14.8988 delta=-0.03 (need > 0.90) Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:28:48.84 +73:35:28.0: 14.97 +/- 0.16 detection Forced photometry reference-image weighted average: 15.14 +/- 0.14 Forced photometry filter REJECTED candidate at 17:28:48.84 +73:35:28.0: ref_mag=15.14 +/- 0.14 new_mean_mag=14.7254 delta=0.41 (need > 0.90) Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:12:45.11 +68:01:46.9: 14.86 +/- 0.13 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:19:48.64 +68:13:51.9: 14.94 +/- 0.14 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:05:35.96 +68:17:18.5: 16.01 +/- 99.00 upperlimit Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:31:18.19 +69:48:06.0: 15.69 +/- 0.27 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-06-21_02-08-37_20.00sec_5.00C_LIGHT_0262.fits at 17:23:10.75 +68:22:19.4: 15.17 +/- 0.17 detection Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:19:48.64 +68:13:51.9: 14.99 +/- 0.15 detection Forced photometry reference-image weighted average: 14.96 +/- 0.10 Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:12:45.11 +68:01:46.9: 14.93 +/- 0.14 detection Forced photometry filter REJECTED candidate at 17:19:48.64 +68:13:51.9: ref_mag=14.96 +/- 0.10 new_mean_mag=14.7075 delta=0.25 (need > 0.90) Forced photometry reference-image weighted average: 14.89 +/- 0.10 Forced photometry filter REJECTED candidate at 17:12:45.11 +68:01:46.9: ref_mag=14.89 +/- 0.10 new_mean_mag=14.8915 delta=-0.00 (need > 0.90) Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:05:35.96 +68:17:18.5: 15.05 +/- 0.16 detection Forced photometry reference-image weighted average: 15.05 +/- 0.16 Forced photometry filter REJECTED candidate at 17:05:35.96 +68:17:18.5: ref_mag=15.05 +/- 0.16 new_mean_mag=15.0163 delta=0.03 (need > 0.90) Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:31:18.19 +69:48:06.0: 15.05 +/- 0.16 detection Forced photometry reference-image weighted average: 15.22 +/- 0.14 Forced photometry filter REJECTED candidate at 17:31:18.19 +69:48:06.0: ref_mag=15.22 +/- 0.14 new_mean_mag=14.9809 delta=0.24 (need > 0.90) Forced photometry on wcs_Dra-04-Q2b1x1_2026-07-18_00-37-07_20.00sec_5.00C_LIGHT_0188.fits at 17:23:10.75 +68:22:19.4: 15.46 +/- 0.24 detection Forced photometry reference-image weighted average: 15.27 +/- 0.14 Forced photometry filter REJECTED candidate at 17:23:10.75 +68:22:19.4: ref_mag=15.27 +/- 0.14 new_mean_mag=14.9365 delta=0.33 (need > 0.90) make_report_in_HTML.sh Phase 1 (network queries): 11s Pre-generating preview images in parallel... Done pre-generating preview images. Pre-generating finding charts in parallel... Done pre-generating finding charts. make_report_in_HTML.sh Pre-generation: 0s xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 72790_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 72790_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 2   2026 09 12.26231    2461295.76231    14.75    18:01:36.78 +71:06:32.3   1248 1959   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits **** FOUND 18:01:36.80 +71:06:32.4 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 72794_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 72794_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.66    17:37:25.20 +66:27:00.1   1849 5023   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.66    17:37:25.45 +66:26:59.2   1846 5029   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 72796_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 72796_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.55    17:43:19.46 +71:17:29.2   2150 2079   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.57    17:43:19.16 +71:17:30.4   2147 2085   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 72801_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 72801_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.43    17:18:14.09 +66:52:31.3   3033 4945   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.41    17:18:14.43 +66:52:32.3   3029 4952   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 72802_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 72802_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 2   2026 09 12.26231    2461295.76231    14.41    17:26:17.00 +65:54:13.3   2463 5473   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits Rejecting candidate due to large distance (27.2") between the two second-epoch detections xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 72803_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 72803_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.44    17:47:35.14 +69:28:24.4   1684 3103   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.70    17:47:35.71 +69:28:24.5   1680 3109   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 72804_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 72804_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.32    17:45:22.34 +70:57:15.0   2005 2255   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.13    17:45:22.74 +70:57:13.6   2002 2262   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 72805_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 72805_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.28    17:16:09.20 +69:00:07.2   3300 3678   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.62    17:16:09.24 +69:00:06.9   3297 3684   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 72808_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 72808_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.14    16:58:15.89 +67:28:41.8   4231 4671   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.13    16:58:15.51 +67:28:43.2   4228 4677   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 72911_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 72911_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    11.88    17:31:49.29 +68:10:36.0   2369 4050   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    11.86    17:31:49.32 +68:10:35.9   2366 4057   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 72974_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 72974_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    12.63    17:47:59.87 +66:04:16.7   1162 5111   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    12.63    17:47:59.92 +66:04:16.9   1158 5117   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 72987_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 72987_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    12.69    18:08:05.66 +69:46:05.4   0682 2628   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    12.69    18:08:05.56 +69:46:05.8   0679 2634   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73035_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73035_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    13.04    17:48:23.15 +69:06:49.6   1589 3305   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    13.06    17:48:23.09 +69:06:49.2   1586 3312   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73064_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73064_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    12.99    16:56:44.37 +67:26:13.3   4318 4699   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    12.96    16:56:44.36 +67:26:12.8   4315 4706   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73167_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73167_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    13.80    18:06:17.46 +68:58:52.2   0622 3114   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.03    18:06:17.57 +68:58:53.5   0619 3120   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73170_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73170_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    13.84    17:45:23.93 +65:40:38.2   1263 5382   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    13.96    17:45:23.65 +65:40:39.8   1260 5389   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73177_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73177_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 2   2026 09 12.26231    2461295.76231    13.85    17:42:53.65 +66:06:25.4   1472 5166   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits **** FOUND 17:42:53.61 +66:06:25.8 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73242_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73242_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 2   2026 09 12.26231    2461295.76231    13.95    17:37:59.99 +67:24:15.7   1929 4453   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits **** FOUND 17:37:59.98 +67:24:16.0 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73260_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73260_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.02    17:39:00.68 +68:13:06.7   1975 3950   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.00    17:39:00.93 +68:13:06.6   1972 3956   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73276_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73276_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.19    17:49:56.15 +66:11:07.1   1062 5015   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.12    17:49:56.26 +66:11:06.1   1059 5022   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73297_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73297_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    13.86    16:52:36.92 +71:05:07.5   4591 2498   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    13.87    16:52:36.88 +71:05:07.9   4588 2505   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73317_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73317_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    13.91    16:30:24.37 +67:20:16.9   5850 4725   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.10    16:30:24.15 +67:20:17.5   5847 4732   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73343_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73343_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.40    17:48:37.39 +65:41:44.5   1068 5325   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.58    17:48:37.20 +65:41:44.0   1065 5332   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73361_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73361_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.32    17:38:02.31 +67:36:37.6   1955 4323   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.34    17:38:02.02 +67:36:36.7   1952 4329   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73387_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73387_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 2   2026 09 12.26231    2461295.76231    14.05    17:25:38.70 +65:55:43.4   2505 5464   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits **** FOUND 17:25:38.58 +65:55:42.7 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73389_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73389_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.41    17:58:39.88 +69:27:23.0   1106 2959   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.41    17:58:40.50 +69:27:22.8   1103 2966   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73400_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73400_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.57    17:43:46.84 +65:21:30.9   1319 5595   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.64    17:43:46.86 +65:21:30.4   1316 5602   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73429_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73429_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 2   2026 09 12.26231    2461295.76231    14.57    17:46:28.08 +65:27:17.2   1162 5507   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits **** FOUND 17:46:28.01 +65:27:17.1 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73442_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73442_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.61    17:43:10.06 +65:29:49.8   1376 5521   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.54    17:43:09.76 +65:29:49.3   1373 5527   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73446_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73446_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.59    18:03:03.97 +69:23:51.8   0868 2925   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.64    18:03:03.95 +69:23:53.5   0865 2931   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73456_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73456_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.53    17:42:15.12 +68:20:55.8   1813 3834   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.40    17:42:15.24 +68:20:53.7   1810 3841   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73464_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73464_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.58    17:25:36.26 +65:56:53.0   2512 5446   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.64    17:25:36.04 +65:56:52.1   2509 5453   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73465_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73465_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.56    17:46:59.88 +68:36:36.1   1590 3620   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.49    17:46:59.87 +68:36:35.0   1587 3627   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73468_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73468_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.59    17:35:58.57 +66:15:29.9   1913 5154   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.45    17:35:58.89 +66:15:28.8   1910 5161   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73483_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73483_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.72    17:44:15.17 +66:42:51.9   1478 4780   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.75    17:44:15.10 +66:42:51.9   1475 4787   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73493_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73493_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.59    17:53:13.97 +69:31:36.5   1399 2997   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.48    17:53:13.83 +69:31:37.4   1396 3003   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73501_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73501_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.72    17:52:20.54 +65:30:29.3   0809 5380   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.71    17:52:20.65 +65:30:29.4   0806 5387   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73521_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73521_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.49    16:54:58.90 +65:46:46.2   4395 5708   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.55    16:54:59.32 +65:46:44.5   4392 5715   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73527_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73527_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.79    17:49:23.41 +65:20:39.2   0967 5523   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.64    17:49:23.52 +65:20:37.8   0964 5530   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73528_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73528_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.67    17:25:22.49 +65:30:53.0   2486 5710   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.73    17:25:22.57 +65:30:51.1   2483 5717   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73540_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73540_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.75    17:51:11.01 +67:15:19.1   1154 4363   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    15.09    17:51:11.31 +67:15:21.5   1150 4369   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73545_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73545_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.78    17:50:05.77 +65:10:56.9   0898 5609   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.76    17:50:05.72 +65:10:59.6   0895 5615   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73557_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73557_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.80    17:49:32.46 +66:54:14.2   1195 4595   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.87    17:49:32.36 +66:54:15.0   1192 4601   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73560_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73560_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 2   2026 09 12.26231    2461295.76231    14.99    17:54:00.15 +65:15:17.3   0662 5511   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits **** FOUND 17:54:00.23 +65:15:17.3 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73572_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73572_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.80    17:50:19.59 +66:21:28.7   1065 4907   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.81    17:50:19.39 +66:21:28.4   1062 4913   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73587_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73587_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.80    17:56:14.55 +67:40:43.6   0935 4038   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.60    17:56:14.18 +67:40:43.7   0932 4044   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73592_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73592_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.83    17:52:29.93 +66:46:25.6   1002 4628   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.80    17:52:30.19 +66:46:26.4   0998 4634   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73610_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73610_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.90    18:00:11.54 +68:27:35.2   0851 3518   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    15.13    18:00:11.86 +68:27:35.2   0848 3524   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73611_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73611_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.71    17:12:29.83 +65:44:02.9   3305 5672   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.81    17:12:29.94 +65:44:03.2   3302 5679   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73626_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73626_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 2   2026 09 12.26231    2461295.76231    14.93    17:46:52.40 +65:14:24.3   1105 5629   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits **** FOUND 17:46:52.29 +65:14:24.1 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73636_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73636_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.82    18:10:58.31 +70:52:23.1   0760 1942   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    15.06    18:10:58.79 +70:52:25.5   0757 1948   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73638_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73638_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.73    17:49:22.56 +68:59:30.3   1518 3364   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.70    17:49:22.78 +68:59:29.9   1515 3370   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73651_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73651_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.77    17:21:53.06 +66:20:32.3   2773 5240   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.81    17:21:53.46 +66:20:31.7   2769 5246   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73654_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73654_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.86    17:53:45.83 +66:50:25.9   0939 4569   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.86    17:53:45.40 +66:50:23.8   0936 4576   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73655_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73655_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.87    17:47:58.43 +67:02:18.5   1306 4537   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.89    17:47:57.87 +67:02:19.2   1304 4544   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73658_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73658_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.89    17:52:57.93 +66:55:48.1   1000 4529   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.87    17:52:57.73 +66:55:48.7   0997 4535   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73661_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73661_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.82    17:35:16.42 +68:26:14.8   2207 3860   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.85    17:35:16.10 +68:26:13.4   2205 3867   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73671_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73671_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.87    17:50:05.20 +67:08:01.1   1198 4451   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.85    17:50:05.17 +67:08:02.4   1195 4457   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73705_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73705_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.88    17:51:53.77 +68:46:03.2   1349 3462   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    15.09    17:51:53.74 +68:46:06.7   1347 3468   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73707_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73707_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.90    17:35:20.59 +65:48:12.4   1898 5434   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.90    17:35:20.57 +65:48:12.2   1895 5441   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73709_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73709_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.89    18:00:41.27 +70:02:49.6   1107 2584   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.89    18:00:41.10 +70:02:49.0   1104 2591   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73715_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73715_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.86    17:46:56.45 +68:53:52.3   1634 3451   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.98    17:46:56.25 +68:53:53.3   1632 3457   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73718_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73718_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.81    17:36:38.62 +68:41:53.5   2163 3690   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.93    17:36:38.83 +68:41:53.7   2160 3696   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73745_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73745_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.92    18:06:50.63 +70:45:11.6   0934 2079   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.88    18:06:49.88 +70:45:14.0   0932 2085   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73769_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73769_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.66    17:28:48.69 +73:35:27.4   3071 0838   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.81    17:28:49.00 +73:35:28.6   3068 0844   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73771_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73771_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.89    17:41:55.72 +68:50:43.9   1896 3544   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.95    17:41:56.02 +68:50:44.4   1893 3550   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73800_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73800_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.89    17:56:19.11 +70:50:41.4   1459 2182   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.90    17:56:18.52 +70:50:41.1   1456 2188   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73833_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73833_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.81    17:19:48.56 +68:13:52.0   3044 4118   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.65    17:19:48.72 +68:13:51.8   3041 4124   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73838_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73838_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.82    17:12:45.02 +68:01:45.9   3426 4283   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    15.00    17:12:45.20 +68:01:47.9   3423 4289   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73896_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73896_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.90    17:23:10.73 +68:22:19.7   2868 4008   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    14.99    17:23:10.78 +68:22:19.0   2865 4015   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 73924_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 73924_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.90    17:31:18.32 +69:48:05.9   2569 3085   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    15.10    17:31:18.05 +69:48:06.2   2566 3091   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 74026_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 74026_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 1   2026 09 12.26178    2461295.76178    14.93    17:05:35.96 +68:17:18.4   3840 4159   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-16-47_20.00sec_-0.00C_LIGHT_0294.fits Discovery image 2   2026 09 12.26231    2461295.76231    15.20    17:05:35.97 +68:17:18.6   3837 4166   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 19446_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 19446_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 3   2026 09 12.26231    2461295.76231    11.61    17:04:04.88 +71:47:44.6   4054 2054   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits **** FOUND 17:04:04.85 +71:47:44.3 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 41567_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 The candidate 41567_fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295 did not pass the final checks Discovery image 3   2026 09 12.26231    2461295.76231    12.97    16:00:39.40 +68:37:31.0   7415 3733   /data_ssd/NMW-TexasTech/workdir//img_2026-09-12_CI_Dra-04-Q2b1x1_012244_TTUQ2b1x1_1880831_SncBcVKp/fd_Dra-04-Q2b1x1_2026-09-12_01-17-33_20.00sec_-0.00C_LIGHT_0295.fits **** FOUND 16:00:39.31 +68:37:30.8 in the exclusion list exclusion_list.txt **** make_report_in_HTML.sh Phase 2 (HTML assembly): 0s make_report_in_HTML.sh TOTAL: 11s Prepared the HTML report for the field Dra-04-Q2b1x1 with default.sex.telephoto_lens_vSTL *------ done with default.sex.telephoto_lens_vSTL ------* #### The local exclusion list is exclusion_list_local.txt #### ########### Completed Dra-04-Q2b1x1 ########### The analysis was running at tau We are allowed to update the exclusion list at tau host Found ../exclusion_list_TTUQ2.txt #### The exclusion list before filtering-out asteroids, bad pixels and adding Gaia sources #### ################################################################################### renamed 'exclusion_list_index_html.txt_noasteroids' -> 'exclusion_list_index_html.txt' renamed 'exclusion_list_index_html.txt_nohotpixels' -> 'exclusion_list_index_html.txt' # Count candidates with no identification (that also don't look like hot pix) Found 0 unidentified candidates (excluding asteroids, hot pixels and known variable stars). ################################################################################### 0 candidates found (excluding asteroids and hot pixels) This does not look like a test run ################################################################################### exclusion_list_gaiadr2.txt NOT FOUND exclusion_list_apass.txt NOT FOUND IS_THIS_TEST_RUN=NO ALLOW_EXCLUSION_LIST_UPDATE= YES #### Nothing to add to the exclusion list #### The observatory MPC code is V36 ############################################################ Positions of planets computed with util/planet_finder/main.py for JD(UT)2461295.76178120 -observatory V36 12:09:14.40 -00:23:26.5 Mercury (-0.6mag) 13:47:50.68 -16:18:45.0 Venus (-4.7mag) 07:27:17.25 +22:38:07.5 Mars (1.2mag) 09:13:05.60 +16:40:19.2 Jupiter (-1.8mag) 00:50:32.64 +02:30:16.9 Saturn (0.4mag) 04:13:42.36 +21:02:02.5 Uranus (5.7mag) 00:13:16.17 -00:06:26.3 Neptune (7.7mag) 20:25:16.09 -23:40:40.8 Pluto (14.5mag) 12:06:01.11 -04:24:54.4 Moon (-8.5mag) -rw-r--r-- 1 apache apache 362 Sep 12 02:24 planets.txt ############################################################ Positions of selected moons from JPL HORIZONS for JD(UT)2461295.76178120: 09:13:13.00 +16:39:42.8 Io (6.0mag) 09:13:05.55 +16:40:19.9 Europa (6.2mag) 09:13:16.45 +16:39:26.5 Ganymede (5.6mag) 09:13:23.82 +16:38:50.3 Callisto (6.9mag) 09:11:02.98 +16:58:53.4 Himalia (15.7mag) 09:13:04.65 +16:40:24.5 Thebe (16.6mag) 09:10:36.58 +16:52:47.0 Elara (17.7mag) 09:16:51.49 +16:06:29.9 Pasiphae (17.9mag) 09:13:49.03 +16:59:28.1 Carme (18.9mag) 00:50:20.99 +02:30:00.3 Titan (8.3mag) 00:50:28.20 +02:30:02.2 Rhea (9.6mag) 00:50:33.81 +02:32:12.7 Iapetus (11.0mag) 00:50:42.19 +02:30:27.3 Hyperion (14.3mag) 00:49:14.35 +02:19:34.4 Phoebe (16.4mag) -rw-r--r-- 1 apache apache 568 Sep 12 02:24 moons.txt ############################################################ Positions of selected spacecraft from JPL HORIZONS for JD(UT)2461295.76178120: 22:45:19.08 +06:03:01.5 JWST 17:05:31.97 +40:56:46.3 Chandra 05:40:36.65 +36:47:38.7 XMM-Newton -rw-r--r-- 1 apache apache 96 Sep 12 02:24 spacecraft.txt ############################################################ Positions of bright comets computed with util/comet_finder/main.py for JD(UT)2461295.76178120 -observatory V36 03:43:06.27 +19:33:21.4 17.3mag P/1996 R2 (Lagerkvist) 18:04:52.57 -34:07:04.2 14.4mag P/2010 H2 (Vales) 07:23:08.24 -70:34:53.2 17.3mag C/2014 UN271 (Bernardinelli-Bernstein) 06:16:11.46 +33:49:49.9 17.7mag C/2017 K2 (PANSTARRS) 22:09:35.87 +28:02:55.9 17.5mag C/2022 E2 (ATLAS) 07:13:51.34 +25:53:15.4 16.9mag C/2022 N2 (PANSTARRS) 10:54:03.67 +27:03:11.0 17.1mag C/2022 QE78 (ATLAS) 09:51:47.84 +05:12:19.0 18.0mag C/2022 R6 (PANSTARRS) 15:28:22.97 -16:05:02.6 14.9mag C/2023 R1 (PANSTARRS) 08:42:38.03 +33:12:31.7 15.9mag C/2024 E1 (Wierzchos) 15:07:18.59 +15:16:00.8 17.9mag C/2024 G6 (ATLAS) 18:30:46.69 +42:58:13.8 13.7mag C/2024 J3 (ATLAS) 20:19:33.27 +49:00:12.0 17.4mag C/2024 R4 (PANSTARRS) 05:38:07.23 -13:05:56.9 15.1mag C/2024 T5 (ATLAS) 07:13:11.67 +17:32:18.7 17.8mag C/2025 J1 (Borisov) 11:26:03.25 +18:22:42.4 16.7mag C/2025 V2 (Rankin) 13:23:46.82 -00:17:13.4 16.8mag C/2025 Y1 (ATLAS) 16:55:10.28 +73:10:40.0 16.0mag C/2026 A2 (Bok) 03:03:02.83 +45:57:02.9 17.5mag C/2026 B2 (Sun-Gao) 12:17:53.61 +11:41:19.6 17.6mag A/2026 E1 22:30:09.51 -35:14:17.1 13.5mag 10P/Tempel 01:27:14.93 +37:58:47.9 17.7mag 11P/Tempel-Swift-LINEAR 11:51:30.40 -05:50:39.8 16.3mag 29P/Schwassmann-Wachmann 12:18:33.98 -06:39:27.8 17.7mag 63P/Wild 06:48:46.73 +18:51:27.0 13.8mag 78P/Gehrels 03:17:10.40 +15:02:17.9 17.2mag 88P/Howell 05:54:54.51 +30:30:37.7 16.8mag 112P/Urata-Niijima 07:46:21.33 +23:30:05.2 15.9mag 114P/Wiseman-Skiff 10:38:55.45 +19:48:17.1 14.8mag 123P/West-Hartley 12:57:37.06 -23:03:07.7 17.5mag 124P/Mrkos 06:23:17.97 +20:28:42.6 15.9mag 128P/Shoemaker-Holt 02:09:55.61 -16:51:29.4 14.9mag 161P/Hartley-IRAS 09:06:50.30 +37:22:02.4 16.5mag 162P/Siding Spring 09:32:04.50 +10:56:18.9 13.4mag 169P/NEAT 03:28:09.54 +08:02:15.2 14.5mag 220P/McNaught 05:01:15.29 +37:50:10.1 15.2mag 260P/McNaught 08:45:01.91 +35:09:16.2 17.3mag 295P/LINEAR 15:28:33.21 -00:48:16.1 17.9mag 391P/Kowalski 09:32:02.43 +16:35:50.6 17.8mag 450P/LONEOS -rw-r--r-- 1 apache apache 2.0K Sep 12 02:24 comets.txt ############################################################ List of recent ASAS-SN transients from https://www.astronomy.ohio-state.edu/asassn/transients.html : 04:59:14.53 -83:27:58.80 ASASSN-26fd 2026-09-9.11 17.27 17:52:06.79 -23:43:20.70 ASASSN-26fc 2026-09-8.79 12.14 03:52:53.26 -14:19:28.70 SN 2026zfw 2026-09-8 17.78 01:53:26.46 +10:07:25.10 SN2026aacj 2026-09-7.17 16.27 20:04:34.47 +62:38:38.10 SN2026zji 2026-09-7.14 15.87 22:37:05.64 +34:24:35.00 SN2026aaiv 2026-09-7.25 13.48 22:24:21.29 -10:25:31.60 ASASSN-26fb 2026-09-5.3 13.93 00:44:54.28 +41:33:10.50 AT2026aabo 2026-09-3.29 15.02 00:52:12.40 -58:22:08.60 SN 2026zhl 2026-08-31.92 16.51 19:53:57.87 +61:00:19.70 ASASSN-26fa 2026-08-31.18 14.63 00:21:50.96 -09:29:16.30 AT2026zwp 2026-08-31.41 15.59 19:45:06.20 +18:22:48.80 V488 2026-08-30.13 9.37 18:25:12.74 -22:25:28.60 V8055 2026-08-30.22 10.89 17:17:45.96 +64:31:40.10 ASASSN-26ez 2026-08-25.13 10.87 19:02:47.09 +58:08:21.00 AT2026zwo 2026-08-24.16 15.78 04:20:07.58 -42:26:59.90 AT2026zjy 2026-08-23.03 15.91 03:08:18.02 +11:54:46.50 SN2026ymb 2026-08-23.4 16.44 20:22:32.48 -50:45:14.30 SN2026yid 2026-08-22.82 15.13 04:24:28.39 -56:20:21.60 ASASSN-26ey 2026-08-20.02 15.55 16:46:37.81 -63:14:59.80 ASASSN-26ex 2026-08-18.78 3.63 21:28:47.85 +20:31:03.60 SN 2026sfn 2026-08-16.3 17.09 23:01:28.67 -61:00:39.00 SN 2026yib 2026-08-14.85 17.36 00:22:23.20 -32:16:02.70 SN 2026whu 2026-08-14.96 16.5 19:56:21.71 -37:24:19.90 ASASSN-26ew 2026-08-13.82 14.73 13:53:14.21 +00:26:52.00 SN 2026wkv 2026-08-10.12 15.83 05:21:07.61 +23:38:20.10 TCP J05210763+2338194 2026-08-10.59 9.34 01:28:20.49 +40:13:27.10 SN2026wpd 2026-08-9.34 16.37 23:47:50.87 +49:28:49.80 SN2026wjs 2026-08-9.35 17.12 16:03:20.92 +17:43:23.70 AT2026xau 2026-08-9.3 17.71 01:10:22.05 -09:34:08.50 SN2026weo 2026-08-7.46 15.76 00:56:54.35 -35:55:29.40 AT2026wdy 2026-08-5.05 16.08 22:08:07.63 -53:03:58.90 AT2026wek 2026-08-3.82 17.17 14:51:51.34 +66:13:24.60 ASASSN-26ev 2026-08-2.15 14.02 12:06:50.79 -36:16:06.20 SN2026wgm 2026-08-1.73 15.61 16:56:36.90 -59:29:26.00 ASASSN-26er 2026-07-25.82 15.09 01:21:27.83 -10:37:05.00 SN2026vbh 2026-07-25.61 15.97 21:17:31.59 +22:25:50.90 ASASSN-26eq 2026-07-24.37 15.13 18:53:36.89 +16:56:43.60 ASASSN-26ep 2026-07-23.47 -4.06 12:18:47.98 -30:48:47.50 ASASSN-26et 2026-07-22.76 13.98 13:00:47.82 +15:42:17.60 SN2026uwk 2026-07-21.75 16.38 18:52:31.11 -32:28:00.90 ASASSN-26en 2026-07-21.77 14.63 14:42:58.01 -62:32:59.10 ASASSN-26es 2026-07-20.79 15.36 20:12:45.57 -32:53:13.00 ASASSN-26em 2026-07-20.94 16.83 18:54:24.33 -46:11:51.70 ASASSN-26eu 2026-07-20.93 14.86 03:18:56.99 -80:55:10.40 AT2026ugi 2026-07-20.03 17.12 18:43:58.40 +24:22:41.80 ASASSN-26eo 2026-07-19.36 16.16 04:50:01.03 -02:22:33.80 ASASSN-26ej 2026-07-16.17 17.02 18:34:55.28 -31:41:00.90 ASASSN-26ek 2026-07-16.24 15.73 17:07:43.61 -44:21:53.50 ASASSN-26el 2026-07-15.86 16.01 14:45:08.35 +24:13:12.30 ASASSN-26ei 2026-07-16.17 16.46 10:00:46.44 -32:36:31.10 AT 2023mhb 2026-07-14.73 16.67 14:39:37.45 -11:22:36.20 AT 2026unl 2026-07-15.27 17.11 10:49:42.57 -11:25:55.80 ASASSN-26eh 2026-07-14.72 16.58 19:33:53.06 -07:15:00.80 ASASSN-22le 2026-07-14.15 15.5 02:45:40.52 -27:55:30.30 ASASSN-26ef 2026-07-12.35 15.86 23:26:43.80 +04:42:39.70 SN 2026qtn 2026-07-12.22 16.47 02:19:17.26 +28:57:15.40 ASASSN-26ec 2026-07-11.53 2.78 18:31:15.56 -05:34:31.50 AT2026stb 2026-07-11.28 -1.29 13:36:08.24 +23:29:05.00 AT2026pjf 2026-07-10.18 -0.72 17:33:39.82 +04:22:36.70 SN2026pir 2026-07-9.86 -0.66 11:21:41.26 -50:33:36.30 ASASSN-26ed 2026-07-8.8 -1.3 23:41:42.11 +26:29:49.10 AT2026qil 2026-07-9.3 16.15 20:21:30.50 -32:03:40.10 ASASSN-26ee 2026-07-7.22 15.53 19:37:44.09 -05:35:42.80 AT2026ryu 2026-07-7.17 14.88 11:06:55.46 -04:07:04.50 AT2026qqg 2026-07-5.01 16.82 19:07:23.69 -74:13:37.30 AT2026qly 2026-07-5.02 17.31 17:57:43.80 +27:18:40.10 ASASSN-26ea 2026-07-5.07 16.67 19:59:01.43 -32:07:34.30 ASASSN-26eb 2026-07-4.97 15.52 18:46:50.35 -57:44:13.20 SN 2026qqp 2026-07-5.03 -0.92 19:17:31.69 -39:55:29.90 ASASSN-26dz 2026-07-5.14 15.91 19:14:31.37 +12:03:52.90 AT 2026rdg 2026-07-3.43 11.81 04:05:50.09 -70:24:34.40 AT 2026qpr 2026-06-30.4 15.96 13:45:37.49 -05:59:35.80 SN 2026pub 2026-06-30.09 16.01 16:41:15.63 +39:17:14.70 SN 2026pel 2026-06-26.38 16.07 10:14:40.19 -35:38:21.30 ASASSN-26dy 2026-06-25.99 15.63 14:47:21.56 -40:15:51.30 ASASSN-26dv 2026-06-23.03 14.62 13:38:49.79 -77:21:06.70 ASASSN-26dw 2026-06-23.04 16.09 00:59:27.90 +33:08:13.20 SN 2026mke 2026-06-22.39 17.13 11:10:44.73 -30:20:45.50 SN 2026nmv 2026-06-22.06 16.56 21:36:15.68 -21:19:12.50 AT2026oxh 2026-06-22.15 17.14 17:31:38.38 -56:05:51.90 ASASSN-26dx 2026-06-22.02 14.72 14:10:13.44 -38:46:46.10 AT2026pvk 2026-06-22.06 16.53 20:56:47.23 -18:31:05.20 AT2026plb 2026-06-21.31 16.4 15:44:29.68 +21:00:59.30 SN2026ore 2026-06-21.29 17.57 23:50:05.98 -14:01:41.30 AT2026oxl 2026-06-21.52 17.64 17:36:54.73 -18:10:04.20 AT2026ouj 2026-06-20.92 15.15 00:34:04.08 -30:22:09.20 AT2026ntk 2026-06-18.09 17.34 20:49:13.39 +25:17:59.20 ASASSN-26du 2026-06-15.39 15.93 23:09:30.84 +32:40:42.00 SN2026oxc 2026-06-14.35 16.83 02:02:26.67 +32:04:22.70 AT2026ovz 2026-06-14.6 15.52 21:26:28.11 -72:31:19.50 AT2026nwc 2026-06-11 17.05 17:54:57.33 +26:32:34.20 SN 2026odc 2026-06-11.23 17.62 13:55:59.94 +17:30:37.20 SN 2026nyq 2026-06-11.1 16.24 00:50:45.14 -71:38:36.90 ASASSN-26dt 2026-06-11.13 10.22 14:42:19.73 +19:11:35.60 SN2026nyp 2026-06-10.3 16.32 12:23:23.92 +12:56:43.50 SN2026mta 2026-06-8.29 16.69 12:30:18.51 +47:12:33.20 SN2026oao 2026-06-9.32 17.02 10:51:05.21 -42:28:56.60 AT2026nvf 2026-06-8.12 16.75 13:50:22.48 -07:35:00.00 SN2026npn 2026-06-8.02 17.58 00:56:07.17 +43:01:43.20 ASASSN-26dq 2026-06-7.43 13.58 -rw-r--r-- 1 apache apache 5.7K Sep 12 02:24 asassn_transients_list.txt ############################################################ Truncated list of TOCP transients from http://www.cbat.eps.harvard.edu/unconf/tocp.html : 20:35:43.64 +61:31:32.9 TCP J20354364+6131329 2026-07-20.5443 14.4mag 21:17:31.48 +22:25:51.0 TCP J21173148+2225510 2026-07-23.5577 14.8mag 00:41:24.04 +40:49:02.8 PNV J00412404+4049028 2026-07-25.0157 18.7mag 00:43:04.26 +41:02:28.6 PNV J00430426+4102286 2026-07-26.1512 20mag 14:51:51.40 +66:13:24.0 TCP J14515140+6613240 2026-07-29.2561 13.5mag 00:43:06.15 +41:22:08.2 PNV J00430615+4122082 2026-07-30.0085 19.4mag 00:41:33.23 +41:10:12.2 PNV J00413323+4110122 2026-08-02.8913 17.1mag 05:21:07.63 +23:38:19.4 TCP J05210763+2338194 2026-08-06.4109 11.2mag 22:57:17.96 +47:07:41.8 TCP J22571796+4707418 2026-08-09.3289 14.3mag 09:13:38.17 +76:28:18.1 PSN J09133817+7628181 2026-08-09.8037 15.4mag 00:43:17.29 +41:26:48.6 PNV J00431729+4126486 2026-08-14.0920 16.8mag 00:42:52.82 +41:10:58.6 PNV J00425282+4110586 2026-08-17.7723 19.9mag 00:42:52.83 +41:10:59.6 PNV J00425283+4110596 2026-08-18.6119 19.3mag 18:25:12.76 -22:25:29.3 TCP J18251276-2225293 2026-08-19.1062 9.4mag 18:03:09.04 +12:18:14.0 TCP J18030904+1218140 2026-08-19.5199 14.9mag 19:45:06.48 +18:22:42.2 PNV J19450648+1822422 2026-08-25.1278 9.0mag 00:42:54.65 +41:22:59.3 PNV J00425465+4122593 2026-08-25.4712 18.9mag 00:42:50.38 +41:18:58.76 PNV J00425038+4118587 2026-09-04.1512 18.2mag 00:42:12.76 +41:16:28.4 PNV J00421276+4116284 2026-09-10.9176 18.67Cmag 17:52:06.80 -23:43:20.7 TCP J17520680-2343207 2026-09-08.7896 12.6mag -rw-r--r-- 1 apache apache 190K Sep 12 02:24 tocp_transients_list.txt ############################################################ Truncated list of recent TNS transients from https://www.wis-tns.org/ : 00:19:47.538 -07:29:56.79 SN 2026zct 2026-08-15.40 20.5629 20:08:00.800 -36:23:30.80 AT 2026zcs 2026-08-17.03 19.6 23:31:11.619 -10:10:43.21 SN 2026zcr 2026-08-16.37 20.6325 05:52:53.821 +07:37:01.05 AT 2026zcq 2026-08-14.50 20.0603 07:17:15.303 +29:19:27.33 AT 2026zcp 2026-08-17.50 18.8921 20:14:02.721 +03:25:53.97 AT 2026zco 2026-08-16.27 20.1939 19:58:05.847 -04:02:13.06 AT 2026zcn 2026-08-16.20 20.1152 22:55:03.979 -17:24:27.09 AT 2026zcm 2026-08-15.38 20.5686 23:27:56.200 +08:46:45.90 AT 2026zcl 2026-08-13.99 18.9 23:28:51.166 -13:30:18.94 SN 2026zck 2026-08-12.38 20.777 16:53:04.580 +26:53:20.01 AT 2026zcj 2026-08-10.72 21.16 16:50:15.890 +27:00:44.80 AT 2026zci 2026-08-10.72 20.5 16:40:07.820 +21:48:16.82 AT 2026zch 2026-08-06.62 21.55 16:28:44.620 +21:53:08.00 AT 2026zcg 2026-08-06.62 21.63 22:22:34.680 +18:13:14.37 AT 2026zcf 2026-08-04.65 20.66 17:49:07.500 +23:40:53.49 AT 2026zce 2026-08-03.73 21.41 01:44:00.240 +03:30:31.10 AT 2026zcd 2026-08-11.88 22.58 01:22:16.550 +02:43:56.95 AT 2026zcc 2026-08-11.88 22.37 02:16:42.890 +00:36:04.66 AT 2026zcb 2026-08-10.89 22.25 01:56:29.310 +00:47:06.01 AT 2026zca 2026-08-10.89 22.23 -rw-r--r-- 1 apache apache 88K Sep 12 02:24 tns_transients_list.txt

Profiling:

CPU temperature: 89 C