NMW transient search results

This analysis is done by the script util/transients/transient_factory_test31.sh /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp

The list of candidates will appear below. Please manually reload the page every few minutes untill the 'Processing complete' message appears.

Processing fields Dra-07-Q1b1x1

Processing complete!

Total number of candidates identified: 0

FITS images used in this processing run:

Field Dra-07-Q1b1x1 reference image: Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits
Field Dra-07-Q1b1x1 reference image: Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits
Field Dra-07-Q1b1x1 second-epoch image: Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits
Field Dra-07-Q1b1x1 second-epoch image: Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits

Processing log:

Filtering log:

######## Processing parameters ########
AAVSO_COMMENT_STRING= NMW-TexasTech Camera-1 135mm f/2.2 telephoto lens + QHY600M CMOS
ASTCHECK_ASTEROID_SEARCH_RADIUS_ARCSEC= 
BAD_REGION_FILE= /var/www/nmw_calibration/TTUQ1b1x1/TTUQ1_bad_region.lst
CAMERA_SETTINGS= TTUQ1b1x1
CHECK_POINTING_ACCURACY= yes
DARK_FRAMES_DIR_OR_FILE= /var/www/nmw_calibration/TTUQ1b1x1/darks
EXCLUSION_LIST= ../exclusion_list_TTUQ1.txt
FILTER_BAD_IMG__MAX_APERTURE_STAR_SIZE_PIX= 12.5
FILTER_BAD_IMG__MAX_ELONGATION_AminusB_PIX= 0.55
FILTER_BAD_IMG__MIN_APERTURE_STAR_SIZE_PIX= 2.0
FILTER_BRIGHT_MAG_CUTOFF_TRANSIENT_SEARCH= -5
FILTER_FAINT_MAG_CUTOFF_TRANSIENT_SEARCH= 15.5
FLAT_FIELD_DIR_OR_FILE= /var/www/nmw_calibration/TTUQ1b1x1/flats
FRAME_EDGE_OFFSET_PIX= 100
GAIA_BAND_FOR_CATALOGED_SOURCE_CHECK= 
MAX_NEW_TO_REF_MEAN_IMG_VALUE_RATIO= 100
DISABLE_NEW_TO_REF_MEAN_IMG_RATIO_CHECK= yes
MAX_NEW_IMG_MEAN_VALUE= 25000
MAX_SD_RATIO_OF_SECOND_EPOCH_IMGS= 0.18
MAX_SD_RATIO_OF_SECOND_EPOCH_IMGS_SOFT_LIMIT= 0.12
MPC_CODE= V36
NMW_CALIBRATION= /var/www/nmw_calibration
NUMBER_OF_DETECTED_TRANSIENTS_BEFORE_FILTERING_HARD_LIMIT= 10000
NUMBER_OF_DETECTED_TRANSIENTS_BEFORE_FILTERING_SOFT_LIMIT= 8000
OMP_NUM_THREADS= 3
ONLINE_MPCHECKER_BUTTON_ASTEROID_SEARCH_RADIUS_ARCMIN= 
PHOTOMETRIC_CALIBRATION= 
REQUIRE_PIX_SHIFT_BETWEEN_IMAGES_FOR_TRANSIENT_CANDIDATES= yes
SEXTRACTOR_CONFIG_BRIGHTSTARPASS= default.sex.telephoto_lens_onlybrightstars_v1
SEXTRACTOR_CONFIG_FILES= default.sex.telephoto_lens_onlybrightstars_v1 default.sex.telephoto_lens_vSTL
STARMATCH_RADIUS_PIX= 5
SYSREM_ITERATIONS= 0
TELESCOP= 
TELESCOP_NAME_KNOWN_TO_VaST_FOR_FOV_DETERMINATION= 
UCAC5_PLATESOLVE_ITERATIONS= 2
FPACK_FULLY_CALIBRATED_IMAGE= no
#######################################
HOSTNAME= tau
USER= 
HOME= 
#######################################
SExtractor catalog cache: enabled, directory /data_ssd/NMW-TexasTech/vast_sextractor_cache
Reference image directory is set to /data_ssd/NMW-TexasTech/reference_imgs
VIZIER_SITE=vizier.cds.unistra.fr
GAIA_DR2_CLIENT=vizquery (lib/vizquery -> VizieR vizier.cds.unistra.fr)
INFO: MAKE_PNG_PLOTS is set to yes
FITS_FILE_EXT=fits
CALIBRATION_STATUS_PREFIX=
Fields in the data directory: 
Dra-07-Q1b1x1
#######################################
########### Starting Dra-07-Q1b1x1 ###########
Processing Dra-07-Q1b1x1
server tau has sufficient free disk space available: 600179 MB at /data_ssd/NMW-TexasTech/workdir
server tau has sufficient free disk space available: 600179 MB at .
Checking input images (2 new)
REFERENCE_EPOCH__FIRST_IMAGE= /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits
REFERENCE_EPOCH__SECOND_IMAGE= /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits
Small preview (one of the new images): 
Large previews of the second-epoch (new) images:
MAKE_PNG_PLOTS=yes
renamed 'Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.png' -> 'transient_report/Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits_preview.png'
Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits

renamed 'Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.png' -> 'transient_report/Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits_preview.png'
Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits


Read-check the input FITS images... read-check OK Blank image check the input FITS images... blank-image-check OK Read date check the input FITS images... read-date-check OK Mean value check the input FITS images... OK, at least two new images have mean values below the threshold. ---------------------------------------------- INFO: REFERENCE_EPOCH__FIRST_IMAGE_MEAN_VALUE= 398.4182 INFO: REFERENCE_EPOCH__FIRST_IMAGE_SD= 518.6195 INFO: SECOND_EPOCH__FIRST_IMAGE_MEAN_VALUE= 4639.7004 INFO: SECOND_EPOCH__FIRST_IMAGE_SD= 1033.1592 INFO: SECOND_EPOCH__SECOND_IMAGE_MEAN_VALUE= 4680.8157 INFO: SECOND_EPOCH__SECOND_IMAGE_SD= 1040.1814 ---------------------------------------------- INFO: ref_to_second_epoch_img_mean_ratio= 11.6453 INFO: SECOND_EPOCH__SD_ratio= 0.007 INFO: the new-to-reference mean image value ratio check is disabled (DISABLE_NEW_TO_REF_MEAN_IMG_RATIO_CHECK=yes) - expected with a background-subtracted reference image ---------------------------------------------- Calibration settings: DARK_FRAMES_DIR_OR_FILE=/var/www/nmw_calibration/TTUQ1b1x1/darks FLAT_FIELD_DIR_OR_FILE=/var/www/nmw_calibration/TTUQ1b1x1/flats EXPTIME = 20.0 / [s] Exposure duration SET-TEMP= 0.0 / [degC] CCD temperature setpoint CCD-TEMP= -0.0 / [degC] CCD temperature FOCTEMP = 25.2900009155273 / [degC] Focuser temperature AMBTEMP = 22.9 / [degC] Ambient air temperature Exploring image header: /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits CCD-TEMP= -0.000000 for /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits SET-TEMP= 0.000000 for /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits Header: 74 keys total, 33 keys left Record 0: "" status=0 Record 1: "SIMPLE = T / C# FITS" status=0 Record 2: "BITPIX = 16" status=0 Record 3: "NAXIS = 2 / Dimensionality" status=0 Record 4: "NAXIS1 = 9576" status=0 Record 5: "NAXIS2 = 6388" status=0 Record 6: "BZERO = 32768" status=0 Record 7: "EXTEND = T / Extensions are permitted" status=0 Record 8: "IMAGETYP= 'LIGHT' / Type of exposure" status=0 Record 9: "EXPOSURE= 20.0 / [s] Exposure duration" status=0 Record 10: "EXPTIME = 20.0 / [s] Exposure duration" status=0 Record 11: "DATE-LOC= '2026-08-28T01:19:21.4074007' / Time of observation (local)" status=0 Record 12: "DATE-OBS= '2026-08-28T06:19:21.4074007' / Time of observation (UTC)" status=0 Record 13: "MJD-OBS = 61280.2634422109 / Modified Julian Date of observation" status=0 Record 14: "DATE-AVG= '2026-08-28T06:19:31.3083943' / Averaged midpoint time (UTC)" status=0 Record 15: "MJD-AVG = 61280.2635568054 / Modified Julian Date of averaged midpoint" status=0 Record 16: "XBINNING= 1 / X axis binning factor" status=0 Record 17: "YBINNING= 1 / Y axis binning factor" status=0 Record 18: "GAIN = 30 / Sensor gain" status=0 Record 19: "OFFSET = 30 / Sensor gain offset" status=0 Record 20: "XPIXSZ = 3.76 / [um] Pixel X axis size" status=0 Record 21: "YPIXSZ = 3.76 / [um] Pixel Y axis size" status=0 Record 22: "INSTRUME= 'QHY600M' / Imaging instrument name" status=0 Record 23: "CAMERAID= 'QHY600M-33d3d743814b8b447' / Imaging instrument identifier" status=0 Record 24: "SET-TEMP= 0.0 / [degC] CCD temperature setpoint" status=0 Record 25: "CCD-TEMP= -0.0 / [degC] CCD temperature" status=0 Record 26: "READOUTM= '2CMS-0' / Sensor readout mode" status=0 Record 27: "USBLIMIT= 50 / Camera-specific USB setting" status=0 Record 28: "TELESCOP= 'QHY600M-TTU1' / Name of telescope" status=0 Record 29: "FOCALLEN= 135.0 / [mm] Focal length" status=0 Record 30: "FOCRATIO= 2.2 / Focal ratio" status=0 Record 31: "RA = 257.138839401794 / [deg] RA of telescope" status=0 Record 32: "DEC = 62.0002369489972 / [deg] Declination of telescope" status=0 Record 33: "CENTALT = 37.5558333333333 / [deg] Altitude of telescope" status=0 Record 34: "CENTAZ = 325.629444444444 / [deg] Azimuth of telescope" status=0 Record 35: "AIRMASS = 1.63794245174212 / Airmass at frame center (Gueymard 1993)" status=0 Record 36: "PIERSIDE= 'East' / Telescope pointing state" status=0 Record 37: "SITEELEV= 1015.0 / [m] Observation site elevation" status=0 Record 38: "SITELAT = 33.7480555555556 / [deg] Observation site latitude" status=0 Record 39: "SITELONG= -101.958333333333 / [deg] Observation site longitude" status=0 Record 40: "OBSERVER= 'Sokolovsky' / Observer name" status=0 Record 41: "OBSERVAT= 'TTU Skyview' / Observatory name" status=0 Record 42: "SITENAME= '' / Observatory site name" status=0 Record 43: "FWHEEL = 'Simulator' / Filter Wheel name" status=0 Record 44: "FILTER = 'CV' / Active filter name" status=0 Record 45: "OBJECT = 'Dra-07' / Name of the object of interest" status=0 Record 46: "OBJCTRA = '17 08 34' / [H M S] RA of imaged object" status=0 Record 47: "OBJCTDEC= '+62 00 00' / [D M S] Declination of imaged object" status=0 Record 48: "OBJCTROT= 0.0 / [deg] planned rotation of imaged object" status=0 Record 49: "FOCNAME = 'ZWO Focuser' / Focusing equipment name" status=0 Record 50: "FOCPOS = 29533 / [step] Focuser position" status=0 Record 51: "FOCUSPOS= 29533 / [step] Focuser position" status=0 Record 52: "FOCUSSZ = 0.0 / [um] Focuser step size" status=0 Record 53: "FOCTEMP = 25.2900009155273 / [degC] Focuser temperature" status=0 Record 54: "FOCUSTEM= 25.2900009155273 / [degC] Focuser temperature" status=0 Record 55: "DEWPOINT= 14.2 / [degC] Dew point" status=0 Record 56: "HUMIDITY= 58.0 / [percent] Relative humidity" status=0 Record 57: "PRESSURE= 905.01 / [hPa] Air pressure" status=0 Record 58: "AMBTEMP = 22.9 / [degC] Ambient air temperature" status=0 Record 59: "WINDDIR = 337.0 / [deg] Wind direction: 0=N, 180=S, 90=E, 270=W" status=0 Record 60: "WINDGUST= 5.400432 / [kph] Wind gust" status=0 Record 61: "WINDSPD = 3.600288 / [kph] Wind speed" status=0 Record 62: "ROWORDER= 'TOP-DOWN' / FITS Image Orientation" status=0 Record 63: "EQUINOX = 2000.0 / Equinox of celestial coordinate system" status=0 Record 64: "SWCREATE= 'N.I.N.A. 3.2.0.9001 (x64)' / Software that created this file" status=0 Record 65: "QHY_EXP = 20.000096 / [s] Actual exposure time" status=0 Record 66: "QHY_PP = 13888.0 / [ps] pixelPeriod" status=0 Record 67: "QHY_LP = 85000.0 / [ns] linePeriod" status=0 Record 68: "GPS_LP = 85000.0 / [ns] linePeriod" status=0 Record 69: "QHY_FP = 20000160.0 / [us] framePeriod" status=0 Record 70: "QHY_CPL = 6120.0 / clocksPerLine" status=0 Record 71: "QHY_LPF = 235295.0 / linesPerFrame" status=0 Record 72: "QHY_AET = 20000096.0 / [us] actualExposureTime" status=0 Record 73: "QHY_LEM = T / isLongExposureMode" status=0 Record 74: "QHY_OFF0= 3767.777 / [us] RollingShutterEndOffset row 0" status=0 Allocating memory for image, dark and result arrays... Reading image /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits 9576 6388 16 bitpix SET-TEMP= 0.000000 for /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits SET-TEMP= 0.000000 for /var/www/nmw_calibration/TTUQ1b1x1/darks/mdark_TTUQ1b1x1_0C_20s_2026-08-12_multinight.fit CCD-TEMP= -0.000000 for /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits CCD-TEMP= -0.000000 for /var/www/nmw_calibration/TTUQ1b1x1/darks/mdark_TTUQ1b1x1_0C_20s_2026-08-12_multinight.fit Reading dark frame /var/www/nmw_calibration/TTUQ1b1x1/darks/mdark_TTUQ1b1x1_0C_20s_2026-08-12_multinight.fit 9576 6388 16 bitpix Dark frame is subtracted, output is written to /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/d_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits :) Spent 0.833976 seconds renamed 'mdark_TTUQ1b1x1_0C_20s_2026-08-12_multinight.png' -> 'transient_report/dark.png' try_to_calibrate_the_input_frame(): selected flat field /var/www/nmw_calibration/TTUQ1b1x1/flats/mff_TTUQ1b1x1_2026-08-12_multinight.fit from directory /var/www/nmw_calibration/TTUQ1b1x1/flats MegaDivider v7 Reading image /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/d_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits 9576 6388 16 bitpix Reading flat /var/www/nmw_calibration/TTUQ1b1x1/flats/mff_TTUQ1b1x1_2026-08-12_multinight.fit 9576 6388 16 bitpix Avarage count on flat field image: 36313.440328 Minimal real count (from overscan): 5 Output is written to /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits :) No overscan detected - all values seem high! (left_median=23343.0, right_median=27331.5) renamed 'mff_TTUQ1b1x1_2026-08-12_multinight.png' -> 'transient_report/flat.png' Using calibrated image CALIBRATED_SECOND_EPOCH__FIRST_IMAGE=/data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits EXPTIME = 20.0 / [s] Exposure duration SET-TEMP= 0.0 / [degC] CCD temperature setpoint CCD-TEMP= -0.0 / [degC] CCD temperature FOCTEMP = 25.2900009155273 / [degC] Focuser temperature AMBTEMP = 22.9 / [degC] Ambient air temperature Exploring image header: /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits CCD-TEMP= -0.000000 for /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits SET-TEMP= 0.000000 for /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits Header: 74 keys total, 33 keys left Record 0: "" status=0 Record 1: "SIMPLE = T / C# FITS" status=0 Record 2: "BITPIX = 16" status=0 Record 3: "NAXIS = 2 / Dimensionality" status=0 Record 4: "NAXIS1 = 9576" status=0 Record 5: "NAXIS2 = 6388" status=0 Record 6: "BZERO = 32768" status=0 Record 7: "EXTEND = T / Extensions are permitted" status=0 Record 8: "IMAGETYP= 'LIGHT' / Type of exposure" status=0 Record 9: "EXPOSURE= 20.0 / [s] Exposure duration" status=0 Record 10: "EXPTIME = 20.0 / [s] Exposure duration" status=0 Record 11: "DATE-LOC= '2026-08-28T01:20:15.4203576' / Time of observation (local)" status=0 Record 12: "DATE-OBS= '2026-08-28T06:20:15.4203576' / Time of observation (UTC)" status=0 Record 13: "MJD-OBS = 61280.2640673611 / Modified Julian Date of observation" status=0 Record 14: "DATE-AVG= '2026-08-28T06:20:25.3211227' / Averaged midpoint time (UTC)" status=0 Record 15: "MJD-AVG = 61280.2641819562 / Modified Julian Date of averaged midpoint" status=0 Record 16: "XBINNING= 1 / X axis binning factor" status=0 Record 17: "YBINNING= 1 / Y axis binning factor" status=0 Record 18: "GAIN = 30 / Sensor gain" status=0 Record 19: "OFFSET = 30 / Sensor gain offset" status=0 Record 20: "XPIXSZ = 3.76 / [um] Pixel X axis size" status=0 Record 21: "YPIXSZ = 3.76 / [um] Pixel Y axis size" status=0 Record 22: "INSTRUME= 'QHY600M' / Imaging instrument name" status=0 Record 23: "CAMERAID= 'QHY600M-33d3d743814b8b447' / Imaging instrument identifier" status=0 Record 24: "SET-TEMP= 0.0 / [degC] CCD temperature setpoint" status=0 Record 25: "CCD-TEMP= -0.0 / [degC] CCD temperature" status=0 Record 26: "READOUTM= '2CMS-0' / Sensor readout mode" status=0 Record 27: "USBLIMIT= 50 / Camera-specific USB setting" status=0 Record 28: "TELESCOP= 'QHY600M-TTU1' / Name of telescope" status=0 Record 29: "FOCALLEN= 135.0 / [mm] Focal length" status=0 Record 30: "FOCRATIO= 2.2 / Focal ratio" status=0 Record 31: "RA = 257.138839520473 / [deg] RA of telescope" status=0 Record 32: "DEC = 62.000236942879 / [deg] Declination of telescope" status=0 Record 33: "CENTALT = 37.4497222222222 / [deg] Altitude of telescope" status=0 Record 34: "CENTAZ = 325.635833333333 / [deg] Azimuth of telescope" status=0 Record 35: "AIRMASS = 1.64188006233177 / Airmass at frame center (Gueymard 1993)" status=0 Record 36: "PIERSIDE= 'East' / Telescope pointing state" status=0 Record 37: "SITEELEV= 1015.0 / [m] Observation site elevation" status=0 Record 38: "SITELAT = 33.7480555555556 / [deg] Observation site latitude" status=0 Record 39: "SITELONG= -101.958333333333 / [deg] Observation site longitude" status=0 Record 40: "OBSERVER= 'Sokolovsky' / Observer name" status=0 Record 41: "OBSERVAT= 'TTU Skyview' / Observatory name" status=0 Record 42: "SITENAME= '' / Observatory site name" status=0 Record 43: "FWHEEL = 'Simulator' / Filter Wheel name" status=0 Record 44: "FILTER = 'CV' / Active filter name" status=0 Record 45: "OBJECT = 'Dra-07' / Name of the object of interest" status=0 Record 46: "OBJCTRA = '17 08 34' / [H M S] RA of imaged object" status=0 Record 47: "OBJCTDEC= '+62 00 00' / [D M S] Declination of imaged object" status=0 Record 48: "OBJCTROT= 0.0 / [deg] planned rotation of imaged object" status=0 Record 49: "FOCNAME = 'ZWO Focuser' / Focusing equipment name" status=0 Record 50: "FOCPOS = 29533 / [step] Focuser position" status=0 Record 51: "FOCUSPOS= 29533 / [step] Focuser position" status=0 Record 52: "FOCUSSZ = 0.0 / [um] Focuser step size" status=0 Record 53: "FOCTEMP = 25.2900009155273 / [degC] Focuser temperature" status=0 Record 54: "FOCUSTEM= 25.2900009155273 / [degC] Focuser temperature" status=0 Record 55: "DEWPOINT= 14.2 / [degC] Dew point" status=0 Record 56: "HUMIDITY= 58.0 / [percent] Relative humidity" status=0 Record 57: "PRESSURE= 905.01 / [hPa] Air pressure" status=0 Record 58: "AMBTEMP = 22.9 / [degC] Ambient air temperature" status=0 Record 59: "WINDDIR = 337.0 / [deg] Wind direction: 0=N, 180=S, 90=E, 270=W" status=0 Record 60: "WINDGUST= 5.400432 / [kph] Wind gust" status=0 Record 61: "WINDSPD = 3.600288 / [kph] Wind speed" status=0 Record 62: "ROWORDER= 'TOP-DOWN' / FITS Image Orientation" status=0 Record 63: "EQUINOX = 2000.0 / Equinox of celestial coordinate system" status=0 Record 64: "SWCREATE= 'N.I.N.A. 3.2.0.9001 (x64)' / Software that created this file" status=0 Record 65: "QHY_EXP = 20.000096 / [s] Actual exposure time" status=0 Record 66: "QHY_PP = 13888.0 / [ps] pixelPeriod" status=0 Record 67: "QHY_LP = 85000.0 / [ns] linePeriod" status=0 Record 68: "GPS_LP = 85000.0 / [ns] linePeriod" status=0 Record 69: "QHY_FP = 20000160.0 / [us] framePeriod" status=0 Record 70: "QHY_CPL = 6120.0 / clocksPerLine" status=0 Record 71: "QHY_LPF = 235295.0 / linesPerFrame" status=0 Record 72: "QHY_AET = 20000096.0 / [us] actualExposureTime" status=0 Record 73: "QHY_LEM = T / isLongExposureMode" status=0 Record 74: "QHY_OFF0= 3767.777 / [us] RollingShutterEndOffset row 0" status=0 Allocating memory for image, dark and result arrays... Reading image /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits 9576 6388 16 bitpix SET-TEMP= 0.000000 for /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits SET-TEMP= 0.000000 for /var/www/nmw_calibration/TTUQ1b1x1/darks/mdark_TTUQ1b1x1_0C_20s_2026-08-12_multinight.fit CCD-TEMP= -0.000000 for /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits CCD-TEMP= -0.000000 for /var/www/nmw_calibration/TTUQ1b1x1/darks/mdark_TTUQ1b1x1_0C_20s_2026-08-12_multinight.fit Reading dark frame /var/www/nmw_calibration/TTUQ1b1x1/darks/mdark_TTUQ1b1x1_0C_20s_2026-08-12_multinight.fit 9576 6388 16 bitpix Dark frame is subtracted, output is written to /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/d_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits :) Spent 0.891414 seconds renamed 'mdark_TTUQ1b1x1_0C_20s_2026-08-12_multinight.png' -> 'transient_report/dark.png' try_to_calibrate_the_input_frame(): selected flat field /var/www/nmw_calibration/TTUQ1b1x1/flats/mff_TTUQ1b1x1_2026-08-12_multinight.fit from directory /var/www/nmw_calibration/TTUQ1b1x1/flats MegaDivider v7 Reading image /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/d_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits 9576 6388 16 bitpix Reading flat /var/www/nmw_calibration/TTUQ1b1x1/flats/mff_TTUQ1b1x1_2026-08-12_multinight.fit 9576 6388 16 bitpix Avarage count on flat field image: 36313.440328 Minimal real count (from overscan): 5 Output is written to /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits :) No overscan detected - all values seem high! (left_median=23343.0, right_median=27331.5) renamed 'mff_TTUQ1b1x1_2026-08-12_multinight.png' -> 'transient_report/flat.png' Using calibrated image CALIBRATED_SECOND_EPOCH__SECOND_IMAGE=/data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits Dark frame used to calibrate the second-epoch images:

Flat field used to calibrate the second-epoch images:

after the calibration attempt: SECOND_EPOCH__FIRST_IMAGE=/data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits SECOND_EPOCH__SECOND_IMAGE=/data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits Previews of the CALIBRATED second-epoch images:

fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits


fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits


Updating neverexclude_list.txt '/var/www/nmw_calibration/neverexclude_list.txt' -> './neverexclude_list.txt' Choosing bad regions list '/var/www/nmw_calibration/TTUQ1b1x1/TTUQ1_bad_region.lst' -> 'bad_region.lst' wait *------ default.sex.telephoto_lens_onlybrightstars_v1 ------* 'default.sex.telephoto_lens_onlybrightstars_v1' -> 'default.sex' Starting VaST with default.sex.telephoto_lens_onlybrightstars_v1 ./vast --noflagimage --starmatchraius 5 --matchstarnumber 500 --selectbestaperture --sysrem 0 --type 4 --maxsextractorflag 99 --UTC --nofind --nojdkeyword /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits SExtractor catalog cache: saved Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.cat to cache SExtractor catalog cache: saved Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits.cat to cache VaST run complete with default.sex.telephoto_lens_onlybrightstars_v1 The four input images were /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits Checking WCS cache directory local_wcs_cache Checking WCS cache directory /mnt/usb/NMW_NG/solved_reference_images Found WCS cache directory /mnt/usb/NMW_NG/solved_reference_images Checking WCS cache directory /home/NMW_web_upload/solved_reference_images Checking WCS cache directory /dataX/kirx/NMW_NG_rt3_autumn2019/solved_reference_images The reference JD(UT) for computing planet and comet positions: 2461280.76355795 Re-using ../asassn_transients_list.txt '../asassn_transients_list.txt' -> 'asassn_transients_list.txt' Re-using ../tocp_transients_list.txt '../tocp_transients_list.txt' -> 'tocp_transients_list.txt' Re-using ../tns_transients_list.txt '../tns_transients_list.txt' -> 'tns_transients_list.txt' Plate-solving the images wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits exists and is non-empty wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits exists and is non-empty wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits exists and is non-empty wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits exists and is non-empty ################################### # fov_of_wcs_calibrated_image.sh output for wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits (1st reference image) verification OK: wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits Image size: 937.4'x624.3' 15.6(deg)x10.4(deg) 9576x6388 pix Image scale: 5.87"/pix along the X axis and 5.86"/pix along the Y axis Image center: 17:08:33.660 +61:59:46.08 J2000 4789.000 3195.000 ################################### The image scale is 5.87"/pix, setting the soft and hard astrometric limits for filtering second-epoch detections: 5.9" and 8.8" ################################### # fov_of_wcs_calibrated_image.sh output for wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits (1st new image) verification OK: wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits Image size: 941.4'x626.6' 15.7(deg)x10.4(deg) 9576x6388 pix Image scale: 5.90"/pix along the X axis and 5.89"/pix along the Y axis Image center: 17:08:56.501 +61:59:31.28 J2000 4789.000 3195.000 ################################### ################################### # Check the image center offset between the reference and the first second-epoch image (pointing accuracy) Reference image center 17:08:33.660 +61:59:46.08 Second-epoch image center 17:08:56.501 +61:59:31.28 Angular distance between the image centers 0.0449 deg. Soft limit: 0.50 deg. Hard limit: 1.00 deg. ################################### ################################### # fov_of_wcs_calibrated_image.sh output for wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits (2nd new image) verification OK: wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits Image size: 941.4'x626.6' 15.7(deg)x10.4(deg) 9576x6388 pix Image scale: 5.90"/pix along the X axis and 5.89"/pix along the Y axis Image center: 17:08:59.468 +62:00:03.59 J2000 4789.000 3195.000 ################################### ################################### # Check the image center offset between the reference and the second second-epoch image (pointing accuracy) Reference image center 17:08:33.660 +61:59:46.08 Second-epoch image center 17:08:59.468 +62:00:03.59 Angular distance between the image centers 0.0507 deg. ################################### ################################### # Check the image center offset between the first and the second second-epoch image (shift should be applied between the second-epoch images) Second-epoch first image center 17:08:56.501 +61:59:31.28 Second-epoch second image center 17:08:59.468 +62:00:03.59 Angular distance between the image centers 0.01069 deg. ################################### Running solve_plate_with_UCAC5... Preparing for a parallel run Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits &> /tmp/tmp.6fFDs381HU Parallel run for /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits &> /tmp/tmp.eKKjF2e9dp Parallel run for /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits &> /tmp/tmp.SkjKQ5lScn Parallel run for /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits &> /tmp/tmp.YaEdYPN5EJ Parallel run for /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits Calibrating the magnitude scale Found non-empty wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits ____ Start of magnitude calibration ____ PHOTOMETRIC_CALIBRATION=TYCHO2_V Calibrating the magnitude scale with Tycho-2 stars util/transients/transient_factory_test31.sh is checking for the presence of non-empty wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits and wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat wait (drain background util/solve_plate_with_UCAC5 jobs before Tycho-2 calibration -- avoids wcs_.fits write race) Tycho-2 catalog is found at lib/catalogs/tycho2 Tycho-2 catalog and the derived bright star exclusion list are ready Checking for the presence of non-empty wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits and wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat Found non-empty wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits and wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat The reference image (wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits) and catalog (wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat) found 'wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat' -> 'wcsmag.cat' Read 10895 stars from the SExtractor catalog wcsmag.cat Detected star coordinate range: RA 237.9599 to 276.7126 deg, Dec +55.8532 to +67.2637 deg Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.00 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.01 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.02 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.03 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.04 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.05 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.06 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.07 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.08 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.09 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.10 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.11 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.12 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.13 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.14 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.15 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.16 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.17 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.18 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.19 Tycho-2 catalog search boundaries: RA 237.9599 to 276.7126 deg, Dec 55.8532 to 67.2637 deg Loaded 9346 Tycho-2 stars within the image boundaries (VT and BT non-zero). Relation between the catalog and instrumental magnitudes is written to calib.txt Stars used for magnitude calibration (good matches): 5972 out of 6265 total matches. Matched with Tycho-2 6265 out of 10895 detected stars. The calibration function type and coefficients are written to calib.txt_param util/calibrate_magnitude_scale 0.000000 1.000000 22.687350 a=0.000000 b=1.000000 c=22.687350 From vast_summary.log: estimated ref. image limiting mag.: -7.41 Updating vast_summary.log: Estimated ref. image limiting mag.: 15.28 Updated vast_limiting_magnitude.log with calibrated magnitudes Working... Please, PLEASE, be patient!!! All lightcurves processed! =) Estimated ref. image limiting mag.: 15.28
Lightcurve magnitude calibration plot:

Preparing per-reference-image forced-photometry calibration (method=tycho2 band=V) Read 10895 stars from the SExtractor catalog wcsmag.cat Detected star coordinate range: RA 237.9599 to 276.7126 deg, Dec +55.8532 to +67.2637 deg Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.00 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.01 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.02 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.03 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.04 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.05 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.06 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.07 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.08 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.09 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.10 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.11 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.12 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.13 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.14 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.15 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.16 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.17 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.18 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.19 Tycho-2 catalog search boundaries: RA 237.9599 to 276.7126 deg, Dec 55.8532 to 67.2637 deg Loaded 9346 Tycho-2 stars within the image boundaries (VT and BT non-zero). Relation between the catalog and instrumental magnitudes is written to calib.txt Stars used for magnitude calibration (good matches): 5972 out of 6265 total matches. Matched with Tycho-2 6265 out of 10895 detected stars. util/calibrate_single_image_with_tycho2.sh: calibrated wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits via Tycho-2
Single-image forced-photometry magnitude calibration plot for wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits:

Forced-photometry filter: reusing the VaST-run aperture from image00001.cat.aperture for wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits Forced-photometry filter: calibrated wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits -> calib.txt_param_ref_wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits (aperture=6.5) Read 10980 stars from the SExtractor catalog wcsmag.cat Detected star coordinate range: RA 237.9599 to 276.7127 deg, Dec +55.8529 to +67.2538 deg Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.00 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.01 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.02 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.03 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.04 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.05 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.06 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.07 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.08 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.09 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.10 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.11 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.12 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.13 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.14 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.15 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.16 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.17 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.18 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.19 Tycho-2 catalog search boundaries: RA 237.9599 to 276.7127 deg, Dec 55.8529 to 67.2538 deg Loaded 9334 Tycho-2 stars within the image boundaries (VT and BT non-zero). Relation between the catalog and instrumental magnitudes is written to calib.txt Stars used for magnitude calibration (good matches): 5977 out of 6269 total matches. Matched with Tycho-2 6269 out of 10980 detected stars. util/calibrate_single_image_with_tycho2.sh: calibrated wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits via Tycho-2
Single-image forced-photometry magnitude calibration plot for wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits:

Forced-photometry filter: reusing the VaST-run aperture from image00002.cat.aperture for wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits Forced-photometry filter: calibrated wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits -> calib.txt_param_ref_wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits (aperture=6.5) ____ End of magnitude calibration ____ Applying consolidated magnitude filters... Preparing the exclusion lists for this field Done with filtering Found 2 candidate transients before the final filtering. (Hard limit: 10000) Median FWHM seeing for isolated stars: 2.3 pix Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits 2.3 pix Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits 2.2 pix fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits 2.2 pix fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits Limiting magnitude estimates: 15.3 mag. Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits 15.3 mag. Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits 14.0 mag. fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits 14.0 mag. fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits All-image limiting magnitude estimate: 14.0 (SNR ) 11.1 (80% of stars) with default.sex.telephoto_lens_onlybrightstars_v1 The first estimate is the magnitude of a star detected with a signal-to-noise ratio of following Karpov (2025, Acta Polytechnica, 65, 50). This value should be representative of the faintest stars clearly visible in the image. The brighter of the limiting magnitude estimates for the two second-epoch images is reported here. The second estimate is the 80th percentile of the magnitude distribution of stars detected on all four images. This value is representative of the faintest object that may enter the candidate transients list. The hard cut-off for the candidate transients is 15.5 mag. Waiting for UCAC5 plate solver wait cp: cannot create regular file 'local_wcs_cache/': Not a directory ############ /tmp/tmp.6fFDs381HU (6) ############ Parsing command line arguments... WARNING from replace_file_with_symlink_if_filename_contains_white_spaces() the input file /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits is already a symlink and we do not allow symlinks on symlinks The guess is based on the existing WCS header. Trying to blindly solve the plate (local solve-field or remote server)... /data_ssd/NMW-TexasTech/workdir/vast_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits 571.0 Entering WCS image calibration mode. ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits WARNING from replace_file_with_symlink_if_filename_contains_white_spaces() the input file /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits is already a symlink and we do not allow symlinks on symlinks FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits verification OK: /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits It's a known telescope with plate solutions that are supposed to be good. The input image /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits has a WCS header - will blindly trust it is good... '/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits' -> 'wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits' This WCS solution (astrometrynet) will be kept as is, not refit by util/solve_plate_with_UCAC5 FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits WCS_IMAGE_NAME=wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits WCS-calibrated image found: wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits Checking if the catalog wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat corresponding to the image wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits alredy exist and is non-empty... Catalog wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat corresponding to the image wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits found. The catalog is in the new format, as expected. The plate-solved (WCS-calibrated) image is saved to wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits WCS catalog name: wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat Excluding image region: 190.0 1039.0 192.0 1041.0 (defined in bad_region.lst) Excluding image region: 226.0 1548.0 228.0 1550.0 (defined in bad_region.lst) Excluding image region: 351.0 1875.0 353.0 1877.0 (defined in bad_region.lst) Excluding image region: 501.0 5912.0 503.0 5914.0 (defined in bad_region.lst) Excluding image region: 638.0 5545.0 640.0 5547.0 (defined in bad_region.lst) Excluding image region: 724.0 2731.0 726.0 2733.0 (defined in bad_region.lst) Excluding image region: 883.0 1376.0 885.0 1378.0 (defined in bad_region.lst) Excluding image region: 901.0 3972.0 903.0 3974.0 (defined in bad_region.lst) Excluding image region: 1151.0 918.0 1153.0 920.0 (defined in bad_region.lst) Excluding image region: 1157.0 135.0 1159.0 137.0 (defined in bad_region.lst) Excluding more image regions!.. (will not print them all) Excluded a total of 50 image regions (defined in bad_region.lst). SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=0, blended=730, bad_region=0, passed=10895 Got 10895 stars (including 10157 good ones) from the SExtractor catalog wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat util/solve_plate_with_UCAC5 got 10895 stars from the SExtractor catalog Updated FoV from the plate-solved image: 937.4' Seting catalog search parameters based on the expected field of view 937.4 arcmin UCAC5 catalog search parameters: catalog_search_parameters->search_radius_deg= 0.013019 (46.9 arcsec) catalog_search_parameters->brightest_mag= 1.00 catalog_search_parameters->faintest_mag= 13.50 catalog_search_parameters->search_radius_second_step_deg 0.010416 (37.5 arcsec) ITERATION 01 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50 Reading UCAC5 zone files... Searching UCAC5 zones 729 to 788 (Dec 55.9 to 67.3) Done reading UCAC5 zone files... Matched 4913 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Correcting the measured astrometric positions... Accuracy estimation diagnostic: 4903 matched stars entering correct_measured_positions(), 4903 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.37" Removing outliers... Correcting the measured astrometric positions... Accuracy estimation diagnostic: 4903 matched stars entering correct_measured_positions(), 10895 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.37" ITERATION 02 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50 Reading UCAC5 zone files... Searching UCAC5 zones 729 to 788 (Dec 55.9 to 67.3) Done reading UCAC5 zone files... Matched 4913 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Accuracy estimation diagnostic: 4903 matched stars entering correct_measured_positions(), 10895 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.38" Accuracy estimation diagnostic: 4903 matched stars entering correct_measured_positions(), 10895 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.40" Excluding outliers - 4903 stars left (next iteration limit 5393) Stop iterations. The field is successfully solved and matched with the astrometric catalog! :) SIP_REFIT: util/identify.sh trusts the WCS of wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits (astrometrynet) - keeping it, no refit (set VAST_FORCE_SIP_REFIT=1 to refit anyway) WCS_QUALITY_DIAG: file=Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits N_match=4903 sigma_overall_arcsec=0.426 sigma_q1_arcsec=0.372 sigma_q2_arcsec=0.460 sigma_q3_arcsec=0.495 sigma_q4_arcsec=0.402 n_q1=1378 n_q2=1176 n_q3=1215 n_q4=1134 worst_quadrant_to_overall_ratio=1.161 The image catalog is written to wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat.ucac5 The DS9 region file with the matched stars is written to wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat.ds9.reg You may view it with the command: ds9 /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits -region wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat.ds9.reg The astrometric residuals vector field is written to wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat.astrometric_residuals Option '-n' not using photometric catalogs, just stick with astrometry opt '-i': 2 is the maximum number of iterations FORCED_PHOTOMETRY_CALIBRATION_METHOD=tycho2 - not using remote photometric catalogs, just stick with astrometry ############ /tmp/tmp.eKKjF2e9dp (6) ############ Parsing command line arguments... WARNING from replace_file_with_symlink_if_filename_contains_white_spaces() the input file /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits is already a symlink and we do not allow symlinks on symlinks The guess is based on the existing WCS header. Trying to blindly solve the plate (local solve-field or remote server)... /data_ssd/NMW-TexasTech/workdir/vast_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits 571.0 Entering WCS image calibration mode. ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits WARNING from replace_file_with_symlink_if_filename_contains_white_spaces() the input file /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits is already a symlink and we do not allow symlinks on symlinks FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits verification OK: /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits It's a known telescope with plate solutions that are supposed to be good. The input image /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits has a WCS header - will blindly trust it is good... '/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits' -> 'wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits' This WCS solution (astrometrynet) will be kept as is, not refit by util/solve_plate_with_UCAC5 FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits WCS_IMAGE_NAME=wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits WCS-calibrated image found: wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits Checking if the catalog wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits.wcscat corresponding to the image wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits alredy exist and is non-empty... Catalog wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits.wcscat corresponding to the image wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits found. The catalog is in the new format, as expected. The plate-solved (WCS-calibrated) image is saved to wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits WCS catalog name: wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits.wcscat Excluding image region: 190.0 1039.0 192.0 1041.0 (defined in bad_region.lst) Excluding image region: 226.0 1548.0 228.0 1550.0 (defined in bad_region.lst) Excluding image region: 351.0 1875.0 353.0 1877.0 (defined in bad_region.lst) Excluding image region: 501.0 5912.0 503.0 5914.0 (defined in bad_region.lst) Excluding image region: 638.0 5545.0 640.0 5547.0 (defined in bad_region.lst) Excluding image region: 724.0 2731.0 726.0 2733.0 (defined in bad_region.lst) Excluding image region: 883.0 1376.0 885.0 1378.0 (defined in bad_region.lst) Excluding image region: 901.0 3972.0 903.0 3974.0 (defined in bad_region.lst) Excluding image region: 1151.0 918.0 1153.0 920.0 (defined in bad_region.lst) Excluding image region: 1157.0 135.0 1159.0 137.0 (defined in bad_region.lst) Excluding more image regions!.. (will not print them all) Excluded a total of 50 image regions (defined in bad_region.lst). SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=0, blended=731, bad_region=0, passed=10980 Got 10980 stars (including 10231 good ones) from the SExtractor catalog wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits.wcscat util/solve_plate_with_UCAC5 got 10980 stars from the SExtractor catalog Updated FoV from the plate-solved image: 937.3' Seting catalog search parameters based on the expected field of view 937.3 arcmin UCAC5 catalog search parameters: catalog_search_parameters->search_radius_deg= 0.013018 (46.9 arcsec) catalog_search_parameters->brightest_mag= 1.00 catalog_search_parameters->faintest_mag= 13.50 catalog_search_parameters->search_radius_second_step_deg 0.010414 (37.5 arcsec) ITERATION 01 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50 Reading UCAC5 zone files... Searching UCAC5 zones 729 to 788 (Dec 55.9 to 67.3) Done reading UCAC5 zone files... Matched 4914 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Correcting the measured astrometric positions... Accuracy estimation diagnostic: 4904 matched stars entering correct_measured_positions(), 4904 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.36" Removing outliers... Correcting the measured astrometric positions... Accuracy estimation diagnostic: 4904 matched stars entering correct_measured_positions(), 10980 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.36" ITERATION 02 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50 Reading UCAC5 zone files... Searching UCAC5 zones 729 to 788 (Dec 55.9 to 67.3) Done reading UCAC5 zone files... Matched 4914 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Accuracy estimation diagnostic: 4904 matched stars entering correct_measured_positions(), 10980 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.37" Accuracy estimation diagnostic: 4904 matched stars entering correct_measured_positions(), 10980 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.38" Excluding outliers - 4904 stars left (next iteration limit 5394) Stop iterations. The field is successfully solved and matched with the astrometric catalog! :) SIP_REFIT: util/identify.sh trusts the WCS of wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits (astrometrynet) - keeping it, no refit (set VAST_FORCE_SIP_REFIT=1 to refit anyway) WCS_QUALITY_DIAG: file=Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits N_match=4904 sigma_overall_arcsec=0.397 sigma_q1_arcsec=0.344 sigma_q2_arcsec=0.439 sigma_q3_arcsec=0.469 sigma_q4_arcsec=0.370 n_q1=1378 n_q2=1177 n_q3=1213 n_q4=1136 worst_quadrant_to_overall_ratio=1.182 The image catalog is written to wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits.wcscat.ucac5 The DS9 region file with the matched stars is written to wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits.wcscat.ds9.reg You may view it with the command: ds9 /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits -region wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits.wcscat.ds9.reg The astrometric residuals vector field is written to wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits.wcscat.astrometric_residuals Option '-n' not using photometric catalogs, just stick with astrometry opt '-i': 2 is the maximum number of iterations FORCED_PHOTOMETRY_CALIBRATION_METHOD=tycho2 - not using remote photometric catalogs, just stick with astrometry ############ /tmp/tmp.SkjKQ5lScn (6) ############ Parsing command line arguments... The minor axis of the CCD chip should be 24.0 mm based on the derived pixel size of 3.8 um Internal estimated FoV 605.3' The guess is based on the FOCALLEN keyword. Trying to blindly solve the plate (local solve-field or remote server)... /data_ssd/NMW-TexasTech/workdir/vast_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits 605.0 Entering WCS image calibration mode. ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits verification OK: /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits It's not one of the telescopes that are know to produce images with good WCS solutions - will try to re-solve! FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits WCS_IMAGE_NAME=wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits WCS-calibrated image found: wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits Checking if the catalog wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits.wcscat corresponding to the image wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits alredy exist and is non-empty... Catalog wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits.wcscat corresponding to the image wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits found. The catalog is in the new format, as expected. The plate-solved (WCS-calibrated) image is saved to wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits WCS catalog name: wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits.wcscat Excluding image region: 190.0 1039.0 192.0 1041.0 (defined in bad_region.lst) Excluding image region: 226.0 1548.0 228.0 1550.0 (defined in bad_region.lst) Excluding image region: 351.0 1875.0 353.0 1877.0 (defined in bad_region.lst) Excluding image region: 501.0 5912.0 503.0 5914.0 (defined in bad_region.lst) Excluding image region: 638.0 5545.0 640.0 5547.0 (defined in bad_region.lst) Excluding image region: 724.0 2731.0 726.0 2733.0 (defined in bad_region.lst) Excluding image region: 883.0 1376.0 885.0 1378.0 (defined in bad_region.lst) Excluding image region: 901.0 3972.0 903.0 3974.0 (defined in bad_region.lst) Excluding image region: 1151.0 918.0 1153.0 920.0 (defined in bad_region.lst) Excluding image region: 1157.0 135.0 1159.0 137.0 (defined in bad_region.lst) Excluding more image regions!.. (will not print them all) Excluded a total of 50 image regions (defined in bad_region.lst). SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=0, blended=387, bad_region=0, passed=4136 Got 4136 stars (including 3741 good ones) from the SExtractor catalog wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits.wcscat util/solve_plate_with_UCAC5 got 4136 stars from the SExtractor catalog Updated FoV from the plate-solved image: 941.4' Seting catalog search parameters based on the expected field of view 941.4 arcmin UCAC5 catalog search parameters: catalog_search_parameters->search_radius_deg= 0.013075 (47.1 arcsec) catalog_search_parameters->brightest_mag= 1.00 catalog_search_parameters->faintest_mag= 13.50 catalog_search_parameters->search_radius_second_step_deg 0.010460 (37.7 arcsec) ITERATION 01 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50 Reading UCAC5 zone files... Searching UCAC5 zones 728 to 788 (Dec 55.6 to 67.3) Done reading UCAC5 zone files... Matched 3663 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Correcting the measured astrometric positions... Accuracy estimation diagnostic: 3657 matched stars entering correct_measured_positions(), 3657 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.29" Removing outliers... Correcting the measured astrometric positions... Accuracy estimation diagnostic: 3657 matched stars entering correct_measured_positions(), 4136 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.29" ITERATION 02 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50 Reading UCAC5 zone files... Searching UCAC5 zones 728 to 788 (Dec 55.6 to 67.3) Done reading UCAC5 zone files... Matched 3664 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Accuracy estimation diagnostic: 3658 matched stars entering correct_measured_positions(), 4136 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.30" Accuracy estimation diagnostic: 3658 matched stars entering correct_measured_positions(), 4136 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.30" Excluding outliers - 3658 stars left (next iteration limit 4022) Stop iterations. The field is successfully solved and matched with the astrometric catalog! :) SIP_REFIT: SIP order 2 trial: matched=3658 robust_rms=10.606 arcsec worst_quadrant_rms=13.903 arcsec SIP_REFIT: SIP order 3 trial: matched=3658 robust_rms=0.417 arcsec worst_quadrant_rms=0.452 arcsec SIP_REFIT: SIP order 5 trial: matched=3658 robust_rms=0.304 arcsec worst_quadrant_rms=0.317 arcsec SIP_REFIT: selected SIP order 5 SIP_REFIT: order=5 matched=3658 robust_rms_before=0.669 arcsec robust_rms_before_corrected=0.316 arcsec robust_rms_after=0.304 arcsec worst_quadrant_rms_before=0.343 worst_quadrant_rms_after=0.317 SIP_REFIT: refit does not sufficiently improve on the solution it would replace (best worst-quadrant baseline 0.343 arcsec) - keeping the original WCS_QUALITY_DIAG: file=fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits N_match=3658 sigma_overall_arcsec=0.318 sigma_q1_arcsec=0.335 sigma_q2_arcsec=0.319 sigma_q3_arcsec=0.329 sigma_q4_arcsec=0.286 n_q1=1008 n_q2=827 n_q3=984 n_q4=839 worst_quadrant_to_overall_ratio=1.054 The image catalog is written to wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits.wcscat.ucac5 The DS9 region file with the matched stars is written to wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits.wcscat.ds9.reg You may view it with the command: ds9 /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits -region wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits.wcscat.ds9.reg The astrometric residuals vector field is written to wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits.wcscat.astrometric_residuals Option '-n' not using photometric catalogs, just stick with astrometry opt '-i': 2 is the maximum number of iterations FORCED_PHOTOMETRY_CALIBRATION_METHOD=tycho2 - not using remote photometric catalogs, just stick with astrometry ############ /tmp/tmp.YaEdYPN5EJ (6) ############ Parsing command line arguments... The minor axis of the CCD chip should be 24.0 mm based on the derived pixel size of 3.8 um Internal estimated FoV 605.3' The guess is based on the FOCALLEN keyword. Trying to blindly solve the plate (local solve-field or remote server)... /data_ssd/NMW-TexasTech/workdir/vast_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits 605.0 Entering WCS image calibration mode. ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits verification OK: /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits It's not one of the telescopes that are know to produce images with good WCS solutions - will try to re-solve! FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits WCS_IMAGE_NAME=wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits WCS-calibrated image found: wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits Checking if the catalog wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits.wcscat corresponding to the image wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits alredy exist and is non-empty... Catalog wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits.wcscat corresponding to the image wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits found. The catalog is in the new format, as expected. The plate-solved (WCS-calibrated) image is saved to wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits WCS catalog name: wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits.wcscat Excluding image region: 190.0 1039.0 192.0 1041.0 (defined in bad_region.lst) Excluding image region: 226.0 1548.0 228.0 1550.0 (defined in bad_region.lst) Excluding image region: 351.0 1875.0 353.0 1877.0 (defined in bad_region.lst) Excluding image region: 501.0 5912.0 503.0 5914.0 (defined in bad_region.lst) Excluding image region: 638.0 5545.0 640.0 5547.0 (defined in bad_region.lst) Excluding image region: 724.0 2731.0 726.0 2733.0 (defined in bad_region.lst) Excluding image region: 883.0 1376.0 885.0 1378.0 (defined in bad_region.lst) Excluding image region: 901.0 3972.0 903.0 3974.0 (defined in bad_region.lst) Excluding image region: 1151.0 918.0 1153.0 920.0 (defined in bad_region.lst) Excluding image region: 1157.0 135.0 1159.0 137.0 (defined in bad_region.lst) Excluding more image regions!.. (will not print them all) Excluded a total of 50 image regions (defined in bad_region.lst). SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=0, blended=391, bad_region=0, passed=4102 Got 4102 stars (including 3707 good ones) from the SExtractor catalog wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits.wcscat util/solve_plate_with_UCAC5 got 4102 stars from the SExtractor catalog Updated FoV from the plate-solved image: 941.4' Seting catalog search parameters based on the expected field of view 941.4 arcmin UCAC5 catalog search parameters: catalog_search_parameters->search_radius_deg= 0.013075 (47.1 arcsec) catalog_search_parameters->brightest_mag= 1.00 catalog_search_parameters->faintest_mag= 13.50 catalog_search_parameters->search_radius_second_step_deg 0.010460 (37.7 arcsec) ITERATION 01 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50 Reading UCAC5 zone files... Searching UCAC5 zones 728 to 788 (Dec 55.6 to 67.3) Done reading UCAC5 zone files... Matched 3631 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Correcting the measured astrometric positions... Accuracy estimation diagnostic: 3626 matched stars entering correct_measured_positions(), 3626 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.30" Removing outliers... Correcting the measured astrometric positions... Accuracy estimation diagnostic: 3626 matched stars entering correct_measured_positions(), 4102 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.30" ITERATION 02 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50 Reading UCAC5 zone files... Searching UCAC5 zones 728 to 788 (Dec 55.6 to 67.3) Done reading UCAC5 zone files... Matched 3632 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Accuracy estimation diagnostic: 3627 matched stars entering correct_measured_positions(), 4102 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.31" Accuracy estimation diagnostic: 3627 matched stars entering correct_measured_positions(), 4102 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.31" Excluding outliers - 3627 stars left (next iteration limit 3988) Stop iterations. The field is successfully solved and matched with the astrometric catalog! :) SIP_REFIT: SIP order 2 trial: matched=3627 robust_rms=10.730 arcsec worst_quadrant_rms=14.137 arcsec SIP_REFIT: SIP order 3 trial: matched=3627 robust_rms=0.421 arcsec worst_quadrant_rms=0.446 arcsec SIP_REFIT: SIP order 5 trial: matched=3627 robust_rms=0.304 arcsec worst_quadrant_rms=0.329 arcsec SIP_REFIT: selected SIP order 5 SIP_REFIT: order=5 matched=3627 robust_rms_before=0.652 arcsec robust_rms_before_corrected=0.322 arcsec robust_rms_after=0.304 arcsec worst_quadrant_rms_before=0.335 worst_quadrant_rms_after=0.329 SIP_REFIT: refit does not sufficiently improve on the solution it would replace (best worst-quadrant baseline 0.335 arcsec) - keeping the original WCS_QUALITY_DIAG: file=fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits N_match=3627 sigma_overall_arcsec=0.331 sigma_q1_arcsec=0.340 sigma_q2_arcsec=0.332 sigma_q3_arcsec=0.324 sigma_q4_arcsec=0.302 n_q1=1011 n_q2=817 n_q3=975 n_q4=824 worst_quadrant_to_overall_ratio=1.026 The image catalog is written to wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits.wcscat.ucac5 The DS9 region file with the matched stars is written to wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits.wcscat.ds9.reg You may view it with the command: ds9 /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits -region wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits.wcscat.ds9.reg The astrometric residuals vector field is written to wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits.wcscat.astrometric_residuals Option '-n' not using photometric catalogs, just stick with astrometry opt '-i': 2 is the maximum number of iterations FORCED_PHOTOMETRY_CALIBRATION_METHOD=tycho2 - not using remote photometric catalogs, just stick with astrometry Saving the final (post-refit) wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits to local_wcs_cache/ 'wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits' -> 'local_wcs_cache/wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits' Saving the final (post-refit) wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits to local_wcs_cache/ 'wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits' -> 'local_wcs_cache/wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits' Saving the final (post-refit) wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits to local_wcs_cache/ 'wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits' -> 'local_wcs_cache/wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits' Saving the final (post-refit) wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits to local_wcs_cache/ 'wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits' -> 'local_wcs_cache/wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits' ################################### # Pre-local-correction WCS quality summary (see WCS_QUALITY_DIAG lines above) ref1=Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits sigma_overall=0.426 worst_q_ratio=1.161 ref2=Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits sigma_overall=0.397 worst_q_ratio=1.182 new1=fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits sigma_overall=0.318 worst_q_ratio=1.054 new2=fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits sigma_overall=0.331 worst_q_ratio=1.026 reference average sigma_overall=0.4115 worst_q_ratio=1.1715 warn-on-ratio threshold: 2.0x reference ###################################
Astrometric residual vector field (catalog-matched stars):
plot_astrometric_residuals_xy.py: wrote wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245_astrometric_residuals.png (4903 matched stars from wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat.astrometric_residuals, image 9576x6388, median residual 0.37 arcsec)
plot_astrometric_residuals_xy.py: wrote wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270_astrometric_residuals.png (4904 matched stars from wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits.wcscat.astrometric_residuals, image 9576x6388, median residual 0.35 arcsec)
plot_astrometric_residuals_xy.py: wrote wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160_astrometric_residuals.png (3658 matched stars from wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits.wcscat.astrometric_residuals, image 9576x6388, median residual 0.28 arcsec)
plot_astrometric_residuals_xy.py: wrote wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161_astrometric_residuals.png (3627 matched stars from wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits.wcscat.astrometric_residuals, image 9576x6388, median residual 0.30 arcsec)
Copying WCS-calibrated images back to input directory Saving fully-calibrated image wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits INFO: FPACK_FULLY_CALIBRATED_IMAGE=no (not compressing the image) 'wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits' -> '/data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits' Saving fully-calibrated image wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits INFO: FPACK_FULLY_CALIBRATED_IMAGE=no (not compressing the image) 'wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits' -> '/data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits' Preparing the HTML report for the field Dra-07-Q1b1x1 with default.sex.telephoto_lens_onlybrightstars_v1 make_report_in_HTML.sh Phase 1 (network queries): 0s Pre-generating preview images in parallel... Done pre-generating preview images. Pre-generating finding charts in parallel... Done pre-generating finding charts. make_report_in_HTML.sh Pre-generation: 1s xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 04197_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 04197_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 3   2026 08 28.26418    2461280.76418    11.10    17:07:12.81 +63:21:22.7   4965 2389   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits **** FOUND 17:07:12.81 +63:21:22.3 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 00315_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 00315_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 3   2026 08 28.26418    2461280.76418    7.56    16:32:40.38 +66:45:16.1   7156 0322   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits **** FOUND 16:32:40.41 +66:45:16.2 in the exclusion list exclusion_list.txt **** make_report_in_HTML.sh Phase 2 (HTML assembly): 0s make_report_in_HTML.sh TOTAL: 1s Prepared the HTML report for the field Dra-07-Q1b1x1 with default.sex.telephoto_lens_onlybrightstars_v1 *------ done with default.sex.telephoto_lens_onlybrightstars_v1 ------* #### The local exclusion list is exclusion_list_local.txt #### wait *------ default.sex.telephoto_lens_vSTL ------* 'default.sex.telephoto_lens_vSTL' -> 'default.sex' Starting VaST with default.sex.telephoto_lens_vSTL ./vast --noflagimage --starmatchraius 5 --matchstarnumber 500 --selectbestaperture --sysrem 0 --type 4 --maxsextractorflag 99 --UTC --nofind --nojdkeyword /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits SExtractor catalog cache: saved Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.cat to cache SExtractor catalog cache: saved Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits.cat to cache VaST run complete with default.sex.telephoto_lens_vSTL The four input images were /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits Checking WCS cache directory local_wcs_cache Found WCS cache directory local_wcs_cache Creating symlink local_wcs_cache/wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits Creating symlink local_wcs_cache/wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits Creating symlink local_wcs_cache/wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits Creating symlink local_wcs_cache/wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits Checking WCS cache directory /mnt/usb/NMW_NG/solved_reference_images Found WCS cache directory /mnt/usb/NMW_NG/solved_reference_images Checking WCS cache directory /home/NMW_web_upload/solved_reference_images Checking WCS cache directory /dataX/kirx/NMW_NG_rt3_autumn2019/solved_reference_images Plate-solving the images wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits exists and is non-empty wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits exists and is non-empty wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits exists and is non-empty wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits exists and is non-empty ################################### # fov_of_wcs_calibrated_image.sh output for wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits (1st reference image) verification OK: wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits Image size: 937.4'x624.3' 15.6(deg)x10.4(deg) 9576x6388 pix Image scale: 5.87"/pix along the X axis and 5.86"/pix along the Y axis Image center: 17:08:33.660 +61:59:46.08 J2000 4789.000 3195.000 ################################### The image scale is 5.87"/pix, setting the soft and hard astrometric limits for filtering second-epoch detections: 5.9" and 8.8" ################################### # fov_of_wcs_calibrated_image.sh output for wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits (1st new image) verification OK: wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits Image size: 941.4'x626.6' 15.7(deg)x10.4(deg) 9576x6388 pix Image scale: 5.90"/pix along the X axis and 5.89"/pix along the Y axis Image center: 17:08:56.501 +61:59:31.28 J2000 4789.000 3195.000 ################################### ################################### # Check the image center offset between the reference and the first second-epoch image (pointing accuracy) Reference image center 17:08:33.660 +61:59:46.08 Second-epoch image center 17:08:56.501 +61:59:31.28 Angular distance between the image centers 0.0449 deg. Soft limit: 0.50 deg. Hard limit: 1.00 deg. ################################### ################################### # fov_of_wcs_calibrated_image.sh output for wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits (2nd new image) verification OK: wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits Image size: 941.4'x626.6' 15.7(deg)x10.4(deg) 9576x6388 pix Image scale: 5.90"/pix along the X axis and 5.89"/pix along the Y axis Image center: 17:08:59.468 +62:00:03.59 J2000 4789.000 3195.000 ################################### ################################### # Check the image center offset between the reference and the second second-epoch image (pointing accuracy) Reference image center 17:08:33.660 +61:59:46.08 Second-epoch image center 17:08:59.468 +62:00:03.59 Angular distance between the image centers 0.0507 deg. ################################### ################################### # Check the image center offset between the first and the second second-epoch image (shift should be applied between the second-epoch images) Second-epoch first image center 17:08:56.501 +61:59:31.28 Second-epoch second image center 17:08:59.468 +62:00:03.59 Angular distance between the image centers 0.01069 deg. ################################### Running solve_plate_with_UCAC5... Preparing for a parallel run Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits &> /tmp/tmp.eA7eMIjCAw Parallel run for /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits &> /tmp/tmp.kKmoJL8Ihx Parallel run for /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits &> /tmp/tmp.VJh4ta0uhg Parallel run for /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits &> /tmp/tmp.lcVoLfKCTg Parallel run for /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits Calibrating the magnitude scale Found non-empty wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits ____ Start of magnitude calibration ____ PHOTOMETRIC_CALIBRATION=TYCHO2_V Calibrating the magnitude scale with Tycho-2 stars util/transients/transient_factory_test31.sh is checking for the presence of non-empty wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits and wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat wait (drain background util/solve_plate_with_UCAC5 jobs before Tycho-2 calibration -- avoids wcs_.fits write race) Tycho-2 catalog is found at lib/catalogs/tycho2 Tycho-2 catalog and the derived bright star exclusion list are ready Checking for the presence of non-empty wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits and wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat Found non-empty wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits and wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat The reference image (wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits) and catalog (wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat) found 'wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat' -> 'wcsmag.cat' Read 63702 stars from the SExtractor catalog wcsmag.cat Detected star coordinate range: RA 237.9201 to 276.7125 deg, Dec +55.8395 to +67.2662 deg Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.00 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.01 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.02 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.03 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.04 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.05 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.06 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.07 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.08 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.09 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.10 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.11 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.12 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.13 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.14 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.15 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.16 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.17 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.18 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.19 Tycho-2 catalog search boundaries: RA 237.9201 to 276.7125 deg, Dec 55.8395 to 67.2662 deg Loaded 9375 Tycho-2 stars within the image boundaries (VT and BT non-zero). Relation between the catalog and instrumental magnitudes is written to calib.txt Stars used for magnitude calibration (good matches): 5541 out of 6359 total matches. Matched with Tycho-2 6359 out of 63702 detected stars. The calibration function type and coefficients are written to calib.txt_param util/calibrate_magnitude_scale 0.000000 1.000000 22.555600 a=0.000000 b=1.000000 c=22.555600 From vast_summary.log: estimated ref. image limiting mag.: -7.11 Updating vast_summary.log: Estimated ref. image limiting mag.: 15.45 Updated vast_limiting_magnitude.log with calibrated magnitudes Working... Please, PLEASE, be patient!!! All lightcurves processed! =) Estimated ref. image limiting mag.: 15.45
Lightcurve magnitude calibration plot:

Preparing per-reference-image forced-photometry calibration (method=tycho2 band=V) Read 63702 stars from the SExtractor catalog wcsmag.cat Detected star coordinate range: RA 237.9201 to 276.7125 deg, Dec +55.8395 to +67.2662 deg Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.00 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.01 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.02 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.03 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.04 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.05 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.06 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.07 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.08 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.09 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.10 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.11 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.12 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.13 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.14 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.15 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.16 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.17 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.18 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.19 Tycho-2 catalog search boundaries: RA 237.9201 to 276.7125 deg, Dec 55.8395 to 67.2662 deg Loaded 9375 Tycho-2 stars within the image boundaries (VT and BT non-zero). Relation between the catalog and instrumental magnitudes is written to calib.txt Stars used for magnitude calibration (good matches): 5541 out of 6359 total matches. Matched with Tycho-2 6359 out of 63702 detected stars. util/calibrate_single_image_with_tycho2.sh: calibrated wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits via Tycho-2
Single-image forced-photometry magnitude calibration plot for wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits:

Forced-photometry filter: reusing the VaST-run aperture from image00001.cat.aperture for wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits Forced-photometry filter: calibrated wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits -> calib.txt_param_ref_wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits (aperture=4.9) Read 64271 stars from the SExtractor catalog wcsmag.cat Detected star coordinate range: RA 237.9600 to 276.7126 deg, Dec +55.8529 to +67.2581 deg Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.00 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.01 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.02 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.03 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.04 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.05 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.06 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.07 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.08 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.09 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.10 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.11 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.12 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.13 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.14 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.15 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.16 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.17 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.18 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.19 Tycho-2 catalog search boundaries: RA 237.9600 to 276.7126 deg, Dec 55.8529 to 67.2581 deg Loaded 9339 Tycho-2 stars within the image boundaries (VT and BT non-zero). Relation between the catalog and instrumental magnitudes is written to calib.txt Stars used for magnitude calibration (good matches): 5522 out of 6355 total matches. Matched with Tycho-2 6355 out of 64271 detected stars. util/calibrate_single_image_with_tycho2.sh: calibrated wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits via Tycho-2
Single-image forced-photometry magnitude calibration plot for wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits:

Forced-photometry filter: reusing the VaST-run aperture from image00002.cat.aperture for wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits Forced-photometry filter: calibrated wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits -> calib.txt_param_ref_wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits (aperture=4.9) ____ End of magnitude calibration ____ Applying consolidated magnitude filters... Preparing the exclusion lists for this field Done with filtering Found 52 candidate transients before the final filtering. (Hard limit: 10000) Median FWHM seeing for isolated stars: 2.1 pix Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits 2.1 pix Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits 2.1 pix fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits 2.1 pix fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits Limiting magnitude estimates: 15.4 mag. Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits 15.4 mag. Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits 14.2 mag. fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits 14.2 mag. fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits All-image limiting magnitude estimate: 14.2 (SNR ) 13.6 (80% of stars) with default.sex.telephoto_lens_vSTL The first estimate is the magnitude of a star detected with a signal-to-noise ratio of following Karpov (2025, Acta Polytechnica, 65, 50). This value should be representative of the faintest stars clearly visible in the image. The brighter of the limiting magnitude estimates for the two second-epoch images is reported here. The second estimate is the 80th percentile of the magnitude distribution of stars detected on all four images. This value is representative of the faintest object that may enter the candidate transients list. The hard cut-off for the candidate transients is 15.5 mag. Waiting for UCAC5 plate solver wait ############ /tmp/tmp.eA7eMIjCAw (6) ############ Parsing command line arguments... WARNING from replace_file_with_symlink_if_filename_contains_white_spaces() the input file /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits is already a symlink and we do not allow symlinks on symlinks The guess is based on the existing WCS header. Trying to blindly solve the plate (local solve-field or remote server)... /data_ssd/NMW-TexasTech/workdir/vast_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits 571.0 Entering WCS image calibration mode. ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits WARNING from replace_file_with_symlink_if_filename_contains_white_spaces() the input file /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits is already a symlink and we do not allow symlinks on symlinks FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits verification OK: /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits It's a known telescope with plate solutions that are supposed to be good. The input image /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits has a WCS header - will blindly trust it is good... '/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits' -> 'wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits' This WCS solution (astrometrynet) will be kept as is, not refit by util/solve_plate_with_UCAC5 FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits WCS_IMAGE_NAME=wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits WCS-calibrated image found: wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits Checking if the catalog wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat corresponding to the image wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits alredy exist and is non-empty... Catalog wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat corresponding to the image wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits found. The catalog is in the new format, as expected. The plate-solved (WCS-calibrated) image is saved to wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits WCS catalog name: wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat Excluding image region: 190.0 1039.0 192.0 1041.0 (defined in bad_region.lst) Excluding image region: 226.0 1548.0 228.0 1550.0 (defined in bad_region.lst) Excluding image region: 351.0 1875.0 353.0 1877.0 (defined in bad_region.lst) Excluding image region: 501.0 5912.0 503.0 5914.0 (defined in bad_region.lst) Excluding image region: 638.0 5545.0 640.0 5547.0 (defined in bad_region.lst) Excluding image region: 724.0 2731.0 726.0 2733.0 (defined in bad_region.lst) Excluding image region: 883.0 1376.0 885.0 1378.0 (defined in bad_region.lst) Excluding image region: 901.0 3972.0 903.0 3974.0 (defined in bad_region.lst) Excluding image region: 1151.0 918.0 1153.0 920.0 (defined in bad_region.lst) Excluding image region: 1157.0 135.0 1159.0 137.0 (defined in bad_region.lst) Excluding more image regions!.. (will not print them all) Excluded a total of 50 image regions (defined in bad_region.lst). SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=37, blended=3836, bad_region=1, passed=63665 Got 63665 stars (including 59741 good ones) from the SExtractor catalog wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat util/solve_plate_with_UCAC5 got 63665 stars from the SExtractor catalog Updated FoV from the plate-solved image: 937.4' Seting catalog search parameters based on the expected field of view 937.4 arcmin UCAC5 catalog search parameters: catalog_search_parameters->search_radius_deg= 0.013019 (46.9 arcsec) catalog_search_parameters->brightest_mag= 1.00 catalog_search_parameters->faintest_mag= 13.50 catalog_search_parameters->search_radius_second_step_deg 0.010416 (37.5 arcsec) ITERATION 01 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50 Reading UCAC5 zone files... Searching UCAC5 zones 729 to 788 (Dec 55.8 to 67.3) Done reading UCAC5 zone files... Matched 4907 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Correcting the measured astrometric positions... Accuracy estimation diagnostic: 4903 matched stars entering correct_measured_positions(), 4903 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.37" Removing outliers... Correcting the measured astrometric positions... Accuracy estimation diagnostic: 4903 matched stars entering correct_measured_positions(), 63665 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.37" ITERATION 02 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50 Reading UCAC5 zone files... Searching UCAC5 zones 729 to 788 (Dec 55.8 to 67.3) Done reading UCAC5 zone files... Matched 4907 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Accuracy estimation diagnostic: 4903 matched stars entering correct_measured_positions(), 63665 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.37" Accuracy estimation diagnostic: 4903 matched stars entering correct_measured_positions(), 63665 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.39" Excluding outliers - 4903 stars left (next iteration limit 5393) Stop iterations. The field is successfully solved and matched with the astrometric catalog! :) SIP_REFIT: wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits is a symbolic link - will not rewrite the WCS of whatever it points to, but will still refit the output catalog positions SIP_REFIT: util/identify.sh trusts the WCS of wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits (astrometrynet) - keeping it, no refit (set VAST_FORCE_SIP_REFIT=1 to refit anyway) WCS_QUALITY_DIAG: file=Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits N_match=4903 sigma_overall_arcsec=0.416 sigma_q1_arcsec=0.359 sigma_q2_arcsec=0.451 sigma_q3_arcsec=0.483 sigma_q4_arcsec=0.395 n_q1=1358 n_q2=1206 n_q3=1167 n_q4=1172 worst_quadrant_to_overall_ratio=1.160 The image catalog is written to wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat.ucac5 The DS9 region file with the matched stars is written to wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat.ds9.reg You may view it with the command: ds9 /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits -region wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat.ds9.reg The astrometric residuals vector field is written to wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat.astrometric_residuals Option '-n' not using photometric catalogs, just stick with astrometry opt '-i': 2 is the maximum number of iterations FORCED_PHOTOMETRY_CALIBRATION_METHOD=tycho2 - not using remote photometric catalogs, just stick with astrometry ############ /tmp/tmp.kKmoJL8Ihx (6) ############ Parsing command line arguments... WARNING from replace_file_with_symlink_if_filename_contains_white_spaces() the input file /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits is already a symlink and we do not allow symlinks on symlinks The guess is based on the existing WCS header. Trying to blindly solve the plate (local solve-field or remote server)... /data_ssd/NMW-TexasTech/workdir/vast_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits 571.0 Entering WCS image calibration mode. ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits WARNING from replace_file_with_symlink_if_filename_contains_white_spaces() the input file /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits is already a symlink and we do not allow symlinks on symlinks FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits verification OK: /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits It's a known telescope with plate solutions that are supposed to be good. The input image /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits has a WCS header - will blindly trust it is good... '/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits' -> 'wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits' This WCS solution (astrometrynet) will be kept as is, not refit by util/solve_plate_with_UCAC5 FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits WCS_IMAGE_NAME=wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits WCS-calibrated image found: wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits Checking if the catalog wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits.wcscat corresponding to the image wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits alredy exist and is non-empty... Catalog wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits.wcscat corresponding to the image wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits found. The catalog is in the new format, as expected. The plate-solved (WCS-calibrated) image is saved to wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits WCS catalog name: wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits.wcscat Excluding image region: 190.0 1039.0 192.0 1041.0 (defined in bad_region.lst) Excluding image region: 226.0 1548.0 228.0 1550.0 (defined in bad_region.lst) Excluding image region: 351.0 1875.0 353.0 1877.0 (defined in bad_region.lst) Excluding image region: 501.0 5912.0 503.0 5914.0 (defined in bad_region.lst) Excluding image region: 638.0 5545.0 640.0 5547.0 (defined in bad_region.lst) Excluding image region: 724.0 2731.0 726.0 2733.0 (defined in bad_region.lst) Excluding image region: 883.0 1376.0 885.0 1378.0 (defined in bad_region.lst) Excluding image region: 901.0 3972.0 903.0 3974.0 (defined in bad_region.lst) Excluding image region: 1151.0 918.0 1153.0 920.0 (defined in bad_region.lst) Excluding image region: 1157.0 135.0 1159.0 137.0 (defined in bad_region.lst) Excluding more image regions!.. (will not print them all) Excluded a total of 50 image regions (defined in bad_region.lst). SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=43, blended=3885, bad_region=0, passed=64228 Got 64228 stars (including 60263 good ones) from the SExtractor catalog wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits.wcscat util/solve_plate_with_UCAC5 got 64228 stars from the SExtractor catalog Updated FoV from the plate-solved image: 937.3' Seting catalog search parameters based on the expected field of view 937.3 arcmin UCAC5 catalog search parameters: catalog_search_parameters->search_radius_deg= 0.013018 (46.9 arcsec) catalog_search_parameters->brightest_mag= 1.00 catalog_search_parameters->faintest_mag= 13.50 catalog_search_parameters->search_radius_second_step_deg 0.010414 (37.5 arcsec) ITERATION 01 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50 Reading UCAC5 zone files... Searching UCAC5 zones 729 to 788 (Dec 55.9 to 67.3) Done reading UCAC5 zone files... Matched 4906 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Correcting the measured astrometric positions... Accuracy estimation diagnostic: 4903 matched stars entering correct_measured_positions(), 4903 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.35" Removing outliers... Correcting the measured astrometric positions... Accuracy estimation diagnostic: 4903 matched stars entering correct_measured_positions(), 64228 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.35" ITERATION 02 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50 Reading UCAC5 zone files... Searching UCAC5 zones 729 to 788 (Dec 55.9 to 67.3) Done reading UCAC5 zone files... Matched 4906 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Accuracy estimation diagnostic: 4903 matched stars entering correct_measured_positions(), 64228 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.35" Accuracy estimation diagnostic: 4903 matched stars entering correct_measured_positions(), 64228 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.37" Excluding outliers - 4903 stars left (next iteration limit 5393) Stop iterations. The field is successfully solved and matched with the astrometric catalog! :) SIP_REFIT: wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits is a symbolic link - will not rewrite the WCS of whatever it points to, but will still refit the output catalog positions SIP_REFIT: util/identify.sh trusts the WCS of wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits (astrometrynet) - keeping it, no refit (set VAST_FORCE_SIP_REFIT=1 to refit anyway) WCS_QUALITY_DIAG: file=Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits N_match=4903 sigma_overall_arcsec=0.391 sigma_q1_arcsec=0.338 sigma_q2_arcsec=0.424 sigma_q3_arcsec=0.476 sigma_q4_arcsec=0.359 n_q1=1359 n_q2=1221 n_q3=1158 n_q4=1165 worst_quadrant_to_overall_ratio=1.216 The image catalog is written to wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits.wcscat.ucac5 The DS9 region file with the matched stars is written to wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits.wcscat.ds9.reg You may view it with the command: ds9 /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits -region wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits.wcscat.ds9.reg The astrometric residuals vector field is written to wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits.wcscat.astrometric_residuals Option '-n' not using photometric catalogs, just stick with astrometry opt '-i': 2 is the maximum number of iterations FORCED_PHOTOMETRY_CALIBRATION_METHOD=tycho2 - not using remote photometric catalogs, just stick with astrometry ############ /tmp/tmp.VJh4ta0uhg (6) ############ Parsing command line arguments... The minor axis of the CCD chip should be 24.0 mm based on the derived pixel size of 3.8 um Internal estimated FoV 605.3' The guess is based on the FOCALLEN keyword. Trying to blindly solve the plate (local solve-field or remote server)... /data_ssd/NMW-TexasTech/workdir/vast_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits 605.0 Entering WCS image calibration mode. ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits verification OK: /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits It's not one of the telescopes that are know to produce images with good WCS solutions - will try to re-solve! FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits WCS_IMAGE_NAME=wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits WCS-calibrated image found: wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits Checking if the catalog wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits.wcscat corresponding to the image wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits alredy exist and is non-empty... Catalog wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits.wcscat corresponding to the image wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits found. The catalog is in the new format, as expected. The plate-solved (WCS-calibrated) image is saved to wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits WCS catalog name: wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits.wcscat Excluding image region: 190.0 1039.0 192.0 1041.0 (defined in bad_region.lst) Excluding image region: 226.0 1548.0 228.0 1550.0 (defined in bad_region.lst) Excluding image region: 351.0 1875.0 353.0 1877.0 (defined in bad_region.lst) Excluding image region: 501.0 5912.0 503.0 5914.0 (defined in bad_region.lst) Excluding image region: 638.0 5545.0 640.0 5547.0 (defined in bad_region.lst) Excluding image region: 724.0 2731.0 726.0 2733.0 (defined in bad_region.lst) Excluding image region: 883.0 1376.0 885.0 1378.0 (defined in bad_region.lst) Excluding image region: 901.0 3972.0 903.0 3974.0 (defined in bad_region.lst) Excluding image region: 1151.0 918.0 1153.0 920.0 (defined in bad_region.lst) Excluding image region: 1157.0 135.0 1159.0 137.0 (defined in bad_region.lst) Excluding more image regions!.. (will not print them all) Excluded a total of 50 image regions (defined in bad_region.lst). SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=6, blended=878, bad_region=0, passed=28684 Got 28684 stars (including 27771 good ones) from the SExtractor catalog wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits.wcscat util/solve_plate_with_UCAC5 got 28684 stars from the SExtractor catalog Updated FoV from the plate-solved image: 941.4' Seting catalog search parameters based on the expected field of view 941.4 arcmin UCAC5 catalog search parameters: catalog_search_parameters->search_radius_deg= 0.013075 (47.1 arcsec) catalog_search_parameters->brightest_mag= 1.00 catalog_search_parameters->faintest_mag= 13.50 catalog_search_parameters->search_radius_second_step_deg 0.010460 (37.7 arcsec) ITERATION 01 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50 Reading UCAC5 zone files... Searching UCAC5 zones 727 to 788 (Dec 55.5 to 67.3) Done reading UCAC5 zone files... Matched 4905 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Correcting the measured astrometric positions... Accuracy estimation diagnostic: 4896 matched stars entering correct_measured_positions(), 4896 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.30" Removing outliers... Correcting the measured astrometric positions... Accuracy estimation diagnostic: 4896 matched stars entering correct_measured_positions(), 28684 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.30" ITERATION 02 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50 Reading UCAC5 zone files... Searching UCAC5 zones 727 to 788 (Dec 55.5 to 67.3) Done reading UCAC5 zone files... Matched 4905 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Accuracy estimation diagnostic: 4896 matched stars entering correct_measured_positions(), 28684 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.30" Accuracy estimation diagnostic: 4896 matched stars entering correct_measured_positions(), 28684 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.31" Excluding outliers - 4896 stars left (next iteration limit 5385) Stop iterations. The field is successfully solved and matched with the astrometric catalog! :) SIP_REFIT: wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits is a symbolic link - will not rewrite the WCS of whatever it points to, but will still refit the output catalog positions SIP_REFIT: SIP order 2 trial: matched=4896 robust_rms=9.366 arcsec worst_quadrant_rms=15.331 arcsec SIP_REFIT: SIP order 3 trial: matched=4896 robust_rms=0.423 arcsec worst_quadrant_rms=0.465 arcsec SIP_REFIT: SIP order 5 trial: matched=4896 robust_rms=0.310 arcsec worst_quadrant_rms=0.316 arcsec SIP_REFIT: selected SIP order 5 SIP_REFIT: order=5 matched=4896 robust_rms_before=0.671 arcsec robust_rms_before_corrected=0.315 arcsec robust_rms_after=0.310 arcsec worst_quadrant_rms_before=0.327 worst_quadrant_rms_after=0.316 SIP_REFIT: refit does not sufficiently improve on the solution it would replace (best worst-quadrant baseline 0.327 arcsec) - keeping the original WCS_QUALITY_DIAG: file=fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits N_match=4896 sigma_overall_arcsec=0.320 sigma_q1_arcsec=0.327 sigma_q2_arcsec=0.325 sigma_q3_arcsec=0.336 sigma_q4_arcsec=0.283 n_q1=1453 n_q2=1053 n_q3=1326 n_q4=1064 worst_quadrant_to_overall_ratio=1.050 The image catalog is written to wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits.wcscat.ucac5 The DS9 region file with the matched stars is written to wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits.wcscat.ds9.reg You may view it with the command: ds9 /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits -region wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits.wcscat.ds9.reg The astrometric residuals vector field is written to wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits.wcscat.astrometric_residuals Option '-n' not using photometric catalogs, just stick with astrometry opt '-i': 2 is the maximum number of iterations FORCED_PHOTOMETRY_CALIBRATION_METHOD=tycho2 - not using remote photometric catalogs, just stick with astrometry ############ /tmp/tmp.lcVoLfKCTg (6) ############ Parsing command line arguments... The minor axis of the CCD chip should be 24.0 mm based on the derived pixel size of 3.8 um Internal estimated FoV 605.3' The guess is based on the FOCALLEN keyword. Trying to blindly solve the plate (local solve-field or remote server)... /data_ssd/NMW-TexasTech/workdir/vast_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits 605.0 Entering WCS image calibration mode. ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits verification OK: /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits It's not one of the telescopes that are know to produce images with good WCS solutions - will try to re-solve! FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits WCS_IMAGE_NAME=wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits WCS-calibrated image found: wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits Checking if the catalog wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits.wcscat corresponding to the image wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits alredy exist and is non-empty... Catalog wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits.wcscat corresponding to the image wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits found. The catalog is in the new format, as expected. The plate-solved (WCS-calibrated) image is saved to wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits WCS catalog name: wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits.wcscat Excluding image region: 190.0 1039.0 192.0 1041.0 (defined in bad_region.lst) Excluding image region: 226.0 1548.0 228.0 1550.0 (defined in bad_region.lst) Excluding image region: 351.0 1875.0 353.0 1877.0 (defined in bad_region.lst) Excluding image region: 501.0 5912.0 503.0 5914.0 (defined in bad_region.lst) Excluding image region: 638.0 5545.0 640.0 5547.0 (defined in bad_region.lst) Excluding image region: 724.0 2731.0 726.0 2733.0 (defined in bad_region.lst) Excluding image region: 883.0 1376.0 885.0 1378.0 (defined in bad_region.lst) Excluding image region: 901.0 3972.0 903.0 3974.0 (defined in bad_region.lst) Excluding image region: 1151.0 918.0 1153.0 920.0 (defined in bad_region.lst) Excluding image region: 1157.0 135.0 1159.0 137.0 (defined in bad_region.lst) Excluding more image regions!.. (will not print them all) Excluded a total of 50 image regions (defined in bad_region.lst). SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=1, no_mag_err=0, low_SNR=5, blended=860, bad_region=0, passed=28576 Got 28576 stars (including 27678 good ones) from the SExtractor catalog wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits.wcscat util/solve_plate_with_UCAC5 got 28576 stars from the SExtractor catalog Updated FoV from the plate-solved image: 941.4' Seting catalog search parameters based on the expected field of view 941.4 arcmin UCAC5 catalog search parameters: catalog_search_parameters->search_radius_deg= 0.013075 (47.1 arcsec) catalog_search_parameters->brightest_mag= 1.00 catalog_search_parameters->faintest_mag= 13.50 catalog_search_parameters->search_radius_second_step_deg 0.010460 (37.7 arcsec) ITERATION 01 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50 Reading UCAC5 zone files... Searching UCAC5 zones 727 to 788 (Dec 55.5 to 67.4) Done reading UCAC5 zone files... Matched 4902 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Correcting the measured astrometric positions... Accuracy estimation diagnostic: 4893 matched stars entering correct_measured_positions(), 4893 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.30" Removing outliers... Correcting the measured astrometric positions... Accuracy estimation diagnostic: 4893 matched stars entering correct_measured_positions(), 28576 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.30" ITERATION 02 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 UCAC5 local query limit 5000: matching up to 5000 detected stars, deepening the UCAC5 window to mag 15.50 Reading UCAC5 zone files... Searching UCAC5 zones 727 to 788 (Dec 55.5 to 67.4) Done reading UCAC5 zone files... Matched 4902 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Accuracy estimation diagnostic: 4893 matched stars entering correct_measured_positions(), 28576 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.30" Accuracy estimation diagnostic: 4893 matched stars entering correct_measured_positions(), 28576 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.30" Excluding outliers - 4893 stars left (next iteration limit 5382) Stop iterations. The field is successfully solved and matched with the astrometric catalog! :) SIP_REFIT: wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits is a symbolic link - will not rewrite the WCS of whatever it points to, but will still refit the output catalog positions SIP_REFIT: SIP order 2 trial: matched=4893 robust_rms=9.395 arcsec worst_quadrant_rms=14.922 arcsec SIP_REFIT: SIP order 3 trial: matched=4893 robust_rms=0.421 arcsec worst_quadrant_rms=0.444 arcsec SIP_REFIT: SIP order 5 trial: matched=4893 robust_rms=0.309 arcsec worst_quadrant_rms=0.327 arcsec SIP_REFIT: selected SIP order 5 SIP_REFIT: order=5 matched=4893 robust_rms_before=0.650 arcsec robust_rms_before_corrected=0.319 arcsec robust_rms_after=0.309 arcsec worst_quadrant_rms_before=0.334 worst_quadrant_rms_after=0.327 SIP_REFIT: refit does not sufficiently improve on the solution it would replace (best worst-quadrant baseline 0.334 arcsec) - keeping the original WCS_QUALITY_DIAG: file=fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits N_match=4893 sigma_overall_arcsec=0.326 sigma_q1_arcsec=0.331 sigma_q2_arcsec=0.341 sigma_q3_arcsec=0.320 sigma_q4_arcsec=0.307 n_q1=1464 n_q2=1043 n_q3=1317 n_q4=1069 worst_quadrant_to_overall_ratio=1.046 The image catalog is written to wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits.wcscat.ucac5 The DS9 region file with the matched stars is written to wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits.wcscat.ds9.reg You may view it with the command: ds9 /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits -region wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits.wcscat.ds9.reg The astrometric residuals vector field is written to wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits.wcscat.astrometric_residuals Option '-n' not using photometric catalogs, just stick with astrometry opt '-i': 2 is the maximum number of iterations FORCED_PHOTOMETRY_CALIBRATION_METHOD=tycho2 - not using remote photometric catalogs, just stick with astrometry Skipping WCS quality comparison: not the first SExtractor pass (default.sex.telephoto_lens_vSTL) Copying WCS-calibrated images back to input directory Saving fully-calibrated image wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits INFO: FPACK_FULLY_CALIBRATED_IMAGE=no (not compressing the image) The destination file is already there - not rewriting /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits Saving fully-calibrated image wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits INFO: FPACK_FULLY_CALIBRATED_IMAGE=no (not compressing the image) The destination file is already there - not rewriting /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits Preparing the HTML report for the field Dra-07-Q1b1x1 with default.sex.telephoto_lens_vSTL Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 16:04:38.02 +61:09:46.6: 12.75 +/- 0.02 detection Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:46:15.29 +61:20:17.7: 13.62 +/- 0.04 detection Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:23:48.85 +58:43:36.5: 13.70 +/- 0.04 detection Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:34:22.97 +60:34:39.1: 12.95 +/- 0.02 detection Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 18:03:11.24 +59:52:47.1: 12.20 +/- 0.01 detection Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:23:02.06 +60:25:53.5: 12.76 +/- 0.02 detection Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 16:10:20.13 +65:10:27.6: 12.59 +/- 0.02 detection Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:32:48.27 +65:31:09.6: 13.60 +/- 0.04 detection Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 16:08:19.30 +58:32:53.8: 11.54 +/- 0.01 detection Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 18:03:26.28 +56:56:13.2: 11.55 +/- 0.01 detection Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 16:10:20.13 +65:10:27.6: 12.63 +/- 0.02 detection Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:34:22.97 +60:34:39.1: 13.02 +/- 0.02 detection Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 16:04:38.02 +61:09:46.6: 12.74 +/- 0.02 detection Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 18:03:11.24 +59:52:47.1: 12.26 +/- 0.01 detection Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:46:15.29 +61:20:17.7: 13.63 +/- 0.04 detection Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:32:48.27 +65:31:09.6: 13.57 +/- 0.04 detection Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:23:02.06 +60:25:53.5: 12.68 +/- 0.02 detection Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:23:48.85 +58:43:36.5: 13.62 +/- 0.04 detection Forced photometry reference-image weighted average: 12.61 +/- 0.01 Forced photometry reference-image weighted average: 12.98 +/- 0.01 Forced photometry filter REJECTED candidate at 16:10:20.13 +65:10:27.6: ref_mag=12.61 +/- 0.01 new_mean_mag=12.7753 delta=-0.17 (need > 0.90) Forced photometry reference-image weighted average: 12.23 +/- 0.01 Forced photometry reference-image weighted average: 12.75 +/- 0.02 Forced photometry reference-image weighted average: 13.62 +/- 0.03 Forced photometry reference-image weighted average: 13.59 +/- 0.03 Forced photometry reference-image weighted average: 12.72 +/- 0.01 Forced photometry reference-image weighted average: 13.66 +/- 0.03 Forced photometry filter REJECTED candidate at 17:34:22.97 +60:34:39.1: ref_mag=12.98 +/- 0.01 new_mean_mag=13.4676 delta=-0.49 (need > 0.90) Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 16:08:19.30 +58:32:53.8: 11.54 +/- 0.01 detection Forced photometry filter REJECTED candidate at 17:46:15.29 +61:20:17.7: ref_mag=13.62 +/- 0.03 new_mean_mag=13.6786 delta=-0.06 (need > 0.90) Forced photometry filter REJECTED candidate at 17:23:48.85 +58:43:36.5: ref_mag=13.66 +/- 0.03 new_mean_mag=13.7464 delta=-0.09 (need > 0.90) Forced photometry filter REJECTED candidate at 17:23:02.06 +60:25:53.5: ref_mag=12.72 +/- 0.01 new_mean_mag=13.2807 delta=-0.56 (need > 0.90) Forced photometry filter REJECTED candidate at 16:04:38.02 +61:09:46.6: ref_mag=12.75 +/- 0.02 new_mean_mag=12.9258 delta=-0.18 (need > 0.90) Forced photometry filter REJECTED candidate at 17:32:48.27 +65:31:09.6: ref_mag=13.59 +/- 0.03 new_mean_mag=13.9746 delta=-0.39 (need > 0.90) Forced photometry filter REJECTED candidate at 18:03:11.24 +59:52:47.1: ref_mag=12.23 +/- 0.01 new_mean_mag=12.6300 delta=-0.40 (need > 0.90) Forced photometry reference-image weighted average: 11.54 +/- 0.01 Forced photometry filter REJECTED candidate at 16:08:19.30 +58:32:53.8: ref_mag=11.54 +/- 0.01 new_mean_mag=11.6424 delta=-0.10 (need > 0.90) Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 18:03:26.28 +56:56:13.2: 11.52 +/- 0.01 detection Forced photometry reference-image weighted average: 11.54 +/- 0.01 Forced photometry filter REJECTED candidate at 18:03:26.28 +56:56:13.2: ref_mag=11.54 +/- 0.01 new_mean_mag=11.8186 delta=-0.28 (need > 0.90) Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:48:02.97 +59:30:22.2: 12.22 +/- 0.01 detection Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:17:25.45 +57:24:53.1: 12.55 +/- 0.02 detection Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:43:09.19 +60:46:55.5: 12.94 +/- 0.02 detection Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:48:02.97 +59:30:22.2: 12.26 +/- 0.01 detection Forced photometry reference-image weighted average: 12.24 +/- 0.01 Forced photometry filter REJECTED candidate at 17:48:02.97 +59:30:22.2: ref_mag=12.24 +/- 0.01 new_mean_mag=12.6499 delta=-0.41 (need > 0.90) Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:17:25.45 +57:24:53.1: 12.57 +/- 0.02 detection Forced photometry reference-image weighted average: 12.56 +/- 0.01 Forced photometry filter REJECTED candidate at 17:17:25.45 +57:24:53.1: ref_mag=12.56 +/- 0.01 new_mean_mag=12.6465 delta=-0.08 (need > 0.90) Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:32:55.16 +59:48:12.9: 13.29 +/- 0.04 detection Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:18:40.61 +62:33:07.3: 12.98 +/- 0.02 detection Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:59:31.18 +61:37:05.3: 12.97 +/- 0.02 detection Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:55:59.50 +62:32:44.5: 13.14 +/- 0.03 detection Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:42:46.09 +58:40:03.1: 13.38 +/- 0.04 detection Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:43:09.19 +60:46:55.5: 12.92 +/- 0.02 detection Forced photometry reference-image weighted average: 12.93 +/- 0.01 Forced photometry filter REJECTED candidate at 17:43:09.19 +60:46:55.5: ref_mag=12.93 +/- 0.01 new_mean_mag=13.0572 delta=-0.13 (need > 0.90) Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:32:55.16 +59:48:12.9: 13.25 +/- 0.03 detection Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:18:40.61 +62:33:07.3: 12.94 +/- 0.02 detection Forced photometry reference-image weighted average: 13.27 +/- 0.02 Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:59:31.18 +61:37:05.3: 12.90 +/- 0.02 detection Forced photometry filter REJECTED candidate at 17:32:55.16 +59:48:12.9: ref_mag=13.27 +/- 0.02 new_mean_mag=13.2041 delta=0.07 (need > 0.90) Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:55:59.50 +62:32:44.5: 13.20 +/- 0.03 detection Forced photometry reference-image weighted average: 12.93 +/- 0.02 Forced photometry reference-image weighted average: 12.96 +/- 0.02 Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:05:33.14 +58:43:09.5: 13.33 +/- 0.03 detection Forced photometry filter REJECTED candidate at 17:59:31.18 +61:37:05.3: ref_mag=12.93 +/- 0.02 new_mean_mag=13.1778 delta=-0.24 (need > 0.90) Forced photometry filter REJECTED candidate at 17:18:40.61 +62:33:07.3: ref_mag=12.96 +/- 0.02 new_mean_mag=13.1640 delta=-0.21 (need > 0.90) Forced photometry reference-image weighted average: 13.17 +/- 0.02 Forced photometry filter REJECTED candidate at 17:55:59.50 +62:32:44.5: ref_mag=13.17 +/- 0.02 new_mean_mag=13.2484 delta=-0.08 (need > 0.90) Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:42:46.09 +58:40:03.1: 13.35 +/- 0.03 detection Forced photometry reference-image weighted average: 13.36 +/- 0.03 Forced photometry filter REJECTED candidate at 17:42:46.09 +58:40:03.1: ref_mag=13.36 +/- 0.03 new_mean_mag=13.3322 delta=0.03 (need > 0.90) Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:44:52.31 +60:19:56.5: 13.39 +/- 0.04 detection Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:46:47.52 +59:14:52.3: 13.32 +/- 0.04 detection Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:05:33.14 +58:43:09.5: 13.27 +/- 0.03 detection Forced photometry reference-image weighted average: 13.30 +/- 0.02 Forced photometry filter REJECTED candidate at 17:05:33.14 +58:43:09.5: ref_mag=13.30 +/- 0.02 new_mean_mag=13.3175 delta=-0.02 (need > 0.90) Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:44:52.31 +60:19:56.5: 13.35 +/- 0.03 detection Forced photometry reference-image weighted average: 13.37 +/- 0.03 Forced photometry filter REJECTED candidate at 17:44:52.31 +60:19:56.5: ref_mag=13.37 +/- 0.03 new_mean_mag=13.3249 delta=0.04 (need > 0.90) Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:46:47.52 +59:14:52.3: 13.36 +/- 0.04 detection Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:25:09.33 +64:05:04.1: 13.58 +/- 0.04 detection Forced photometry reference-image weighted average: 13.34 +/- 0.03 Forced photometry filter REJECTED candidate at 17:46:47.52 +59:14:52.3: ref_mag=13.34 +/- 0.03 new_mean_mag=13.5605 delta=-0.23 (need > 0.90) Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:08:13.26 +61:23:04.7: 13.33 +/- 0.03 detection Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:28:21.32 +59:12:43.1: 13.47 +/- 0.03 detection Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits at 17:42:33.24 +62:37:27.6: 13.76 +/- 0.04 detection Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:25:09.33 +64:05:04.1: 13.47 +/- 0.03 detection Forced photometry reference-image weighted average: 13.51 +/- 0.02 Forced photometry filter REJECTED candidate at 17:25:09.33 +64:05:04.1: ref_mag=13.51 +/- 0.02 new_mean_mag=13.6265 delta=-0.11 (need > 0.90) Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:08:13.26 +61:23:04.7: 13.37 +/- 0.03 detection Forced photometry reference-image weighted average: 13.35 +/- 0.02 Forced photometry filter REJECTED candidate at 17:08:13.26 +61:23:04.7: ref_mag=13.35 +/- 0.02 new_mean_mag=13.5559 delta=-0.20 (need > 0.90) Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:28:21.32 +59:12:43.1: 13.46 +/- 0.03 detection Forced photometry reference-image weighted average: 13.47 +/- 0.02 Forced photometry filter REJECTED candidate at 17:28:21.32 +59:12:43.1: ref_mag=13.47 +/- 0.02 new_mean_mag=13.7315 delta=-0.26 (need > 0.90) Forced photometry on wcs_Dra-07-Q1b1x1_2026-06-21_02-15-47_20.00sec_5.00C_LIGHT_0270.fits at 17:42:33.24 +62:37:27.6: 13.78 +/- 0.05 detection Forced photometry reference-image weighted average: 13.77 +/- 0.03 Forced photometry filter REJECTED candidate at 17:42:33.24 +62:37:27.6: ref_mag=13.77 +/- 0.03 new_mean_mag=13.9892 delta=-0.22 (need > 0.90) make_report_in_HTML.sh Phase 1 (network queries): 4s Pre-generating preview images in parallel... Done pre-generating preview images. Pre-generating finding charts in parallel... Done pre-generating finding charts. make_report_in_HTML.sh Pre-generation: 0s xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79091_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79091_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 1   2026 08 28.26356    2461280.76356    14.02    17:32:48.38 +65:31:10.5   3455 0899   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits Discovery image 2   2026 08 28.26418    2461280.76418    13.94    17:32:48.17 +65:31:08.8   3458 0905   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79093_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79093_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 1   2026 08 28.26356    2461280.76356    13.96    17:46:15.25 +61:20:17.8   2092 3209   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits Discovery image 2   2026 08 28.26418    2461280.76418    13.58    17:46:15.34 +61:20:17.6   2095 3215   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79094_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79094_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 1   2026 08 28.26356    2461280.76356    13.77    17:23:48.92 +58:43:36.7   3494 5046   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits Discovery image 2   2026 08 28.26418    2461280.76418    13.73    17:23:48.78 +58:43:36.4   3498 5052   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79096_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79096_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 2   2026 08 28.26418    2461280.76418    13.87    18:13:31.51 +65:17:58.4   0922 0405   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits **** FOUND 18:13:31.61 +65:18:00.6 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79101_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79101_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 1   2026 08 28.26356    2461280.76356    13.51    17:34:22.93 +60:34:38.9   2861 3824   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits Discovery image 2   2026 08 28.26418    2461280.76418    13.44    17:34:23.01 +60:34:39.3   2864 3830   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79103_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79103_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 1   2026 08 28.26356    2461280.76356    13.30    17:23:02.05 +60:25:53.1   3682 4032   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits Discovery image 2   2026 08 28.26418    2461280.76418    13.27    17:23:02.06 +60:25:53.8   3685 4038   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79105_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79105_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 1   2026 08 28.26356    2461280.76356    12.93    16:04:37.81 +61:09:46.3   9441 3442   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits Discovery image 2   2026 08 28.26418    2461280.76418    12.93    16:04:38.23 +61:09:46.8   9444 3446   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79106_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79106_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 1   2026 08 28.26356    2461280.76356    12.80    16:10:20.03 +65:10:27.5   8642 1103   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits Discovery image 2   2026 08 28.26418    2461280.76418    12.76    16:10:20.23 +65:10:27.7   8644 1108   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79110_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79110_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 2   2026 08 28.26418    2461280.76418    13.01    18:04:49.03 +59:39:56.1   0491 3860   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits **** FOUND 18:04:48.98 +59:39:56.1 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79117_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79117_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 1   2026 08 28.26356    2461280.76356    12.64    18:03:11.29 +59:52:47.0   0646 3762   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits Discovery image 2   2026 08 28.26418    2461280.76418    12.62    18:03:11.19 +59:52:47.1   0649 3769   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79120_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79120_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 1   2026 08 28.26356    2461280.76356    11.64    16:08:19.27 +58:32:53.9   9436 5061   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits Discovery image 2   2026 08 28.26418    2461280.76418    11.65    16:08:19.32 +58:32:53.8   9440 5066   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79121_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79121_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 2   2026 08 28.26418    2461280.76418    11.90    17:42:51.20 +56:26:29.2   1742 6179   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits **** FOUND 17:42:51.20 +56:26:29.3 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79260_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79260_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 1   2026 08 28.26356    2461280.76356    11.74    18:03:26.28 +56:56:13.6   0125 5485   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits Discovery image 2   2026 08 28.26418    2461280.76418    11.93    18:03:26.29 +56:56:12.7   0129 5492   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79288_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79288_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 2   2026 08 28.26418    2461280.76418    11.63    18:04:54.90 +65:22:17.2   1462 0531   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits **** FOUND 18:04:54.76 +65:22:16.7 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79361_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79361_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 2   2026 08 28.26418    2461280.76418    12.45    17:56:14.18 +58:13:24.7   0912 4881   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits **** FOUND 17:56:14.14 +58:13:24.8 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79372_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79372_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 2   2026 08 28.26418    2461280.76418    12.45    17:55:09.69 +58:44:24.9   1073 4597   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits **** FOUND 17:55:09.66 +58:44:24.8 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79390_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79390_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 2   2026 08 28.26418    2461280.76418    12.59    17:26:15.66 +58:40:22.7   3303 5059   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits **** FOUND 17:26:15.65 +58:40:22.4 in the exclusion list exclusion_list_bsc.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79403_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79403_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 2   2026 08 28.26418    2461280.76418    12.56    17:26:16.24 +58:38:39.2   3300 5076   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits **** FOUND 17:26:16.22 +58:38:39.5 in the exclusion list exclusion_list_bsc.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79418_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79418_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 2   2026 08 28.26418    2461280.76418    12.66    17:34:43.49 +61:51:55.1   2970 3060   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits **** FOUND 17:34:43.51 +61:51:55.1 in the exclusion list exclusion_list_bsc.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79419_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79419_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 1   2026 08 28.26356    2461280.76356    12.67    17:48:02.93 +59:30:22.2   1721 4263   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits Discovery image 2   2026 08 28.26418    2461280.76418    12.63    17:48:03.00 +59:30:22.2   1724 4270   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79428_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79428_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 2   2026 08 28.26418    2461280.76418    12.75    18:00:16.83 +57:20:19.1   0451 5323   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits **** FOUND 18:00:16.80 +57:20:18.8 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79431_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79431_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 1   2026 08 28.26356    2461280.76356    12.64    17:17:25.42 +57:24:53.5   3910 5893   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits Discovery image 2   2026 08 28.26418    2461280.76418    12.65    17:17:25.49 +57:24:52.7   3914 5899   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79445_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79445_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 2   2026 08 28.26418    2461280.76418    12.73    18:07:23.28 +61:13:09.2   0576 2899   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits **** FOUND 18:07:23.30 +61:13:09.0 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79465_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79465_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 2   2026 08 28.26418    2461280.76418    12.91    17:25:55.08 +60:26:55.3   3474 4000   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits **** FOUND 17:25:55.04 +60:26:55.1 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79473_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79473_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 2   2026 08 28.26418    2461280.76418    12.65    17:08:25.98 +65:44:20.1   4980 0949   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits **** FOUND 17:08:26.00 +65:44:20.5 in the exclusion list exclusion_list_bbsc.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79484_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79484_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 2   2026 08 28.26418    2461280.76418    12.85    17:59:06.08 +63:58:37.8   1599 1452   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits **** FOUND 17:59:06.07 +63:58:37.7 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79492_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79492_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 2   2026 08 28.26418    2461280.76418    12.93    17:22:11.75 +56:44:42.9   3479 6262   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits **** FOUND 17:22:11.76 +56:44:42.1 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79510_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79510_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 2   2026 08 28.26418    2461280.76418    13.07    18:01:17.21 +56:59:37.1   0313 5505   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits **** FOUND 18:01:17.21 +56:59:36.9 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79511_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79511_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 1   2026 08 28.26356    2461280.76356    12.99    17:43:09.16 +60:46:55.4   2245 3584   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits Discovery image 2   2026 08 28.26418    2461280.76418    13.15    17:43:09.23 +60:46:55.6   2248 3591   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79546_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79546_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 2   2026 08 28.26418    2461280.76418    13.17    18:13:59.71 +64:45:09.2   0789 0712   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits **** FOUND 18:13:59.70 +64:45:09.0 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79582_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79582_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 1   2026 08 28.26356    2461280.76356    13.18    17:32:55.16 +59:48:13.0   2893 4302   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits Discovery image 2   2026 08 28.26418    2461280.76418    13.23    17:32:55.16 +59:48:12.7   2896 4308   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79583_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79583_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 2   2026 08 28.26418    2461280.76418    13.15    17:08:35.33 +65:41:13.9   4968 0980   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits **** FOUND 17:08:35.37 +65:41:13.6 in the exclusion list exclusion_list_bbsc.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79596_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79596_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 1   2026 08 28.26356    2461280.76356    13.26    17:59:31.11 +61:37:05.7   1195 2818   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits Discovery image 2   2026 08 28.26418    2461280.76418    13.12    17:59:31.25 +61:37:04.9   1198 2825   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79599_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79599_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 1   2026 08 28.26356    2461280.76356    13.25    17:55:59.47 +62:32:44.8   1582 2339   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits Discovery image 2   2026 08 28.26418    2461280.76418    13.24    17:55:59.53 +62:32:44.2   1585 2345   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79622_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79622_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 1   2026 08 28.26356    2461280.76356    13.16    17:18:40.64 +62:33:06.9   4140 2799   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits Discovery image 2   2026 08 28.26418    2461280.76418    13.17    17:18:40.57 +62:33:07.6   4143 2805   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79640_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79640_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 2   2026 08 28.26418    2461280.76418    13.21    16:48:42.60 +59:31:15.2   6234 4734   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits **** FOUND 16:48:42.59 +59:31:15.3 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79644_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79644_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 1   2026 08 28.26356    2461280.76356    13.37    17:42:46.07 +58:40:03.3   2017 4845   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits Discovery image 2   2026 08 28.26418    2461280.76418    13.30    17:42:46.11 +58:40:02.9   2021 4851   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79650_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79650_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 2   2026 08 28.26418    2461280.76418    13.49    17:58:58.89 +64:07:58.3   1631 1363   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits **** FOUND 17:58:58.82 +64:07:57.5 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79659_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79659_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 1   2026 08 28.26356    2461280.76356    13.24    17:05:33.06 +58:43:09.6   4917 5180   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits Discovery image 2   2026 08 28.26418    2461280.76418    13.42    17:05:33.22 +58:43:09.5   4920 5185   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79666_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79666_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 1   2026 08 28.26356    2461280.76356    13.40    17:44:52.30 +60:19:57.0   2064 3825   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits Discovery image 2   2026 08 28.26418    2461280.76418    13.27    17:44:52.33 +60:19:56.0   2067 3831   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79702_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79702_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 1   2026 08 28.26356    2461280.76356    13.54    17:46:47.54 +59:14:52.0   1782 4437   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits Discovery image 2   2026 08 28.26418    2461280.76418    13.59    17:46:47.50 +59:14:52.5   1785 4443   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79745_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79745_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 2   2026 08 28.26418    2461280.76418    13.72    18:08:04.12 +59:02:32.4   0137 4152   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits **** FOUND 18:08:03.98 +59:02:31.6 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79752_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79752_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 2   2026 08 28.26418    2461280.76418    13.51    17:31:27.97 +64:29:50.8   3445 1529   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits **** FOUND 17:31:28.02 +64:29:50.4 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79783_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79783_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 1   2026 08 28.26356    2461280.76356    13.58    17:25:09.50 +64:05:04.2   3815 1830   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits Discovery image 2   2026 08 28.26418    2461280.76418    13.69    17:25:09.16 +64:05:04.0   3818 1836   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79807_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79807_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 1   2026 08 28.26356    2461280.76356    13.71    17:28:21.32 +59:12:44.1   3184 4708   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits Discovery image 2   2026 08 28.26418    2461280.76418    13.76    17:28:21.32 +59:12:42.1   3187 4714   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79812_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79812_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 1   2026 08 28.26356    2461280.76356    13.58    17:08:13.21 +61:23:04.6   4816 3563   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits Discovery image 2   2026 08 28.26418    2461280.76418    13.53    17:08:13.31 +61:23:04.9   4819 3569   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79858_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79858_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 2   2026 08 28.26418    2461280.76418    13.65    16:52:14.86 +61:41:06.8   5970 3429   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits **** FOUND 16:52:14.84 +61:41:07.7 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79874_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79874_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 2   2026 08 28.26418    2461280.76418    13.74    16:47:40.39 +56:58:04.7   6335 6282   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits **** FOUND 16:47:40.36 +56:58:04.0 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79885_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79885_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 2   2026 08 28.26418    2461280.76418    13.73    17:35:21.38 +64:21:47.3   3182 1567   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits **** FOUND 17:35:21.50 +64:21:46.4 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79893_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 79893_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 1   2026 08 28.26356    2461280.76356    13.99    17:42:33.29 +62:37:27.1   2508 2503   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits Discovery image 2   2026 08 28.26418    2461280.76418    13.99    17:42:33.19 +62:37:28.2   2512 2509   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 23831_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 23831_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 3   2026 08 28.26418    2461280.76418    11.11    17:07:12.81 +63:21:22.6   4965 2389   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits **** FOUND 17:07:12.81 +63:21:22.3 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 01059_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 The candidate 01059_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161 did not pass the final checks Discovery image 3   2026 08 28.26418    2461280.76418    7.71    16:32:40.40 +66:45:16.2   7156 0322   /data_ssd/NMW-TexasTech/workdir//img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits **** FOUND 16:32:40.44 +66:45:16.3 in the exclusion list exclusion_list.txt **** make_report_in_HTML.sh Phase 2 (HTML assembly): 0s make_report_in_HTML.sh TOTAL: 4s Prepared the HTML report for the field Dra-07-Q1b1x1 with default.sex.telephoto_lens_vSTL *------ done with default.sex.telephoto_lens_vSTL ------* #### The local exclusion list is exclusion_list_local.txt #### Source monitoring: measuring positions from /data_ssd/NMW-TexasTech/workdir/img_2026-08-28_CI_Dra-07-Q1b1x1_012537_TTUQ1b1x1_1864167_6l1mTuSp/monitoring_positions.txt Read 28690 stars from the SExtractor catalog wcsmag.cat Detected star coordinate range: RA 238.2947 to 277.1701 deg, Dec +55.5242 to +67.3445 deg Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.00 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.01 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.02 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.03 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.04 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.05 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.06 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.07 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.08 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.09 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.10 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.11 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.12 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.13 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.14 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.15 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.16 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.17 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.18 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.19 Tycho-2 catalog search boundaries: RA 238.2947 to 277.1701 deg, Dec 55.5242 to 67.3445 deg Loaded 9840 Tycho-2 stars within the image boundaries (VT and BT non-zero). Relation between the catalog and instrumental magnitudes is written to calib.txt Stars used for magnitude calibration (good matches): 6127 out of 6417 total matches. Matched with Tycho-2 6417 out of 28690 detected stars. util/calibrate_single_image_with_tycho2.sh: calibrated wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits via Tycho-2 util/pixel_flux_airmass_correction processing wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits Observation time (mid-exposure, UTC): JD 2461280.76356 (FITS header) Observing site: lat= +33.748056 deg lon= -101.958333 deg east-positive (SITELAT/SITELONG FITS header keywords) Frame center (pixel 4788.5 3194.5): RA= 257.23731 deg Dec= +61.99279 deg Frame center: alt= +37.589 deg az= 320.588 deg airmass= 1.6354 Header cross-check: CENTALT= 37.556 deg (difference +0.034 deg) Header cross-check: AIRMASS= 1.6379 (we compute 1.6354) Airmass zero-point fit: OK k= +0.3689 +/- 0.0158 mag/airmass N= 4388 airmass span 1.3922-2.0445 scatter 0.1776 mag Source monitoring: airmass zero-point for wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-19-21_20.00sec_-0.00C_LIGHTs_0160.fits: OK +0.607750 -0.368862 1.6354 +0.3689 4388 0.6523 0.1776 1.3922 2.0445 Read 28582 stars from the SExtractor catalog wcsmag.cat Detected star coordinate range: RA 238.2956 to 277.2357 deg, Dec +55.5433 to +67.3510 deg Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.00 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.01 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.02 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.03 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.04 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.05 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.06 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.07 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.08 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.09 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.10 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.11 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.12 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.13 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.14 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.15 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.16 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.17 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.18 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.19 Tycho-2 catalog search boundaries: RA 238.2956 to 277.2357 deg, Dec 55.5433 to 67.3510 deg Loaded 9855 Tycho-2 stars within the image boundaries (VT and BT non-zero). Relation between the catalog and instrumental magnitudes is written to calib.txt Stars used for magnitude calibration (good matches): 6138 out of 6423 total matches. Matched with Tycho-2 6423 out of 28582 detected stars. util/calibrate_single_image_with_tycho2.sh: calibrated wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits via Tycho-2 util/pixel_flux_airmass_correction processing wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits Observation time (mid-exposure, UTC): JD 2461280.76418 (FITS header) Observing site: lat= +33.748056 deg lon= -101.958333 deg east-positive (SITELAT/SITELONG FITS header keywords) Frame center (pixel 4788.5 3194.5): RA= 257.24967 deg Dec= +62.00177 deg Frame center: alt= +37.490 deg az= 320.606 deg airmass= 1.6391 Header cross-check: CENTALT= 37.450 deg (difference +0.040 deg) Header cross-check: AIRMASS= 1.6419 (we compute 1.6391) Airmass zero-point fit: OK k= +0.3651 +/- 0.0154 mag/airmass N= 4455 airmass span 1.3937-2.0495 scatter 0.1749 mag Source monitoring: airmass zero-point for wcs_fd_Dra-07-Q1b1x1_2026-08-28_01-20-15_20.00sec_-0.00C_LIGHTs_0161.fits: OK +0.603989 -0.365072 1.6391 +0.3651 4455 0.6558 0.1749 1.3937 2.0495 ########### Completed Dra-07-Q1b1x1 ########### The analysis was running at tau We are allowed to update the exclusion list at tau host Found ../exclusion_list_TTUQ1.txt #### The exclusion list before filtering-out asteroids, bad pixels and adding Gaia sources #### ################################################################################### renamed 'exclusion_list_index_html.txt_noasteroids' -> 'exclusion_list_index_html.txt' renamed 'exclusion_list_index_html.txt_nohotpixels' -> 'exclusion_list_index_html.txt' # Count candidates with no identification (that also don't look like hot pix) Found 0 unidentified candidates (excluding asteroids, hot pixels and known variable stars). ################################################################################### 0 candidates found (excluding asteroids and hot pixels) This does not look like a test run ################################################################################### exclusion_list_gaiadr2.txt NOT FOUND exclusion_list_apass.txt NOT FOUND IS_THIS_TEST_RUN=NO ALLOW_EXCLUSION_LIST_UPDATE= YES #### Nothing to add to the exclusion list #### The observatory MPC code is V36 ############################################################ Positions of planets computed with util/planet_finder/main.py for JD(UT)2461280.76355795 -observatory V36 10:30:31.49 +11:13:54.8 Mercury (-1.9mag) 13:08:21.74 -10:25:08.3 Venus (-4.6mag) 06:46:27.10 +23:29:08.3 Mars (1.3mag) 09:00:36.66 +17:32:32.1 Jupiter (-1.8mag) 00:53:49.24 +02:53:50.5 Saturn (0.5mag) 04:13:22.97 +21:01:12.3 Uranus (5.7mag) 00:14:39.02 +00:02:55.8 Neptune (7.7mag) 20:26:20.88 -23:37:00.4 Pluto (14.5mag) 22:29:21.93 -09:33:11.4 Moon (-12.7mag) -rw-r--r-- 1 apache apache 363 Aug 28 01:29 planets.txt ############################################################ Positions of selected moons from JPL HORIZONS for JD(UT)2461280.76355795: 09:00:31.84 +17:32:56.0 Io (6.2mag) 09:00:28.05 +17:33:14.0 Europa (6.3mag) 09:00:39.68 +17:32:20.9 Ganymede (5.7mag) 09:01:05.08 +17:30:19.9 Callisto (6.9mag) 08:58:08.42 +17:43:58.0 Himalia (15.7mag) 09:00:40.15 +17:32:17.1 Thebe (16.6mag) 08:57:48.54 +17:38:55.3 Elara (17.7mag) 09:04:40.99 +17:03:29.6 Pasiphae (17.9mag) 09:02:24.86 +17:47:37.6 Carme (19.0mag) 00:53:41.41 +02:53:24.2 Titan (8.4mag) 00:53:45.58 +02:53:57.0 Rhea (9.7mag) 00:54:23.29 +02:56:18.7 Iapetus (11.1mag) 00:53:33.84 +02:53:55.9 Hyperion (14.4mag) 00:52:47.06 +02:44:35.8 Phoebe (16.4mag) -rw-r--r-- 1 apache apache 568 Aug 28 01:29 moons.txt ############################################################ Positions of selected spacecraft from JPL HORIZONS for JD(UT)2461280.76355795: 20:50:14.24 -09:00:58.2 JWST 18:38:13.98 +17:41:26.5 Chandra 10:15:06.62 -56:52:43.0 XMM-Newton -rw-r--r-- 1 apache apache 96 Aug 28 01:29 spacecraft.txt ############################################################ Positions of bright comets computed with util/comet_finder/main.py for JD(UT)2461280.76355795 -observatory V36 03:33:21.02 +18:48:39.7 17.5mag P/1996 R2 (Lagerkvist) 18:00:24.64 -34:23:10.2 14.2mag P/2010 H2 (Vales) 07:11:30.14 -69:46:27.1 17.3mag C/2014 UN271 (Bernardinelli-Bernstein) 06:14:14.89 +33:26:54.1 17.7mag C/2017 K2 (PANSTARRS) 04:33:55.77 +43:44:12.7 17.7mag P/2021 N1 (ZTF) 22:21:44.04 +29:48:06.6 17.4mag C/2022 E2 (ATLAS) 07:02:04.80 +26:10:13.3 16.8mag C/2022 N2 (PANSTARRS) 10:40:12.21 +27:36:33.5 17.0mag C/2022 QE78 (ATLAS) 09:42:11.53 +05:16:51.0 18.0mag C/2022 R6 (PANSTARRS) 20:47:21.80 +63:02:38.9 18.0mag C/2023 H5 (Lemmon) 15:33:16.21 -14:45:44.3 14.7mag C/2023 R1 (PANSTARRS) 08:29:07.35 +32:19:04.4 15.6mag C/2024 E1 (Wierzchos) 15:05:46.13 +15:26:24.9 17.8mag C/2024 G6 (ATLAS) 18:41:14.35 +43:26:55.6 13.7mag C/2024 J3 (ATLAS) 20:40:32.74 +49:39:16.9 17.5mag C/2024 R4 (PANSTARRS) 05:29:42.15 -12:55:28.3 15.2mag C/2024 T5 (ATLAS) 07:07:32.48 +20:29:54.5 17.9mag C/2025 J1 (Borisov) 11:02:12.70 +19:31:50.0 17.0mag C/2025 V2 (Rankin) 13:11:43.20 +00:54:26.4 16.9mag C/2025 Y1 (ATLAS) 16:19:23.16 +75:31:35.7 16.3mag C/2026 A2 (Bok) 03:09:14.66 +46:19:43.6 17.3mag C/2026 B2 (Sun-Gao) 12:04:06.68 +10:26:44.4 17.5mag A/2026 E1 22:17:36.25 -33:42:08.8 7.3mag 10P/Tempel 11:41:32.22 -04:44:02.6 16.3mag 29P/Schwassmann-Wachmann 11:48:20.74 -01:53:16.1 17.5mag 63P/Wild 00:49:30.20 -06:26:31.9 15.4mag 65P/Gunn 06:19:12.44 +19:55:45.6 13.7mag 78P/Gehrels 20:21:41.70 -25:29:11.1 17.3mag 84P/Giclas 03:14:55.46 +14:46:03.5 17.0mag 88P/Howell 08:43:59.62 +24:38:23.5 16.5mag 93P/Lovas 05:05:48.45 +24:44:09.8 17.1mag 112P/Urata-Niijima 07:01:12.73 +27:08:53.8 16.0mag 114P/Wiseman-Skiff 10:05:13.43 +22:56:09.6 14.9mag 123P/West-Hartley 12:24:55.79 -17:46:06.1 17.3mag 124P/Mrkos 06:04:41.89 +20:54:33.5 16.0mag 128P/Shoemaker-Holt 07:01:12.14 +17:42:05.3 17.9mag 131P/Mueller 23:57:13.97 +02:52:14.7 17.4mag 139P/Vaisala-Oterma 03:00:10.94 -18:22:04.8 12.4mag 161P/Hartley-IRAS 08:22:22.67 +38:01:37.3 16.2mag 162P/Siding Spring 10:15:00.70 +22:22:51.9 12.5mag 169P/NEAT 03:14:00.32 +09:08:43.8 17.6mag 220P/McNaught 04:20:11.40 +32:58:37.6 15.3mag 260P/McNaught 08:04:12.18 +36:38:53.4 17.3mag 295P/LINEAR 15:19:14.33 +00:53:05.9 17.8mag 391P/Kowalski 09:18:59.41 +17:21:55.6 17.9mag 450P/LONEOS -rw-r--r-- 1 apache apache 2.2K Aug 28 01:29 comets.txt ############################################################ List of recent ASAS-SN transients from https://www.astronomy.ohio-state.edu/asassn/transients.html : 04:20:07.58 -42:26:59.90 AT2026zjy 2026-08-23.03 15.91 03:08:18.02 +11:54:46.50 SN2026ymb 2026-08-23.4 16.44 20:22:32.48 -50:45:14.30 SN2026yid 2026-08-22.82 15.13 04:24:28.39 -56:20:21.60 ASASSN-26ey 2026-08-20.02 15.55 16:46:37.81 -63:14:59.80 ASASSN-26ex 2026-08-18.78 3.63 21:28:47.85 +20:31:03.60 SN 2026sfn 2026-08-16.3 17.09 23:01:28.67 -61:00:39.00 SN 2026yib 2026-08-14.85 17.36 00:22:23.20 -32:16:02.70 SN 2026whu 2026-08-14.96 16.5 19:56:21.71 -37:24:19.90 ASASSN-26ew 2026-08-13.82 14.73 13:53:14.21 +00:26:52.00 SN 2026wkv 2026-08-10.12 15.83 05:21:07.61 +23:38:20.10 TCP J05210763+2338194 2026-08-10.59 9.34 01:28:20.49 +40:13:27.10 SN2026wpd 2026-08-9.34 16.37 23:47:50.87 +49:28:49.80 SN2026wjs 2026-08-9.35 17.12 16:03:20.92 +17:43:23.70 AT2026xau 2026-08-9.3 17.71 01:10:22.05 -09:34:08.50 SN2026weo 2026-08-7.46 15.76 00:56:54.35 -35:55:29.40 AT2026wdy 2026-08-5.05 16.08 22:08:07.63 -53:03:58.90 AT2026wek 2026-08-3.82 17.17 14:51:51.34 +66:13:24.60 ASASSN-26ev 2026-08-2.15 14.02 12:06:50.79 -36:16:06.20 SN2026wgm 2026-08-1.73 15.61 16:56:36.90 -59:29:26.00 ASASSN-26er 2026-07-25.82 15.09 01:21:27.83 -10:37:05.00 SN2026vbh 2026-07-25.61 15.97 21:17:31.59 +22:25:50.90 ASASSN-26eq 2026-07-24.37 15.13 18:53:36.89 +16:56:43.60 ASASSN-26ep 2026-07-23.47 -4.06 12:18:47.98 -30:48:47.50 ASASSN-26et 2026-07-22.76 13.98 13:00:47.82 +15:42:17.60 SN2026uwk 2026-07-21.75 16.38 18:52:31.11 -32:28:00.90 ASASSN-26en 2026-07-21.77 14.63 14:42:58.01 -62:32:59.10 ASASSN-26es 2026-07-20.79 15.36 20:12:45.57 -32:53:13.00 ASASSN-26em 2026-07-20.94 16.83 18:54:24.33 -46:11:51.70 ASASSN-26eu 2026-07-20.93 14.86 03:18:56.99 -80:55:10.40 AT2026ugi 2026-07-20.03 17.12 18:43:58.40 +24:22:41.80 ASASSN-26eo 2026-07-19.36 16.16 04:50:01.03 -02:22:33.80 ASASSN-26ej 2026-07-16.17 17.02 18:34:55.28 -31:41:00.90 ASASSN-26ek 2026-07-16.24 15.73 17:07:43.61 -44:21:53.50 ASASSN-26el 2026-07-15.86 16.01 14:45:08.35 +24:13:12.30 ASASSN-26ei 2026-07-16.17 16.46 10:00:46.44 -32:36:31.10 AT 2023mhb 2026-07-14.73 16.67 14:39:37.45 -11:22:36.20 AT 2026unl 2026-07-15.27 17.11 10:49:42.57 -11:25:55.80 ASASSN-26eh 2026-07-14.72 16.58 19:33:53.06 -07:15:00.80 ASASSN-22le 2026-07-14.15 15.5 02:45:40.52 -27:55:30.30 ASASSN-26ef 2026-07-12.35 15.86 23:26:43.80 +04:42:39.70 SN 2026qtn 2026-07-12.22 16.47 02:19:17.26 +28:57:15.40 ASASSN-26ec 2026-07-11.53 2.78 18:31:15.56 -05:34:31.50 AT2026stb 2026-07-11.28 -1.29 13:36:08.24 +23:29:05.00 AT2026pjf 2026-07-10.18 -0.72 17:33:39.82 +04:22:36.70 SN2026pir 2026-07-9.86 -0.66 11:21:41.26 -50:33:36.30 ASASSN-26ed 2026-07-8.8 -1.3 23:41:42.11 +26:29:49.10 AT2026qil 2026-07-9.3 16.15 20:21:30.50 -32:03:40.10 ASASSN-26ee 2026-07-7.22 15.53 19:37:44.09 -05:35:42.80 AT2026ryu 2026-07-7.17 14.88 11:06:55.46 -04:07:04.50 AT2026qqg 2026-07-5.01 16.82 19:07:23.69 -74:13:37.30 AT2026qly 2026-07-5.02 17.31 17:57:43.80 +27:18:40.10 ASASSN-26ea 2026-07-5.07 16.67 19:59:01.43 -32:07:34.30 ASASSN-26eb 2026-07-4.97 15.52 18:46:50.35 -57:44:13.20 SN 2026qqp 2026-07-5.03 -0.92 19:17:31.69 -39:55:29.90 ASASSN-26dz 2026-07-5.14 15.91 19:14:31.37 +12:03:52.90 AT 2026rdg 2026-07-3.43 11.81 04:05:50.09 -70:24:34.40 AT 2026qpr 2026-06-30.4 15.96 13:45:37.49 -05:59:35.80 SN 2026pub 2026-06-30.09 16.01 16:41:15.63 +39:17:14.70 SN 2026pel 2026-06-26.38 16.07 10:14:40.19 -35:38:21.30 ASASSN-26dy 2026-06-25.99 15.63 14:47:21.56 -40:15:51.30 ASASSN-26dv 2026-06-23.03 14.62 13:38:49.79 -77:21:06.70 ASASSN-26dw 2026-06-23.04 16.09 00:59:27.90 +33:08:13.20 SN 2026mke 2026-06-22.39 17.13 11:10:44.73 -30:20:45.50 SN 2026nmv 2026-06-22.06 16.56 21:36:15.68 -21:19:12.50 AT2026oxh 2026-06-22.15 17.14 17:31:38.38 -56:05:51.90 ASASSN-26dx 2026-06-22.02 14.72 14:10:13.44 -38:46:46.10 AT2026pvk 2026-06-22.06 16.53 20:56:47.23 -18:31:05.20 AT2026plb 2026-06-21.31 16.4 15:44:29.68 +21:00:59.30 SN2026ore 2026-06-21.29 17.57 23:50:05.98 -14:01:41.30 AT2026oxl 2026-06-21.52 17.64 17:36:54.73 -18:10:04.20 AT2026ouj 2026-06-20.92 15.15 00:34:04.08 -30:22:09.20 AT2026ntk 2026-06-18.09 17.34 20:49:13.39 +25:17:59.20 ASASSN-26du 2026-06-15.39 15.93 23:09:30.84 +32:40:42.00 SN2026oxc 2026-06-14.35 16.83 02:02:26.78 +32:04:21.30 AT2026ovz 2026-06-14.59 15.39 21:26:28.11 -72:31:19.50 AT2026nwc 2026-06-11 17.05 17:54:57.33 +26:32:34.20 SN 2026odc 2026-06-11.23 17.62 13:55:59.94 +17:30:37.20 SN 2026nyq 2026-06-11.1 16.24 00:50:45.14 -71:38:36.90 ASASSN-26dt 2026-06-11.13 10.22 14:42:19.73 +19:11:35.60 SN2026nyp 2026-06-10.3 16.32 12:23:23.92 +12:56:43.50 SN2026mta 2026-06-8.29 16.69 12:30:18.51 +47:12:33.20 SN2026oao 2026-06-9.32 17.02 10:51:05.21 -42:28:56.60 AT2026nvf 2026-06-8.12 16.75 13:50:22.48 -07:35:00.00 SN2026npn 2026-06-8.02 17.58 00:56:07.17 +43:01:43.20 ASASSN-26dq 2026-06-7.43 13.58 01:07:49.46 +41:59:43.70 SN 2026obc 2026-06-7.43 15.15 21:11:25.22 +14:14:31.90 ASASSN-26dr 2026-06-7.24 16.24 06:21:27.06 -65:16:42.00 ASASSN-26ds 2026-06-2.97 15.02 20:07:38.15 -21:07:05.40 SN2026mho 2026-05-25.18 -1.12 11:29:42.55 +79:01:03.10 AT2026min 2026-05-24.21 16.63 11:44:32.95 -68:48:30.00 ASASSN-26no 2026-05-24 8.41 19:00:42.82 -48:31:01.60 ASASSN-26dp 2026-05-22.31 -3.28 14:23:56.72 -58:37:47.60 ASASSN-26dn 2026-05-20.01 14.64 11:24:54.06 +47:57:01.60 AT2026nma 2026-05-20.29 15.46 21:27:08.58 +33:24:38.10 AT2026lli 2026-05-19.34 15.86 00:31:01.41 -13:38:51.70 AT2026nad 2026-05-19.39 15.34 15:16:06.61 -79:16:32.40 ASASSN-26dm 2026-05-19.03 14.44 11:24:25.21 -59:23:19.10 ASASSN-26dl 2026-05-18.02 13.55 13:45:51.52 -53:16:01.00 ASASSN-26dk 2026-05-18.16 12.96 02:05:49.69 -30:29:09.60 ASASSN-26dh 2026-05-18.43 15.37 -rw-r--r-- 1 apache apache 5.7K Aug 28 01:29 asassn_transients_list.txt ############################################################ Truncated list of TOCP transients from http://www.cbat.eps.harvard.edu/unconf/tocp.html : 02:19:17.36 +28:57:15.8 TCP J02191736+2857158 2026-07-12.3549 12.5mag 00:44:56.43 +41:57:41.6 PNV J00445643+4157416 2026-07-13.8026 17.98Cmag 00:42:55.36 +41:17:27.0 PNV J00425536+4117270 2026-07-20.1813 17.7mag 20:35:43.64 +61:31:32.9 TCP J20354364+6131329 2026-07-20.5443 14.4mag 21:17:31.48 +22:25:51.0 TCP J21173148+2225510 2026-07-23.5577 14.8mag 00:41:24.04 +40:49:02.8 PNV J00412404+4049028 2026-07-25.0157 18.7mag 00:43:04.26 +41:02:28.6 PNV J00430426+4102286 2026-07-26.1512 20mag 14:51:51.40 +66:13:24.0 TCP J14515140+6613240 2026-07-29.2561 13.5mag 00:43:06.15 +41:22:08.2 PNV J00430615+4122082 2026-07-30.0085 19.4mag 00:41:33.23 +41:10:12.2 PNV J00413323+4110122 2026-08-02.8913 17.1mag 05:21:07.63 +23:38:19.4 TCP J05210763+2338194 2026-08-06.4109 11.2mag 22:57:17.96 +47:07:41.8 TCP J22571796+4707418 2026-08-09.3289 14.3mag 09:13:38.17 +76:28:18.1 PSN J09133817+7628181 2026-08-09.8037 15.4mag 00:43:17.29 +41:26:48.6 PNV J00431729+4126486 2026-08-14.0920 16.8mag 00:42:52.82 +41:10:58.6 PNV J00425282+4110586 2026-08-17.7723 19.9mag 00:42:52.83 +41:10:59.6 PNV J00425283+4110596 2026-08-18.6119 19.3mag 18:25:12.76 -22:25:29.3 TCP J18251276-2225293 2026-08-19.1062 9.4mag 18:03:09.04 +12:18:14.0 TCP J18030904+1218140 2026-08-19.5199 14.9mag 19:45:06.48 +18:22:42.2 PNV J19450648+1822422 2026-08-25.1278 9.0mag 00:42:54.65 +41:22:59.3 PNV J00425465+4122593 2026-08-25.4712 18.9mag -rw-r--r-- 1 apache apache 190K Aug 28 01:29 tocp_transients_list.txt ############################################################ Truncated list of recent TNS transients from https://www.wis-tns.org/ : 23:24:16.986 -39:54:38.19 AT 2026xsr 2026-08-01.59 19.34 14:05:54.276 -15:52:29.96 AT 2026xsq 2026-02-17.61 20.88 16:00:02.823 +12:57:02.46 AT 2026xsp 2026-02-13.59 21.18 13:18:25.859 +25:17:53.19 AT 2026xso 2026-02-17.52 21.43 14:46:41.619 +11:38:04.02 AT 2026xsn 2026-02-17.55 20.37 14:12:17.965 +35:36:02.21 AT 2026xsm 2026-02-17.60 20.93 00:28:22.210 -09:16:55.88 AT 2026xsl 2026-08-06.67 20.38 13:40:02.666 +27:45:49.66 AT 2026xsk 2026-02-17.50 21.05 13:18:58.760 +35:13:29.33 AT 2026xsj 2026-02-17.49 21.16 14:58:55.200 +08:49:53.06 AT 2026xsi 2026-02-13.58 21.13 12:22:18.795 +12:08:10.55 AT 2026xsh 2026-02-16.62 20.67 11:46:22.552 +13:15:39.41 AT 2026xsg 2026-02-16.57 20.7 08:55:07.272 +15:47:59.14 AT 2026xsf 2026-02-13.30 20.98 07:34:01.728 +10:29:15.79 AT 2026xse 2026-02-14.26 20.11 07:29:49.030 +19:09:23.06 AT 2026xsd 2026-02-13.26 20.62 07:42:52.595 +22:58:08.19 AT 2026xsc 2026-02-13.26 20.93 04:42:06.854 +06:56:13.00 AT 2026xsb 2026-02-06.24 21.16 05:10:23.116 -06:04:42.26 AT 2026xsa 2026-02-05.30 20.59 05:17:11.087 -07:32:29.20 AT 2026xrz 2026-02-02.30 20.34 08:18:15.789 -07:48:37.88 AT 2026xry 2026-01-28.38 20.53 -rw-r--r-- 1 apache apache 88K Aug 28 01:29 tns_transients_list.txt

Profiling:

CPU temperature: 94 C