######## Processing parameters ########
AAVSO_COMMENT_STRING= NMW-TexasTech Camera-1 135mm f/2.2 telephoto lens + QHY600M CMOS
ASTCHECK_ASTEROID_SEARCH_RADIUS_ARCSEC=
BAD_REGION_FILE= /var/www/nmw_calibration/TTUQ1b1x1/TTUQ1_bad_region.lst
CAMERA_SETTINGS= TTUQ1b1x1
CHECK_POINTING_ACCURACY= yes
DARK_FRAMES_DIR_OR_FILE= /var/www/nmw_calibration/TTUQ1b1x1/darks
EXCLUSION_LIST= ../exclusion_list_TTUQ1.txt
FILTER_BAD_IMG__MAX_APERTURE_STAR_SIZE_PIX= 12.5
FILTER_BAD_IMG__MAX_ELONGATION_AminusB_PIX= 0.55
FILTER_BAD_IMG__MIN_APERTURE_STAR_SIZE_PIX= 2.0
FILTER_BRIGHT_MAG_CUTOFF_TRANSIENT_SEARCH= -5
FILTER_FAINT_MAG_CUTOFF_TRANSIENT_SEARCH= 15.5
FLAT_FIELD_DIR_OR_FILE= /var/www/nmw_calibration/TTUQ1b1x1/flats
FRAME_EDGE_OFFSET_PIX= 100
GAIA_BAND_FOR_CATALOGED_SOURCE_CHECK=
MAX_NEW_TO_REF_MEAN_IMG_VALUE_RATIO= 100
DISABLE_NEW_TO_REF_MEAN_IMG_RATIO_CHECK= yes
MAX_NEW_IMG_MEAN_VALUE= 25000
MAX_SD_RATIO_OF_SECOND_EPOCH_IMGS= 0.18
MAX_SD_RATIO_OF_SECOND_EPOCH_IMGS_SOFT_LIMIT= 0.12
MPC_CODE= V36
NMW_CALIBRATION= /var/www/nmw_calibration
NUMBER_OF_DETECTED_TRANSIENTS_BEFORE_FILTERING_HARD_LIMIT= 10000
NUMBER_OF_DETECTED_TRANSIENTS_BEFORE_FILTERING_SOFT_LIMIT= 8000
OMP_NUM_THREADS= 3
ONLINE_MPCHECKER_BUTTON_ASTEROID_SEARCH_RADIUS_ARCMIN=
PHOTOMETRIC_CALIBRATION=
REQUIRE_PIX_SHIFT_BETWEEN_IMAGES_FOR_TRANSIENT_CANDIDATES= yes
SEXTRACTOR_CONFIG_BRIGHTSTARPASS= default.sex.telephoto_lens_onlybrightstars_v1
SEXTRACTOR_CONFIG_FILES= default.sex.telephoto_lens_onlybrightstars_v1 default.sex.telephoto_lens_vSTL
STARMATCH_RADIUS_PIX= 5
SYSREM_ITERATIONS= 0
TELESCOP=
TELESCOP_NAME_KNOWN_TO_VaST_FOR_FOV_DETERMINATION=
UCAC5_PLATESOLVE_ITERATIONS= 2
FPACK_FULLY_CALIBRATED_IMAGE= no
#######################################
HOSTNAME= tau
USER=
HOME=
#######################################
SExtractor catalog cache: enabled, directory /data_ssd/NMW-TexasTech/vast_sextractor_cache
Reference image directory is set to /data_ssd/NMW-TexasTech/reference_imgs
VIZIER_SITE=vizier.cds.unistra.fr
GAIA_DR2_CLIENT=vizquery (lib/vizquery -> VizieR vizier.cds.unistra.fr)
INFO: MAKE_PNG_PLOTS is set to yes
FITS_FILE_EXT=fits
CALIBRATION_STATUS_PREFIX=
Fields in the data directory:
Dra-07-Q1b1x1
#######################################
########### Starting Dra-07-Q1b1x1 ###########
Processing Dra-07-Q1b1x1
server tau has sufficient free disk space available: 561043 MB at /data_ssd/NMW-TexasTech/workdir
server tau has sufficient free disk space available: 561043 MB at .
Checking input images (2 new)
REFERENCE_EPOCH__FIRST_IMAGE= /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits
REFERENCE_EPOCH__SECOND_IMAGE= /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits
Small preview (one of the new images): 
Large previews of the second-epoch (new) images:
MAKE_PNG_PLOTS=yes
renamed 'Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.png' -> 'transient_report/Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits_preview.png'
Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits

renamed 'Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.png' -> 'transient_report/Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits_preview.png'
Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits

Read-check the input FITS images... read-check OK
Blank image check the input FITS images... blank-image-check OK
Read date check the input FITS images... read-date-check OK
Mean value check the input FITS images... OK, at least two new images have mean values below the threshold.
----------------------------------------------
INFO: REFERENCE_EPOCH__FIRST_IMAGE_MEAN_VALUE= 398.4182
INFO: REFERENCE_EPOCH__FIRST_IMAGE_SD= 518.6195
INFO: SECOND_EPOCH__FIRST_IMAGE_MEAN_VALUE= 2829.7874
INFO: SECOND_EPOCH__FIRST_IMAGE_SD= 731.8104
INFO: SECOND_EPOCH__SECOND_IMAGE_MEAN_VALUE= 2835.3062
INFO: SECOND_EPOCH__SECOND_IMAGE_SD= 733.4294
----------------------------------------------
INFO: ref_to_second_epoch_img_mean_ratio= 7.10256
INFO: SECOND_EPOCH__SD_ratio= 0.002
INFO: the new-to-reference mean image value ratio check is disabled (DISABLE_NEW_TO_REF_MEAN_IMG_RATIO_CHECK=yes) - expected with a background-subtracted reference image
----------------------------------------------
Calibration settings: DARK_FRAMES_DIR_OR_FILE=/var/www/nmw_calibration/TTUQ1b1x1/darks FLAT_FIELD_DIR_OR_FILE=/var/www/nmw_calibration/TTUQ1b1x1/flats
EXPTIME = 20.0 / [s] Exposure duration
SET-TEMP= 0.0 / [degC] CCD temperature setpoint
CCD-TEMP= -0.0 / [degC] CCD temperature
FOCTEMP = 25.2900009155273 / [degC] Focuser temperature
AMBTEMP = 23.9 / [degC] Ambient air temperature
Exploring image header: /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits
CCD-TEMP= -0.000000 for /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits
SET-TEMP= 0.000000 for /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits
Header: 74 keys total, 33 keys left
Record 0: "" status=0
Record 1: "SIMPLE = T / C# FITS" status=0
Record 2: "BITPIX = 16" status=0
Record 3: "NAXIS = 2 / Dimensionality" status=0
Record 4: "NAXIS1 = 9576" status=0
Record 5: "NAXIS2 = 6388" status=0
Record 6: "BZERO = 32768" status=0
Record 7: "EXTEND = T / Extensions are permitted" status=0
Record 8: "IMAGETYP= 'LIGHT' / Type of exposure" status=0
Record 9: "EXPOSURE= 20.0 / [s] Exposure duration" status=0
Record 10: "EXPTIME = 20.0 / [s] Exposure duration" status=0
Record 11: "DATE-LOC= '2026-08-30T01:46:10.6961537' / Time of observation (local)" status=0
Record 12: "DATE-OBS= '2026-08-30T06:46:10.6961537' / Time of observation (UTC)" status=0
Record 13: "MJD-OBS = 61282.2820682409 / Modified Julian Date of observation" status=0
Record 14: "DATE-AVG= '2026-08-30T06:46:20.5982168' / Averaged midpoint time (UTC)" status=0
Record 15: "MJD-AVG = 61282.2821828471 / Modified Julian Date of averaged midpoint" status=0
Record 16: "XBINNING= 1 / X axis binning factor" status=0
Record 17: "YBINNING= 1 / Y axis binning factor" status=0
Record 18: "GAIN = 30 / Sensor gain" status=0
Record 19: "OFFSET = 30 / Sensor gain offset" status=0
Record 20: "XPIXSZ = 3.76 / [um] Pixel X axis size" status=0
Record 21: "YPIXSZ = 3.76 / [um] Pixel Y axis size" status=0
Record 22: "INSTRUME= 'QHY600M' / Imaging instrument name" status=0
Record 23: "CAMERAID= 'QHY600M-33d3d743814b8b447' / Imaging instrument identifier" status=0
Record 24: "SET-TEMP= 0.0 / [degC] CCD temperature setpoint" status=0
Record 25: "CCD-TEMP= -0.0 / [degC] CCD temperature" status=0
Record 26: "READOUTM= '2CMS-0' / Sensor readout mode" status=0
Record 27: "USBLIMIT= 50 / Camera-specific USB setting" status=0
Record 28: "TELESCOP= 'QHY600M-TTU1' / Name of telescope" status=0
Record 29: "FOCALLEN= 135.0 / [mm] Focal length" status=0
Record 30: "FOCRATIO= 2.2 / Focal ratio" status=0
Record 31: "RA = 257.139228775034 / [deg] RA of telescope" status=0
Record 32: "DEC = 61.9999295781761 / [deg] Declination of telescope" status=0
Record 33: "CENTALT = 33.4972222222222 / [deg] Altitude of telescope" status=0
Record 34: "CENTAZ = 326.186111111111 / [deg] Azimuth of telescope" status=0
Record 35: "AIRMASS = 1.8079879730655 / Airmass at frame center (Gueymard 1993)" status=0
Record 36: "PIERSIDE= 'East' / Telescope pointing state" status=0
Record 37: "SITEELEV= 1015.0 / [m] Observation site elevation" status=0
Record 38: "SITELAT = 33.7480555555556 / [deg] Observation site latitude" status=0
Record 39: "SITELONG= -101.958333333333 / [deg] Observation site longitude" status=0
Record 40: "OBSERVER= 'Sokolovsky' / Observer name" status=0
Record 41: "OBSERVAT= 'TTU Skyview' / Observatory name" status=0
Record 42: "SITENAME= '' / Observatory site name" status=0
Record 43: "FWHEEL = 'Simulator' / Filter Wheel name" status=0
Record 44: "FILTER = 'CV' / Active filter name" status=0
Record 45: "OBJECT = 'Dra-07' / Name of the object of interest" status=0
Record 46: "OBJCTRA = '17 08 34' / [H M S] RA of imaged object" status=0
Record 47: "OBJCTDEC= '+62 00 00' / [D M S] Declination of imaged object" status=0
Record 48: "OBJCTROT= 0.0 / [deg] planned rotation of imaged object" status=0
Record 49: "FOCNAME = 'ZWO Focuser' / Focusing equipment name" status=0
Record 50: "FOCPOS = 29544 / [step] Focuser position" status=0
Record 51: "FOCUSPOS= 29544 / [step] Focuser position" status=0
Record 52: "FOCUSSZ = 0.0 / [um] Focuser step size" status=0
Record 53: "FOCTEMP = 25.2900009155273 / [degC] Focuser temperature" status=0
Record 54: "FOCUSTEM= 25.2900009155273 / [degC] Focuser temperature" status=0
Record 55: "DEWPOINT= 11.2 / [degC] Dew point" status=0
Record 56: "HUMIDITY= 45.0 / [percent] Relative humidity" status=0
Record 57: "PRESSURE= 901.08 / [hPa] Air pressure" status=0
Record 58: "AMBTEMP = 23.9 / [degC] Ambient air temperature" status=0
Record 59: "WINDDIR = 30.0 / [deg] Wind direction: 0=N, 180=S, 90=E, 270=W" status=0
Record 60: "WINDGUST= 7.200576 / [kph] Wind gust" status=0
Record 61: "WINDSPD = 6.100488 / [kph] Wind speed" status=0
Record 62: "ROWORDER= 'TOP-DOWN' / FITS Image Orientation" status=0
Record 63: "EQUINOX = 2000.0 / Equinox of celestial coordinate system" status=0
Record 64: "SWCREATE= 'N.I.N.A. 3.2.0.9001 (x64)' / Software that created this file" status=0
Record 65: "QHY_EXP = 20.000096 / [s] Actual exposure time" status=0
Record 66: "QHY_PP = 13888.0 / [ps] pixelPeriod" status=0
Record 67: "QHY_LP = 85000.0 / [ns] linePeriod" status=0
Record 68: "GPS_LP = 85000.0 / [ns] linePeriod" status=0
Record 69: "QHY_FP = 20000160.0 / [us] framePeriod" status=0
Record 70: "QHY_CPL = 6120.0 / clocksPerLine" status=0
Record 71: "QHY_LPF = 235295.0 / linesPerFrame" status=0
Record 72: "QHY_AET = 20000096.0 / [us] actualExposureTime" status=0
Record 73: "QHY_LEM = T / isLongExposureMode" status=0
Record 74: "QHY_OFF0= 3767.777 / [us] RollingShutterEndOffset row 0" status=0
Allocating memory for image, dark and result arrays...
Reading image /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits 9576 6388 16 bitpix
SET-TEMP= 0.000000 for /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits
SET-TEMP= 0.000000 for /var/www/nmw_calibration/TTUQ1b1x1/darks/mdark_TTUQ1b1x1_0C_20s_2026-08-12_multinight.fit
CCD-TEMP= -0.000000 for /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits
CCD-TEMP= -0.000000 for /var/www/nmw_calibration/TTUQ1b1x1/darks/mdark_TTUQ1b1x1_0C_20s_2026-08-12_multinight.fit
Reading dark frame /var/www/nmw_calibration/TTUQ1b1x1/darks/mdark_TTUQ1b1x1_0C_20s_2026-08-12_multinight.fit 9576 6388 16 bitpix
Dark frame is subtracted, output is written to /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/d_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits :)
Spent 0.493852 seconds
renamed 'mdark_TTUQ1b1x1_0C_20s_2026-08-12_multinight.png' -> 'transient_report/dark.png'
try_to_calibrate_the_input_frame(): selected flat field /var/www/nmw_calibration/TTUQ1b1x1/flats/mff_TTUQ1b1x1_2026-08-12_multinight.fit from directory /var/www/nmw_calibration/TTUQ1b1x1/flats
MegaDivider v7
Reading image /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/d_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits 9576 6388 16 bitpix
Reading flat /var/www/nmw_calibration/TTUQ1b1x1/flats/mff_TTUQ1b1x1_2026-08-12_multinight.fit 9576 6388 16 bitpix
Avarage count on flat field image: 36313.440328
Minimal real count (from overscan): 5
Output is written to /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits :)
No overscan detected - all values seem high! (left_median=23343.0, right_median=27331.5)
renamed 'mff_TTUQ1b1x1_2026-08-12_multinight.png' -> 'transient_report/flat.png'
Using calibrated image CALIBRATED_SECOND_EPOCH__FIRST_IMAGE=/data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits
EXPTIME = 20.0 / [s] Exposure duration
SET-TEMP= 0.0 / [degC] CCD temperature setpoint
CCD-TEMP= 0.0 / [degC] CCD temperature
FOCTEMP = 25.2900009155273 / [degC] Focuser temperature
AMBTEMP = 23.9 / [degC] Ambient air temperature
Exploring image header: /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits
CCD-TEMP= 0.000000 for /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits
SET-TEMP= 0.000000 for /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits
Header: 74 keys total, 33 keys left
Record 0: "" status=0
Record 1: "SIMPLE = T / C# FITS" status=0
Record 2: "BITPIX = 16" status=0
Record 3: "NAXIS = 2 / Dimensionality" status=0
Record 4: "NAXIS1 = 9576" status=0
Record 5: "NAXIS2 = 6388" status=0
Record 6: "BZERO = 32768" status=0
Record 7: "EXTEND = T / Extensions are permitted" status=0
Record 8: "IMAGETYP= 'LIGHT' / Type of exposure" status=0
Record 9: "EXPOSURE= 20.0 / [s] Exposure duration" status=0
Record 10: "EXPTIME = 20.0 / [s] Exposure duration" status=0
Record 11: "DATE-LOC= '2026-08-30T01:47:08.7902188' / Time of observation (local)" status=0
Record 12: "DATE-OBS= '2026-08-30T06:47:08.7902188' / Time of observation (UTC)" status=0
Record 13: "MJD-OBS = 61282.2827406251 / Modified Julian Date of observation" status=0
Record 14: "DATE-AVG= '2026-08-30T06:47:18.6931905' / Averaged midpoint time (UTC)" status=0
Record 15: "MJD-AVG = 61282.282855243 / Modified Julian Date of averaged midpoint" status=0
Record 16: "XBINNING= 1 / X axis binning factor" status=0
Record 17: "YBINNING= 1 / Y axis binning factor" status=0
Record 18: "GAIN = 30 / Sensor gain" status=0
Record 19: "OFFSET = 30 / Sensor gain offset" status=0
Record 20: "XPIXSZ = 3.76 / [um] Pixel X axis size" status=0
Record 21: "YPIXSZ = 3.76 / [um] Pixel Y axis size" status=0
Record 22: "INSTRUME= 'QHY600M' / Imaging instrument name" status=0
Record 23: "CAMERAID= 'QHY600M-33d3d743814b8b447' / Imaging instrument identifier" status=0
Record 24: "SET-TEMP= 0.0 / [degC] CCD temperature setpoint" status=0
Record 25: "CCD-TEMP= 0.0 / [degC] CCD temperature" status=0
Record 26: "READOUTM= '2CMS-0' / Sensor readout mode" status=0
Record 27: "USBLIMIT= 50 / Camera-specific USB setting" status=0
Record 28: "TELESCOP= 'QHY600M-TTU1' / Name of telescope" status=0
Record 29: "FOCALLEN= 135.0 / [mm] Focal length" status=0
Record 30: "FOCRATIO= 2.2 / Focal ratio" status=0
Record 31: "RA = 257.139228908184 / [deg] RA of telescope" status=0
Record 32: "DEC = 61.9999295647312 / [deg] Declination of telescope" status=0
Record 33: "CENTALT = 33.385 / [deg] Altitude of telescope" status=0
Record 34: "CENTAZ = 326.21 / [deg] Azimuth of telescope" status=0
Record 35: "AIRMASS = 1.81332415347761 / Airmass at frame center (Gueymard 1993)" status=0
Record 36: "PIERSIDE= 'East' / Telescope pointing state" status=0
Record 37: "SITEELEV= 1015.0 / [m] Observation site elevation" status=0
Record 38: "SITELAT = 33.7480555555556 / [deg] Observation site latitude" status=0
Record 39: "SITELONG= -101.958333333333 / [deg] Observation site longitude" status=0
Record 40: "OBSERVER= 'Sokolovsky' / Observer name" status=0
Record 41: "OBSERVAT= 'TTU Skyview' / Observatory name" status=0
Record 42: "SITENAME= '' / Observatory site name" status=0
Record 43: "FWHEEL = 'Simulator' / Filter Wheel name" status=0
Record 44: "FILTER = 'CV' / Active filter name" status=0
Record 45: "OBJECT = 'Dra-07' / Name of the object of interest" status=0
Record 46: "OBJCTRA = '17 08 34' / [H M S] RA of imaged object" status=0
Record 47: "OBJCTDEC= '+62 00 00' / [D M S] Declination of imaged object" status=0
Record 48: "OBJCTROT= 0.0 / [deg] planned rotation of imaged object" status=0
Record 49: "FOCNAME = 'ZWO Focuser' / Focusing equipment name" status=0
Record 50: "FOCPOS = 29544 / [step] Focuser position" status=0
Record 51: "FOCUSPOS= 29544 / [step] Focuser position" status=0
Record 52: "FOCUSSZ = 0.0 / [um] Focuser step size" status=0
Record 53: "FOCTEMP = 25.2900009155273 / [degC] Focuser temperature" status=0
Record 54: "FOCUSTEM= 25.2900009155273 / [degC] Focuser temperature" status=0
Record 55: "DEWPOINT= 11.2 / [degC] Dew point" status=0
Record 56: "HUMIDITY= 45.0 / [percent] Relative humidity" status=0
Record 57: "PRESSURE= 901.08 / [hPa] Air pressure" status=0
Record 58: "AMBTEMP = 23.9 / [degC] Ambient air temperature" status=0
Record 59: "WINDDIR = 30.0 / [deg] Wind direction: 0=N, 180=S, 90=E, 270=W" status=0
Record 60: "WINDGUST= 7.200576 / [kph] Wind gust" status=0
Record 61: "WINDSPD = 6.100488 / [kph] Wind speed" status=0
Record 62: "ROWORDER= 'TOP-DOWN' / FITS Image Orientation" status=0
Record 63: "EQUINOX = 2000.0 / Equinox of celestial coordinate system" status=0
Record 64: "SWCREATE= 'N.I.N.A. 3.2.0.9001 (x64)' / Software that created this file" status=0
Record 65: "QHY_EXP = 20.000096 / [s] Actual exposure time" status=0
Record 66: "QHY_PP = 13888.0 / [ps] pixelPeriod" status=0
Record 67: "QHY_LP = 85000.0 / [ns] linePeriod" status=0
Record 68: "GPS_LP = 85000.0 / [ns] linePeriod" status=0
Record 69: "QHY_FP = 20000160.0 / [us] framePeriod" status=0
Record 70: "QHY_CPL = 6120.0 / clocksPerLine" status=0
Record 71: "QHY_LPF = 235295.0 / linesPerFrame" status=0
Record 72: "QHY_AET = 20000096.0 / [us] actualExposureTime" status=0
Record 73: "QHY_LEM = T / isLongExposureMode" status=0
Record 74: "QHY_OFF0= 3767.777 / [us] RollingShutterEndOffset row 0" status=0
Allocating memory for image, dark and result arrays...
Reading image /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits 9576 6388 16 bitpix
SET-TEMP= 0.000000 for /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits
SET-TEMP= 0.000000 for /var/www/nmw_calibration/TTUQ1b1x1/darks/mdark_TTUQ1b1x1_0C_20s_2026-08-12_multinight.fit
CCD-TEMP= 0.000000 for /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits
CCD-TEMP= -0.000000 for /var/www/nmw_calibration/TTUQ1b1x1/darks/mdark_TTUQ1b1x1_0C_20s_2026-08-12_multinight.fit
Reading dark frame /var/www/nmw_calibration/TTUQ1b1x1/darks/mdark_TTUQ1b1x1_0C_20s_2026-08-12_multinight.fit 9576 6388 16 bitpix
Dark frame is subtracted, output is written to /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/d_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits :)
Spent 0.495889 seconds
renamed 'mdark_TTUQ1b1x1_0C_20s_2026-08-12_multinight.png' -> 'transient_report/dark.png'
try_to_calibrate_the_input_frame(): selected flat field /var/www/nmw_calibration/TTUQ1b1x1/flats/mff_TTUQ1b1x1_2026-08-12_multinight.fit from directory /var/www/nmw_calibration/TTUQ1b1x1/flats
MegaDivider v7
Reading image /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/d_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits 9576 6388 16 bitpix
Reading flat /var/www/nmw_calibration/TTUQ1b1x1/flats/mff_TTUQ1b1x1_2026-08-12_multinight.fit 9576 6388 16 bitpix
Avarage count on flat field image: 36313.440328
Minimal real count (from overscan): 5
Output is written to /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits :)
No overscan detected - all values seem high! (left_median=23343.0, right_median=27331.5)
renamed 'mff_TTUQ1b1x1_2026-08-12_multinight.png' -> 'transient_report/flat.png'
Using calibrated image CALIBRATED_SECOND_EPOCH__SECOND_IMAGE=/data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits
Dark frame used to calibrate the second-epoch images:

Flat field used to calibrate the second-epoch images:

after the calibration attempt:
SECOND_EPOCH__FIRST_IMAGE=/data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits
SECOND_EPOCH__SECOND_IMAGE=/data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits
Previews of the CALIBRATED second-epoch images:
fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits

fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits

Updating neverexclude_list.txt
'/var/www/nmw_calibration/neverexclude_list.txt' -> './neverexclude_list.txt'
Choosing bad regions list
'/var/www/nmw_calibration/TTUQ1b1x1/TTUQ1_bad_region.lst' -> 'bad_region.lst'
wait
*------ default.sex.telephoto_lens_onlybrightstars_v1 ------*
'default.sex.telephoto_lens_onlybrightstars_v1' -> 'default.sex'
Starting VaST with default.sex.telephoto_lens_onlybrightstars_v1
./vast --noflagimage --starmatchraius 5 --matchstarnumber 500 --selectbestaperture --sysrem 0 --type 4 --maxsextractorflag 99 --UTC --nofind --nojdkeyword /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits
SExtractor catalog cache: saved Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.cat to cache
SExtractor catalog cache: saved Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits.cat to cache
VaST run complete with default.sex.telephoto_lens_onlybrightstars_v1
The four input images were /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits
Checking WCS cache directory local_wcs_cache
Checking WCS cache directory /mnt/usb/NMW_NG/solved_reference_images
Found WCS cache directory /mnt/usb/NMW_NG/solved_reference_images
Checking WCS cache directory /home/NMW_web_upload/solved_reference_images
Checking WCS cache directory /dataX/kirx/NMW_NG_rt3_autumn2019/solved_reference_images
The reference JD(UT) for computing planet and comet positions: 2461282.78218398
Re-using ../asassn_transients_list.txt
'../asassn_transients_list.txt' -> 'asassn_transients_list.txt'
Re-using ../tocp_transients_list.txt
'../tocp_transients_list.txt' -> 'tocp_transients_list.txt'
Re-using ../tns_transients_list.txt
'../tns_transients_list.txt' -> 'tns_transients_list.txt'
Plate-solving the images
wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits exists and is non-empty
wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits exists and is non-empty
wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits exists and is non-empty
wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits exists and is non-empty
###################################
# fov_of_wcs_calibrated_image.sh output for wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits (1st reference image)
verification OK: wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits
Image size: 937.4'x624.3' 15.6(deg)x10.4(deg) 9576x6388 pix
Image scale: 5.87"/pix along the X axis and 5.86"/pix along the Y axis
Image center: 17:08:33.660 +61:59:46.08 J2000 4789.000 3195.000
###################################
The image scale is 5.87"/pix, setting the soft and hard astrometric limits for filtering second-epoch detections: 5.9" and 8.8"
###################################
# fov_of_wcs_calibrated_image.sh output for wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits (1st new image)
verification OK: wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits
Image size: 941.6'x626.7' 15.7(deg)x10.4(deg) 9576x6388 pix
Image scale: 5.90"/pix along the X axis and 5.89"/pix along the Y axis
Image center: 17:09:06.718 +62:02:57.22 J2000 4789.000 3195.000
###################################
###################################
# Check the image center offset between the reference and the first second-epoch image (pointing accuracy)
Reference image center 17:08:33.660 +61:59:46.08
Second-epoch image center 17:09:06.718 +62:02:57.22
Angular distance between the image centers 0.0836 deg.
Soft limit: 0.50 deg. Hard limit: 1.00 deg.
###################################
###################################
# fov_of_wcs_calibrated_image.sh output for wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits (2nd new image)
verification OK: wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits
Image size: 941.6'x626.7' 15.7(deg)x10.4(deg) 9576x6388 pix
Image scale: 5.90"/pix along the X axis and 5.89"/pix along the Y axis
Image center: 17:09:04.238 +62:03:29.07 J2000 4789.000 3195.000
###################################
###################################
# Check the image center offset between the reference and the second second-epoch image (pointing accuracy)
Reference image center 17:08:33.660 +61:59:46.08
Second-epoch image center 17:09:04.238 +62:03:29.07
Angular distance between the image centers 0.0861 deg.
###################################
###################################
# Check the image center offset between the first and the second second-epoch image (shift should be applied between the second-epoch images)
Second-epoch first image center 17:09:06.718 +62:02:57.22
Second-epoch second image center 17:09:04.238 +62:03:29.07
Angular distance between the image centers 0.01009 deg.
###################################
Running solve_plate_with_UCAC5...
Preparing for a parallel run
Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits &> /tmp/tmp.DpLG1kz9sU
Parallel run for /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits
Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits &> /tmp/tmp.KUjx7uyc4r
Parallel run for /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits
Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits &> /tmp/tmp.OYRDpwknqq
Parallel run for /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits
Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits &> /tmp/tmp.ZhPRLRXAjF
Parallel run for /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits
Calibrating the magnitude scale
Found non-empty wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits
____ Start of magnitude calibration ____
PHOTOMETRIC_CALIBRATION=TYCHO2_V
Calibrating the magnitude scale with Tycho-2 stars
util/transients/transient_factory_test31.sh is checking for the presence of non-empty wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits and wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat
wait (drain background util/solve_plate_with_UCAC5 jobs before Tycho-2 calibration -- avoids wcs_.fits write race)
Tycho-2 catalog is found at lib/catalogs/tycho2
Tycho-2 catalog and the derived bright star exclusion list are ready
Checking for the presence of non-empty wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits and wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat
Found non-empty wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits and wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat
The reference image (wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits) and catalog (wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat) found
'wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat' -> 'wcsmag.cat'
Read 10895 stars from the SExtractor catalog wcsmag.cat
Detected star coordinate range: RA 237.9599 to 276.7126 deg, Dec +55.8532 to +67.2637 deg
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.00
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.01
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.02
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.03
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.04
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.05
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.06
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.07
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.08
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.09
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.10
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.11
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.12
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.13
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.14
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.15
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.16
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.17
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.18
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.19
Tycho-2 catalog search boundaries: RA 237.9599 to 276.7126 deg, Dec 55.8532 to 67.2637 deg
Loaded 9346 Tycho-2 stars within the image boundaries (VT and BT non-zero).
Relation between the catalog and instrumental magnitudes is written to calib.txt
Stars used for magnitude calibration (good matches): 5972 out of 6265 total matches.
Matched with Tycho-2 6265 out of 10895 detected stars.
The calibration function type and coefficients are written to calib.txt_param
util/calibrate_magnitude_scale 0.000000 1.000000 22.687350
a=0.000000 b=1.000000 c=22.687350
From vast_summary.log: estimated ref. image limiting mag.: -7.41
Updating vast_summary.log: Estimated ref. image limiting mag.: 15.28
Updated vast_limiting_magnitude.log with calibrated magnitudes
Working...
Please, PLEASE, be patient!!!
All lightcurves processed! =)
Estimated ref. image limiting mag.: 15.28
Lightcurve magnitude calibration plot:

Preparing per-reference-image forced-photometry calibration (method=tycho2 band=V)
Read 10895 stars from the SExtractor catalog wcsmag.cat
Detected star coordinate range: RA 237.9599 to 276.7126 deg, Dec +55.8532 to +67.2637 deg
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.00
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.01
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.02
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.03
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.04
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.05
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.06
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.07
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.08
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.09
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.10
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.11
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.12
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.13
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.14
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.15
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.16
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.17
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.18
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.19
Tycho-2 catalog search boundaries: RA 237.9599 to 276.7126 deg, Dec 55.8532 to 67.2637 deg
Loaded 9346 Tycho-2 stars within the image boundaries (VT and BT non-zero).
Relation between the catalog and instrumental magnitudes is written to calib.txt
Stars used for magnitude calibration (good matches): 5972 out of 6265 total matches.
Matched with Tycho-2 6265 out of 10895 detected stars.
util/calibrate_single_image_with_tycho2.sh: calibrated wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits via Tycho-2
Single-image forced-photometry magnitude calibration plot for wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits:

Forced-photometry filter: reusing the VaST-run aperture from image00001.cat.aperture for wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits
Forced-photometry filter: calibrated wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits -> calib.txt_param_ref_wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits (aperture=6.5)
Read 10980 stars from the SExtractor catalog wcsmag.cat
Detected star coordinate range: RA 237.9599 to 276.7127 deg, Dec +55.8529 to +67.2538 deg
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.00
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.01
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.02
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.03
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.04
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.05
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.06
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.07
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.08
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.09
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.10
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.11
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.12
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.13
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.14
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.15
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.16
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.17
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.18
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.19
Tycho-2 catalog search boundaries: RA 237.9599 to 276.7127 deg, Dec 55.8529 to 67.2538 deg
Loaded 9334 Tycho-2 stars within the image boundaries (VT and BT non-zero).
Relation between the catalog and instrumental magnitudes is written to calib.txt
Stars used for magnitude calibration (good matches): 5977 out of 6269 total matches.
Matched with Tycho-2 6269 out of 10980 detected stars.
util/calibrate_single_image_with_tycho2.sh: calibrated wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits via Tycho-2
Single-image forced-photometry magnitude calibration plot for wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits:

Forced-photometry filter: reusing the VaST-run aperture from image00002.cat.aperture for wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits
Forced-photometry filter: calibrated wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits -> calib.txt_param_ref_wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits (aperture=6.5)
____ End of magnitude calibration ____
Applying consolidated magnitude filters...
Preparing the exclusion lists for this field
Done with filtering
Found 2 candidate transients before the final filtering. (Hard limit: 10000)
Median FWHM seeing for isolated stars:
2.3 pix Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits
2.3 pix Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits
2.2 pix fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits
2.1 pix fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits
Limiting magnitude estimates:
15.3 mag. Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits
15.3 mag. Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits
14.3 mag. fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits
14.3 mag. fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits
All-image limiting magnitude estimate: 14.3 (SNR ) 11.3 (80% of stars) with default.sex.telephoto_lens_onlybrightstars_v1
The first estimate is the magnitude of a star detected with a signal-to-noise ratio of following Karpov (2025, Acta Polytechnica, 65, 50).
This value should be representative of the faintest stars clearly visible in the image.
The brighter of the limiting magnitude estimates for the two second-epoch images is reported here.
The second estimate is the 80th percentile of the magnitude distribution of stars detected on all four images.
This value is representative of the faintest object that may enter the candidate transients list.
The hard cut-off for the candidate transients is 15.5 mag.
Waiting for UCAC5 plate solver
wait
cp: cannot create regular file 'local_wcs_cache/': Not a directory
############ /tmp/tmp.DpLG1kz9sU (6) ############
Parsing command line arguments...
WARNING from replace_file_with_symlink_if_filename_contains_white_spaces() the input file /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits is already a symlink and we do not allow symlinks on symlinks
The guess is based on the existing WCS header.
Trying to blindly solve the plate (local solve-field or remote server)...
/data_ssd/NMW-TexasTech/workdir/vast_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits 571.0
Entering WCS image calibration mode.
ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits
FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits
WARNING from replace_file_with_symlink_if_filename_contains_white_spaces() the input file /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits is already a symlink and we do not allow symlinks on symlinks
FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits
verification OK: /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits
It's a known telescope with plate solutions that are supposed to be good.
The input image /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits has a WCS header - will blindly trust it is good...
'/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits' -> 'wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits'
This WCS solution (astrometrynet) will be kept as is, not refit by util/solve_plate_with_UCAC5
FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits
WCS_IMAGE_NAME=wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits
WCS-calibrated image found: wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits
Checking if the catalog wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat corresponding to the image wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits alredy exist and is non-empty...
Catalog wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat corresponding to the image wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits found.
The catalog is in the new format, as expected.
The plate-solved (WCS-calibrated) image is saved to wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits
util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits
WCS catalog name: wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat
Excluding image region: 190.0 1039.0 192.0 1041.0 (defined in bad_region.lst)
Excluding image region: 226.0 1548.0 228.0 1550.0 (defined in bad_region.lst)
Excluding image region: 351.0 1875.0 353.0 1877.0 (defined in bad_region.lst)
Excluding image region: 501.0 5912.0 503.0 5914.0 (defined in bad_region.lst)
Excluding image region: 638.0 5545.0 640.0 5547.0 (defined in bad_region.lst)
Excluding image region: 724.0 2731.0 726.0 2733.0 (defined in bad_region.lst)
Excluding image region: 883.0 1376.0 885.0 1378.0 (defined in bad_region.lst)
Excluding image region: 901.0 3972.0 903.0 3974.0 (defined in bad_region.lst)
Excluding image region: 1151.0 918.0 1153.0 920.0 (defined in bad_region.lst)
Excluding image region: 1157.0 135.0 1159.0 137.0 (defined in bad_region.lst)
Excluding more image regions!.. (will not print them all)
Excluded a total of 50 image regions (defined in bad_region.lst).
SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=0, blended=730, bad_region=0, passed=10895
Got 10895 stars (including 10157 good ones) from the SExtractor catalog wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat
util/solve_plate_with_UCAC5 got 10895 stars from the SExtractor catalog
Updated FoV from the plate-solved image: 937.4'
Seting catalog search parameters based on the expected field of view 937.4 arcmin
UCAC5 catalog search parameters:
catalog_search_parameters->search_radius_deg= 0.013019 (46.9 arcsec)
catalog_search_parameters->brightest_mag= 1.00
catalog_search_parameters->faintest_mag= 13.50
catalog_search_parameters->search_radius_second_step_deg 0.010416 (37.5 arcsec)
ITERATION 01 -- talking to VizieR, this might be slow!
UCAC5 search strategy: trying local copy first
Found a local copy of UCAC5
UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50
Reading UCAC5 zone files...
Searching UCAC5 zones 729 to 788 (Dec 55.9 to 67.3)
Done reading UCAC5 zone files...
Matched 4913 stars with the local copy of UCAC5.
The local UCAC5 search seems to be a success
Correcting the measured astrometric positions...
Accuracy estimation diagnostic: 4903 matched stars entering correct_measured_positions(), 4903 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.37"
Removing outliers...
Correcting the measured astrometric positions...
Accuracy estimation diagnostic: 4903 matched stars entering correct_measured_positions(), 10895 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.37"
ITERATION 02 -- talking to VizieR, this might be slow!
UCAC5 search strategy: trying local copy first
Found a local copy of UCAC5
UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50
Reading UCAC5 zone files...
Searching UCAC5 zones 729 to 788 (Dec 55.9 to 67.3)
Done reading UCAC5 zone files...
Matched 4913 stars with the local copy of UCAC5.
The local UCAC5 search seems to be a success
Accuracy estimation diagnostic: 4903 matched stars entering correct_measured_positions(), 10895 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.38"
Accuracy estimation diagnostic: 4903 matched stars entering correct_measured_positions(), 10895 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.40"
Excluding outliers - 4903 stars left (next iteration limit 5393)
Stop iterations.
The field is successfully solved and matched with the astrometric catalog! :)
SIP_REFIT: util/identify.sh trusts the WCS of wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits (astrometrynet) - keeping it, no refit (set VAST_FORCE_SIP_REFIT=1 to refit anyway)
WCS_QUALITY_DIAG: file=Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits N_match=4903 sigma_overall_arcsec=0.426 sigma_q1_arcsec=0.372 sigma_q2_arcsec=0.460 sigma_q3_arcsec=0.495 sigma_q4_arcsec=0.402 n_q1=1378 n_q2=1176 n_q3=1215 n_q4=1134 worst_quadrant_to_overall_ratio=1.161
The image catalog is written to wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat.ucac5
The DS9 region file with the matched stars is written to wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat.ds9.reg
You may view it with the command:
ds9 /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits -region wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat.ds9.reg
The astrometric residuals vector field is written to wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat.astrometric_residuals
Option '-n' not using photometric catalogs, just stick with astrometry
opt '-i': 2 is the maximum number of iterations
FORCED_PHOTOMETRY_CALIBRATION_METHOD=tycho2 - not using remote photometric catalogs, just stick with astrometry
############ /tmp/tmp.KUjx7uyc4r (6) ############
Parsing command line arguments...
WARNING from replace_file_with_symlink_if_filename_contains_white_spaces() the input file /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits is already a symlink and we do not allow symlinks on symlinks
The guess is based on the existing WCS header.
Trying to blindly solve the plate (local solve-field or remote server)...
/data_ssd/NMW-TexasTech/workdir/vast_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits 571.0
Entering WCS image calibration mode.
ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits
FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits
WARNING from replace_file_with_symlink_if_filename_contains_white_spaces() the input file /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits is already a symlink and we do not allow symlinks on symlinks
FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits
verification OK: /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits
It's a known telescope with plate solutions that are supposed to be good.
The input image /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits has a WCS header - will blindly trust it is good...
'/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits' -> 'wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits'
This WCS solution (astrometrynet) will be kept as is, not refit by util/solve_plate_with_UCAC5
FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits
WCS_IMAGE_NAME=wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits
WCS-calibrated image found: wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits
Checking if the catalog wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits.wcscat corresponding to the image wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits alredy exist and is non-empty...
Catalog wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits.wcscat corresponding to the image wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits found.
The catalog is in the new format, as expected.
The plate-solved (WCS-calibrated) image is saved to wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits
util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits
WCS catalog name: wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits.wcscat
Excluding image region: 190.0 1039.0 192.0 1041.0 (defined in bad_region.lst)
Excluding image region: 226.0 1548.0 228.0 1550.0 (defined in bad_region.lst)
Excluding image region: 351.0 1875.0 353.0 1877.0 (defined in bad_region.lst)
Excluding image region: 501.0 5912.0 503.0 5914.0 (defined in bad_region.lst)
Excluding image region: 638.0 5545.0 640.0 5547.0 (defined in bad_region.lst)
Excluding image region: 724.0 2731.0 726.0 2733.0 (defined in bad_region.lst)
Excluding image region: 883.0 1376.0 885.0 1378.0 (defined in bad_region.lst)
Excluding image region: 901.0 3972.0 903.0 3974.0 (defined in bad_region.lst)
Excluding image region: 1151.0 918.0 1153.0 920.0 (defined in bad_region.lst)
Excluding image region: 1157.0 135.0 1159.0 137.0 (defined in bad_region.lst)
Excluding more image regions!.. (will not print them all)
Excluded a total of 50 image regions (defined in bad_region.lst).
SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=0, blended=731, bad_region=0, passed=10980
Got 10980 stars (including 10231 good ones) from the SExtractor catalog wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits.wcscat
util/solve_plate_with_UCAC5 got 10980 stars from the SExtractor catalog
Updated FoV from the plate-solved image: 937.3'
Seting catalog search parameters based on the expected field of view 937.3 arcmin
UCAC5 catalog search parameters:
catalog_search_parameters->search_radius_deg= 0.013018 (46.9 arcsec)
catalog_search_parameters->brightest_mag= 1.00
catalog_search_parameters->faintest_mag= 13.50
catalog_search_parameters->search_radius_second_step_deg 0.010414 (37.5 arcsec)
ITERATION 01 -- talking to VizieR, this might be slow!
UCAC5 search strategy: trying local copy first
Found a local copy of UCAC5
UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50
Reading UCAC5 zone files...
Searching UCAC5 zones 729 to 788 (Dec 55.9 to 67.3)
Done reading UCAC5 zone files...
Matched 4914 stars with the local copy of UCAC5.
The local UCAC5 search seems to be a success
Correcting the measured astrometric positions...
Accuracy estimation diagnostic: 4904 matched stars entering correct_measured_positions(), 4904 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.36"
Removing outliers...
Correcting the measured astrometric positions...
Accuracy estimation diagnostic: 4904 matched stars entering correct_measured_positions(), 10980 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.36"
ITERATION 02 -- talking to VizieR, this might be slow!
UCAC5 search strategy: trying local copy first
Found a local copy of UCAC5
UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50
Reading UCAC5 zone files...
Searching UCAC5 zones 729 to 788 (Dec 55.9 to 67.3)
Done reading UCAC5 zone files...
Matched 4914 stars with the local copy of UCAC5.
The local UCAC5 search seems to be a success
Accuracy estimation diagnostic: 4904 matched stars entering correct_measured_positions(), 10980 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.37"
Accuracy estimation diagnostic: 4904 matched stars entering correct_measured_positions(), 10980 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.38"
Excluding outliers - 4904 stars left (next iteration limit 5394)
Stop iterations.
The field is successfully solved and matched with the astrometric catalog! :)
SIP_REFIT: util/identify.sh trusts the WCS of wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits (astrometrynet) - keeping it, no refit (set VAST_FORCE_SIP_REFIT=1 to refit anyway)
WCS_QUALITY_DIAG: file=Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits N_match=4904 sigma_overall_arcsec=0.397 sigma_q1_arcsec=0.344 sigma_q2_arcsec=0.439 sigma_q3_arcsec=0.469 sigma_q4_arcsec=0.370 n_q1=1378 n_q2=1177 n_q3=1213 n_q4=1136 worst_quadrant_to_overall_ratio=1.182
The image catalog is written to wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits.wcscat.ucac5
The DS9 region file with the matched stars is written to wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits.wcscat.ds9.reg
You may view it with the command:
ds9 /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits -region wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits.wcscat.ds9.reg
The astrometric residuals vector field is written to wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits.wcscat.astrometric_residuals
Option '-n' not using photometric catalogs, just stick with astrometry
opt '-i': 2 is the maximum number of iterations
FORCED_PHOTOMETRY_CALIBRATION_METHOD=tycho2 - not using remote photometric catalogs, just stick with astrometry
############ /tmp/tmp.OYRDpwknqq (6) ############
Parsing command line arguments...
The minor axis of the CCD chip should be 24.0 mm based on the derived pixel size of 3.8 um
Internal estimated FoV 605.3'
The guess is based on the FOCALLEN keyword.
Trying to blindly solve the plate (local solve-field or remote server)...
/data_ssd/NMW-TexasTech/workdir/vast_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits 605.0
Entering WCS image calibration mode.
ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits
FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits
FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits
verification OK: /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits
It's not one of the telescopes that are know to produce images with good WCS solutions - will try to re-solve!
FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits
WCS_IMAGE_NAME=wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits
WCS-calibrated image found: wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits
Checking if the catalog wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits.wcscat corresponding to the image wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits alredy exist and is non-empty...
Catalog wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits.wcscat corresponding to the image wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits found.
The catalog is in the new format, as expected.
The plate-solved (WCS-calibrated) image is saved to wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits
util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits
WCS catalog name: wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits.wcscat
Excluding image region: 190.0 1039.0 192.0 1041.0 (defined in bad_region.lst)
Excluding image region: 226.0 1548.0 228.0 1550.0 (defined in bad_region.lst)
Excluding image region: 351.0 1875.0 353.0 1877.0 (defined in bad_region.lst)
Excluding image region: 501.0 5912.0 503.0 5914.0 (defined in bad_region.lst)
Excluding image region: 638.0 5545.0 640.0 5547.0 (defined in bad_region.lst)
Excluding image region: 724.0 2731.0 726.0 2733.0 (defined in bad_region.lst)
Excluding image region: 883.0 1376.0 885.0 1378.0 (defined in bad_region.lst)
Excluding image region: 901.0 3972.0 903.0 3974.0 (defined in bad_region.lst)
Excluding image region: 1151.0 918.0 1153.0 920.0 (defined in bad_region.lst)
Excluding image region: 1157.0 135.0 1159.0 137.0 (defined in bad_region.lst)
Excluding more image regions!.. (will not print them all)
Excluded a total of 50 image regions (defined in bad_region.lst).
SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=0, blended=435, bad_region=0, passed=5127
Got 5127 stars (including 4688 good ones) from the SExtractor catalog wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits.wcscat
util/solve_plate_with_UCAC5 got 5127 stars from the SExtractor catalog
Updated FoV from the plate-solved image: 941.6'
Seting catalog search parameters based on the expected field of view 941.6 arcmin
UCAC5 catalog search parameters:
catalog_search_parameters->search_radius_deg= 0.013078 (47.1 arcsec)
catalog_search_parameters->brightest_mag= 1.00
catalog_search_parameters->faintest_mag= 13.50
catalog_search_parameters->search_radius_second_step_deg 0.010462 (37.7 arcsec)
ITERATION 01 -- talking to VizieR, this might be slow!
UCAC5 search strategy: trying local copy first
Found a local copy of UCAC5
UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50
Reading UCAC5 zone files...
Searching UCAC5 zones 728 to 788 (Dec 55.6 to 67.4)
Done reading UCAC5 zone files...
Matched 4597 stars with the local copy of UCAC5.
The local UCAC5 search seems to be a success
Correcting the measured astrometric positions...
Accuracy estimation diagnostic: 4586 matched stars entering correct_measured_positions(), 4586 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.27"
Removing outliers...
Correcting the measured astrometric positions...
Accuracy estimation diagnostic: 4586 matched stars entering correct_measured_positions(), 5127 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.27"
ITERATION 02 -- talking to VizieR, this might be slow!
UCAC5 search strategy: trying local copy first
Found a local copy of UCAC5
UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50
Reading UCAC5 zone files...
Searching UCAC5 zones 728 to 788 (Dec 55.6 to 67.4)
Done reading UCAC5 zone files...
Matched 4598 stars with the local copy of UCAC5.
The local UCAC5 search seems to be a success
Accuracy estimation diagnostic: 4587 matched stars entering correct_measured_positions(), 5127 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.27"
Accuracy estimation diagnostic: 4587 matched stars entering correct_measured_positions(), 5127 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.27"
Excluding outliers - 4587 stars left (next iteration limit 5044)
Stop iterations.
The field is successfully solved and matched with the astrometric catalog! :)
SIP_REFIT: SIP order 2 trial: matched=4587 robust_rms=10.928 arcsec worst_quadrant_rms=14.953 arcsec
SIP_REFIT: SIP order 3 trial: matched=4587 robust_rms=0.466 arcsec worst_quadrant_rms=0.504 arcsec
SIP_REFIT: SIP order 5 trial: matched=4587 robust_rms=0.286 arcsec worst_quadrant_rms=0.314 arcsec
SIP_REFIT: selected SIP order 5
SIP_REFIT: order=5 matched=4587 robust_rms_before=0.725 arcsec robust_rms_before_corrected=0.288 arcsec robust_rms_after=0.286 arcsec worst_quadrant_rms_before=0.307 worst_quadrant_rms_after=0.314
SIP_REFIT: refit does not sufficiently improve on the solution it would replace (best worst-quadrant baseline 0.307 arcsec) - keeping the original
WCS_QUALITY_DIAG: file=fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits N_match=4587 sigma_overall_arcsec=0.292 sigma_q1_arcsec=0.295 sigma_q2_arcsec=0.302 sigma_q3_arcsec=0.293 sigma_q4_arcsec=0.260 n_q1=1272 n_q2=999 n_q3=1275 n_q4=1041 worst_quadrant_to_overall_ratio=1.034
The image catalog is written to wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits.wcscat.ucac5
The DS9 region file with the matched stars is written to wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits.wcscat.ds9.reg
You may view it with the command:
ds9 /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits -region wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits.wcscat.ds9.reg
The astrometric residuals vector field is written to wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits.wcscat.astrometric_residuals
Option '-n' not using photometric catalogs, just stick with astrometry
opt '-i': 2 is the maximum number of iterations
FORCED_PHOTOMETRY_CALIBRATION_METHOD=tycho2 - not using remote photometric catalogs, just stick with astrometry
############ /tmp/tmp.ZhPRLRXAjF (6) ############
Parsing command line arguments...
The minor axis of the CCD chip should be 24.0 mm based on the derived pixel size of 3.8 um
Internal estimated FoV 605.3'
The guess is based on the FOCALLEN keyword.
Trying to blindly solve the plate (local solve-field or remote server)...
/data_ssd/NMW-TexasTech/workdir/vast_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits 605.0
Entering WCS image calibration mode.
ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits
FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits
FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits
verification OK: /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits
It's not one of the telescopes that are know to produce images with good WCS solutions - will try to re-solve!
FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits
WCS_IMAGE_NAME=wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits
WCS-calibrated image found: wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits
Checking if the catalog wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits.wcscat corresponding to the image wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits alredy exist and is non-empty...
Catalog wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits.wcscat corresponding to the image wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits found.
The catalog is in the new format, as expected.
The plate-solved (WCS-calibrated) image is saved to wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits
util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits
WCS catalog name: wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits.wcscat
Excluding image region: 190.0 1039.0 192.0 1041.0 (defined in bad_region.lst)
Excluding image region: 226.0 1548.0 228.0 1550.0 (defined in bad_region.lst)
Excluding image region: 351.0 1875.0 353.0 1877.0 (defined in bad_region.lst)
Excluding image region: 501.0 5912.0 503.0 5914.0 (defined in bad_region.lst)
Excluding image region: 638.0 5545.0 640.0 5547.0 (defined in bad_region.lst)
Excluding image region: 724.0 2731.0 726.0 2733.0 (defined in bad_region.lst)
Excluding image region: 883.0 1376.0 885.0 1378.0 (defined in bad_region.lst)
Excluding image region: 901.0 3972.0 903.0 3974.0 (defined in bad_region.lst)
Excluding image region: 1151.0 918.0 1153.0 920.0 (defined in bad_region.lst)
Excluding image region: 1157.0 135.0 1159.0 137.0 (defined in bad_region.lst)
Excluding more image regions!.. (will not print them all)
Excluded a total of 50 image regions (defined in bad_region.lst).
SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=0, blended=418, bad_region=0, passed=5098
Got 5098 stars (including 4675 good ones) from the SExtractor catalog wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits.wcscat
util/solve_plate_with_UCAC5 got 5098 stars from the SExtractor catalog
Updated FoV from the plate-solved image: 941.6'
Seting catalog search parameters based on the expected field of view 941.6 arcmin
UCAC5 catalog search parameters:
catalog_search_parameters->search_radius_deg= 0.013078 (47.1 arcsec)
catalog_search_parameters->brightest_mag= 1.00
catalog_search_parameters->faintest_mag= 13.50
catalog_search_parameters->search_radius_second_step_deg 0.010462 (37.7 arcsec)
ITERATION 01 -- talking to VizieR, this might be slow!
UCAC5 search strategy: trying local copy first
Found a local copy of UCAC5
UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50
Reading UCAC5 zone files...
Searching UCAC5 zones 728 to 788 (Dec 55.6 to 67.4)
Done reading UCAC5 zone files...
Matched 4582 stars with the local copy of UCAC5.
The local UCAC5 search seems to be a success
Correcting the measured astrometric positions...
Accuracy estimation diagnostic: 4572 matched stars entering correct_measured_positions(), 4572 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.27"
Removing outliers...
Correcting the measured astrometric positions...
Accuracy estimation diagnostic: 4572 matched stars entering correct_measured_positions(), 5098 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.27"
ITERATION 02 -- talking to VizieR, this might be slow!
UCAC5 search strategy: trying local copy first
Found a local copy of UCAC5
UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50
Reading UCAC5 zone files...
Searching UCAC5 zones 728 to 788 (Dec 55.6 to 67.4)
Done reading UCAC5 zone files...
Matched 4582 stars with the local copy of UCAC5.
The local UCAC5 search seems to be a success
Accuracy estimation diagnostic: 4571 matched stars entering correct_measured_positions(), 5098 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.27"
Accuracy estimation diagnostic: 4571 matched stars entering correct_measured_positions(), 5098 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.27"
Excluding outliers - 4571 stars left (next iteration limit 5029)
Stop iterations.
The field is successfully solved and matched with the astrometric catalog! :)
SIP_REFIT: SIP order 2 trial: matched=4571 robust_rms=10.796 arcsec worst_quadrant_rms=15.589 arcsec
SIP_REFIT: SIP order 3 trial: matched=4571 robust_rms=0.462 arcsec worst_quadrant_rms=0.520 arcsec
SIP_REFIT: SIP order 5 trial: matched=4571 robust_rms=0.291 arcsec worst_quadrant_rms=0.309 arcsec
SIP_REFIT: selected SIP order 5
SIP_REFIT: order=5 matched=4571 robust_rms_before=0.697 arcsec robust_rms_before_corrected=0.288 arcsec robust_rms_after=0.291 arcsec worst_quadrant_rms_before=0.306 worst_quadrant_rms_after=0.309
SIP_REFIT: refit does not sufficiently improve on the solution it would replace (best worst-quadrant baseline 0.306 arcsec) - keeping the original
WCS_QUALITY_DIAG: file=fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits N_match=4571 sigma_overall_arcsec=0.293 sigma_q1_arcsec=0.296 sigma_q2_arcsec=0.309 sigma_q3_arcsec=0.297 sigma_q4_arcsec=0.272 n_q1=1273 n_q2=994 n_q3=1266 n_q4=1038 worst_quadrant_to_overall_ratio=1.055
The image catalog is written to wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits.wcscat.ucac5
The DS9 region file with the matched stars is written to wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits.wcscat.ds9.reg
You may view it with the command:
ds9 /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits -region wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits.wcscat.ds9.reg
The astrometric residuals vector field is written to wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits.wcscat.astrometric_residuals
Option '-n' not using photometric catalogs, just stick with astrometry
opt '-i': 2 is the maximum number of iterations
FORCED_PHOTOMETRY_CALIBRATION_METHOD=tycho2 - not using remote photometric catalogs, just stick with astrometry
Saving the final (post-refit) wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits to local_wcs_cache/
'wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits' -> 'local_wcs_cache/wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits'
Saving the final (post-refit) wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits to local_wcs_cache/
'wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits' -> 'local_wcs_cache/wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits'
Saving the final (post-refit) wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits to local_wcs_cache/
'wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits' -> 'local_wcs_cache/wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits'
Saving the final (post-refit) wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits to local_wcs_cache/
'wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits' -> 'local_wcs_cache/wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits'
###################################
# Pre-local-correction WCS quality summary (see WCS_QUALITY_DIAG lines above)
ref1=Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits sigma_overall=0.426 worst_q_ratio=1.161
ref2=Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits sigma_overall=0.397 worst_q_ratio=1.182
new1=fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits sigma_overall=0.292 worst_q_ratio=1.034
new2=fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits sigma_overall=0.293 worst_q_ratio=1.055
reference average sigma_overall=0.4115 worst_q_ratio=1.1715
warn-on-ratio threshold: 2.0x reference
###################################
Astrometric residual vector field (catalog-matched stars):
plot_astrometric_residuals_xy.py: wrote wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245_astrometric_residuals.png (4903 matched stars from wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat.astrometric_residuals, image 9576x6388, median residual 0.37 arcsec)

plot_astrometric_residuals_xy.py: wrote wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270_astrometric_residuals.png (4904 matched stars from wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits.wcscat.astrometric_residuals, image 9576x6388, median residual 0.35 arcsec)

plot_astrometric_residuals_xy.py: wrote wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162_astrometric_residuals.png (4587 matched stars from wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits.wcscat.astrometric_residuals, image 9576x6388, median residual 0.26 arcsec)

plot_astrometric_residuals_xy.py: wrote wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163_astrometric_residuals.png (4571 matched stars from wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits.wcscat.astrometric_residuals, image 9576x6388, median residual 0.26 arcsec)

Copying WCS-calibrated images back to input directory
Saving fully-calibrated image wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits
INFO: FPACK_FULLY_CALIBRATED_IMAGE=no (not compressing the image)
'wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits' -> '/data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits'
Saving fully-calibrated image wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits
INFO: FPACK_FULLY_CALIBRATED_IMAGE=no (not compressing the image)
'wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits' -> '/data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits'
Preparing the HTML report for the field Dra-07-Q1b1x1 with default.sex.telephoto_lens_onlybrightstars_v1
make_report_in_HTML.sh Phase 1 (network queries): 1s
Pre-generating preview images in parallel...
Done pre-generating preview images.
Pre-generating finding charts in parallel...
Done pre-generating finding charts.
make_report_in_HTML.sh Pre-generation: 0s
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 04197_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 04197_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 3 | 2026 08 30.28286 | 2461282.78286 | 11.12 | 17:07:12.76 +63:21:22.1 | 4968 2424 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
**** FOUND 17:07:12.77 +63:21:22.0 in the exclusion list exclusion_list.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 00315_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 00315_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 3 | 2026 08 30.28286 | 2461282.78286 | 7.54 | 16:32:40.39 +66:45:16.2 | 7157 0355 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
**** FOUND 16:32:40.40 +66:45:16.3 in the exclusion list exclusion_list.txt ****
make_report_in_HTML.sh Phase 2 (HTML assembly): 0s
make_report_in_HTML.sh TOTAL: 1s
Prepared the HTML report for the field Dra-07-Q1b1x1 with default.sex.telephoto_lens_onlybrightstars_v1
*------ done with default.sex.telephoto_lens_onlybrightstars_v1 ------*
#### The local exclusion list is exclusion_list_local.txt ####
wait
*------ default.sex.telephoto_lens_vSTL ------*
'default.sex.telephoto_lens_vSTL' -> 'default.sex'
Starting VaST with default.sex.telephoto_lens_vSTL
./vast --noflagimage --starmatchraius 5 --matchstarnumber 500 --selectbestaperture --sysrem 0 --type 4 --maxsextractorflag 99 --UTC --nofind --nojdkeyword /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits
SExtractor catalog cache: saved Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.cat to cache
SExtractor catalog cache: saved Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits.cat to cache
VaST run complete with default.sex.telephoto_lens_vSTL
The four input images were /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits
Checking WCS cache directory local_wcs_cache
Found WCS cache directory local_wcs_cache
Creating symlink local_wcs_cache/wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits
Creating symlink local_wcs_cache/wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits
Creating symlink local_wcs_cache/wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits
Creating symlink local_wcs_cache/wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits
Checking WCS cache directory /mnt/usb/NMW_NG/solved_reference_images
Found WCS cache directory /mnt/usb/NMW_NG/solved_reference_images
Checking WCS cache directory /home/NMW_web_upload/solved_reference_images
Checking WCS cache directory /dataX/kirx/NMW_NG_rt3_autumn2019/solved_reference_images
Plate-solving the images
wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits exists and is non-empty
wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits exists and is non-empty
wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits exists and is non-empty
wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits exists and is non-empty
###################################
# fov_of_wcs_calibrated_image.sh output for wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits (1st reference image)
verification OK: wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits
Image size: 937.4'x624.3' 15.6(deg)x10.4(deg) 9576x6388 pix
Image scale: 5.87"/pix along the X axis and 5.86"/pix along the Y axis
Image center: 17:08:33.660 +61:59:46.08 J2000 4789.000 3195.000
###################################
The image scale is 5.87"/pix, setting the soft and hard astrometric limits for filtering second-epoch detections: 5.9" and 8.8"
###################################
# fov_of_wcs_calibrated_image.sh output for wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits (1st new image)
verification OK: wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits
Image size: 941.6'x626.7' 15.7(deg)x10.4(deg) 9576x6388 pix
Image scale: 5.90"/pix along the X axis and 5.89"/pix along the Y axis
Image center: 17:09:06.718 +62:02:57.22 J2000 4789.000 3195.000
###################################
###################################
# Check the image center offset between the reference and the first second-epoch image (pointing accuracy)
Reference image center 17:08:33.660 +61:59:46.08
Second-epoch image center 17:09:06.718 +62:02:57.22
Angular distance between the image centers 0.0836 deg.
Soft limit: 0.50 deg. Hard limit: 1.00 deg.
###################################
###################################
# fov_of_wcs_calibrated_image.sh output for wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits (2nd new image)
verification OK: wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits
Image size: 941.6'x626.7' 15.7(deg)x10.4(deg) 9576x6388 pix
Image scale: 5.90"/pix along the X axis and 5.89"/pix along the Y axis
Image center: 17:09:04.238 +62:03:29.07 J2000 4789.000 3195.000
###################################
###################################
# Check the image center offset between the reference and the second second-epoch image (pointing accuracy)
Reference image center 17:08:33.660 +61:59:46.08
Second-epoch image center 17:09:04.238 +62:03:29.07
Angular distance between the image centers 0.0861 deg.
###################################
###################################
# Check the image center offset between the first and the second second-epoch image (shift should be applied between the second-epoch images)
Second-epoch first image center 17:09:06.718 +62:02:57.22
Second-epoch second image center 17:09:04.238 +62:03:29.07
Angular distance between the image centers 0.01009 deg.
###################################
Running solve_plate_with_UCAC5...
Preparing for a parallel run
Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits &> /tmp/tmp.raWuyMT4d6
Parallel run for /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits
Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits &> /tmp/tmp.Ibk8Clbpkv
Parallel run for /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits
Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits &> /tmp/tmp.OVhCizSyFp
Parallel run for /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits
Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits &> /tmp/tmp.YjUZMIjnCp
Parallel run for /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits
Calibrating the magnitude scale
Found non-empty wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits
____ Start of magnitude calibration ____
PHOTOMETRIC_CALIBRATION=TYCHO2_V
Calibrating the magnitude scale with Tycho-2 stars
util/transients/transient_factory_test31.sh is checking for the presence of non-empty wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits and wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat
wait (drain background util/solve_plate_with_UCAC5 jobs before Tycho-2 calibration -- avoids wcs_.fits write race)
Tycho-2 catalog is found at lib/catalogs/tycho2
Tycho-2 catalog and the derived bright star exclusion list are ready
Checking for the presence of non-empty wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits and wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat
Found non-empty wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits and wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat
The reference image (wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits) and catalog (wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat) found
'wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat' -> 'wcsmag.cat'
Read 63702 stars from the SExtractor catalog wcsmag.cat
Detected star coordinate range: RA 237.9201 to 276.7125 deg, Dec +55.8395 to +67.2662 deg
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.00
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.01
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.02
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.03
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.04
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.05
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.06
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.07
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.08
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.09
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.10
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.11
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.12
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.13
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.14
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.15
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.16
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.17
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.18
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.19
Tycho-2 catalog search boundaries: RA 237.9201 to 276.7125 deg, Dec 55.8395 to 67.2662 deg
Loaded 9375 Tycho-2 stars within the image boundaries (VT and BT non-zero).
Relation between the catalog and instrumental magnitudes is written to calib.txt
Stars used for magnitude calibration (good matches): 5541 out of 6359 total matches.
Matched with Tycho-2 6359 out of 63702 detected stars.
The calibration function type and coefficients are written to calib.txt_param
util/calibrate_magnitude_scale 0.000000 1.000000 22.555600
a=0.000000 b=1.000000 c=22.555600
From vast_summary.log: estimated ref. image limiting mag.: -7.11
Updating vast_summary.log: Estimated ref. image limiting mag.: 15.45
Updated vast_limiting_magnitude.log with calibrated magnitudes
Working...
Please, PLEASE, be patient!!!
All lightcurves processed! =)
Estimated ref. image limiting mag.: 15.45
Lightcurve magnitude calibration plot:

Preparing per-reference-image forced-photometry calibration (method=tycho2 band=V)
Read 63702 stars from the SExtractor catalog wcsmag.cat
Detected star coordinate range: RA 237.9201 to 276.7125 deg, Dec +55.8395 to +67.2662 deg
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.00
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.01
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.02
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.03
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.04
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.05
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.06
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.07
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.08
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.09
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.10
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.11
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.12
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.13
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.14
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.15
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.16
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.17
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.18
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.19
Tycho-2 catalog search boundaries: RA 237.9201 to 276.7125 deg, Dec 55.8395 to 67.2662 deg
Loaded 9375 Tycho-2 stars within the image boundaries (VT and BT non-zero).
Relation between the catalog and instrumental magnitudes is written to calib.txt
Stars used for magnitude calibration (good matches): 5541 out of 6359 total matches.
Matched with Tycho-2 6359 out of 63702 detected stars.
util/calibrate_single_image_with_tycho2.sh: calibrated wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits via Tycho-2
Single-image forced-photometry magnitude calibration plot for wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits:

Forced-photometry filter: reusing the VaST-run aperture from image00001.cat.aperture for wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits
Forced-photometry filter: calibrated wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits -> calib.txt_param_ref_wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits (aperture=4.9)
Read 64271 stars from the SExtractor catalog wcsmag.cat
Detected star coordinate range: RA 237.9600 to 276.7126 deg, Dec +55.8529 to +67.2581 deg
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.00
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.01
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.02
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.03
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.04
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.05
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.06
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.07
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.08
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.09
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.10
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.11
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.12
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.13
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.14
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.15
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.16
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.17
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.18
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.19
Tycho-2 catalog search boundaries: RA 237.9600 to 276.7126 deg, Dec 55.8529 to 67.2581 deg
Loaded 9339 Tycho-2 stars within the image boundaries (VT and BT non-zero).
Relation between the catalog and instrumental magnitudes is written to calib.txt
Stars used for magnitude calibration (good matches): 5522 out of 6355 total matches.
Matched with Tycho-2 6355 out of 64271 detected stars.
util/calibrate_single_image_with_tycho2.sh: calibrated wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits via Tycho-2
Single-image forced-photometry magnitude calibration plot for wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits:

Forced-photometry filter: reusing the VaST-run aperture from image00002.cat.aperture for wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits
Forced-photometry filter: calibrated wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits -> calib.txt_param_ref_wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits (aperture=4.9)
____ End of magnitude calibration ____
Applying consolidated magnitude filters...
Preparing the exclusion lists for this field
Done with filtering
Found 68 candidate transients before the final filtering. (Hard limit: 10000)
Median FWHM seeing for isolated stars:
2.1 pix Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits
2.1 pix Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits
2.0 pix fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits
2.0 pix fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits
Limiting magnitude estimates:
15.4 mag. Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits
15.4 mag. Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits
14.5 mag. fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits
14.5 mag. fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits
All-image limiting magnitude estimate: 14.5 (SNR ) 13.9 (80% of stars) with default.sex.telephoto_lens_vSTL
The first estimate is the magnitude of a star detected with a signal-to-noise ratio of following Karpov (2025, Acta Polytechnica, 65, 50).
This value should be representative of the faintest stars clearly visible in the image.
The brighter of the limiting magnitude estimates for the two second-epoch images is reported here.
The second estimate is the 80th percentile of the magnitude distribution of stars detected on all four images.
This value is representative of the faintest object that may enter the candidate transients list.
The hard cut-off for the candidate transients is 15.5 mag.
Waiting for UCAC5 plate solver
wait
############ /tmp/tmp.raWuyMT4d6 (6) ############
Parsing command line arguments...
WARNING from replace_file_with_symlink_if_filename_contains_white_spaces() the input file /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits is already a symlink and we do not allow symlinks on symlinks
The guess is based on the existing WCS header.
Trying to blindly solve the plate (local solve-field or remote server)...
/data_ssd/NMW-TexasTech/workdir/vast_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits 571.0
Entering WCS image calibration mode.
ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits
FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits
WARNING from replace_file_with_symlink_if_filename_contains_white_spaces() the input file /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits is already a symlink and we do not allow symlinks on symlinks
FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits
verification OK: /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits
It's a known telescope with plate solutions that are supposed to be good.
The input image /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits has a WCS header - will blindly trust it is good...
'/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits' -> 'wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits'
This WCS solution (astrometrynet) will be kept as is, not refit by util/solve_plate_with_UCAC5
FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits
WCS_IMAGE_NAME=wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits
WCS-calibrated image found: wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits
Checking if the catalog wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat corresponding to the image wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits alredy exist and is non-empty...
Catalog wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat corresponding to the image wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits found.
The catalog is in the new format, as expected.
The plate-solved (WCS-calibrated) image is saved to wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits
util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits
WCS catalog name: wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat
Excluding image region: 190.0 1039.0 192.0 1041.0 (defined in bad_region.lst)
Excluding image region: 226.0 1548.0 228.0 1550.0 (defined in bad_region.lst)
Excluding image region: 351.0 1875.0 353.0 1877.0 (defined in bad_region.lst)
Excluding image region: 501.0 5912.0 503.0 5914.0 (defined in bad_region.lst)
Excluding image region: 638.0 5545.0 640.0 5547.0 (defined in bad_region.lst)
Excluding image region: 724.0 2731.0 726.0 2733.0 (defined in bad_region.lst)
Excluding image region: 883.0 1376.0 885.0 1378.0 (defined in bad_region.lst)
Excluding image region: 901.0 3972.0 903.0 3974.0 (defined in bad_region.lst)
Excluding image region: 1151.0 918.0 1153.0 920.0 (defined in bad_region.lst)
Excluding image region: 1157.0 135.0 1159.0 137.0 (defined in bad_region.lst)
Excluding more image regions!.. (will not print them all)
Excluded a total of 50 image regions (defined in bad_region.lst).
SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=37, blended=3836, bad_region=1, passed=63665
Got 63665 stars (including 59741 good ones) from the SExtractor catalog wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat
util/solve_plate_with_UCAC5 got 63665 stars from the SExtractor catalog
Updated FoV from the plate-solved image: 937.4'
Seting catalog search parameters based on the expected field of view 937.4 arcmin
UCAC5 catalog search parameters:
catalog_search_parameters->search_radius_deg= 0.013019 (46.9 arcsec)
catalog_search_parameters->brightest_mag= 1.00
catalog_search_parameters->faintest_mag= 13.50
catalog_search_parameters->search_radius_second_step_deg 0.010416 (37.5 arcsec)
ITERATION 01 -- talking to VizieR, this might be slow!
UCAC5 search strategy: trying local copy first
Found a local copy of UCAC5
UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50
Reading UCAC5 zone files...
Searching UCAC5 zones 729 to 788 (Dec 55.8 to 67.3)
Done reading UCAC5 zone files...
Matched 4907 stars with the local copy of UCAC5.
The local UCAC5 search seems to be a success
Correcting the measured astrometric positions...
Accuracy estimation diagnostic: 4903 matched stars entering correct_measured_positions(), 4903 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.37"
Removing outliers...
Correcting the measured astrometric positions...
Accuracy estimation diagnostic: 4903 matched stars entering correct_measured_positions(), 63665 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.37"
ITERATION 02 -- talking to VizieR, this might be slow!
UCAC5 search strategy: trying local copy first
Found a local copy of UCAC5
UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50
Reading UCAC5 zone files...
Searching UCAC5 zones 729 to 788 (Dec 55.8 to 67.3)
Done reading UCAC5 zone files...
Matched 4907 stars with the local copy of UCAC5.
The local UCAC5 search seems to be a success
Accuracy estimation diagnostic: 4903 matched stars entering correct_measured_positions(), 63665 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.37"
Accuracy estimation diagnostic: 4903 matched stars entering correct_measured_positions(), 63665 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.39"
Excluding outliers - 4903 stars left (next iteration limit 5393)
Stop iterations.
The field is successfully solved and matched with the astrometric catalog! :)
SIP_REFIT: wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits is a symbolic link - will not rewrite the WCS of whatever it points to, but will still refit the output catalog positions
SIP_REFIT: util/identify.sh trusts the WCS of wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits (astrometrynet) - keeping it, no refit (set VAST_FORCE_SIP_REFIT=1 to refit anyway)
WCS_QUALITY_DIAG: file=Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits N_match=4903 sigma_overall_arcsec=0.416 sigma_q1_arcsec=0.359 sigma_q2_arcsec=0.451 sigma_q3_arcsec=0.483 sigma_q4_arcsec=0.395 n_q1=1358 n_q2=1206 n_q3=1167 n_q4=1172 worst_quadrant_to_overall_ratio=1.160
The image catalog is written to wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat.ucac5
The DS9 region file with the matched stars is written to wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat.ds9.reg
You may view it with the command:
ds9 /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits -region wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat.ds9.reg
The astrometric residuals vector field is written to wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat.astrometric_residuals
Option '-n' not using photometric catalogs, just stick with astrometry
opt '-i': 2 is the maximum number of iterations
FORCED_PHOTOMETRY_CALIBRATION_METHOD=tycho2 - not using remote photometric catalogs, just stick with astrometry
############ /tmp/tmp.Ibk8Clbpkv (6) ############
Parsing command line arguments...
WARNING from replace_file_with_symlink_if_filename_contains_white_spaces() the input file /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits is already a symlink and we do not allow symlinks on symlinks
The guess is based on the existing WCS header.
Trying to blindly solve the plate (local solve-field or remote server)...
/data_ssd/NMW-TexasTech/workdir/vast_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits 571.0
Entering WCS image calibration mode.
ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits
FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits
WARNING from replace_file_with_symlink_if_filename_contains_white_spaces() the input file /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits is already a symlink and we do not allow symlinks on symlinks
FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits
verification OK: /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits
It's a known telescope with plate solutions that are supposed to be good.
The input image /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits has a WCS header - will blindly trust it is good...
'/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits' -> 'wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits'
This WCS solution (astrometrynet) will be kept as is, not refit by util/solve_plate_with_UCAC5
FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits
WCS_IMAGE_NAME=wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits
WCS-calibrated image found: wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits
Checking if the catalog wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits.wcscat corresponding to the image wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits alredy exist and is non-empty...
Catalog wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits.wcscat corresponding to the image wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits found.
The catalog is in the new format, as expected.
The plate-solved (WCS-calibrated) image is saved to wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits
util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits
WCS catalog name: wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits.wcscat
Excluding image region: 190.0 1039.0 192.0 1041.0 (defined in bad_region.lst)
Excluding image region: 226.0 1548.0 228.0 1550.0 (defined in bad_region.lst)
Excluding image region: 351.0 1875.0 353.0 1877.0 (defined in bad_region.lst)
Excluding image region: 501.0 5912.0 503.0 5914.0 (defined in bad_region.lst)
Excluding image region: 638.0 5545.0 640.0 5547.0 (defined in bad_region.lst)
Excluding image region: 724.0 2731.0 726.0 2733.0 (defined in bad_region.lst)
Excluding image region: 883.0 1376.0 885.0 1378.0 (defined in bad_region.lst)
Excluding image region: 901.0 3972.0 903.0 3974.0 (defined in bad_region.lst)
Excluding image region: 1151.0 918.0 1153.0 920.0 (defined in bad_region.lst)
Excluding image region: 1157.0 135.0 1159.0 137.0 (defined in bad_region.lst)
Excluding more image regions!.. (will not print them all)
Excluded a total of 50 image regions (defined in bad_region.lst).
SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=43, blended=3885, bad_region=0, passed=64228
Got 64228 stars (including 60263 good ones) from the SExtractor catalog wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits.wcscat
util/solve_plate_with_UCAC5 got 64228 stars from the SExtractor catalog
Updated FoV from the plate-solved image: 937.3'
Seting catalog search parameters based on the expected field of view 937.3 arcmin
UCAC5 catalog search parameters:
catalog_search_parameters->search_radius_deg= 0.013018 (46.9 arcsec)
catalog_search_parameters->brightest_mag= 1.00
catalog_search_parameters->faintest_mag= 13.50
catalog_search_parameters->search_radius_second_step_deg 0.010414 (37.5 arcsec)
ITERATION 01 -- talking to VizieR, this might be slow!
UCAC5 search strategy: trying local copy first
Found a local copy of UCAC5
UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50
Reading UCAC5 zone files...
Searching UCAC5 zones 729 to 788 (Dec 55.9 to 67.3)
Done reading UCAC5 zone files...
Matched 4906 stars with the local copy of UCAC5.
The local UCAC5 search seems to be a success
Correcting the measured astrometric positions...
Accuracy estimation diagnostic: 4903 matched stars entering correct_measured_positions(), 4903 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.35"
Removing outliers...
Correcting the measured astrometric positions...
Accuracy estimation diagnostic: 4903 matched stars entering correct_measured_positions(), 64228 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.35"
ITERATION 02 -- talking to VizieR, this might be slow!
UCAC5 search strategy: trying local copy first
Found a local copy of UCAC5
UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50
Reading UCAC5 zone files...
Searching UCAC5 zones 729 to 788 (Dec 55.9 to 67.3)
Done reading UCAC5 zone files...
Matched 4906 stars with the local copy of UCAC5.
The local UCAC5 search seems to be a success
Accuracy estimation diagnostic: 4903 matched stars entering correct_measured_positions(), 64228 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.35"
Accuracy estimation diagnostic: 4903 matched stars entering correct_measured_positions(), 64228 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.37"
Excluding outliers - 4903 stars left (next iteration limit 5393)
Stop iterations.
The field is successfully solved and matched with the astrometric catalog! :)
SIP_REFIT: wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits is a symbolic link - will not rewrite the WCS of whatever it points to, but will still refit the output catalog positions
SIP_REFIT: util/identify.sh trusts the WCS of wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits (astrometrynet) - keeping it, no refit (set VAST_FORCE_SIP_REFIT=1 to refit anyway)
WCS_QUALITY_DIAG: file=Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits N_match=4903 sigma_overall_arcsec=0.391 sigma_q1_arcsec=0.338 sigma_q2_arcsec=0.424 sigma_q3_arcsec=0.476 sigma_q4_arcsec=0.359 n_q1=1359 n_q2=1221 n_q3=1158 n_q4=1165 worst_quadrant_to_overall_ratio=1.216
The image catalog is written to wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits.wcscat.ucac5
The DS9 region file with the matched stars is written to wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits.wcscat.ds9.reg
You may view it with the command:
ds9 /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits -region wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits.wcscat.ds9.reg
The astrometric residuals vector field is written to wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits.wcscat.astrometric_residuals
Option '-n' not using photometric catalogs, just stick with astrometry
opt '-i': 2 is the maximum number of iterations
FORCED_PHOTOMETRY_CALIBRATION_METHOD=tycho2 - not using remote photometric catalogs, just stick with astrometry
############ /tmp/tmp.OVhCizSyFp (6) ############
Parsing command line arguments...
The minor axis of the CCD chip should be 24.0 mm based on the derived pixel size of 3.8 um
Internal estimated FoV 605.3'
The guess is based on the FOCALLEN keyword.
Trying to blindly solve the plate (local solve-field or remote server)...
/data_ssd/NMW-TexasTech/workdir/vast_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits 605.0
Entering WCS image calibration mode.
ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits
FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits
FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits
verification OK: /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits
It's not one of the telescopes that are know to produce images with good WCS solutions - will try to re-solve!
FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits
WCS_IMAGE_NAME=wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits
WCS-calibrated image found: wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits
Checking if the catalog wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits.wcscat corresponding to the image wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits alredy exist and is non-empty...
Catalog wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits.wcscat corresponding to the image wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits found.
The catalog is in the new format, as expected.
The plate-solved (WCS-calibrated) image is saved to wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits
util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits
WCS catalog name: wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits.wcscat
Excluding image region: 190.0 1039.0 192.0 1041.0 (defined in bad_region.lst)
Excluding image region: 226.0 1548.0 228.0 1550.0 (defined in bad_region.lst)
Excluding image region: 351.0 1875.0 353.0 1877.0 (defined in bad_region.lst)
Excluding image region: 501.0 5912.0 503.0 5914.0 (defined in bad_region.lst)
Excluding image region: 638.0 5545.0 640.0 5547.0 (defined in bad_region.lst)
Excluding image region: 724.0 2731.0 726.0 2733.0 (defined in bad_region.lst)
Excluding image region: 883.0 1376.0 885.0 1378.0 (defined in bad_region.lst)
Excluding image region: 901.0 3972.0 903.0 3974.0 (defined in bad_region.lst)
Excluding image region: 1151.0 918.0 1153.0 920.0 (defined in bad_region.lst)
Excluding image region: 1157.0 135.0 1159.0 137.0 (defined in bad_region.lst)
Excluding more image regions!.. (will not print them all)
Excluded a total of 50 image regions (defined in bad_region.lst).
SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=11, blended=1225, bad_region=3, passed=35984
Got 35984 stars (including 34691 good ones) from the SExtractor catalog wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits.wcscat
util/solve_plate_with_UCAC5 got 35984 stars from the SExtractor catalog
Updated FoV from the plate-solved image: 941.6'
Seting catalog search parameters based on the expected field of view 941.6 arcmin
UCAC5 catalog search parameters:
catalog_search_parameters->search_radius_deg= 0.013078 (47.1 arcsec)
catalog_search_parameters->brightest_mag= 1.00
catalog_search_parameters->faintest_mag= 13.50
catalog_search_parameters->search_radius_second_step_deg 0.010462 (37.7 arcsec)
ITERATION 01 -- talking to VizieR, this might be slow!
UCAC5 search strategy: trying local copy first
Found a local copy of UCAC5
UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50
Reading UCAC5 zone files...
Searching UCAC5 zones 727 to 788 (Dec 55.5 to 67.4)
Done reading UCAC5 zone files...
Matched 4904 stars with the local copy of UCAC5.
The local UCAC5 search seems to be a success
Correcting the measured astrometric positions...
Accuracy estimation diagnostic: 4895 matched stars entering correct_measured_positions(), 4895 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.27"
Removing outliers...
Correcting the measured astrometric positions...
Accuracy estimation diagnostic: 4895 matched stars entering correct_measured_positions(), 35984 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.27"
ITERATION 02 -- talking to VizieR, this might be slow!
UCAC5 search strategy: trying local copy first
Found a local copy of UCAC5
UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50
Reading UCAC5 zone files...
Searching UCAC5 zones 727 to 788 (Dec 55.5 to 67.4)
Done reading UCAC5 zone files...
Matched 4903 stars with the local copy of UCAC5.
The local UCAC5 search seems to be a success
Accuracy estimation diagnostic: 4894 matched stars entering correct_measured_positions(), 35984 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.27"
Accuracy estimation diagnostic: 4894 matched stars entering correct_measured_positions(), 35984 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.27"
Excluding outliers - 4894 stars left (next iteration limit 5384)
Stop iterations.
The field is successfully solved and matched with the astrometric catalog! :)
SIP_REFIT: wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits is a symbolic link - will not rewrite the WCS of whatever it points to, but will still refit the output catalog positions
SIP_REFIT: SIP order 2 trial: matched=4894 robust_rms=9.353 arcsec worst_quadrant_rms=15.440 arcsec
SIP_REFIT: SIP order 3 trial: matched=4894 robust_rms=0.459 arcsec worst_quadrant_rms=0.494 arcsec
SIP_REFIT: SIP order 5 trial: matched=4894 robust_rms=0.288 arcsec worst_quadrant_rms=0.316 arcsec
SIP_REFIT: selected SIP order 5
SIP_REFIT: order=5 matched=4894 robust_rms_before=0.711 arcsec robust_rms_before_corrected=0.283 arcsec robust_rms_after=0.288 arcsec worst_quadrant_rms_before=0.304 worst_quadrant_rms_after=0.316
SIP_REFIT: refit does not sufficiently improve on the solution it would replace (best worst-quadrant baseline 0.304 arcsec) - keeping the original
WCS_QUALITY_DIAG: file=fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits N_match=4894 sigma_overall_arcsec=0.287 sigma_q1_arcsec=0.291 sigma_q2_arcsec=0.308 sigma_q3_arcsec=0.290 sigma_q4_arcsec=0.258 n_q1=1450 n_q2=1076 n_q3=1303 n_q4=1065 worst_quadrant_to_overall_ratio=1.073
The image catalog is written to wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits.wcscat.ucac5
The DS9 region file with the matched stars is written to wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits.wcscat.ds9.reg
You may view it with the command:
ds9 /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits -region wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits.wcscat.ds9.reg
The astrometric residuals vector field is written to wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits.wcscat.astrometric_residuals
Option '-n' not using photometric catalogs, just stick with astrometry
opt '-i': 2 is the maximum number of iterations
FORCED_PHOTOMETRY_CALIBRATION_METHOD=tycho2 - not using remote photometric catalogs, just stick with astrometry
############ /tmp/tmp.YjUZMIjnCp (6) ############
Parsing command line arguments...
The minor axis of the CCD chip should be 24.0 mm based on the derived pixel size of 3.8 um
Internal estimated FoV 605.3'
The guess is based on the FOCALLEN keyword.
Trying to blindly solve the plate (local solve-field or remote server)...
/data_ssd/NMW-TexasTech/workdir/vast_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits 605.0
Entering WCS image calibration mode.
ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits
FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits
FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits
verification OK: /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits
It's not one of the telescopes that are know to produce images with good WCS solutions - will try to re-solve!
FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits
WCS_IMAGE_NAME=wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits
WCS-calibrated image found: wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits
Checking if the catalog wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits.wcscat corresponding to the image wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits alredy exist and is non-empty...
Catalog wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits.wcscat corresponding to the image wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits found.
The catalog is in the new format, as expected.
The plate-solved (WCS-calibrated) image is saved to wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits
util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits
WCS catalog name: wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits.wcscat
Excluding image region: 190.0 1039.0 192.0 1041.0 (defined in bad_region.lst)
Excluding image region: 226.0 1548.0 228.0 1550.0 (defined in bad_region.lst)
Excluding image region: 351.0 1875.0 353.0 1877.0 (defined in bad_region.lst)
Excluding image region: 501.0 5912.0 503.0 5914.0 (defined in bad_region.lst)
Excluding image region: 638.0 5545.0 640.0 5547.0 (defined in bad_region.lst)
Excluding image region: 724.0 2731.0 726.0 2733.0 (defined in bad_region.lst)
Excluding image region: 883.0 1376.0 885.0 1378.0 (defined in bad_region.lst)
Excluding image region: 901.0 3972.0 903.0 3974.0 (defined in bad_region.lst)
Excluding image region: 1151.0 918.0 1153.0 920.0 (defined in bad_region.lst)
Excluding image region: 1157.0 135.0 1159.0 137.0 (defined in bad_region.lst)
Excluding more image regions!.. (will not print them all)
Excluded a total of 50 image regions (defined in bad_region.lst).
SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=7, blended=1235, bad_region=3, passed=35975
Got 35975 stars (including 34677 good ones) from the SExtractor catalog wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits.wcscat
util/solve_plate_with_UCAC5 got 35975 stars from the SExtractor catalog
Updated FoV from the plate-solved image: 941.6'
Seting catalog search parameters based on the expected field of view 941.6 arcmin
UCAC5 catalog search parameters:
catalog_search_parameters->search_radius_deg= 0.013078 (47.1 arcsec)
catalog_search_parameters->brightest_mag= 1.00
catalog_search_parameters->faintest_mag= 13.50
catalog_search_parameters->search_radius_second_step_deg 0.010462 (37.7 arcsec)
ITERATION 01 -- talking to VizieR, this might be slow!
UCAC5 search strategy: trying local copy first
Found a local copy of UCAC5
UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50
Reading UCAC5 zone files...
Searching UCAC5 zones 727 to 789 (Dec 55.6 to 67.4)
Done reading UCAC5 zone files...
Matched 4907 stars with the local copy of UCAC5.
The local UCAC5 search seems to be a success
Correcting the measured astrometric positions...
Accuracy estimation diagnostic: 4899 matched stars entering correct_measured_positions(), 4899 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.27"
Removing outliers...
Correcting the measured astrometric positions...
Accuracy estimation diagnostic: 4899 matched stars entering correct_measured_positions(), 35975 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.27"
ITERATION 02 -- talking to VizieR, this might be slow!
UCAC5 search strategy: trying local copy first
Found a local copy of UCAC5
UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50
Reading UCAC5 zone files...
Searching UCAC5 zones 727 to 789 (Dec 55.6 to 67.4)
Done reading UCAC5 zone files...
Matched 4907 stars with the local copy of UCAC5.
The local UCAC5 search seems to be a success
Accuracy estimation diagnostic: 4899 matched stars entering correct_measured_positions(), 35975 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.27"
Accuracy estimation diagnostic: 4899 matched stars entering correct_measured_positions(), 35975 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.27"
Excluding outliers - 4899 stars left (next iteration limit 5388)
Stop iterations.
The field is successfully solved and matched with the astrometric catalog! :)
SIP_REFIT: wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits is a symbolic link - will not rewrite the WCS of whatever it points to, but will still refit the output catalog positions
SIP_REFIT: SIP order 2 trial: matched=4899 robust_rms=9.551 arcsec worst_quadrant_rms=14.762 arcsec
SIP_REFIT: SIP order 3 trial: matched=4899 robust_rms=0.462 arcsec worst_quadrant_rms=0.509 arcsec
SIP_REFIT: SIP order 5 trial: matched=4899 robust_rms=0.290 arcsec worst_quadrant_rms=0.307 arcsec
SIP_REFIT: selected SIP order 5
SIP_REFIT: order=5 matched=4899 robust_rms_before=0.686 arcsec robust_rms_before_corrected=0.284 arcsec robust_rms_after=0.290 arcsec worst_quadrant_rms_before=0.307 worst_quadrant_rms_after=0.307
SIP_REFIT: refit does not sufficiently improve on the solution it would replace (best worst-quadrant baseline 0.307 arcsec) - keeping the original
WCS_QUALITY_DIAG: file=fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits N_match=4899 sigma_overall_arcsec=0.287 sigma_q1_arcsec=0.290 sigma_q2_arcsec=0.307 sigma_q3_arcsec=0.290 sigma_q4_arcsec=0.265 n_q1=1445 n_q2=1075 n_q3=1303 n_q4=1076 worst_quadrant_to_overall_ratio=1.071
The image catalog is written to wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits.wcscat.ucac5
The DS9 region file with the matched stars is written to wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits.wcscat.ds9.reg
You may view it with the command:
ds9 /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits -region wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits.wcscat.ds9.reg
The astrometric residuals vector field is written to wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits.wcscat.astrometric_residuals
Option '-n' not using photometric catalogs, just stick with astrometry
opt '-i': 2 is the maximum number of iterations
FORCED_PHOTOMETRY_CALIBRATION_METHOD=tycho2 - not using remote photometric catalogs, just stick with astrometry
Skipping WCS quality comparison: not the first SExtractor pass (default.sex.telephoto_lens_vSTL)
Copying WCS-calibrated images back to input directory
Saving fully-calibrated image wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits
INFO: FPACK_FULLY_CALIBRATED_IMAGE=no (not compressing the image)
The destination file is already there - not rewriting /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits
Saving fully-calibrated image wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits
INFO: FPACK_FULLY_CALIBRATED_IMAGE=no (not compressing the image)
The destination file is already there - not rewriting /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits
Preparing the HTML report for the field Dra-07-Q1b1x1 with default.sex.telephoto_lens_vSTL
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:46:15.32 +61:20:17.0: 13.62 +/- 0.04 detection
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:32:48.43 +65:31:09.3: 13.60 +/- 0.04 detection
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 16:05:49.96 +64:55:46.0: 13.15 +/- 0.03 detection
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:51:53.29 +62:07:27.3: 13.32 +/- 0.03 detection
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 16:04:37.94 +61:09:47.1: 12.72 +/- 0.02 detection
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:17:11.85 +64:44:44.4: 14.13 +/- 0.06 detection
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 18:07:44.77 +62:33:37.4: 14.08 +/- 0.07 detection
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 16:10:20.44 +65:10:28.3: 12.66 +/- 0.02 detection
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:05:18.23 +66:17:32.6: 12.53 +/- 0.01 detection
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:32:48.43 +65:31:09.3: 13.58 +/- 0.04 detection
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:17:11.85 +64:44:44.4: 14.10 +/- 0.06 detection
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 16:04:37.94 +61:09:47.1: 12.71 +/- 0.02 detection
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 16:05:49.96 +64:55:46.0: 13.20 +/- 0.03 detection
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:46:15.32 +61:20:17.0: 13.62 +/- 0.04 detection
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:51:53.29 +62:07:27.3: 13.39 +/- 0.03 detection
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 18:07:44.77 +62:33:37.4: 14.02 +/- 0.06 detection
Forced photometry reference-image weighted average: 13.59 +/- 0.03
Forced photometry reference-image weighted average: 14.11 +/- 0.04
Forced photometry reference-image weighted average: 12.71 +/- 0.02
Forced photometry reference-image weighted average: 13.17 +/- 0.02
Forced photometry filter REJECTED candidate at 17:32:48.43 +65:31:09.3: ref_mag=13.59 +/- 0.03 new_mean_mag=13.9467 delta=-0.36 (need > 0.90)
Forced photometry reference-image weighted average: 13.62 +/- 0.03
Forced photometry reference-image weighted average: 13.35 +/- 0.02
Forced photometry filter REJECTED candidate at 17:17:11.85 +64:44:44.4: ref_mag=14.11 +/- 0.04 new_mean_mag=14.1916 delta=-0.08 (need > 0.90)
Forced photometry filter REJECTED candidate at 16:04:37.94 +61:09:47.1: ref_mag=12.71 +/- 0.02 new_mean_mag=12.9606 delta=-0.25 (need > 0.90)
Forced photometry filter REJECTED candidate at 16:05:49.96 +64:55:46.0: ref_mag=13.17 +/- 0.02 new_mean_mag=13.1484 delta=0.02 (need > 0.90)
Forced photometry filter REJECTED candidate at 17:46:15.32 +61:20:17.0: ref_mag=13.62 +/- 0.03 new_mean_mag=13.8486 delta=-0.23 (need > 0.90)
Forced photometry filter REJECTED candidate at 17:51:53.29 +62:07:27.3: ref_mag=13.35 +/- 0.02 new_mean_mag=13.4814 delta=-0.13 (need > 0.90)
Forced photometry reference-image weighted average: 14.05 +/- 0.05
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:22:49.68 +63:25:10.9: 12.31 +/- 0.01 detection
Forced photometry filter REJECTED candidate at 18:07:44.77 +62:33:37.4: ref_mag=14.05 +/- 0.05 new_mean_mag=14.0485 delta=0.00 (need > 0.90)
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 16:10:20.44 +65:10:28.3: 12.71 +/- 0.02 detection
Forced photometry reference-image weighted average: 12.69 +/- 0.01
Forced photometry filter REJECTED candidate at 16:10:20.44 +65:10:28.3: ref_mag=12.69 +/- 0.01 new_mean_mag=12.8781 delta=-0.19 (need > 0.90)
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:05:18.23 +66:17:32.6: 12.49 +/- 0.01 detection
Forced photometry reference-image weighted average: 12.51 +/- 0.01
Forced photometry filter REJECTED candidate at 17:05:18.23 +66:17:32.6: ref_mag=12.51 +/- 0.01 new_mean_mag=12.8197 delta=-0.31 (need > 0.90)
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:22:49.68 +63:25:10.9: 12.27 +/- 0.01 detection
Forced photometry reference-image weighted average: 12.29 +/- 0.01
Forced photometry filter REJECTED candidate at 17:22:49.68 +63:25:10.9: ref_mag=12.29 +/- 0.01 new_mean_mag=12.7724 delta=-0.49 (need > 0.90)
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 16:08:19.29 +58:32:53.4: 11.53 +/- 0.01 detection
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 18:03:26.28 +56:56:13.4: 11.55 +/- 0.01 detection
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:17:25.64 +57:24:52.3: 12.54 +/- 0.01 detection
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 18:03:26.28 +56:56:13.4: 11.52 +/- 0.01 detection
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 16:08:19.29 +58:32:53.4: 11.53 +/- 0.01 detection
Forced photometry reference-image weighted average: 11.54 +/- 0.01
Forced photometry filter REJECTED candidate at 18:03:26.28 +56:56:13.4: ref_mag=11.54 +/- 0.01 new_mean_mag=11.7867 delta=-0.25 (need > 0.90)
Forced photometry reference-image weighted average: 11.53 +/- 0.01
Forced photometry filter REJECTED candidate at 16:08:19.29 +58:32:53.4: ref_mag=11.53 +/- 0.01 new_mean_mag=11.6619 delta=-0.13 (need > 0.90)
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:43:09.24 +60:46:55.9: 12.95 +/- 0.02 detection
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:55:59.41 +62:32:44.7: 13.11 +/- 0.03 detection
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:59:31.29 +61:37:05.7: 12.97 +/- 0.02 detection
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:17:25.64 +57:24:52.3: 12.56 +/- 0.02 detection
Forced photometry reference-image weighted average: 12.55 +/- 0.01
Forced photometry filter REJECTED candidate at 17:17:25.64 +57:24:52.3: ref_mag=12.55 +/- 0.01 new_mean_mag=12.6394 delta=-0.09 (need > 0.90)
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:42:46.05 +58:40:03.5: 13.37 +/- 0.04 detection
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:32:55.19 +59:48:12.5: 13.29 +/- 0.04 detection
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:44:52.35 +60:19:56.1: 13.39 +/- 0.04 detection
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:05:33.03 +58:43:08.3: 13.31 +/- 0.03 detection
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:43:09.24 +60:46:55.9: 12.93 +/- 0.02 detection
Forced photometry reference-image weighted average: 12.94 +/- 0.01
Forced photometry filter REJECTED candidate at 17:43:09.24 +60:46:55.9: ref_mag=12.94 +/- 0.01 new_mean_mag=13.0700 delta=-0.13 (need > 0.90)
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:55:59.41 +62:32:44.7: 13.18 +/- 0.03 detection
Forced photometry reference-image weighted average: 13.14 +/- 0.02
Forced photometry filter REJECTED candidate at 17:55:59.41 +62:32:44.7: ref_mag=13.14 +/- 0.02 new_mean_mag=13.1572 delta=-0.01 (need > 0.90)
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:59:31.29 +61:37:05.7: 12.90 +/- 0.02 detection
Forced photometry reference-image weighted average: 12.93 +/- 0.02
Forced photometry filter REJECTED candidate at 17:59:31.29 +61:37:05.7: ref_mag=12.93 +/- 0.02 new_mean_mag=13.1025 delta=-0.17 (need > 0.90)
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 18:00:05.64 +60:26:51.0: 13.69 +/- 0.05 detection
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:42:46.05 +58:40:03.5: 13.35 +/- 0.03 detection
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:32:55.19 +59:48:12.5: 13.25 +/- 0.03 detection
Forced photometry reference-image weighted average: 13.36 +/- 0.03
Forced photometry filter REJECTED candidate at 17:42:46.05 +58:40:03.5: ref_mag=13.36 +/- 0.03 new_mean_mag=13.3255 delta=0.03 (need > 0.90)
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:44:52.35 +60:19:56.1: 13.36 +/- 0.03 detection
Forced photometry reference-image weighted average: 13.27 +/- 0.02
Forced photometry filter REJECTED candidate at 17:32:55.19 +59:48:12.5: ref_mag=13.27 +/- 0.02 new_mean_mag=13.4000 delta=-0.13 (need > 0.90)
Forced photometry reference-image weighted average: 13.37 +/- 0.03
Forced photometry filter REJECTED candidate at 17:44:52.35 +60:19:56.1: ref_mag=13.37 +/- 0.03 new_mean_mag=13.4156 delta=-0.04 (need > 0.90)
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:05:33.03 +58:43:08.3: 13.27 +/- 0.03 detection
Forced photometry reference-image weighted average: 13.29 +/- 0.02
Forced photometry filter REJECTED candidate at 17:05:33.03 +58:43:08.3: ref_mag=13.29 +/- 0.02 new_mean_mag=13.3834 delta=-0.10 (need > 0.90)
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 18:00:05.64 +60:26:51.0: 13.78 +/- 0.05 detection
Forced photometry reference-image weighted average: 13.73 +/- 0.04
Forced photometry filter REJECTED candidate at 18:00:05.64 +60:26:51.0: ref_mag=13.73 +/- 0.04 new_mean_mag=13.6319 delta=0.10 (need > 0.90)
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:46:47.32 +59:14:47.9: 13.27 +/- 0.03 detection
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:35:41.31 +61:41:08.7: 13.45 +/- 0.04 detection
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 18:09:12.41 +59:45:29.4: 13.68 +/- 0.05 detection
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:08:13.22 +61:23:04.1: 13.34 +/- 0.03 detection
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 18:02:35.60 +60:34:37.6: 13.28 +/- 0.03 detection
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:28:21.13 +59:12:43.3: 13.50 +/- 0.04 detection
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 18:00:13.87 +56:35:31.2: 13.76 +/- 0.07 detection
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:46:47.32 +59:14:47.9: 13.34 +/- 0.04 detection
Forced photometry reference-image weighted average: 13.30 +/- 0.02
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:35:41.31 +61:41:08.7: 13.42 +/- 0.04 detection
Forced photometry filter REJECTED candidate at 17:46:47.32 +59:14:47.9: ref_mag=13.30 +/- 0.02 new_mean_mag=13.5619 delta=-0.26 (need > 0.90)
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:08:13.22 +61:23:04.1: 13.37 +/- 0.03 detection
Forced photometry reference-image weighted average: 13.43 +/- 0.03
Forced photometry filter REJECTED candidate at 17:35:41.31 +61:41:08.7: ref_mag=13.43 +/- 0.03 new_mean_mag=13.4762 delta=-0.04 (need > 0.90)
Forced photometry reference-image weighted average: 13.35 +/- 0.02
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 18:09:12.41 +59:45:29.4: 13.65 +/- 0.05 detection
Forced photometry filter REJECTED candidate at 17:08:13.22 +61:23:04.1: ref_mag=13.35 +/- 0.02 new_mean_mag=13.4625 delta=-0.11 (need > 0.90)
Forced photometry reference-image weighted average: 13.66 +/- 0.04
Forced photometry filter REJECTED candidate at 18:09:12.41 +59:45:29.4: ref_mag=13.66 +/- 0.04 new_mean_mag=13.7417 delta=-0.08 (need > 0.90)
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:08:50.61 +58:05:24.6: 13.52 +/- 0.04 detection
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 18:02:35.60 +60:34:37.6: 13.33 +/- 0.03 detection
Forced photometry reference-image weighted average: 13.31 +/- 0.02
Forced photometry filter REJECTED candidate at 18:02:35.60 +60:34:37.6: ref_mag=13.31 +/- 0.02 new_mean_mag=13.6497 delta=-0.34 (need > 0.90)
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:28:21.13 +59:12:43.3: 13.49 +/- 0.03 detection
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:47:00.16 +59:16:46.0: 13.68 +/- 0.05 detection
Forced photometry reference-image weighted average: 13.50 +/- 0.02
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 18:00:13.87 +56:35:31.2: 13.66 +/- 0.06 detection
Forced photometry filter REJECTED candidate at 17:28:21.13 +59:12:43.3: ref_mag=13.50 +/- 0.02 new_mean_mag=13.6048 delta=-0.11 (need > 0.90)
Forced photometry reference-image weighted average: 13.71 +/- 0.04
Forced photometry filter REJECTED candidate at 18:00:13.87 +56:35:31.2: ref_mag=13.71 +/- 0.04 new_mean_mag=13.7157 delta=-0.01 (need > 0.90)
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:42:33.66 +62:37:26.7: 13.68 +/- 0.04 detection
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:08:50.61 +58:05:24.6: 13.52 +/- 0.04 detection
Forced photometry reference-image weighted average: 13.52 +/- 0.03
Forced photometry filter REJECTED candidate at 17:08:50.61 +58:05:24.6: ref_mag=13.52 +/- 0.03 new_mean_mag=13.6327 delta=-0.11 (need > 0.90)
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:47:00.16 +59:16:46.0: 13.74 +/- 0.05 detection
Forced photometry reference-image weighted average: 13.71 +/- 0.04
Forced photometry filter REJECTED candidate at 17:47:00.16 +59:16:46.0: ref_mag=13.71 +/- 0.04 new_mean_mag=13.8542 delta=-0.14 (need > 0.90)
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:26:19.86 +61:24:57.4: 13.97 +/- 0.05 detection
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:51:46.05 +64:56:32.1: 13.62 +/- 0.04 detection
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:42:33.66 +62:37:26.7: 13.70 +/- 0.04 detection
Forced photometry reference-image weighted average: 13.69 +/- 0.03
Forced photometry filter REJECTED candidate at 17:42:33.66 +62:37:26.7: ref_mag=13.69 +/- 0.03 new_mean_mag=13.8812 delta=-0.19 (need > 0.90)
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:28:27.21 +59:02:56.2: 14.18 +/- 0.07 detection
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:36:41.82 +59:42:15.8: 14.36 +/- 0.08 detection
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 16:30:15.62 +67:01:54.8: 99.00 +/- 99.00 edge
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:31:22.12 +64:13:43.8: 14.06 +/- 0.06 detection
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:06:15.62 +63:33:31.3: 13.96 +/- 0.05 detection
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:26:19.86 +61:24:57.4: 14.04 +/- 0.06 detection
Forced photometry reference-image weighted average: 14.00 +/- 0.04
Forced photometry filter REJECTED candidate at 17:26:19.86 +61:24:57.4: ref_mag=14.00 +/- 0.04 new_mean_mag=13.9100 delta=0.09 (need > 0.90)
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:51:46.05 +64:56:32.1: 13.69 +/- 0.05 detection
Forced photometry reference-image weighted average: 13.65 +/- 0.03
Forced photometry filter REJECTED candidate at 17:51:46.05 +64:56:32.1: ref_mag=13.65 +/- 0.03 new_mean_mag=13.9797 delta=-0.33 (need > 0.90)
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:28:27.21 +59:02:56.2: 14.12 +/- 0.07 detection
Forced photometry reference-image weighted average: 14.15 +/- 0.05
Forced photometry filter REJECTED candidate at 17:28:27.21 +59:02:56.2: ref_mag=14.15 +/- 0.05 new_mean_mag=14.2189 delta=-0.07 (need > 0.90)
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:36:41.82 +59:42:15.8: 14.39 +/- 0.07 detection
Forced photometry reference-image weighted average: 14.38 +/- 0.05
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 16:30:15.62 +67:01:54.8: 99.00 +/- 99.00 edge
Forced photometry filter REJECTED candidate at 16:30:15.62 +67:01:54.8: at least one reference image reported edge (off-image or aperture/annulus past image boundary); cannot perform the forced-photometry cross-check
Forced photometry filter REJECTED candidate at 17:36:41.82 +59:42:15.8: ref_mag=14.38 +/- 0.05 new_mean_mag=14.2075 delta=0.17 (need > 0.90)
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:31:22.12 +64:13:43.8: 14.12 +/- 0.06 detection
Forced photometry reference-image weighted average: 14.09 +/- 0.04
Forced photometry filter REJECTED candidate at 17:31:22.12 +64:13:43.8: ref_mag=14.09 +/- 0.04 new_mean_mag=14.2444 delta=-0.16 (need > 0.90)
Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:06:15.62 +63:33:31.3: 13.87 +/- 0.05 detection
Forced photometry reference-image weighted average: 13.91 +/- 0.03
Forced photometry filter REJECTED candidate at 17:06:15.62 +63:33:31.3: ref_mag=13.91 +/- 0.03 new_mean_mag=14.1825 delta=-0.27 (need > 0.90)
make_report_in_HTML.sh Phase 1 (network queries): 4s
Pre-generating preview images in parallel...
Done pre-generating preview images.
Pre-generating finding charts in parallel...
Done pre-generating finding charts.
make_report_in_HTML.sh Pre-generation: 0s
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79093_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79093_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 1 | 2026 08 30.28218 | 2461282.78218 | 14.18 | 17:17:11.74 +64:44:45.6 | 4384 1531 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits |
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 14.20 | 17:17:11.95 +64:44:43.3 | 4381 1536 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79101_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79101_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 13.89 | 17:29:58.69 +65:12:42.7 | 3607 1153 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
**** FOUND 17:29:58.81 +65:12:41.8 in the exclusion list exclusion_list.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79102_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79102_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 1 | 2026 08 30.28218 | 2461282.78218 | 13.93 | 17:46:15.36 +61:20:16.9 | 2102 3247 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits |
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 13.79 | 17:46:15.29 +61:20:17.2 | 2098 3252 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79105_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79105_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 1 | 2026 08 30.28218 | 2461282.78218 | 14.03 | 18:07:44.75 +62:33:36.8 | 0797 2146 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits |
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 14.08 | 18:07:44.78 +62:33:37.9 | 0794 2150 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79106_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79106_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 1 | 2026 08 30.28218 | 2461282.78218 | 13.84 | 17:32:48.43 +65:31:09.3 | 3463 0936 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits |
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 14.18 | 17:32:48.43 +65:31:09.2 | 3460 0941 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79110_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79110_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 13.74 | 18:07:37.54 +59:35:49.7 | 0274 3876 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
**** FOUND 18:07:37.49 +59:35:49.8 in the exclusion list exclusion_list.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79113_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79113_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 13.62 | 18:13:31.58 +65:18:01.5 | 0925 0443 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
**** FOUND 18:13:31.52 +65:18:01.2 in the exclusion list exclusion_list.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79114_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79114_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 1 | 2026 08 30.28218 | 2461282.78218 | 13.16 | 16:05:49.82 +64:55:46.0 | 8961 1231 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits |
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 13.14 | 16:05:50.09 +64:55:46.0 | 8957 1237 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79116_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79116_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 1 | 2026 08 30.28218 | 2461282.78218 | 13.48 | 17:51:53.30 +62:07:28.2 | 1812 2695 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits |
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 13.48 | 17:51:53.28 +62:07:26.3 | 1809 2700 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79118_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79118_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 1 | 2026 08 30.28218 | 2461282.78218 | 12.94 | 16:04:37.96 +61:09:47.2 | 9450 3472 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits |
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 12.99 | 16:04:37.91 +61:09:47.1 | 9446 3478 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79119_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79119_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 1 | 2026 08 30.28218 | 2461282.78218 | 12.88 | 16:10:20.44 +65:10:28.0 | 8648 1134 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits |
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 12.87 | 16:10:20.44 +65:10:28.6 | 8645 1140 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79122_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79122_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 12.88 | 18:04:48.94 +59:39:55.5 | 0496 3897 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
**** FOUND 18:04:48.96 +59:39:55.7 in the exclusion list exclusion_list.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79123_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79123_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 1 | 2026 08 30.28218 | 2461282.78218 | 12.71 | 17:05:18.18 +66:17:33.6 | 5196 0655 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits |
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 13.01 | 17:05:18.28 +66:17:31.6 | 5194 0661 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79124_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79124_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 1 | 2026 08 30.28218 | 2461282.78218 | 12.78 | 17:22:49.71 +63:25:10.9 | 3927 2284 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits |
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 12.77 | 17:22:49.65 +63:25:11.0 | 3924 2289 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79127_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79127_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 12.29 | 17:13:47.19 +65:54:13.6 | 4660 0859 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
**** FOUND 17:13:47.23 +65:54:13.4 in the exclusion list exclusion_list.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79128_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79128_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 1 | 2026 08 30.28218 | 2461282.78218 | 11.65 | 16:08:19.31 +58:32:53.5 | 9446 5091 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits |
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 11.68 | 16:08:19.26 +58:32:53.2 | 9443 5097 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79130_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79130_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 11.61 | 18:04:54.74 +65:22:16.7 | 1465 0569 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
**** FOUND 18:04:54.76 +65:22:17.2 in the exclusion list exclusion_list.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79287_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79287_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 1 | 2026 08 30.28218 | 2461282.78218 | 11.80 | 18:03:26.29 +56:56:13.5 | 0138 5525 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits |
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 11.77 | 18:03:26.27 +56:56:13.3 | 0134 5530 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79369_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79369_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 12.36 | 17:56:14.17 +58:13:25.2 | 0916 4918 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
**** FOUND 17:56:14.16 +58:13:24.8 in the exclusion list exclusion_list.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79393_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79393_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 12.49 | 17:55:09.60 +58:44:24.7 | 1078 4634 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
**** FOUND 17:55:09.67 +58:44:24.5 in the exclusion list exclusion_list.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79430_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79430_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 12.50 | 17:26:15.72 +58:40:23.3 | 3307 5095 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
**** FOUND 17:26:15.72 +58:40:23.3 in the exclusion list exclusion_list_bsc.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79436_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79436_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 12.70 | 18:07:23.28 +61:13:09.3 | 0581 2937 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
**** FOUND 18:07:23.26 +61:13:09.2 in the exclusion list exclusion_list.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79440_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79440_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 12.65 | 17:34:43.54 +61:51:54.9 | 2973 3096 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
**** FOUND 17:34:43.51 +61:51:55.1 in the exclusion list exclusion_list_bsc.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79442_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79442_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 12.75 | 18:00:16.84 +57:20:18.5 | 0456 5360 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
**** FOUND 18:00:16.81 +57:20:18.7 in the exclusion list exclusion_list.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79446_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79446_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 12.68 | 17:25:55.06 +60:26:55.0 | 3478 4036 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
**** FOUND 17:25:55.03 +60:26:55.1 in the exclusion list exclusion_list.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79458_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79458_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 12.59 | 17:26:16.25 +58:38:40.0 | 3304 5112 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
**** FOUND 17:26:16.29 +58:38:40.5 in the exclusion list exclusion_list_bsc.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79460_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79460_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 1 | 2026 08 30.28218 | 2461282.78218 | 12.61 | 17:17:25.61 +57:24:52.3 | 3922 5929 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits |
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 12.67 | 17:17:25.68 +57:24:52.3 | 3918 5934 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79501_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79501_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 12.84 | 17:59:06.02 +63:58:36.7 | 1602 1489 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
**** FOUND 17:59:06.02 +63:58:36.6 in the exclusion list exclusion_list.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79502_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79502_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 12.62 | 17:08:25.95 +65:44:20.9 | 4982 0984 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
**** FOUND 17:08:25.90 +65:44:20.7 in the exclusion list exclusion_list_bbsc.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79513_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79513_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 12.94 | 18:02:42.61 +56:25:52.8 | 0107 5845 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
**** FOUND 18:02:42.63 +56:25:52.9 in the exclusion list exclusion_list.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79516_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79516_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 13.02 | 18:01:17.24 +56:59:36.6 | 0318 5543 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
**** FOUND 18:01:17.22 +56:59:36.5 in the exclusion list exclusion_list.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79570_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79570_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 1 | 2026 08 30.28218 | 2461282.78218 | 13.05 | 17:43:09.25 +60:46:55.6 | 2255 3622 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits |
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 13.09 | 17:43:09.24 +60:46:56.2 | 2252 3627 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79580_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79580_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 1 | 2026 08 30.28218 | 2461282.78218 | 13.11 | 17:59:31.32 +61:37:05.5 | 1205 2857 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits |
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 13.10 | 17:59:31.26 +61:37:05.9 | 1202 2862 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79601_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79601_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 13.14 | 18:13:59.80 +64:45:09.5 | 0792 0750 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
**** FOUND 18:13:59.69 +64:45:09.8 in the exclusion list exclusion_list.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79606_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79606_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 1 | 2026 08 30.28218 | 2461282.78218 | 13.17 | 17:55:59.45 +62:32:44.6 | 1592 2378 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits |
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 13.14 | 17:55:59.36 +62:32:44.9 | 1589 2382 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79665_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79665_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 1 | 2026 08 30.28218 | 2461282.78218 | 13.33 | 17:42:46.01 +58:40:02.6 | 2029 4883 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits |
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 13.32 | 17:42:46.10 +58:40:04.4 | 2025 4887 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79697_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79697_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 1 | 2026 08 30.28218 | 2461282.78218 | 13.38 | 17:32:55.24 +59:48:12.5 | 2903 4340 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits |
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 13.42 | 17:32:55.14 +59:48:12.5 | 2900 4344 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79710_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79710_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 1 | 2026 08 30.28218 | 2461282.78218 | 13.43 | 17:44:52.42 +60:19:56.0 | 2075 3863 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits |
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 13.40 | 17:44:52.29 +60:19:56.2 | 2071 3868 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79718_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79718_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 1 | 2026 08 30.28218 | 2461282.78218 | 13.36 | 17:05:33.07 +58:43:08.2 | 4928 5215 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits |
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 13.42 | 17:05:32.99 +58:43:08.5 | 4925 5220 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79731_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79731_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 13.14 | 16:48:42.62 +59:31:14.4 | 6238 4768 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
**** FOUND 16:48:42.57 +59:31:15.0 in the exclusion list exclusion_list.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79734_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79734_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 1 | 2026 08 30.28218 | 2461282.78218 | 13.58 | 18:00:05.36 +60:26:51.6 | 0978 3531 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits |
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 13.71 | 18:00:05.93 +60:26:50.3 | 0974 3536 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79735_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79735_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 13.46 | 16:19:16.22 +66:18:05.2 | 7993 0544 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
**** FOUND 16:19:16.28 +66:18:05.4 in the exclusion list exclusion_list.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79749_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79749_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 13.49 | 17:58:58.94 +64:07:57.6 | 1634 1400 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
**** FOUND 17:58:58.91 +64:07:57.7 in the exclusion list exclusion_list.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79753_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79753_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 13.72 | 18:08:04.13 +59:02:30.2 | 0141 4191 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
**** FOUND 18:08:04.11 +59:02:30.4 in the exclusion list exclusion_list.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79761_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79761_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 1 | 2026 08 30.28218 | 2461282.78218 | 13.49 | 17:35:41.26 +61:41:08.4 | 2890 3186 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits |
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 13.46 | 17:35:41.35 +61:41:09.0 | 2887 3191 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79764_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79764_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 1 | 2026 08 30.28218 | 2461282.78218 | 13.57 | 17:46:47.05 +59:14:44.9 | 1793 4477 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits |
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 13.55 | 17:46:47.60 +59:14:50.9 | 1789 4480 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79768_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79768_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 1 | 2026 08 30.28218 | 2461282.78218 | 13.66 | 18:09:12.50 +59:45:29.3 | 0189 3743 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits |
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 13.86 | 18:09:12.32 +59:45:29.4 | 0186 3747 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79775_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79775_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 1 | 2026 08 30.28218 | 2461282.78218 | 13.46 | 17:08:13.24 +61:23:04.9 | 4825 3598 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits |
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 13.46 | 17:08:13.21 +61:23:03.2 | 4822 3604 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79782_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79782_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 1 | 2026 08 30.28218 | 2461282.78218 | 13.56 | 17:28:21.15 +59:12:43.1 | 3195 4745 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits |
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 13.66 | 17:28:21.10 +59:12:43.5 | 3192 4750 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79822_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79822_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 1 | 2026 08 30.28218 | 2461282.78218 | 13.73 | 18:02:35.63 +60:34:38.0 | 0817 3406 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits |
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 13.59 | 18:02:35.58 +60:34:37.2 | 0814 3411 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79834_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79834_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 1 | 2026 08 30.28218 | 2461282.78218 | 13.78 | 18:00:13.80 +56:35:31.4 | 0342 5799 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits |
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 13.66 | 18:00:13.95 +56:35:31.1 | 0338 5804 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79843_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79843_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 13.38 | 17:31:28.24 +64:29:50.0 | 3447 1565 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
**** FOUND 17:31:28.23 +64:29:50.0 in the exclusion list exclusion_list.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79844_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79844_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 13.72 | 17:35:21.60 +64:21:46.7 | 3184 1604 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
**** FOUND 17:35:21.57 +64:21:46.3 in the exclusion list exclusion_list.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79860_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79860_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 1 | 2026 08 30.28218 | 2461282.78218 | 13.63 | 17:08:50.56 +58:05:25.3 | 4646 5579 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits |
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 13.63 | 17:08:50.67 +58:05:23.9 | 4642 5584 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79903_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79903_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 13.78 | 16:52:14.87 +61:41:08.5 | 5973 3463 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
**** FOUND 16:52:14.90 +61:41:07.7 in the exclusion list exclusion_list.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79921_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79921_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 1 | 2026 08 30.28218 | 2461282.78218 | 13.88 | 17:46:59.93 +59:16:45.0 | 1781 4453 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits |
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 13.83 | 17:47:00.39 +59:16:47.0 | 1777 4457 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79928_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79928_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 1 | 2026 08 30.28218 | 2461282.78218 | 13.88 | 17:42:33.70 +62:37:27.1 | 2518 2541 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits |
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 13.88 | 17:42:33.62 +62:37:26.4 | 2515 2545 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79951_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79951_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 1 | 2026 08 30.28218 | 2461282.78218 | 13.89 | 17:26:19.87 +61:24:57.2 | 3530 3449 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits |
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 13.93 | 17:26:19.85 +61:24:57.6 | 3527 3454 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79958_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79958_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 14.18 | 17:22:42.11 +60:08:27.4 | 3693 4250 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
**** FOUND 17:22:42.19 +60:08:26.7 in the exclusion list exclusion_list.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 79989_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 79989_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 13.88 | 18:20:39.96 +64:44:03.5 | 0373 0614 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
**** FOUND 18:20:39.94 +64:44:02.6 in the exclusion list exclusion_list.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 80007_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 80007_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 1 | 2026 08 30.28218 | 2461282.78218 | 13.98 | 17:51:45.98 +64:56:31.9 | 2215 1038 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits |
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 13.98 | 17:51:46.12 +64:56:32.3 | 2212 1042 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 80080_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 80080_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 1 | 2026 08 30.28218 | 2461282.78218 | 14.22 | 17:28:27.46 +59:02:56.4 | 3173 4841 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits |
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 14.21 | 17:28:26.96 +59:02:55.9 | 3170 4846 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 80082_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 80082_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 1 | 2026 08 30.28218 | 2461282.78218 | 14.16 | 17:36:41.82 +59:42:15.4 | 2610 4351 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits |
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 14.27 | 17:36:41.83 +59:42:16.3 | 2606 4356 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 80129_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 80129_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 1 | 2026 08 30.28218 | 2461282.78218 | 14.11 | 16:30:15.55 +67:01:54.1 | 7291 0169 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits |
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 14.16 | 16:30:15.69 +67:01:55.5 | 7288 0175 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 80131_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 80131_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 1 | 2026 08 30.28218 | 2461282.78218 | 14.22 | 17:06:15.34 +63:33:31.7 | 5043 2301 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits |
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 14.16 | 17:06:15.89 +63:33:30.9 | 5039 2306 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 80136_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 80136_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 1 | 2026 08 30.28218 | 2461282.78218 | 14.30 | 17:31:22.15 +64:13:43.6 | 3432 1722 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits |
| Discovery image 2 | 2026 08 30.28286 | 2461282.78286 | 14.21 | 17:31:22.09 +64:13:44.0 | 3429 1726 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 23831_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 23831_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 3 | 2026 08 30.28286 | 2461282.78286 | 11.14 | 17:07:12.75 +63:21:22.0 | 4968 2424 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
**** FOUND 17:07:12.77 +63:21:22.1 in the exclusion list exclusion_list.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 01059_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163
The candidate 01059_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163 did not pass the final checks
| Discovery image 3 | 2026 08 30.28286 | 2461282.78286 | 7.74 | 16:32:40.39 +66:45:16.2 | 7157 0355 | /data_ssd/NMW-TexasTech/workdir//img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits |
**** FOUND 16:32:40.41 +66:45:16.3 in the exclusion list exclusion_list.txt ****
make_report_in_HTML.sh Phase 2 (HTML assembly): 0s
make_report_in_HTML.sh TOTAL: 4s
Prepared the HTML report for the field Dra-07-Q1b1x1 with default.sex.telephoto_lens_vSTL
*------ done with default.sex.telephoto_lens_vSTL ------*
#### The local exclusion list is exclusion_list_local.txt ####
Source monitoring: measuring positions from /data_ssd/NMW-TexasTech/workdir/img_2026-08-30_CI_Dra-07-Q1b1x1_015038_TTUQ1b1x1_1869078_NwK2nPER/monitoring_positions.txt
Read 35995 stars from the SExtractor catalog wcsmag.cat
Detected star coordinate range: RA 238.1735 to 277.2354 deg, Dec +55.5436 to +67.3977 deg
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.00
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.01
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.02
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.03
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.04
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.05
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.06
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.07
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.08
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.09
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.10
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.11
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.12
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.13
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.14
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.15
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.16
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.17
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.18
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.19
Tycho-2 catalog search boundaries: RA 238.1735 to 277.2354 deg, Dec 55.5436 to 67.3977 deg
Loaded 9908 Tycho-2 stars within the image boundaries (VT and BT non-zero).
Relation between the catalog and instrumental magnitudes is written to calib.txt
Stars used for magnitude calibration (good matches): 6043 out of 6419 total matches.
Matched with Tycho-2 6419 out of 35995 detected stars.
util/calibrate_single_image_with_tycho2.sh: calibrated wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits via Tycho-2
util/pixel_flux_airmass_correction processing wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits
Observation time (mid-exposure, UTC): JD 2461282.78218 (FITS header)
Observing site: lat= +33.748056 deg lon= -101.958333 deg east-positive (SITELAT/SITELONG FITS header keywords)
Frame center (pixel 4788.5 3194.5): RA= 257.27988 deg Dec= +62.05000 deg
Frame center: alt= +33.564 deg az= 321.235 deg airmass= 1.8030
Header cross-check: CENTALT= 33.497 deg (difference +0.066 deg)
Header cross-check: AIRMASS= 1.8080 (we compute 1.8030)
Airmass zero-point fit: OK k= +0.2219 +/- 0.0125 mag/airmass N= 4300 airmass span 1.4822-2.3789 scatter 0.1778 mag
Source monitoring: airmass zero-point for wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-46-10_20.00sec_-0.00C_LIGHTs_0162.fits: OK +0.406773 -0.221881 1.8030 +0.2219 4300 0.8967 0.1778 1.4822 2.3789
Read 35982 stars from the SExtractor catalog wcsmag.cat
Detected star coordinate range: RA 238.1723 to 277.2341 deg, Dec +55.5819 to +67.4051 deg
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.00
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.01
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.02
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.03
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.04
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.05
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.06
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.07
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.08
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.09
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.10
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.11
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.12
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.13
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.14
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.15
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.16
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.17
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.18
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.19
Tycho-2 catalog search boundaries: RA 238.1723 to 277.2341 deg, Dec 55.5819 to 67.4051 deg
Loaded 9880 Tycho-2 stars within the image boundaries (VT and BT non-zero).
Relation between the catalog and instrumental magnitudes is written to calib.txt
Stars used for magnitude calibration (good matches): 6035 out of 6416 total matches.
Matched with Tycho-2 6416 out of 35982 detected stars.
util/calibrate_single_image_with_tycho2.sh: calibrated wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits via Tycho-2
util/pixel_flux_airmass_correction processing wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits
Observation time (mid-exposure, UTC): JD 2461282.78286 (FITS header)
Observing site: lat= +33.748056 deg lon= -101.958333 deg east-positive (SITELAT/SITELONG FITS header keywords)
Frame center (pixel 4788.5 3194.5): RA= 257.26955 deg Dec= +62.05885 deg
Frame center: alt= +33.448 deg az= 321.272 deg airmass= 1.8084
Header cross-check: CENTALT= 33.385 deg (difference +0.063 deg)
Header cross-check: AIRMASS= 1.8133 (we compute 1.8084)
Airmass zero-point fit: OK k= +0.2212 +/- 0.0124 mag/airmass N= 4342 airmass span 1.4844-2.3898 scatter 0.1772 mag
Source monitoring: airmass zero-point for wcs_fd_Dra-07-Q1b1x1_2026-08-30_01-47-08_20.00sec_0.00C_LIGHTs_0163.fits: OK +0.403962 -0.221236 1.8084 +0.2212 4342 0.9054 0.1772 1.4844 2.3898
########### Completed Dra-07-Q1b1x1 ###########
The analysis was running at tau
We are allowed to update the exclusion list at tau host
Found ../exclusion_list_TTUQ1.txt
#### The exclusion list before filtering-out asteroids, bad pixels and adding Gaia sources ####
###################################################################################
renamed 'exclusion_list_index_html.txt_noasteroids' -> 'exclusion_list_index_html.txt'
renamed 'exclusion_list_index_html.txt_nohotpixels' -> 'exclusion_list_index_html.txt'
# Count candidates with no identification (that also don't look like hot pix)
Found 0 unidentified candidates (excluding asteroids, hot pixels and known variable stars).
###################################################################################
0 candidates found (excluding asteroids and hot pixels)
This does not look like a test run
###################################################################################
exclusion_list_gaiadr2.txt NOT FOUND
exclusion_list_apass.txt NOT FOUND
IS_THIS_TEST_RUN=NO ALLOW_EXCLUSION_LIST_UPDATE= YES
#### Nothing to add to the exclusion list ####
The observatory MPC code is V36
############################################################
Positions of planets computed with util/planet_finder/main.py for JD(UT)2461282.78218398 -observatory V36
10:45:09.38 +09:42:41.2 Mercury (-1.6mag)
13:14:17.24 -11:17:14.0 Venus (-4.6mag)
06:52:03.56 +23:24:23.1 Mars (1.2mag)
09:02:20.12 +17:25:29.8 Jupiter (-1.8mag)
00:53:26.29 +02:50:59.1 Saturn (0.5mag)
04:13:28.38 +21:01:26.2 Uranus (5.7mag)
00:14:28.58 +00:01:44.1 Neptune (7.7mag)
20:26:11.20 -23:37:34.8 Pluto (14.5mag)
00:03:54.03 +02:53:26.7 Moon (-12.1mag)
-rw-r--r-- 1 apache apache 363 Aug 30 01:52 planets.txt
############################################################
Positions of selected moons from JPL HORIZONS for JD(UT)2461282.78218398:
09:02:18.26 +17:25:40.2 Io (6.2mag)
09:02:29.72 +17:24:44.6 Europa (6.3mag)
09:02:36.44 +17:24:11.3 Ganymede (5.6mag)
09:02:45.70 +17:23:28.4 Callisto (6.9mag)
08:59:53.92 +17:38:02.5 Himalia (15.7mag)
09:02:23.71 +17:25:14.2 Thebe (16.6mag)
08:59:33.93 +17:32:43.8 Elara (17.7mag)
09:06:22.82 +16:55:43.2 Pasiphae (17.9mag)
09:03:59.71 +17:41:07.0 Carme (19.0mag)
00:53:28.64 +02:50:22.3 Titan (8.4mag)
00:53:26.23 +02:50:39.2 Rhea (9.7mag)
00:53:58.04 +02:53:36.2 Iapetus (11.0mag)
00:53:11.96 +02:50:42.9 Hyperion (14.4mag)
00:52:21.80 +02:41:31.4 Phoebe (16.4mag)
-rw-r--r-- 1 apache apache 568 Aug 30 01:52 moons.txt
############################################################
Positions of selected spacecraft from JPL HORIZONS for JD(UT)2461282.78218398:
21:04:09.94 -07:06:23.1 JWST
17:32:46.12 +36:04:42.8 Chandra
10:29:07.81 -57:43:50.6 XMM-Newton
-rw-r--r-- 1 apache apache 96 Aug 30 01:52 spacecraft.txt
############################################################
Positions of bright comets computed with util/comet_finder/main.py for JD(UT)2461282.78218398 -observatory V36
03:34:56.44 +18:55:39.4 17.4mag P/1996 R2 (Lagerkvist)
18:00:44.93 -34:21:10.1 14.2mag P/2010 H2 (Vales)
07:13:09.70 -69:52:33.2 17.3mag C/2014 UN271 (Bernardinelli-Bernstein)
06:14:35.03 +33:29:51.9 17.7mag C/2017 K2 (PANSTARRS)
04:37:54.16 +44:07:59.4 15.4mag P/2021 N1 (ZTF)
22:20:02.56 +29:35:20.1 17.4mag C/2022 E2 (ATLAS)
07:03:46.90 +26:07:53.7 16.8mag C/2022 N2 (PANSTARRS)
10:42:04.76 +27:31:44.3 17.0mag C/2022 QE78 (ATLAS)
09:43:30.61 +05:16:21.0 18.0mag C/2022 R6 (PANSTARRS)
20:45:28.44 +62:40:02.3 18.0mag C/2023 H5 (Lemmon)
15:32:21.20 -14:56:30.5 14.7mag C/2023 R1 (PANSTARRS)
08:31:03.57 +32:25:38.3 15.7mag C/2024 E1 (Wierzchos)
15:05:51.89 +15:25:01.3 17.9mag C/2024 G6 (ATLAS)
18:39:30.26 +43:24:43.9 13.7mag C/2024 J3 (ATLAS)
20:37:34.08 +49:36:45.4 17.5mag C/2024 R4 (PANSTARRS)
05:30:58.44 -12:56:21.8 15.2mag C/2024 T5 (ATLAS)
07:08:27.45 +20:06:46.1 17.8mag C/2025 J1 (Borisov)
11:05:19.57 +19:22:50.7 17.0mag C/2025 V2 (Rankin)
13:13:15.31 +00:45:04.3 16.9mag C/2025 Y1 (ATLAS)
16:23:08.26 +75:14:52.3 16.3mag C/2026 A2 (Bok)
03:08:46.92 +46:18:25.2 17.4mag C/2026 B2 (Sun-Gao)
12:05:55.97 +10:37:02.9 17.5mag A/2026 E1
22:19:19.14 -34:04:36.1 13.2mag 10P/Tempel
11:42:51.50 -04:52:43.5 16.3mag 29P/Schwassmann-Wachmann
11:52:25.12 -02:32:15.2 17.5mag 63P/Wild
00:48:38.92 -06:33:52.0 15.4mag 65P/Gunn
06:23:21.60 +19:48:25.8 17.1mag 78P/Gehrels
03:15:40.05 +14:49:48.9 16.7mag 88P/Howell
08:48:28.63 +24:18:30.5 16.5mag 93P/Lovas
05:12:11.08 +25:31:37.0 17.6mag 112P/Urata-Niijima
07:07:29.06 +26:42:59.2 16.0mag 114P/Wiseman-Skiff
10:09:49.50 +22:31:46.3 14.9mag 123P/West-Hartley
12:29:13.71 -18:29:51.2 17.3mag 124P/Mrkos
06:07:20.40 +20:51:41.0 16.0mag 128P/Shoemaker-Holt
07:04:17.25 +17:33:26.0 17.9mag 131P/Mueller
23:56:19.15 +02:46:47.1 17.4mag 139P/Vaisala-Oterma
02:55:57.33 -18:15:38.0 15.7mag 161P/Hartley-IRAS
08:28:38.10 +37:58:11.6 16.2mag 162P/Siding Spring
10:03:47.03 +20:14:04.5 11.8mag 169P/NEAT
03:16:24.26 +09:02:06.3 14.5mag 220P/McNaught
04:25:54.24 +33:40:51.6 15.2mag 260P/McNaught
08:09:52.90 +36:28:36.1 17.3mag 295P/LINEAR
15:20:21.91 +00:39:21.8 17.9mag 391P/Kowalski
09:20:46.69 +17:15:42.4 17.9mag 450P/LONEOS
-rw-r--r-- 1 apache apache 2.2K Aug 30 01:52 comets.txt
############################################################
List of recent ASAS-SN transients from https://www.astronomy.ohio-state.edu/asassn/transients.html :
04:20:07.58 -42:26:59.90 AT2026zjy 2026-08-23.03 15.91
03:08:18.02 +11:54:46.50 SN2026ymb 2026-08-23.4 16.44
20:22:32.48 -50:45:14.30 SN2026yid 2026-08-22.82 15.13
04:24:28.39 -56:20:21.60 ASASSN-26ey 2026-08-20.02 15.55
16:46:37.81 -63:14:59.80 ASASSN-26ex 2026-08-18.78 3.63
21:28:47.85 +20:31:03.60 SN 2026sfn 2026-08-16.3 17.09
23:01:28.67 -61:00:39.00 SN 2026yib 2026-08-14.85 17.36
00:22:23.20 -32:16:02.70 SN 2026whu 2026-08-14.96 16.5
19:56:21.71 -37:24:19.90 ASASSN-26ew 2026-08-13.82 14.73
13:53:14.21 +00:26:52.00 SN 2026wkv 2026-08-10.12 15.83
05:21:07.61 +23:38:20.10 TCP J05210763+2338194 2026-08-10.59 9.34
01:28:20.49 +40:13:27.10 SN2026wpd 2026-08-9.34 16.37
23:47:50.87 +49:28:49.80 SN2026wjs 2026-08-9.35 17.12
16:03:20.92 +17:43:23.70 AT2026xau 2026-08-9.3 17.71
01:10:22.05 -09:34:08.50 SN2026weo 2026-08-7.46 15.76
00:56:54.35 -35:55:29.40 AT2026wdy 2026-08-5.05 16.08
22:08:07.63 -53:03:58.90 AT2026wek 2026-08-3.82 17.17
14:51:51.34 +66:13:24.60 ASASSN-26ev 2026-08-2.15 14.02
12:06:50.79 -36:16:06.20 SN2026wgm 2026-08-1.73 15.61
16:56:36.90 -59:29:26.00 ASASSN-26er 2026-07-25.82 15.09
01:21:27.83 -10:37:05.00 SN2026vbh 2026-07-25.61 15.97
21:17:31.59 +22:25:50.90 ASASSN-26eq 2026-07-24.37 15.13
18:53:36.89 +16:56:43.60 ASASSN-26ep 2026-07-23.47 -4.06
12:18:47.98 -30:48:47.50 ASASSN-26et 2026-07-22.76 13.98
13:00:47.82 +15:42:17.60 SN2026uwk 2026-07-21.75 16.38
18:52:31.11 -32:28:00.90 ASASSN-26en 2026-07-21.77 14.63
14:42:58.01 -62:32:59.10 ASASSN-26es 2026-07-20.79 15.36
20:12:45.57 -32:53:13.00 ASASSN-26em 2026-07-20.94 16.83
18:54:24.33 -46:11:51.70 ASASSN-26eu 2026-07-20.93 14.86
03:18:56.99 -80:55:10.40 AT2026ugi 2026-07-20.03 17.12
18:43:58.40 +24:22:41.80 ASASSN-26eo 2026-07-19.36 16.16
04:50:01.03 -02:22:33.80 ASASSN-26ej 2026-07-16.17 17.02
18:34:55.28 -31:41:00.90 ASASSN-26ek 2026-07-16.24 15.73
17:07:43.61 -44:21:53.50 ASASSN-26el 2026-07-15.86 16.01
14:45:08.35 +24:13:12.30 ASASSN-26ei 2026-07-16.17 16.46
10:00:46.44 -32:36:31.10 AT 2023mhb 2026-07-14.73 16.67
14:39:37.45 -11:22:36.20 AT 2026unl 2026-07-15.27 17.11
10:49:42.57 -11:25:55.80 ASASSN-26eh 2026-07-14.72 16.58
19:33:53.06 -07:15:00.80 ASASSN-22le 2026-07-14.15 15.5
02:45:40.52 -27:55:30.30 ASASSN-26ef 2026-07-12.35 15.86
23:26:43.80 +04:42:39.70 SN 2026qtn 2026-07-12.22 16.47
02:19:17.26 +28:57:15.40 ASASSN-26ec 2026-07-11.53 2.78
18:31:15.56 -05:34:31.50 AT2026stb 2026-07-11.28 -1.29
13:36:08.24 +23:29:05.00 AT2026pjf 2026-07-10.18 -0.72
17:33:39.82 +04:22:36.70 SN2026pir 2026-07-9.86 -0.66
11:21:41.26 -50:33:36.30 ASASSN-26ed 2026-07-8.8 -1.3
23:41:42.11 +26:29:49.10 AT2026qil 2026-07-9.3 16.15
20:21:30.50 -32:03:40.10 ASASSN-26ee 2026-07-7.22 15.53
19:37:44.09 -05:35:42.80 AT2026ryu 2026-07-7.17 14.88
11:06:55.46 -04:07:04.50 AT2026qqg 2026-07-5.01 16.82
19:07:23.69 -74:13:37.30 AT2026qly 2026-07-5.02 17.31
17:57:43.80 +27:18:40.10 ASASSN-26ea 2026-07-5.07 16.67
19:59:01.43 -32:07:34.30 ASASSN-26eb 2026-07-4.97 15.52
18:46:50.35 -57:44:13.20 SN 2026qqp 2026-07-5.03 -0.92
19:17:31.69 -39:55:29.90 ASASSN-26dz 2026-07-5.14 15.91
19:14:31.37 +12:03:52.90 AT 2026rdg 2026-07-3.43 11.81
04:05:50.09 -70:24:34.40 AT 2026qpr 2026-06-30.4 15.96
13:45:37.49 -05:59:35.80 SN 2026pub 2026-06-30.09 16.01
16:41:15.63 +39:17:14.70 SN 2026pel 2026-06-26.38 16.07
10:14:40.19 -35:38:21.30 ASASSN-26dy 2026-06-25.99 15.63
14:47:21.56 -40:15:51.30 ASASSN-26dv 2026-06-23.03 14.62
13:38:49.79 -77:21:06.70 ASASSN-26dw 2026-06-23.04 16.09
00:59:27.90 +33:08:13.20 SN 2026mke 2026-06-22.39 17.13
11:10:44.73 -30:20:45.50 SN 2026nmv 2026-06-22.06 16.56
21:36:15.68 -21:19:12.50 AT2026oxh 2026-06-22.15 17.14
17:31:38.38 -56:05:51.90 ASASSN-26dx 2026-06-22.02 14.72
14:10:13.44 -38:46:46.10 AT2026pvk 2026-06-22.06 16.53
20:56:47.23 -18:31:05.20 AT2026plb 2026-06-21.31 16.4
15:44:29.68 +21:00:59.30 SN2026ore 2026-06-21.29 17.57
23:50:05.98 -14:01:41.30 AT2026oxl 2026-06-21.52 17.64
17:36:54.73 -18:10:04.20 AT2026ouj 2026-06-20.92 15.15
00:34:04.08 -30:22:09.20 AT2026ntk 2026-06-18.09 17.34
20:49:13.39 +25:17:59.20 ASASSN-26du 2026-06-15.39 15.93
23:09:30.84 +32:40:42.00 SN2026oxc 2026-06-14.35 16.83
02:02:26.78 +32:04:21.30 AT2026ovz 2026-06-14.59 15.39
21:26:28.11 -72:31:19.50 AT2026nwc 2026-06-11 17.05
17:54:57.33 +26:32:34.20 SN 2026odc 2026-06-11.23 17.62
13:55:59.94 +17:30:37.20 SN 2026nyq 2026-06-11.1 16.24
00:50:45.14 -71:38:36.90 ASASSN-26dt 2026-06-11.13 10.22
14:42:19.73 +19:11:35.60 SN2026nyp 2026-06-10.3 16.32
12:23:23.92 +12:56:43.50 SN2026mta 2026-06-8.29 16.69
12:30:18.51 +47:12:33.20 SN2026oao 2026-06-9.32 17.02
10:51:05.21 -42:28:56.60 AT2026nvf 2026-06-8.12 16.75
13:50:22.48 -07:35:00.00 SN2026npn 2026-06-8.02 17.58
00:56:07.17 +43:01:43.20 ASASSN-26dq 2026-06-7.43 13.58
01:07:49.46 +41:59:43.70 SN 2026obc 2026-06-7.43 15.15
21:11:25.22 +14:14:31.90 ASASSN-26dr 2026-06-7.24 16.24
06:21:27.06 -65:16:42.00 ASASSN-26ds 2026-06-2.97 15.02
20:07:38.15 -21:07:05.40 SN2026mho 2026-05-25.18 -1.12
11:29:42.55 +79:01:03.10 AT2026min 2026-05-24.21 16.63
11:44:32.95 -68:48:30.00 ASASSN-26no 2026-05-24 8.41
19:00:42.82 -48:31:01.60 ASASSN-26dp 2026-05-22.31 -3.28
14:23:56.72 -58:37:47.60 ASASSN-26dn 2026-05-20.01 14.64
11:24:54.06 +47:57:01.60 AT2026nma 2026-05-20.29 15.46
21:27:08.58 +33:24:38.10 AT2026lli 2026-05-19.34 15.86
00:31:01.41 -13:38:51.70 AT2026nad 2026-05-19.39 15.34
15:16:06.61 -79:16:32.40 ASASSN-26dm 2026-05-19.03 14.44
11:24:25.21 -59:23:19.10 ASASSN-26dl 2026-05-18.02 13.55
13:45:51.52 -53:16:01.00 ASASSN-26dk 2026-05-18.16 12.96
02:05:49.69 -30:29:09.60 ASASSN-26dh 2026-05-18.43 15.37
-rw-r--r-- 1 apache apache 5.7K Aug 30 01:52 asassn_transients_list.txt
############################################################
Truncated list of TOCP transients from http://www.cbat.eps.harvard.edu/unconf/tocp.html :
02:19:17.36 +28:57:15.8 TCP J02191736+2857158 2026-07-12.3549 12.5mag
00:44:56.43 +41:57:41.6 PNV J00445643+4157416 2026-07-13.8026 17.98Cmag
00:42:55.36 +41:17:27.0 PNV J00425536+4117270 2026-07-20.1813 17.7mag
20:35:43.64 +61:31:32.9 TCP J20354364+6131329 2026-07-20.5443 14.4mag
21:17:31.48 +22:25:51.0 TCP J21173148+2225510 2026-07-23.5577 14.8mag
00:41:24.04 +40:49:02.8 PNV J00412404+4049028 2026-07-25.0157 18.7mag
00:43:04.26 +41:02:28.6 PNV J00430426+4102286 2026-07-26.1512 20mag
14:51:51.40 +66:13:24.0 TCP J14515140+6613240 2026-07-29.2561 13.5mag
00:43:06.15 +41:22:08.2 PNV J00430615+4122082 2026-07-30.0085 19.4mag
00:41:33.23 +41:10:12.2 PNV J00413323+4110122 2026-08-02.8913 17.1mag
05:21:07.63 +23:38:19.4 TCP J05210763+2338194 2026-08-06.4109 11.2mag
22:57:17.96 +47:07:41.8 TCP J22571796+4707418 2026-08-09.3289 14.3mag
09:13:38.17 +76:28:18.1 PSN J09133817+7628181 2026-08-09.8037 15.4mag
00:43:17.29 +41:26:48.6 PNV J00431729+4126486 2026-08-14.0920 16.8mag
00:42:52.82 +41:10:58.6 PNV J00425282+4110586 2026-08-17.7723 19.9mag
00:42:52.83 +41:10:59.6 PNV J00425283+4110596 2026-08-18.6119 19.3mag
18:25:12.76 -22:25:29.3 TCP J18251276-2225293 2026-08-19.1062 9.4mag
18:03:09.04 +12:18:14.0 TCP J18030904+1218140 2026-08-19.5199 14.9mag
19:45:06.48 +18:22:42.2 PNV J19450648+1822422 2026-08-25.1278 9.0mag
00:42:54.65 +41:22:59.3 PNV J00425465+4122593 2026-08-25.4712 18.9mag
-rw-r--r-- 1 apache apache 190K Aug 30 01:52 tocp_transients_list.txt
############################################################
Truncated list of recent TNS transients from https://www.wis-tns.org/ :
03:38:17.444 +00:23:41.68 AT 2026xug 2026-01-19.29 21.24
11:39:57.376 -13:21:58.15 AT 2026xuf 2026-01-28.56 20.99
14:55:24.436 -29:06:40.74 AT 2026xue 2026-02-26.58 20.26
15:22:19.621 -03:36:37.68 AT 2026xud 2026-02-28.61 20.75
11:32:20.348 -23:41:08.51 AT 2026xuc 2026-02-26.48 20.68
13:43:45.060 -29:09:34.37 AT 2026xub 2026-01-27.63 20.3
12:07:59.185 -24:02:54.78 AT 2026xua 2026-01-27.58 20.45
12:21:54.531 +01:48:01.30 AT 2026xtz 2026-02-27.59 20.65
15:09:21.323 -03:50:05.90 AT 2026xty 2026-02-28.61 21.2
12:03:52.398 -29:51:04.21 AT 2026xtx 2026-01-27.58 20.34
06:59:37.640 +46:41:37.44 AT 2026xtw 2026-01-19.40 21.74
13:29:47.826 +32:29:41.67 AT 2026xtv 2026-01-13.58 20.95
09:53:34.224 -03:24:04.10 AT 2026xtu 2026-01-27.47 21.41
03:19:42.171 -27:01:02.85 AT 2026xtt 2026-01-09.24 20.5
12:41:46.966 -27:29:06.49 AT 2026xts 2026-01-27.59 21.43
09:32:58.799 +01:54:41.76 AT 2026xtr 2026-01-26.43 21.7
05:04:53.740 -16:17:23.44 AT 2026xtq 2026-02-14.26 21.87
08:45:29.158 -06:14:27.46 AT 2026xtp 2026-01-27.42 21.93
10:49:35.708 +09:27:42.98 AT 2026xto 2026-01-20.44 21.07
10:28:09.548 -07:52:42.07 AT 2026xtn 2026-01-17.55 21.98
-rw-r--r-- 1 apache apache 88K Aug 30 01:52 tns_transients_list.txt