NMW transient search results

This analysis is done by the script util/transients/transient_factory_test31.sh /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F

The list of candidates will appear below. Please manually reload the page every few minutes untill the 'Processing complete' message appears.

Processing fields Dra-07-Q2b1x1

Processing complete!

Total number of candidates identified: 0

FITS images used in this processing run:

Field Dra-07-Q2b1x1 reference image: Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits
Field Dra-07-Q2b1x1 reference image: Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits
Field Dra-07-Q2b1x1 second-epoch image: Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits
Field Dra-07-Q2b1x1 second-epoch image: Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits

Processing log:

Filtering log:

######## Processing parameters ########
AAVSO_COMMENT_STRING= NMW-TexasTech Camera-2 135mm f/2.2 telephoto lens + QHY600M CMOS
ASTCHECK_ASTEROID_SEARCH_RADIUS_ARCSEC= 
BAD_REGION_FILE= /var/www/nmw_calibration/TTUQ2b1x1/TTUQ2_bad_region.lst
CAMERA_SETTINGS= TTUQ2b1x1
CHECK_POINTING_ACCURACY= yes
DARK_FRAMES_DIR_OR_FILE= /var/www/nmw_calibration/TTUQ2b1x1/darks
EXCLUSION_LIST= ../exclusion_list_TTUQ2.txt
FILTER_BAD_IMG__MAX_APERTURE_STAR_SIZE_PIX= 12.5
FILTER_BAD_IMG__MAX_ELONGATION_AminusB_PIX= 0.55
FILTER_BAD_IMG__MIN_APERTURE_STAR_SIZE_PIX= 2.0
FILTER_BRIGHT_MAG_CUTOFF_TRANSIENT_SEARCH= -5
FILTER_FAINT_MAG_CUTOFF_TRANSIENT_SEARCH= 15.5
FLAT_FIELD_DIR_OR_FILE= /var/www/nmw_calibration/TTUQ2b1x1/flats
FRAME_EDGE_OFFSET_PIX= 600
GAIA_BAND_FOR_CATALOGED_SOURCE_CHECK= 
MAX_NEW_TO_REF_MEAN_IMG_VALUE_RATIO= 100
MAX_NEW_IMG_MEAN_VALUE= 25000
MAX_SD_RATIO_OF_SECOND_EPOCH_IMGS= 0.18
MAX_SD_RATIO_OF_SECOND_EPOCH_IMGS_SOFT_LIMIT= 0.12
MPC_CODE= V36
NMW_CALIBRATION= /var/www/nmw_calibration
NUMBER_OF_DETECTED_TRANSIENTS_BEFORE_FILTERING_HARD_LIMIT= 10000
NUMBER_OF_DETECTED_TRANSIENTS_BEFORE_FILTERING_SOFT_LIMIT= 8000
OMP_NUM_THREADS= 
ONLINE_MPCHECKER_BUTTON_ASTEROID_SEARCH_RADIUS_ARCMIN= 
PHOTOMETRIC_CALIBRATION= 
REQUIRE_PIX_SHIFT_BETWEEN_IMAGES_FOR_TRANSIENT_CANDIDATES= yes
SEXTRACTOR_CONFIG_BRIGHTSTARPASS= default.sex.telephoto_lens_onlybrightstars_v1
SEXTRACTOR_CONFIG_FILES= default.sex.telephoto_lens_onlybrightstars_v1 default.sex.telephoto_lens_vSTL
STARMATCH_RADIUS_PIX= 5
SYSREM_ITERATIONS= 0
TELESCOP= 
TELESCOP_NAME_KNOWN_TO_VaST_FOR_FOV_DETERMINATION= 
UCAC5_PLATESOLVE_ITERATIONS= 2
FPACK_FULLY_CALIBRATED_IMAGE= no
#######################################
HOSTNAME= tau
USER= 
HOME= 
#######################################
SExtractor catalog cache: enabled, directory /data_ssd/NMW-TexasTech/vast_sextractor_cache
Reference image directory is set to /data_ssd/NMW-TexasTech/reference_imgs
VIZIER_SITE=vizier.cds.unistra.fr
GAIA_DR2_CLIENT=vizquery (lib/vizquery -> VizieR vizier.cds.unistra.fr)
INFO: MAKE_PNG_PLOTS is set to yes
FITS_FILE_EXT=fits
CALIBRATION_STATUS_PREFIX=
Fields in the data directory: 
Dra-07-Q2b1x1
#######################################
########### Starting Dra-07-Q2b1x1 ###########
Processing Dra-07-Q2b1x1
server tau has sufficient free disk space available: 720917 MB at /data_ssd/NMW-TexasTech/workdir
server tau has sufficient free disk space available: 720917 MB at .
Checking input images (2 new)
REFERENCE_EPOCH__FIRST_IMAGE= /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits
REFERENCE_EPOCH__SECOND_IMAGE= /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits
Small preview (one of the new images): 
Large previews of the second-epoch (new) images:
MAKE_PNG_PLOTS=yes
renamed 'Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.png' -> 'transient_report/Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits_preview.png'
Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits

renamed 'Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.png' -> 'transient_report/Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits_preview.png'
Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits


Read-check the input FITS images... read-check OK Blank image check the input FITS images... blank-image-check OK Read date check the input FITS images... read-date-check OK Mean value check the input FITS images... OK, at least two new images have mean values below the threshold. ---------------------------------------------- INFO: REFERENCE_EPOCH__FIRST_IMAGE_MEAN_VALUE= 396.0722 INFO: REFERENCE_EPOCH__FIRST_IMAGE_SD= 539.7815 INFO: SECOND_EPOCH__FIRST_IMAGE_MEAN_VALUE= 945.1472 INFO: SECOND_EPOCH__FIRST_IMAGE_SD= 505.7742 INFO: SECOND_EPOCH__SECOND_IMAGE_MEAN_VALUE= 945.1170 INFO: SECOND_EPOCH__SECOND_IMAGE_SD= 505.4115 ---------------------------------------------- INFO: ref_to_second_epoch_img_mean_ratio= 2.3863 INFO: SECOND_EPOCH__SD_ratio= 0.001 ---------------------------------------------- Calibration settings: DARK_FRAMES_DIR_OR_FILE=/var/www/nmw_calibration/TTUQ2b1x1/darks FLAT_FIELD_DIR_OR_FILE=/var/www/nmw_calibration/TTUQ2b1x1/flats EXPTIME = 20.0 / [s] Exposure duration SET-TEMP= 5.0 / [degC] CCD temperature setpoint CCD-TEMP= 4.9 / [degC] CCD temperature FOCTEMP = 25.2099990844727 / [degC] Focuser temperature AMBTEMP = 26.1 / [degC] Ambient air temperature Exploring image header: /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits CCD-TEMP= 4.900000 for /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits SET-TEMP= 5.000000 for /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits Header: 74 keys total, 33 keys left Record 0: "" status=0 Record 1: "SIMPLE = T / C# FITS" status=0 Record 2: "BITPIX = 16" status=0 Record 3: "NAXIS = 2 / Dimensionality" status=0 Record 4: "NAXIS1 = 9576" status=0 Record 5: "NAXIS2 = 6388" status=0 Record 6: "BZERO = 32768" status=0 Record 7: "EXTEND = T / Extensions are permitted" status=0 Record 8: "IMAGETYP= 'LIGHT' / Type of exposure" status=0 Record 9: "EXPOSURE= 20.0 / [s] Exposure duration" status=0 Record 10: "EXPTIME = 20.0 / [s] Exposure duration" status=0 Record 11: "DATE-LOC= '2026-07-23T03:01:25.4746394' / Time of observation (local)" status=0 Record 12: "DATE-OBS= '2026-07-23T08:01:25.4746394' / Time of observation (UTC)" status=0 Record 13: "MJD-OBS = 61244.3343226155 / Modified Julian Date of observation" status=0 Record 14: "DATE-AVG= '2026-07-23T08:01:35.3784022' / Averaged midpoint time (UTC)" status=0 Record 15: "MJD-AVG = 61244.3344372455 / Modified Julian Date of averaged midpoint" status=0 Record 16: "XBINNING= 1 / X axis binning factor" status=0 Record 17: "YBINNING= 1 / Y axis binning factor" status=0 Record 18: "GAIN = 30 / Sensor gain" status=0 Record 19: "OFFSET = 30 / Sensor gain offset" status=0 Record 20: "XPIXSZ = 3.76 / [um] Pixel X axis size" status=0 Record 21: "YPIXSZ = 3.76 / [um] Pixel Y axis size" status=0 Record 22: "INSTRUME= 'QHY600M' / Imaging instrument name" status=0 Record 23: "CAMERAID= 'QHY600M-84137c4dbbbd119a9' / Imaging instrument identifier" status=0 Record 24: "SET-TEMP= 5.0 / [degC] CCD temperature setpoint" status=0 Record 25: "CCD-TEMP= 4.9 / [degC] CCD temperature" status=0 Record 26: "READOUTM= '2CMS-0' / Sensor readout mode" status=0 Record 27: "USBLIMIT= 50 / Camera-specific USB setting" status=0 Record 28: "TELESCOP= 'QHY600M-TTU2' / Name of telescope" status=0 Record 29: "FOCALLEN= 135.0 / [mm] Focal length" status=0 Record 30: "FOCRATIO= 2.2 / Focal ratio" status=0 Record 31: "RA = 257.145539305337 / [deg] RA of telescope" status=0 Record 32: "DEC = 61.999700634252 / [deg] Declination of telescope" status=0 Record 33: "CENTALT = 42.2052777777778 / [deg] Altitude of telescope" status=0 Record 34: "CENTAZ = 325.811111111111 / [deg] Azimuth of telescope" status=0 Record 35: "AIRMASS = 1.48680967693652 / Airmass at frame center (Gueymard 1993)" status=0 Record 36: "PIERSIDE= 'East' / Telescope pointing state" status=0 Record 37: "SITEELEV= 1009.5 / [m] Observation site elevation" status=0 Record 38: "SITELAT = 33.7482925 / [deg] Observation site latitude" status=0 Record 39: "SITELONG= -101.958319 / [deg] Observation site longitude" status=0 Record 40: "OBSERVER= 'Sokolovsky' / Observer name" status=0 Record 41: "OBSERVAT= 'TTU Skyview' / Observatory name" status=0 Record 42: "SITENAME= '' / Observatory site name" status=0 Record 43: "FWHEEL = 'Simulator' / Filter Wheel name" status=0 Record 44: "FILTER = 'CV' / Active filter name" status=0 Record 45: "OBJECT = 'Dra-07' / Name of the object of interest" status=0 Record 46: "OBJCTRA = '17 08 34' / [H M S] RA of imaged object" status=0 Record 47: "OBJCTDEC= '+62 00 00' / [D M S] Declination of imaged object" status=0 Record 48: "OBJCTROT= 0.0 / [deg] planned rotation of imaged object" status=0 Record 49: "FOCNAME = 'ZWO Focuser' / Focusing equipment name" status=0 Record 50: "FOCPOS = 20437 / [step] Focuser position" status=0 Record 51: "FOCUSPOS= 20437 / [step] Focuser position" status=0 Record 52: "FOCUSSZ = 0.0 / [um] Focuser step size" status=0 Record 53: "FOCTEMP = 25.2099990844727 / [degC] Focuser temperature" status=0 Record 54: "FOCUSTEM= 25.2099990844727 / [degC] Focuser temperature" status=0 Record 55: "DEWPOINT= 16.4 / [degC] Dew point" status=0 Record 56: "HUMIDITY= 55.0 / [percent] Relative humidity" status=0 Record 57: "PRESSURE= 902.81 / [hPa] Air pressure" status=0 Record 58: "AMBTEMP = 26.1 / [degC] Ambient air temperature" status=0 Record 59: "WINDDIR = 17.0 / [deg] Wind direction: 0=N, 180=S, 90=E, 270=W" status=0 Record 60: "WINDGUST= 7.200576 / [kph] Wind gust" status=0 Record 61: "WINDSPD = 4.00032 / [kph] Wind speed" status=0 Record 62: "ROWORDER= 'TOP-DOWN' / FITS Image Orientation" status=0 Record 63: "EQUINOX = 2000.0 / Equinox of celestial coordinate system" status=0 Record 64: "SWCREATE= 'N.I.N.A. 3.2.0.9001 (x64)' / Software that created this file" status=0 Record 65: "QHY_EXP = 20.000096 / [s] Actual exposure time" status=0 Record 66: "QHY_PP = 13888.0 / [ps] pixelPeriod" status=0 Record 67: "QHY_LP = 85000.0 / [ns] linePeriod" status=0 Record 68: "GPS_LP = 85000.0 / [ns] linePeriod" status=0 Record 69: "QHY_FP = 20000160.0 / [us] framePeriod" status=0 Record 70: "QHY_CPL = 6120.0 / clocksPerLine" status=0 Record 71: "QHY_LPF = 235295.0 / linesPerFrame" status=0 Record 72: "QHY_AET = 20000096.0 / [us] actualExposureTime" status=0 Record 73: "QHY_LEM = T / isLongExposureMode" status=0 Record 74: "QHY_OFF0= 3767.777 / [us] RollingShutterEndOffset row 0" status=0 Allocating memory for image, dark and result arrays... Reading image /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits 9576 6388 16 bitpix SET-TEMP= 5.000000 for /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits SET-TEMP= 5.000000 for /var/www/nmw_calibration/TTUQ2b1x1/darks/mdark_TTUQ2b1x1_5C_20s_2026-07-08.fit CCD-TEMP= 4.900000 for /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits CCD-TEMP= 4.900000 for /var/www/nmw_calibration/TTUQ2b1x1/darks/mdark_TTUQ2b1x1_5C_20s_2026-07-08.fit Reading dark frame /var/www/nmw_calibration/TTUQ2b1x1/darks/mdark_TTUQ2b1x1_5C_20s_2026-07-08.fit 9576 6388 16 bitpix Dark frame is subtracted, output is written to /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/d_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits :) Spent 0.643633 seconds renamed 'mdark_TTUQ2b1x1_5C_20s_2026-07-08.png' -> 'transient_report/dark.png' try_to_calibrate_the_input_frame(): selected flat field /var/www/nmw_calibration/TTUQ2b1x1/flats/mff_TTUQ2b1x1_2026-07-08.fit from directory /var/www/nmw_calibration/TTUQ2b1x1/flats MegaDivider v7 Reading image /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/d_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits 9576 6388 16 bitpix Reading flat /var/www/nmw_calibration/TTUQ2b1x1/flats/mff_TTUQ2b1x1_2026-07-08.fit 9576 6388 16 bitpix Avarage count on flat field image: 33794.829350 Minimal real count (from overscan): 5 Output is written to /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits :) No overscan detected - all values seem high! (left_median=21727.0, right_median=27156.0) renamed 'mff_TTUQ2b1x1_2026-07-08.png' -> 'transient_report/flat.png' Using calibrated image CALIBRATED_SECOND_EPOCH__FIRST_IMAGE=/data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits EXPTIME = 20.0 / [s] Exposure duration SET-TEMP= 5.0 / [degC] CCD temperature setpoint CCD-TEMP= 4.9 / [degC] CCD temperature FOCTEMP = 25.2099990844727 / [degC] Focuser temperature AMBTEMP = 26.1 / [degC] Ambient air temperature Exploring image header: /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits CCD-TEMP= 4.900000 for /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits SET-TEMP= 5.000000 for /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits Header: 74 keys total, 33 keys left Record 0: "" status=0 Record 1: "SIMPLE = T / C# FITS" status=0 Record 2: "BITPIX = 16" status=0 Record 3: "NAXIS = 2 / Dimensionality" status=0 Record 4: "NAXIS1 = 9576" status=0 Record 5: "NAXIS2 = 6388" status=0 Record 6: "BZERO = 32768" status=0 Record 7: "EXTEND = T / Extensions are permitted" status=0 Record 8: "IMAGETYP= 'LIGHT' / Type of exposure" status=0 Record 9: "EXPOSURE= 20.0 / [s] Exposure duration" status=0 Record 10: "EXPTIME = 20.0 / [s] Exposure duration" status=0 Record 11: "DATE-LOC= '2026-07-23T03:02:05.8912974' / Time of observation (local)" status=0 Record 12: "DATE-OBS= '2026-07-23T08:02:05.8912974' / Time of observation (UTC)" status=0 Record 13: "MJD-OBS = 61244.3347904049 / Modified Julian Date of observation" status=0 Record 14: "DATE-AVG= '2026-07-23T08:02:15.7936047' / Averaged midpoint time (UTC)" status=0 Record 15: "MJD-AVG = 61244.3349050116 / Modified Julian Date of averaged midpoint" status=0 Record 16: "XBINNING= 1 / X axis binning factor" status=0 Record 17: "YBINNING= 1 / Y axis binning factor" status=0 Record 18: "GAIN = 30 / Sensor gain" status=0 Record 19: "OFFSET = 30 / Sensor gain offset" status=0 Record 20: "XPIXSZ = 3.76 / [um] Pixel X axis size" status=0 Record 21: "YPIXSZ = 3.76 / [um] Pixel Y axis size" status=0 Record 22: "INSTRUME= 'QHY600M' / Imaging instrument name" status=0 Record 23: "CAMERAID= 'QHY600M-84137c4dbbbd119a9' / Imaging instrument identifier" status=0 Record 24: "SET-TEMP= 5.0 / [degC] CCD temperature setpoint" status=0 Record 25: "CCD-TEMP= 4.9 / [degC] CCD temperature" status=0 Record 26: "READOUTM= '2CMS-0' / Sensor readout mode" status=0 Record 27: "USBLIMIT= 50 / Camera-specific USB setting" status=0 Record 28: "TELESCOP= 'QHY600M-TTU2' / Name of telescope" status=0 Record 29: "FOCALLEN= 135.0 / [mm] Focal length" status=0 Record 30: "FOCRATIO= 2.2 / Focal ratio" status=0 Record 31: "RA = 257.145539365052 / [deg] RA of telescope" status=0 Record 32: "DEC = 61.9997005998749 / [deg] Declination of telescope" status=0 Record 33: "CENTALT = 42.1269444444444 / [deg] Altitude of telescope" status=0 Record 34: "CENTAZ = 325.799722222222 / [deg] Azimuth of telescope" status=0 Record 35: "AIRMASS = 1.48904669399544 / Airmass at frame center (Gueymard 1993)" status=0 Record 36: "PIERSIDE= 'East' / Telescope pointing state" status=0 Record 37: "SITEELEV= 1009.5 / [m] Observation site elevation" status=0 Record 38: "SITELAT = 33.7482925 / [deg] Observation site latitude" status=0 Record 39: "SITELONG= -101.958319 / [deg] Observation site longitude" status=0 Record 40: "OBSERVER= 'Sokolovsky' / Observer name" status=0 Record 41: "OBSERVAT= 'TTU Skyview' / Observatory name" status=0 Record 42: "SITENAME= '' / Observatory site name" status=0 Record 43: "FWHEEL = 'Simulator' / Filter Wheel name" status=0 Record 44: "FILTER = 'CV' / Active filter name" status=0 Record 45: "OBJECT = 'Dra-07' / Name of the object of interest" status=0 Record 46: "OBJCTRA = '17 08 34' / [H M S] RA of imaged object" status=0 Record 47: "OBJCTDEC= '+62 00 00' / [D M S] Declination of imaged object" status=0 Record 48: "OBJCTROT= 0.0 / [deg] planned rotation of imaged object" status=0 Record 49: "FOCNAME = 'ZWO Focuser' / Focusing equipment name" status=0 Record 50: "FOCPOS = 20437 / [step] Focuser position" status=0 Record 51: "FOCUSPOS= 20437 / [step] Focuser position" status=0 Record 52: "FOCUSSZ = 0.0 / [um] Focuser step size" status=0 Record 53: "FOCTEMP = 25.2099990844727 / [degC] Focuser temperature" status=0 Record 54: "FOCUSTEM= 25.2099990844727 / [degC] Focuser temperature" status=0 Record 55: "DEWPOINT= 16.4 / [degC] Dew point" status=0 Record 56: "HUMIDITY= 55.0 / [percent] Relative humidity" status=0 Record 57: "PRESSURE= 902.81 / [hPa] Air pressure" status=0 Record 58: "AMBTEMP = 26.1 / [degC] Ambient air temperature" status=0 Record 59: "WINDDIR = 17.0 / [deg] Wind direction: 0=N, 180=S, 90=E, 270=W" status=0 Record 60: "WINDGUST= 7.200576 / [kph] Wind gust" status=0 Record 61: "WINDSPD = 4.00032 / [kph] Wind speed" status=0 Record 62: "ROWORDER= 'TOP-DOWN' / FITS Image Orientation" status=0 Record 63: "EQUINOX = 2000.0 / Equinox of celestial coordinate system" status=0 Record 64: "SWCREATE= 'N.I.N.A. 3.2.0.9001 (x64)' / Software that created this file" status=0 Record 65: "QHY_EXP = 20.000096 / [s] Actual exposure time" status=0 Record 66: "QHY_PP = 13888.0 / [ps] pixelPeriod" status=0 Record 67: "QHY_LP = 85000.0 / [ns] linePeriod" status=0 Record 68: "GPS_LP = 85000.0 / [ns] linePeriod" status=0 Record 69: "QHY_FP = 20000160.0 / [us] framePeriod" status=0 Record 70: "QHY_CPL = 6120.0 / clocksPerLine" status=0 Record 71: "QHY_LPF = 235295.0 / linesPerFrame" status=0 Record 72: "QHY_AET = 20000096.0 / [us] actualExposureTime" status=0 Record 73: "QHY_LEM = T / isLongExposureMode" status=0 Record 74: "QHY_OFF0= 3767.777 / [us] RollingShutterEndOffset row 0" status=0 Allocating memory for image, dark and result arrays... Reading image /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits 9576 6388 16 bitpix SET-TEMP= 5.000000 for /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits SET-TEMP= 5.000000 for /var/www/nmw_calibration/TTUQ2b1x1/darks/mdark_TTUQ2b1x1_5C_20s_2026-07-08.fit CCD-TEMP= 4.900000 for /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits CCD-TEMP= 4.900000 for /var/www/nmw_calibration/TTUQ2b1x1/darks/mdark_TTUQ2b1x1_5C_20s_2026-07-08.fit Reading dark frame /var/www/nmw_calibration/TTUQ2b1x1/darks/mdark_TTUQ2b1x1_5C_20s_2026-07-08.fit 9576 6388 16 bitpix Dark frame is subtracted, output is written to /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/d_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits :) Spent 0.600830 seconds renamed 'mdark_TTUQ2b1x1_5C_20s_2026-07-08.png' -> 'transient_report/dark.png' try_to_calibrate_the_input_frame(): selected flat field /var/www/nmw_calibration/TTUQ2b1x1/flats/mff_TTUQ2b1x1_2026-07-08.fit from directory /var/www/nmw_calibration/TTUQ2b1x1/flats MegaDivider v7 Reading image /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/d_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits 9576 6388 16 bitpix Reading flat /var/www/nmw_calibration/TTUQ2b1x1/flats/mff_TTUQ2b1x1_2026-07-08.fit 9576 6388 16 bitpix Avarage count on flat field image: 33794.829350 Minimal real count (from overscan): 5 Output is written to /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits :) No overscan detected - all values seem high! (left_median=21727.0, right_median=27156.0) renamed 'mff_TTUQ2b1x1_2026-07-08.png' -> 'transient_report/flat.png' Using calibrated image CALIBRATED_SECOND_EPOCH__SECOND_IMAGE=/data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits Dark frame used to calibrate the second-epoch images:

Flat field used to calibrate the second-epoch images:

after the calibration attempt: SECOND_EPOCH__FIRST_IMAGE=/data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits SECOND_EPOCH__SECOND_IMAGE=/data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits Previews of the CALIBRATED second-epoch images:

fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits


fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits


Updating neverexclude_list.txt '/var/www/nmw_calibration/neverexclude_list.txt' -> './neverexclude_list.txt' Choosing bad regions list '/var/www/nmw_calibration/TTUQ2b1x1/TTUQ2_bad_region.lst' -> 'bad_region.lst' wait *------ default.sex.telephoto_lens_onlybrightstars_v1 ------* 'default.sex.telephoto_lens_onlybrightstars_v1' -> 'default.sex' Starting VaST with default.sex.telephoto_lens_onlybrightstars_v1 ./vast --noflagimage --starmatchraius 5 --matchstarnumber 500 --selectbestaperture --sysrem 0 --type 4 --maxsextractorflag 99 --UTC --nofind --nojdkeyword /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits SExtractor catalog cache: saved Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.cat to cache SExtractor catalog cache: saved Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits.cat to cache VaST run complete with default.sex.telephoto_lens_onlybrightstars_v1 The four input images were /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits Checking WCS cache directory local_wcs_cache Checking WCS cache directory /mnt/usb/NMW_NG/solved_reference_images Found WCS cache directory /mnt/usb/NMW_NG/solved_reference_images Checking WCS cache directory /home/NMW_web_upload/solved_reference_images Checking WCS cache directory /dataX/kirx/NMW_NG_rt3_autumn2019/solved_reference_images The reference JD(UT) for computing planet and comet positions: 2461244.83443836 Re-using ../asassn_transients_list.txt '../asassn_transients_list.txt' -> 'asassn_transients_list.txt' Re-using ../tocp_transients_list.txt '../tocp_transients_list.txt' -> 'tocp_transients_list.txt' Re-using ../tns_transients_list.txt '../tns_transients_list.txt' -> 'tns_transients_list.txt' Plate-solving the images wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits exists and is non-empty Saving wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits to local_wcs_cache/ 'wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits' -> 'local_wcs_cache/wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits' wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits exists and is non-empty Saving wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits to local_wcs_cache/ 'wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits' -> 'local_wcs_cache/wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits' wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits exists and is non-empty Saving wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits to local_wcs_cache/ 'wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits' -> 'local_wcs_cache/wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits' wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits exists and is non-empty Saving wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits to local_wcs_cache/ 'wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits' -> 'local_wcs_cache/wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits' ################################### # fov_of_wcs_calibrated_image.sh output for wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits (1st reference image) verification OK: wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits Image size: 937.1'x624.0' 15.6(deg)x10.4(deg) 9576x6388 pix Image scale: 5.87"/pix along the X axis and 5.86"/pix along the Y axis Image center: 17:08:34.611 +61:59:42.08 J2000 4789.000 3195.000 ################################### The image scale is 5.87"/pix, setting the soft and hard astrometric limits for filtering second-epoch detections: 5.9" and 8.8" ################################### # fov_of_wcs_calibrated_image.sh output for wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits (1st new image) verification OK: wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits Image size: 937.1'x624.0' 15.6(deg)x10.4(deg) 9576x6388 pix Image scale: 5.87"/pix along the X axis and 5.86"/pix along the Y axis Image center: 17:08:36.853 +61:59:33.67 J2000 4789.000 3195.000 ################################### ################################### # Check the image center offset between the reference and the first second-epoch image (pointing accuracy) Reference image center 17:08:34.611 +61:59:42.08 Second-epoch image center 17:08:36.853 +61:59:33.67 Angular distance between the image centers 0.0050 deg. Soft limit: 0.50 deg. Hard limit: 1.00 deg. ################################### ################################### # fov_of_wcs_calibrated_image.sh output for wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits (2nd new image) verification OK: wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits Image size: 937.1'x624.0' 15.6(deg)x10.4(deg) 9576x6388 pix Image scale: 5.87"/pix along the X axis and 5.86"/pix along the Y axis Image center: 17:08:34.117 +61:59:37.00 J2000 4789.000 3195.000 ################################### ################################### # Check the image center offset between the reference and the second second-epoch image (pointing accuracy) Reference image center 17:08:34.611 +61:59:42.08 Second-epoch image center 17:08:34.117 +61:59:37.00 Angular distance between the image centers 0.0017 deg. ################################### ################################### # Check the image center offset between the first and the second second-epoch image (shift should be applied between the second-epoch images) Second-epoch first image center 17:08:36.853 +61:59:33.67 Second-epoch second image center 17:08:34.117 +61:59:37.00 Angular distance between the image centers 0.00543 deg. ################################### Running solve_plate_with_UCAC5... Preparing for a parallel run Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits &> /tmp/tmp.CWbzuqaOA1 Parallel run for /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits &> /tmp/tmp.YP5kjdxU58 Parallel run for /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits &> /tmp/tmp.lSwyAsbgln Parallel run for /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits &> /tmp/tmp.pbw6w0epnU Parallel run for /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits Calibrating the magnitude scale Found non-empty wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits ____ Start of magnitude calibration ____ PHOTOMETRIC_CALIBRATION=TYCHO2_V Calibrating the magnitude scale with Tycho-2 stars util/transients/transient_factory_test31.sh is checking for the presence of non-empty wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits and wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat wait (drain background util/solve_plate_with_UCAC5 jobs before Tycho-2 calibration -- avoids wcs_.fits write race) Tycho-2 catalog is found at lib/catalogs/tycho2 Tycho-2 catalog and the derived bright star exclusion list are ready Checking for the presence of non-empty wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits and wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat Found non-empty wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits and wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat The reference image (wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits) and catalog (wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat) found 'wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat' -> 'wcsmag.cat' Read 12417 stars from the SExtractor catalog wcsmag.cat Detected star coordinate range: RA 237.8607 to 276.6328 deg, Dec +55.9095 to +67.2593 deg Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.00 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.01 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.02 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.03 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.04 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.05 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.06 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.07 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.08 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.09 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.10 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.11 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.12 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.13 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.14 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.15 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.16 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.17 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.18 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.19 Tycho-2 catalog search boundaries: RA 237.8607 to 276.6328 deg, Dec 55.9095 to 67.2593 deg Loaded 9265 Tycho-2 stars within the image boundaries (VT and BT non-zero). Relation between the catalog and instrumental magnitudes is written to calib.txt Stars used for magnitude calibration (good matches): 6067 out of 6312 total matches. Matched with Tycho-2 6312 out of 12417 detected stars. The calibration function type and coefficients are written to calib.txt_param util/calibrate_magnitude_scale 0.000000 1.000000 22.773800 a=0.000000 b=1.000000 c=22.773800 From vast_summary.log: estimated ref. image limiting mag.: -7.36 Updating vast_summary.log: Estimated ref. image limiting mag.: 15.41 Updated vast_limiting_magnitude.log with calibrated magnitudes Working... Please, PLEASE, be patient!!! All lightcurves processed! =) Estimated ref. image limiting mag.: 15.41
Lightcurve magnitude calibration plot:

Preparing per-reference-image forced-photometry calibration (method=tycho2 band=V) Read 12417 stars from the SExtractor catalog wcsmag.cat Detected star coordinate range: RA 237.8607 to 276.6328 deg, Dec +55.9095 to +67.2593 deg Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.00 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.01 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.02 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.03 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.04 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.05 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.06 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.07 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.08 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.09 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.10 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.11 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.12 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.13 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.14 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.15 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.16 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.17 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.18 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.19 Tycho-2 catalog search boundaries: RA 237.8607 to 276.6328 deg, Dec 55.9095 to 67.2593 deg Loaded 9265 Tycho-2 stars within the image boundaries (VT and BT non-zero). Relation between the catalog and instrumental magnitudes is written to calib.txt Stars used for magnitude calibration (good matches): 6067 out of 6312 total matches. Matched with Tycho-2 6312 out of 12417 detected stars. util/calibrate_single_image_with_tycho2.sh: calibrated wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits via Tycho-2
Single-image forced-photometry magnitude calibration plot for wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits:

Forced-photometry filter: calibrated wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits -> calib.txt_param_ref_wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits (aperture=6.2) Read 12355 stars from the SExtractor catalog wcsmag.cat Detected star coordinate range: RA 237.8606 to 276.6324 deg, Dec +55.9095 to +67.2524 deg Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.00 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.01 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.02 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.03 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.04 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.05 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.06 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.07 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.08 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.09 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.10 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.11 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.12 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.13 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.14 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.15 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.16 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.17 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.18 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.19 Tycho-2 catalog search boundaries: RA 237.8606 to 276.6324 deg, Dec 55.9095 to 67.2524 deg Loaded 9256 Tycho-2 stars within the image boundaries (VT and BT non-zero). Relation between the catalog and instrumental magnitudes is written to calib.txt Stars used for magnitude calibration (good matches): 6050 out of 6317 total matches. Matched with Tycho-2 6317 out of 12355 detected stars. util/calibrate_single_image_with_tycho2.sh: calibrated wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits via Tycho-2
Single-image forced-photometry magnitude calibration plot for wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits:

Forced-photometry filter: calibrated wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits -> calib.txt_param_ref_wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits (aperture=6.2) ____ End of magnitude calibration ____ Applying consolidated magnitude filters... Preparing the exclusion lists for this field Done with filtering Found 3 candidate transients before the final filtering. (Hard limit: 10000) Median FWHM seeing for isolated stars: 2.3 pix Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits 2.3 pix Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits 2.3 pix fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits 2.3 pix fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits 2.3 pix wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits 2.3 pix wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits Limiting magnitude estimates: 15.4 mag. Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits 15.4 mag. Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits 15.1 mag. fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits 15.1 mag. fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits All-image limiting magnitude estimate: 15.1 (SNR ) 12.2 (80% of stars) with default.sex.telephoto_lens_onlybrightstars_v1 The first estimate is the magnitude of a star detected with a signal-to-noise ratio of following Karpov (2025, Acta Polytechnica, 65, 50). This value should be representative of the faintest stars clearly visible in the image. The brighter of the limiting magnitude estimates for the two second-epoch images is reported here. The second estimate is the 80th percentile of the magnitude distribution of stars detected on all four images. This value is representative of the faintest object that may enter the candidate transients list. The hard cut-off for the candidate transients is 15.5 mag. Waiting for UCAC5 plate solver wait ############ /tmp/tmp.CWbzuqaOA1 (6) ############ Parsing command line arguments... The guess is based on the existing WCS header. Trying to blindly solve the plate (local solve-field or remote server)... /data_ssd/NMW-TexasTech/workdir/vast_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits 571.0 Entering WCS image calibration mode. ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits verification OK: /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits It's a known telescope with plate solutions that are supposed to be good. The input image /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits has a WCS header - will blindly trust it is good... '/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits' -> 'wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits' FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits WCS_IMAGE_NAME=wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits WCS-calibrated image found: wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits Checking if the catalog wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat corresponding to the image wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits alredy exist and is non-empty... Catalog wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat corresponding to the image wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits found. The catalog is in the new format, as expected. The plate-solved (WCS-calibrated) image is saved to wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits WCS catalog name: wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat Excluding image region: -1.0 -1.0 1.0 1.0 (defined in bad_region.lst) Excluding image region: 7500.0 0.0 9576.0 6388.0 (defined in bad_region.lst) Excluding image region: 1122.0 1550.0 1124.0 1552.0 (defined in bad_region.lst) Excluding image region: 1637.0 2824.0 1639.0 2826.0 (defined in bad_region.lst) Excluding image region: 1831.0 2839.0 1833.0 2841.0 (defined in bad_region.lst) Excluding image region: 1905.0 4570.0 1907.0 4572.0 (defined in bad_region.lst) Excluding image region: 2012.0 4693.0 2014.0 4695.0 (defined in bad_region.lst) Excluding image region: 2397.0 4241.0 2399.0 4243.0 (defined in bad_region.lst) Excluding image region: 2679.0 2807.0 2681.0 2809.0 (defined in bad_region.lst) Excluding more image regions!.. (will not print them all) Excluded a total of 31 image regions (defined in bad_region.lst). SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=0, blended=703, bad_region=3443, passed=12417 Got 12417 stars (including 8446 good ones) from the SExtractor catalog wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat util/solve_plate_with_UCAC5 got 12417 stars from the SExtractor catalog Updated FoV from the plate-solved image: 937.1' Seting catalog search parameters based on the expected field of view 937.1 arcmin UCAC5 catalog search parameters: catalog_search_parameters->search_radius_deg= 0.013015 (46.9 arcsec) catalog_search_parameters->brightest_mag= 1.00 catalog_search_parameters->faintest_mag= 13.50 catalog_search_parameters->search_radius_second_step_deg 0.010412 (37.5 arcsec) ITERATION 01 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 Reading UCAC5 zone files... Searching UCAC5 zones 729 to 788 (Dec 55.9 to 67.3) Done reading UCAC5 zone files... Matched 968 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Correcting the measured astrometric positions... Accuracy estimation diagnostic: 968 matched stars entering correct_measured_positions(), 965 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.36" Removing outliers... Correcting the measured astrometric positions... Accuracy estimation diagnostic: 968 matched stars entering correct_measured_positions(), 9194 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.35" ITERATION 02 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 Reading UCAC5 zone files... Searching UCAC5 zones 729 to 788 (Dec 55.9 to 67.3) Done reading UCAC5 zone files... Matched 968 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Accuracy estimation diagnostic: 968 matched stars entering correct_measured_positions(), 9195 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.35" Accuracy estimation diagnostic: 968 matched stars entering correct_measured_positions(), 9195 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.37" Excluding outliers - 968 stars left (next iteration limit 1064) Stop iterations. The field is successfully solved and matched with the astrometric catalog! :) WCS_QUALITY_DIAG: file=Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits N_match=968 sigma_overall_arcsec=0.368 sigma_q1_arcsec=0.302 sigma_q2_arcsec=0.393 sigma_q3_arcsec=0.367 sigma_q4_arcsec=0.446 n_q1=284 n_q2=204 n_q3=284 n_q4=196 worst_quadrant_to_overall_ratio=1.212 The image catalog is written to wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat.ucac5 The DS9 region file with the matched stars is written to wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat.ds9.reg You may view it with the command: ds9 /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits -region wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat.ds9.reg The astrometric residuals vector field is written to wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat.astrometric_residuals Option '-n' not using photometric catalogs, just stick with astrometry opt '-i': 2 is the maximum number of iterations ############ /tmp/tmp.YP5kjdxU58 (6) ############ Parsing command line arguments... The guess is based on the existing WCS header. Trying to blindly solve the plate (local solve-field or remote server)... /data_ssd/NMW-TexasTech/workdir/vast_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits 571.0 Entering WCS image calibration mode. ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits verification OK: /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits It's a known telescope with plate solutions that are supposed to be good. The input image /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits has a WCS header - will blindly trust it is good... '/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits' -> 'wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits' FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits WCS_IMAGE_NAME=wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits WCS-calibrated image found: wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits Checking if the catalog wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits.wcscat corresponding to the image wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits alredy exist and is non-empty... Catalog wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits.wcscat corresponding to the image wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits found. The catalog is in the new format, as expected. The plate-solved (WCS-calibrated) image is saved to wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits WCS catalog name: wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits.wcscat Excluding image region: -1.0 -1.0 1.0 1.0 (defined in bad_region.lst) Excluding image region: 7500.0 0.0 9576.0 6388.0 (defined in bad_region.lst) Excluding image region: 1122.0 1550.0 1124.0 1552.0 (defined in bad_region.lst) Excluding image region: 1637.0 2824.0 1639.0 2826.0 (defined in bad_region.lst) Excluding image region: 1831.0 2839.0 1833.0 2841.0 (defined in bad_region.lst) Excluding image region: 1905.0 4570.0 1907.0 4572.0 (defined in bad_region.lst) Excluding image region: 2012.0 4693.0 2014.0 4695.0 (defined in bad_region.lst) Excluding image region: 2397.0 4241.0 2399.0 4243.0 (defined in bad_region.lst) Excluding image region: 2679.0 2807.0 2681.0 2809.0 (defined in bad_region.lst) Excluding more image regions!.. (will not print them all) Excluded a total of 31 image regions (defined in bad_region.lst). SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=0, blended=723, bad_region=3456, passed=12355 Got 12355 stars (including 8362 good ones) from the SExtractor catalog wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits.wcscat util/solve_plate_with_UCAC5 got 12355 stars from the SExtractor catalog Updated FoV from the plate-solved image: 937.1' Seting catalog search parameters based on the expected field of view 937.1 arcmin UCAC5 catalog search parameters: catalog_search_parameters->search_radius_deg= 0.013015 (46.9 arcsec) catalog_search_parameters->brightest_mag= 1.00 catalog_search_parameters->faintest_mag= 13.50 catalog_search_parameters->search_radius_second_step_deg 0.010412 (37.5 arcsec) ITERATION 01 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 Reading UCAC5 zone files... Searching UCAC5 zones 729 to 788 (Dec 55.9 to 67.3) Done reading UCAC5 zone files... Matched 969 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Correcting the measured astrometric positions... Accuracy estimation diagnostic: 969 matched stars entering correct_measured_positions(), 967 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.36" Removing outliers... Correcting the measured astrometric positions... Accuracy estimation diagnostic: 969 matched stars entering correct_measured_positions(), 9129 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.37" ITERATION 02 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 Reading UCAC5 zone files... Searching UCAC5 zones 729 to 788 (Dec 55.9 to 67.3) Done reading UCAC5 zone files... Matched 969 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Accuracy estimation diagnostic: 969 matched stars entering correct_measured_positions(), 9129 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.37" Accuracy estimation diagnostic: 969 matched stars entering correct_measured_positions(), 9129 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.39" Excluding outliers - 969 stars left (next iteration limit 1065) Stop iterations. The field is successfully solved and matched with the astrometric catalog! :) WCS_QUALITY_DIAG: file=Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits N_match=969 sigma_overall_arcsec=0.399 sigma_q1_arcsec=0.341 sigma_q2_arcsec=0.397 sigma_q3_arcsec=0.409 sigma_q4_arcsec=0.478 n_q1=286 n_q2=207 n_q3=281 n_q4=195 worst_quadrant_to_overall_ratio=1.198 The image catalog is written to wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits.wcscat.ucac5 The DS9 region file with the matched stars is written to wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits.wcscat.ds9.reg You may view it with the command: ds9 /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits -region wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits.wcscat.ds9.reg The astrometric residuals vector field is written to wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits.wcscat.astrometric_residuals Option '-n' not using photometric catalogs, just stick with astrometry opt '-i': 2 is the maximum number of iterations ############ /tmp/tmp.lSwyAsbgln (6) ############ Parsing command line arguments... The minor axis of the CCD chip should be 24.0 mm based on the derived pixel size of 3.8 um Internal estimated FoV 605.3' The guess is based on the FOCALLEN keyword. Trying to blindly solve the plate (local solve-field or remote server)... /data_ssd/NMW-TexasTech/workdir/vast_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits 605.0 Entering WCS image calibration mode. ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits verification OK: /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits It's not one of the telescopes that are know to produce images with good WCS solutions - will try to re-solve! FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits WCS_IMAGE_NAME=wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits WCS-calibrated image found: wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits Checking if the catalog wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits.wcscat corresponding to the image wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits alredy exist and is non-empty... Catalog wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits.wcscat corresponding to the image wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits found. The catalog is in the new format, as expected. The plate-solved (WCS-calibrated) image is saved to wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits WCS catalog name: wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits.wcscat Excluding image region: -1.0 -1.0 1.0 1.0 (defined in bad_region.lst) Excluding image region: 7500.0 0.0 9576.0 6388.0 (defined in bad_region.lst) Excluding image region: 1122.0 1550.0 1124.0 1552.0 (defined in bad_region.lst) Excluding image region: 1637.0 2824.0 1639.0 2826.0 (defined in bad_region.lst) Excluding image region: 1831.0 2839.0 1833.0 2841.0 (defined in bad_region.lst) Excluding image region: 1905.0 4570.0 1907.0 4572.0 (defined in bad_region.lst) Excluding image region: 2012.0 4693.0 2014.0 4695.0 (defined in bad_region.lst) Excluding image region: 2397.0 4241.0 2399.0 4243.0 (defined in bad_region.lst) Excluding image region: 2679.0 2807.0 2681.0 2809.0 (defined in bad_region.lst) Excluding more image regions!.. (will not print them all) Excluded a total of 31 image regions (defined in bad_region.lst). SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=0, blended=562, bad_region=1651, passed=9801 Got 9801 stars (including 7681 good ones) from the SExtractor catalog wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits.wcscat util/solve_plate_with_UCAC5 got 9801 stars from the SExtractor catalog Updated FoV from the plate-solved image: 937.1' Seting catalog search parameters based on the expected field of view 937.1 arcmin UCAC5 catalog search parameters: catalog_search_parameters->search_radius_deg= 0.013015 (46.9 arcsec) catalog_search_parameters->brightest_mag= 1.00 catalog_search_parameters->faintest_mag= 13.50 catalog_search_parameters->search_radius_second_step_deg 0.010412 (37.5 arcsec) ITERATION 01 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 Reading UCAC5 zone files... Searching UCAC5 zones 729 to 788 (Dec 56.0 to 67.2) Done reading UCAC5 zone files... Matched 967 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Correcting the measured astrometric positions... Accuracy estimation diagnostic: 967 matched stars entering correct_measured_positions(), 965 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.38" Removing outliers... Correcting the measured astrometric positions... Accuracy estimation diagnostic: 967 matched stars entering correct_measured_positions(), 8257 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.39" ITERATION 02 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 Reading UCAC5 zone files... Searching UCAC5 zones 729 to 788 (Dec 56.0 to 67.2) Done reading UCAC5 zone files... Matched 967 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Accuracy estimation diagnostic: 967 matched stars entering correct_measured_positions(), 8256 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.40" Accuracy estimation diagnostic: 967 matched stars entering correct_measured_positions(), 8256 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.43" Excluding outliers - 967 stars left (next iteration limit 1063) Stop iterations. The field is successfully solved and matched with the astrometric catalog! :) WCS_QUALITY_DIAG: file=fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits N_match=967 sigma_overall_arcsec=0.425 sigma_q1_arcsec=0.454 sigma_q2_arcsec=0.411 sigma_q3_arcsec=0.436 sigma_q4_arcsec=0.370 n_q1=329 n_q2=166 n_q3=296 n_q4=176 worst_quadrant_to_overall_ratio=1.067 The image catalog is written to wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits.wcscat.ucac5 The DS9 region file with the matched stars is written to wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits.wcscat.ds9.reg You may view it with the command: ds9 /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits -region wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits.wcscat.ds9.reg The astrometric residuals vector field is written to wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits.wcscat.astrometric_residuals Option '-n' not using photometric catalogs, just stick with astrometry opt '-i': 2 is the maximum number of iterations ############ /tmp/tmp.pbw6w0epnU (6) ############ Parsing command line arguments... The minor axis of the CCD chip should be 24.0 mm based on the derived pixel size of 3.8 um Internal estimated FoV 605.3' The guess is based on the FOCALLEN keyword. Trying to blindly solve the plate (local solve-field or remote server)... /data_ssd/NMW-TexasTech/workdir/vast_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits 605.0 Entering WCS image calibration mode. ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits verification OK: /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits It's not one of the telescopes that are know to produce images with good WCS solutions - will try to re-solve! FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits WCS_IMAGE_NAME=wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits WCS-calibrated image found: wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits Checking if the catalog wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits.wcscat corresponding to the image wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits alredy exist and is non-empty... Catalog wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits.wcscat corresponding to the image wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits found. The catalog is in the new format, as expected. The plate-solved (WCS-calibrated) image is saved to wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits WCS catalog name: wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits.wcscat Excluding image region: -1.0 -1.0 1.0 1.0 (defined in bad_region.lst) Excluding image region: 7500.0 0.0 9576.0 6388.0 (defined in bad_region.lst) Excluding image region: 1122.0 1550.0 1124.0 1552.0 (defined in bad_region.lst) Excluding image region: 1637.0 2824.0 1639.0 2826.0 (defined in bad_region.lst) Excluding image region: 1831.0 2839.0 1833.0 2841.0 (defined in bad_region.lst) Excluding image region: 1905.0 4570.0 1907.0 4572.0 (defined in bad_region.lst) Excluding image region: 2012.0 4693.0 2014.0 4695.0 (defined in bad_region.lst) Excluding image region: 2397.0 4241.0 2399.0 4243.0 (defined in bad_region.lst) Excluding image region: 2679.0 2807.0 2681.0 2809.0 (defined in bad_region.lst) Excluding more image regions!.. (will not print them all) Excluded a total of 31 image regions (defined in bad_region.lst). SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=0, blended=586, bad_region=1671, passed=9821 Got 9821 stars (including 7670 good ones) from the SExtractor catalog wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits.wcscat util/solve_plate_with_UCAC5 got 9821 stars from the SExtractor catalog Updated FoV from the plate-solved image: 937.1' Seting catalog search parameters based on the expected field of view 937.1 arcmin UCAC5 catalog search parameters: catalog_search_parameters->search_radius_deg= 0.013015 (46.9 arcsec) catalog_search_parameters->brightest_mag= 1.00 catalog_search_parameters->faintest_mag= 13.50 catalog_search_parameters->search_radius_second_step_deg 0.010412 (37.5 arcsec) ITERATION 01 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 Reading UCAC5 zone files... Searching UCAC5 zones 729 to 788 (Dec 56.0 to 67.2) Done reading UCAC5 zone files... Matched 968 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Correcting the measured astrometric positions... Accuracy estimation diagnostic: 968 matched stars entering correct_measured_positions(), 965 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.39" Removing outliers... Correcting the measured astrometric positions... Accuracy estimation diagnostic: 968 matched stars entering correct_measured_positions(), 8240 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.40" ITERATION 02 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 Reading UCAC5 zone files... Searching UCAC5 zones 729 to 788 (Dec 56.0 to 67.2) Done reading UCAC5 zone files... Matched 968 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Accuracy estimation diagnostic: 967 matched stars entering correct_measured_positions(), 8241 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.40" Accuracy estimation diagnostic: 967 matched stars entering correct_measured_positions(), 8241 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.43" Excluding outliers - 967 stars left (next iteration limit 1064) Stop iterations. The field is successfully solved and matched with the astrometric catalog! :) WCS_QUALITY_DIAG: file=fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits N_match=967 sigma_overall_arcsec=0.422 sigma_q1_arcsec=0.439 sigma_q2_arcsec=0.423 sigma_q3_arcsec=0.430 sigma_q4_arcsec=0.392 n_q1=330 n_q2=161 n_q3=303 n_q4=173 worst_quadrant_to_overall_ratio=1.040 The image catalog is written to wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits.wcscat.ucac5 The DS9 region file with the matched stars is written to wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits.wcscat.ds9.reg You may view it with the command: ds9 /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits -region wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits.wcscat.ds9.reg The astrometric residuals vector field is written to wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits.wcscat.astrometric_residuals Option '-n' not using photometric catalogs, just stick with astrometry opt '-i': 2 is the maximum number of iterations ################################### # Pre-local-correction WCS quality summary (see WCS_QUALITY_DIAG lines above) ref1=Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits sigma_overall=0.368 worst_q_ratio=1.212 ref2=Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits sigma_overall=0.399 worst_q_ratio=1.198 new1=fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits sigma_overall=0.425 worst_q_ratio=1.067 new2=fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits sigma_overall=0.422 worst_q_ratio=1.040 reference average sigma_overall=0.3835 worst_q_ratio=1.205 warn-on-ratio threshold: 2.0x reference ###################################
Astrometric residual vector field (catalog-matched stars):
plot_astrometric_residuals_xy.py: wrote wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302_astrometric_residuals.png (968 matched stars from wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat.astrometric_residuals, image 9576x6388, median residual 0.33 arcsec)
plot_astrometric_residuals_xy.py: wrote wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303_astrometric_residuals.png (969 matched stars from wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits.wcscat.astrometric_residuals, image 9576x6388, median residual 0.34 arcsec)
plot_astrometric_residuals_xy.py: wrote wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312_astrometric_residuals.png (967 matched stars from wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits.wcscat.astrometric_residuals, image 9576x6388, median residual 0.38 arcsec)
plot_astrometric_residuals_xy.py: wrote wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313_astrometric_residuals.png (967 matched stars from wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits.wcscat.astrometric_residuals, image 9576x6388, median residual 0.38 arcsec)
Copying WCS-calibrated images back to input directory Saving fully-calibrated image wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits INFO: FPACK_FULLY_CALIBRATED_IMAGE=no (not compressing the image) 'wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits' -> '/data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits' Saving fully-calibrated image wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits INFO: FPACK_FULLY_CALIBRATED_IMAGE=no (not compressing the image) 'wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits' -> '/data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits' Preparing the HTML report for the field Dra-07-Q2b1x1 with default.sex.telephoto_lens_onlybrightstars_v1 Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 17:39:28.85 +62:13:18.0: 11.54 +/- 0.01 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 16:50:05.44 +59:12:20.0: 12.47 +/- 0.01 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 17:39:28.85 +62:13:18.0: 11.54 +/- 0.01 detection Forced photometry reference-image weighted average: 11.54 +/- 0.00 Forced photometry filter REJECTED candidate at 17:39:28.85 +62:13:18.0: ref_mag=11.54 +/- 0.00 new_mean_mag=11.9606 delta=-0.42 (need > 0.90) Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 16:50:05.44 +59:12:20.0: 12.46 +/- 0.01 detection Forced photometry reference-image weighted average: 12.46 +/- 0.01 Forced photometry filter REJECTED candidate at 16:50:05.44 +59:12:20.0: ref_mag=12.46 +/- 0.01 new_mean_mag=12.4827 delta=-0.02 (need > 0.90) make_report_in_HTML.sh Phase 1 (network queries): 2s Pre-generating preview images in parallel... Done pre-generating preview images. Pre-generating finding charts in parallel... Done pre-generating finding charts. make_report_in_HTML.sh Pre-generation: 1s xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 20363_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 20363_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 1   2026 07 23.33444    2461244.83444    11.96    17:39:28.84 +62:13:18.5   2619 2912   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits Discovery image 2   2026 07 23.33491    2461244.83491    11.96    17:39:28.87 +62:13:17.5   2616 2913   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 20364_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 20364_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 2   2026 07 23.33491    2461244.83491    11.46    17:20:28.27 +57:53:06.0   3814 5656   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits **** FOUND 17:20:28.26 +57:53:06.1 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 22869_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 22869_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 1   2026 07 23.33444    2461244.83444    12.49    16:50:05.46 +59:12:20.0   6212 4842   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits Discovery image 2   2026 07 23.33491    2461244.83491    12.47    16:50:05.42 +59:12:20.1   6209 4842   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits make_report_in_HTML.sh Phase 2 (HTML assembly): 0s make_report_in_HTML.sh TOTAL: 3s Prepared the HTML report for the field Dra-07-Q2b1x1 with default.sex.telephoto_lens_onlybrightstars_v1 *------ done with default.sex.telephoto_lens_onlybrightstars_v1 ------* #### The local exclusion list is exclusion_list_local.txt #### wait *------ default.sex.telephoto_lens_vSTL ------* 'default.sex.telephoto_lens_vSTL' -> 'default.sex' Starting VaST with default.sex.telephoto_lens_vSTL ./vast --noflagimage --starmatchraius 5 --matchstarnumber 500 --selectbestaperture --sysrem 0 --type 4 --maxsextractorflag 99 --UTC --nofind --nojdkeyword /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits SExtractor catalog cache: saved Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.cat to cache SExtractor catalog cache: saved Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits.cat to cache VaST run complete with default.sex.telephoto_lens_vSTL The four input images were /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits Checking WCS cache directory local_wcs_cache Found WCS cache directory local_wcs_cache Creating symlink local_wcs_cache/wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits Creating symlink local_wcs_cache/wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits Creating symlink local_wcs_cache/wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits Creating symlink local_wcs_cache/wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits Creating symlink local_wcs_cache/exclusion_list.txt Checking WCS cache directory /mnt/usb/NMW_NG/solved_reference_images Found WCS cache directory /mnt/usb/NMW_NG/solved_reference_images Checking WCS cache directory /home/NMW_web_upload/solved_reference_images Checking WCS cache directory /dataX/kirx/NMW_NG_rt3_autumn2019/solved_reference_images Plate-solving the images wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits exists and is non-empty wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits exists and is non-empty wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits exists and is non-empty wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits exists and is non-empty ################################### # fov_of_wcs_calibrated_image.sh output for wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits (1st reference image) verification OK: wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits Image size: 937.1'x624.0' 15.6(deg)x10.4(deg) 9576x6388 pix Image scale: 5.87"/pix along the X axis and 5.86"/pix along the Y axis Image center: 17:08:34.611 +61:59:42.08 J2000 4789.000 3195.000 ################################### The image scale is 5.87"/pix, setting the soft and hard astrometric limits for filtering second-epoch detections: 5.9" and 8.8" ################################### # fov_of_wcs_calibrated_image.sh output for wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits (1st new image) verification OK: wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits Image size: 937.1'x624.0' 15.6(deg)x10.4(deg) 9576x6388 pix Image scale: 5.87"/pix along the X axis and 5.86"/pix along the Y axis Image center: 17:08:36.853 +61:59:33.67 J2000 4789.000 3195.000 ################################### ################################### # Check the image center offset between the reference and the first second-epoch image (pointing accuracy) Reference image center 17:08:34.611 +61:59:42.08 Second-epoch image center 17:08:36.853 +61:59:33.67 Angular distance between the image centers 0.0050 deg. Soft limit: 0.50 deg. Hard limit: 1.00 deg. ################################### ################################### # fov_of_wcs_calibrated_image.sh output for wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits (2nd new image) verification OK: wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits Image size: 937.1'x624.0' 15.6(deg)x10.4(deg) 9576x6388 pix Image scale: 5.87"/pix along the X axis and 5.86"/pix along the Y axis Image center: 17:08:34.117 +61:59:37.00 J2000 4789.000 3195.000 ################################### ################################### # Check the image center offset between the reference and the second second-epoch image (pointing accuracy) Reference image center 17:08:34.611 +61:59:42.08 Second-epoch image center 17:08:34.117 +61:59:37.00 Angular distance between the image centers 0.0017 deg. ################################### ################################### # Check the image center offset between the first and the second second-epoch image (shift should be applied between the second-epoch images) Second-epoch first image center 17:08:36.853 +61:59:33.67 Second-epoch second image center 17:08:34.117 +61:59:37.00 Angular distance between the image centers 0.00543 deg. ################################### Running solve_plate_with_UCAC5... Preparing for a parallel run Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits &> /tmp/tmp.idVER4PvfB Parallel run for /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits &> /tmp/tmp.yLJ9zPHbIW Parallel run for /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits &> /tmp/tmp.1an9STHYBY Parallel run for /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits &> /tmp/tmp.YFJMTdwnVz Parallel run for /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits Calibrating the magnitude scale Found non-empty wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits ____ Start of magnitude calibration ____ PHOTOMETRIC_CALIBRATION=TYCHO2_V Calibrating the magnitude scale with Tycho-2 stars util/transients/transient_factory_test31.sh is checking for the presence of non-empty wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits and wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat wait (drain background util/solve_plate_with_UCAC5 jobs before Tycho-2 calibration -- avoids wcs_.fits write race) Tycho-2 catalog is found at lib/catalogs/tycho2 Tycho-2 catalog and the derived bright star exclusion list are ready Checking for the presence of non-empty wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits and wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat Found non-empty wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits and wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat The reference image (wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits) and catalog (wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat) found 'wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat' -> 'wcsmag.cat' Read 63914 stars from the SExtractor catalog wcsmag.cat Detected star coordinate range: RA 237.8607 to 276.6327 deg, Dec +55.8792 to +67.2592 deg Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.00 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.01 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.02 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.03 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.04 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.05 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.06 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.07 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.08 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.09 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.10 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.11 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.12 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.13 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.14 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.15 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.16 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.17 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.18 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.19 Tycho-2 catalog search boundaries: RA 237.8607 to 276.6327 deg, Dec 55.8792 to 67.2592 deg Loaded 9293 Tycho-2 stars within the image boundaries (VT and BT non-zero). Relation between the catalog and instrumental magnitudes is written to calib.txt Stars used for magnitude calibration (good matches): 5638 out of 6334 total matches. Matched with Tycho-2 6334 out of 63914 detected stars. The calibration function type and coefficients are written to calib.txt_param util/calibrate_magnitude_scale 0.000000 1.000000 22.653550 a=0.000000 b=1.000000 c=22.653550 From vast_summary.log: estimated ref. image limiting mag.: -7.08 Updating vast_summary.log: Estimated ref. image limiting mag.: 15.57 Updated vast_limiting_magnitude.log with calibrated magnitudes Working... Please, PLEASE, be patient!!! All lightcurves processed! =) Estimated ref. image limiting mag.: 15.57
Lightcurve magnitude calibration plot:

Preparing per-reference-image forced-photometry calibration (method=tycho2 band=V) Read 63914 stars from the SExtractor catalog wcsmag.cat Detected star coordinate range: RA 237.8607 to 276.6327 deg, Dec +55.8792 to +67.2592 deg Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.00 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.01 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.02 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.03 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.04 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.05 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.06 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.07 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.08 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.09 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.10 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.11 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.12 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.13 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.14 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.15 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.16 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.17 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.18 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.19 Tycho-2 catalog search boundaries: RA 237.8607 to 276.6327 deg, Dec 55.8792 to 67.2592 deg Loaded 9293 Tycho-2 stars within the image boundaries (VT and BT non-zero). Relation between the catalog and instrumental magnitudes is written to calib.txt Stars used for magnitude calibration (good matches): 5638 out of 6334 total matches. Matched with Tycho-2 6334 out of 63914 detected stars. util/calibrate_single_image_with_tycho2.sh: calibrated wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits via Tycho-2
Single-image forced-photometry magnitude calibration plot for wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits:

Forced-photometry filter: calibrated wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits -> calib.txt_param_ref_wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits (aperture=4.9) Read 64100 stars from the SExtractor catalog wcsmag.cat Detected star coordinate range: RA 237.8607 to 276.6331 deg, Dec +55.8769 to +67.2570 deg Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.00 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.01 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.02 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.03 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.04 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.05 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.06 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.07 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.08 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.09 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.10 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.11 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.12 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.13 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.14 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.15 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.16 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.17 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.18 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.19 Tycho-2 catalog search boundaries: RA 237.8607 to 276.6331 deg, Dec 55.8769 to 67.2570 deg Loaded 9293 Tycho-2 stars within the image boundaries (VT and BT non-zero). Relation between the catalog and instrumental magnitudes is written to calib.txt Stars used for magnitude calibration (good matches): 5609 out of 6336 total matches. Matched with Tycho-2 6336 out of 64100 detected stars. util/calibrate_single_image_with_tycho2.sh: calibrated wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits via Tycho-2
Single-image forced-photometry magnitude calibration plot for wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits:

Forced-photometry filter: calibrated wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits -> calib.txt_param_ref_wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits (aperture=4.9) ____ End of magnitude calibration ____ Applying consolidated magnitude filters... Preparing the exclusion lists for this field Done with filtering Found 46 candidate transients before the final filtering. (Hard limit: 10000) Median FWHM seeing for isolated stars: 2.2 pix Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits 2.2 pix Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits 2.2 pix fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits 2.2 pix fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits 2.2 pix wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits 2.2 pix wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits Limiting magnitude estimates: 15.6 mag. Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits 15.6 mag. Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits 15.2 mag. fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits 15.2 mag. fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits All-image limiting magnitude estimate: 15.2 (SNR ) 14.6 (80% of stars) with default.sex.telephoto_lens_vSTL The first estimate is the magnitude of a star detected with a signal-to-noise ratio of following Karpov (2025, Acta Polytechnica, 65, 50). This value should be representative of the faintest stars clearly visible in the image. The brighter of the limiting magnitude estimates for the two second-epoch images is reported here. The second estimate is the 80th percentile of the magnitude distribution of stars detected on all four images. This value is representative of the faintest object that may enter the candidate transients list. The hard cut-off for the candidate transients is 15.5 mag. Waiting for UCAC5 plate solver wait ############ /tmp/tmp.idVER4PvfB (6) ############ Parsing command line arguments... The guess is based on the existing WCS header. Trying to blindly solve the plate (local solve-field or remote server)... /data_ssd/NMW-TexasTech/workdir/vast_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits 571.0 Entering WCS image calibration mode. ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits verification OK: /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits It's a known telescope with plate solutions that are supposed to be good. The input image /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits has a WCS header - will blindly trust it is good... '/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits' -> 'wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits' FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits WCS_IMAGE_NAME=wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits WCS-calibrated image found: wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits Checking if the catalog wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat corresponding to the image wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits alredy exist and is non-empty... Catalog wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat corresponding to the image wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits found. The catalog is in the new format, as expected. The plate-solved (WCS-calibrated) image is saved to wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits WCS catalog name: wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat Excluding image region: -1.0 -1.0 1.0 1.0 (defined in bad_region.lst) Excluding image region: 7500.0 0.0 9576.0 6388.0 (defined in bad_region.lst) Excluding image region: 1122.0 1550.0 1124.0 1552.0 (defined in bad_region.lst) Excluding image region: 1637.0 2824.0 1639.0 2826.0 (defined in bad_region.lst) Excluding image region: 1831.0 2839.0 1833.0 2841.0 (defined in bad_region.lst) Excluding image region: 1905.0 4570.0 1907.0 4572.0 (defined in bad_region.lst) Excluding image region: 2012.0 4693.0 2014.0 4695.0 (defined in bad_region.lst) Excluding image region: 2397.0 4241.0 2399.0 4243.0 (defined in bad_region.lst) Excluding image region: 2679.0 2807.0 2681.0 2809.0 (defined in bad_region.lst) Excluding more image regions!.. (will not print them all) Excluded a total of 31 image regions (defined in bad_region.lst). SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=12, blended=4104, bad_region=13153, passed=63902 Got 63902 stars (including 48022 good ones) from the SExtractor catalog wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat util/solve_plate_with_UCAC5 got 63902 stars from the SExtractor catalog Updated FoV from the plate-solved image: 937.1' Seting catalog search parameters based on the expected field of view 937.1 arcmin UCAC5 catalog search parameters: catalog_search_parameters->search_radius_deg= 0.013015 (46.9 arcsec) catalog_search_parameters->brightest_mag= 1.00 catalog_search_parameters->faintest_mag= 13.50 catalog_search_parameters->search_radius_second_step_deg 0.010412 (37.5 arcsec) ITERATION 01 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 Reading UCAC5 zone files... Searching UCAC5 zones 729 to 788 (Dec 55.9 to 67.3) Done reading UCAC5 zone files... Matched 972 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Correcting the measured astrometric positions... Accuracy estimation diagnostic: 972 matched stars entering correct_measured_positions(), 966 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.38" Removing outliers... Correcting the measured astrometric positions... Accuracy estimation diagnostic: 972 matched stars entering correct_measured_positions(), 51807 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.38" ITERATION 02 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 Reading UCAC5 zone files... Searching UCAC5 zones 729 to 788 (Dec 55.9 to 67.3) Done reading UCAC5 zone files... Matched 972 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Accuracy estimation diagnostic: 972 matched stars entering correct_measured_positions(), 51807 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.38" Accuracy estimation diagnostic: 972 matched stars entering correct_measured_positions(), 51807 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.40" Excluding outliers - 972 stars left (next iteration limit 1069) Stop iterations. The field is successfully solved and matched with the astrometric catalog! :) WCS_QUALITY_DIAG: file=Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits N_match=972 sigma_overall_arcsec=0.389 sigma_q1_arcsec=0.328 sigma_q2_arcsec=0.457 sigma_q3_arcsec=0.383 sigma_q4_arcsec=0.430 n_q1=291 n_q2=200 n_q3=289 n_q4=192 worst_quadrant_to_overall_ratio=1.175 The image catalog is written to wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat.ucac5 The DS9 region file with the matched stars is written to wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat.ds9.reg You may view it with the command: ds9 /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits -region wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat.ds9.reg The astrometric residuals vector field is written to wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat.astrometric_residuals Option '-n' not using photometric catalogs, just stick with astrometry opt '-i': 2 is the maximum number of iterations ############ /tmp/tmp.yLJ9zPHbIW (6) ############ Parsing command line arguments... The guess is based on the existing WCS header. Trying to blindly solve the plate (local solve-field or remote server)... /data_ssd/NMW-TexasTech/workdir/vast_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits 571.0 Entering WCS image calibration mode. ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits verification OK: /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits It's a known telescope with plate solutions that are supposed to be good. The input image /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits has a WCS header - will blindly trust it is good... '/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits' -> 'wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits' FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits WCS_IMAGE_NAME=wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits WCS-calibrated image found: wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits Checking if the catalog wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits.wcscat corresponding to the image wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits alredy exist and is non-empty... Catalog wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits.wcscat corresponding to the image wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits found. The catalog is in the new format, as expected. The plate-solved (WCS-calibrated) image is saved to wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits WCS catalog name: wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits.wcscat Excluding image region: -1.0 -1.0 1.0 1.0 (defined in bad_region.lst) Excluding image region: 7500.0 0.0 9576.0 6388.0 (defined in bad_region.lst) Excluding image region: 1122.0 1550.0 1124.0 1552.0 (defined in bad_region.lst) Excluding image region: 1637.0 2824.0 1639.0 2826.0 (defined in bad_region.lst) Excluding image region: 1831.0 2839.0 1833.0 2841.0 (defined in bad_region.lst) Excluding image region: 1905.0 4570.0 1907.0 4572.0 (defined in bad_region.lst) Excluding image region: 2012.0 4693.0 2014.0 4695.0 (defined in bad_region.lst) Excluding image region: 2397.0 4241.0 2399.0 4243.0 (defined in bad_region.lst) Excluding image region: 2679.0 2807.0 2681.0 2809.0 (defined in bad_region.lst) Excluding more image regions!.. (will not print them all) Excluded a total of 31 image regions (defined in bad_region.lst). SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=23, blended=4098, bad_region=13223, passed=64077 Got 64077 stars (including 48131 good ones) from the SExtractor catalog wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits.wcscat util/solve_plate_with_UCAC5 got 64077 stars from the SExtractor catalog Updated FoV from the plate-solved image: 937.1' Seting catalog search parameters based on the expected field of view 937.1 arcmin UCAC5 catalog search parameters: catalog_search_parameters->search_radius_deg= 0.013015 (46.9 arcsec) catalog_search_parameters->brightest_mag= 1.00 catalog_search_parameters->faintest_mag= 13.50 catalog_search_parameters->search_radius_second_step_deg 0.010412 (37.5 arcsec) ITERATION 01 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 Reading UCAC5 zone files... Searching UCAC5 zones 729 to 788 (Dec 55.9 to 67.3) Done reading UCAC5 zone files... Matched 974 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Correcting the measured astrometric positions... Accuracy estimation diagnostic: 974 matched stars entering correct_measured_positions(), 969 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.38" Removing outliers... Correcting the measured astrometric positions... Accuracy estimation diagnostic: 974 matched stars entering correct_measured_positions(), 51929 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.38" ITERATION 02 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 Reading UCAC5 zone files... Searching UCAC5 zones 729 to 788 (Dec 55.9 to 67.3) Done reading UCAC5 zone files... Matched 974 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Accuracy estimation diagnostic: 974 matched stars entering correct_measured_positions(), 51929 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.39" Accuracy estimation diagnostic: 974 matched stars entering correct_measured_positions(), 51928 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.42" Excluding outliers - 974 stars left (next iteration limit 1071) Stop iterations. The field is successfully solved and matched with the astrometric catalog! :) WCS_QUALITY_DIAG: file=Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits N_match=974 sigma_overall_arcsec=0.412 sigma_q1_arcsec=0.348 sigma_q2_arcsec=0.424 sigma_q3_arcsec=0.422 sigma_q4_arcsec=0.482 n_q1=291 n_q2=200 n_q3=289 n_q4=194 worst_quadrant_to_overall_ratio=1.170 The image catalog is written to wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits.wcscat.ucac5 The DS9 region file with the matched stars is written to wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits.wcscat.ds9.reg You may view it with the command: ds9 /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits -region wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits.wcscat.ds9.reg The astrometric residuals vector field is written to wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits.wcscat.astrometric_residuals Option '-n' not using photometric catalogs, just stick with astrometry opt '-i': 2 is the maximum number of iterations ############ /tmp/tmp.1an9STHYBY (6) ############ Parsing command line arguments... The minor axis of the CCD chip should be 24.0 mm based on the derived pixel size of 3.8 um Internal estimated FoV 605.3' The guess is based on the FOCALLEN keyword. Trying to blindly solve the plate (local solve-field or remote server)... /data_ssd/NMW-TexasTech/workdir/vast_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits 605.0 Entering WCS image calibration mode. ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits verification OK: /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits It's not one of the telescopes that are know to produce images with good WCS solutions - will try to re-solve! FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits WCS_IMAGE_NAME=wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits WCS-calibrated image found: wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits Checking if the catalog wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits.wcscat corresponding to the image wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits alredy exist and is non-empty... Catalog wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits.wcscat corresponding to the image wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits found. The catalog is in the new format, as expected. The plate-solved (WCS-calibrated) image is saved to wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits WCS catalog name: wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits.wcscat Excluding image region: -1.0 -1.0 1.0 1.0 (defined in bad_region.lst) Excluding image region: 7500.0 0.0 9576.0 6388.0 (defined in bad_region.lst) Excluding image region: 1122.0 1550.0 1124.0 1552.0 (defined in bad_region.lst) Excluding image region: 1637.0 2824.0 1639.0 2826.0 (defined in bad_region.lst) Excluding image region: 1831.0 2839.0 1833.0 2841.0 (defined in bad_region.lst) Excluding image region: 1905.0 4570.0 1907.0 4572.0 (defined in bad_region.lst) Excluding image region: 2012.0 4693.0 2014.0 4695.0 (defined in bad_region.lst) Excluding image region: 2397.0 4241.0 2399.0 4243.0 (defined in bad_region.lst) Excluding image region: 2679.0 2807.0 2681.0 2809.0 (defined in bad_region.lst) Excluding more image regions!.. (will not print them all) Excluded a total of 31 image regions (defined in bad_region.lst). SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=21, blended=3128, bad_region=6058, passed=53097 Got 53097 stars (including 44637 good ones) from the SExtractor catalog wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits.wcscat util/solve_plate_with_UCAC5 got 53097 stars from the SExtractor catalog Updated FoV from the plate-solved image: 937.1' Seting catalog search parameters based on the expected field of view 937.1 arcmin UCAC5 catalog search parameters: catalog_search_parameters->search_radius_deg= 0.013015 (46.9 arcsec) catalog_search_parameters->brightest_mag= 1.00 catalog_search_parameters->faintest_mag= 13.50 catalog_search_parameters->search_radius_second_step_deg 0.010412 (37.5 arcsec) ITERATION 01 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 Reading UCAC5 zone files... Searching UCAC5 zones 729 to 788 (Dec 55.9 to 67.3) Done reading UCAC5 zone files... Matched 970 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Correcting the measured astrometric positions... Accuracy estimation diagnostic: 970 matched stars entering correct_measured_positions(), 967 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.39" Removing outliers... Correcting the measured astrometric positions... Accuracy estimation diagnostic: 970 matched stars entering correct_measured_positions(), 47582 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.40" ITERATION 02 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 Reading UCAC5 zone files... Searching UCAC5 zones 729 to 788 (Dec 55.9 to 67.3) Done reading UCAC5 zone files... Matched 970 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Accuracy estimation diagnostic: 970 matched stars entering correct_measured_positions(), 47582 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.40" Accuracy estimation diagnostic: 970 matched stars entering correct_measured_positions(), 47582 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.45" Excluding outliers - 970 stars left (next iteration limit 1067) Stop iterations. The field is successfully solved and matched with the astrometric catalog! :) WCS_QUALITY_DIAG: file=fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits N_match=970 sigma_overall_arcsec=0.409 sigma_q1_arcsec=0.420 sigma_q2_arcsec=0.413 sigma_q3_arcsec=0.435 sigma_q4_arcsec=0.379 n_q1=327 n_q2=162 n_q3=308 n_q4=173 worst_quadrant_to_overall_ratio=1.063 The image catalog is written to wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits.wcscat.ucac5 The DS9 region file with the matched stars is written to wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits.wcscat.ds9.reg You may view it with the command: ds9 /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits -region wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits.wcscat.ds9.reg The astrometric residuals vector field is written to wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits.wcscat.astrometric_residuals Option '-n' not using photometric catalogs, just stick with astrometry opt '-i': 2 is the maximum number of iterations ############ /tmp/tmp.YFJMTdwnVz (6) ############ Parsing command line arguments... The minor axis of the CCD chip should be 24.0 mm based on the derived pixel size of 3.8 um Internal estimated FoV 605.3' The guess is based on the FOCALLEN keyword. Trying to blindly solve the plate (local solve-field or remote server)... /data_ssd/NMW-TexasTech/workdir/vast_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits 605.0 Entering WCS image calibration mode. ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits verification OK: /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits It's not one of the telescopes that are know to produce images with good WCS solutions - will try to re-solve! FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits WCS_IMAGE_NAME=wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits WCS-calibrated image found: wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits Checking if the catalog wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits.wcscat corresponding to the image wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits alredy exist and is non-empty... Catalog wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits.wcscat corresponding to the image wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits found. The catalog is in the new format, as expected. The plate-solved (WCS-calibrated) image is saved to wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits WCS catalog name: wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits.wcscat Excluding image region: -1.0 -1.0 1.0 1.0 (defined in bad_region.lst) Excluding image region: 7500.0 0.0 9576.0 6388.0 (defined in bad_region.lst) Excluding image region: 1122.0 1550.0 1124.0 1552.0 (defined in bad_region.lst) Excluding image region: 1637.0 2824.0 1639.0 2826.0 (defined in bad_region.lst) Excluding image region: 1831.0 2839.0 1833.0 2841.0 (defined in bad_region.lst) Excluding image region: 1905.0 4570.0 1907.0 4572.0 (defined in bad_region.lst) Excluding image region: 2012.0 4693.0 2014.0 4695.0 (defined in bad_region.lst) Excluding image region: 2397.0 4241.0 2399.0 4243.0 (defined in bad_region.lst) Excluding image region: 2679.0 2807.0 2681.0 2809.0 (defined in bad_region.lst) Excluding more image regions!.. (will not print them all) Excluded a total of 31 image regions (defined in bad_region.lst). SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=11, blended=3367, bad_region=6166, passed=53704 Got 53704 stars (including 45058 good ones) from the SExtractor catalog wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits.wcscat util/solve_plate_with_UCAC5 got 53704 stars from the SExtractor catalog Updated FoV from the plate-solved image: 937.1' Seting catalog search parameters based on the expected field of view 937.1 arcmin UCAC5 catalog search parameters: catalog_search_parameters->search_radius_deg= 0.013015 (46.9 arcsec) catalog_search_parameters->brightest_mag= 1.00 catalog_search_parameters->faintest_mag= 13.50 catalog_search_parameters->search_radius_second_step_deg 0.010412 (37.5 arcsec) ITERATION 01 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 Reading UCAC5 zone files... Searching UCAC5 zones 729 to 788 (Dec 55.9 to 67.3) Done reading UCAC5 zone files... Matched 970 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Correcting the measured astrometric positions... Accuracy estimation diagnostic: 970 matched stars entering correct_measured_positions(), 968 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.40" Removing outliers... Correcting the measured astrometric positions... Accuracy estimation diagnostic: 970 matched stars entering correct_measured_positions(), 48077 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.40" ITERATION 02 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 Reading UCAC5 zone files... Searching UCAC5 zones 729 to 788 (Dec 55.9 to 67.3) Done reading UCAC5 zone files... Matched 970 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Accuracy estimation diagnostic: 970 matched stars entering correct_measured_positions(), 48077 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.40" Accuracy estimation diagnostic: 970 matched stars entering correct_measured_positions(), 48077 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.44" Excluding outliers - 970 stars left (next iteration limit 1067) Stop iterations. The field is successfully solved and matched with the astrometric catalog! :) WCS_QUALITY_DIAG: file=fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits N_match=970 sigma_overall_arcsec=0.409 sigma_q1_arcsec=0.449 sigma_q2_arcsec=0.431 sigma_q3_arcsec=0.417 sigma_q4_arcsec=0.408 n_q1=333 n_q2=161 n_q3=304 n_q4=172 worst_quadrant_to_overall_ratio=1.099 The image catalog is written to wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits.wcscat.ucac5 The DS9 region file with the matched stars is written to wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits.wcscat.ds9.reg You may view it with the command: ds9 /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits -region wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits.wcscat.ds9.reg The astrometric residuals vector field is written to wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits.wcscat.astrometric_residuals Option '-n' not using photometric catalogs, just stick with astrometry opt '-i': 2 is the maximum number of iterations Skipping WCS quality comparison: not the first SExtractor pass (default.sex.telephoto_lens_vSTL) Copying WCS-calibrated images back to input directory Saving fully-calibrated image wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits INFO: FPACK_FULLY_CALIBRATED_IMAGE=no (not compressing the image) The destination file is already there - not rewriting /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits Saving fully-calibrated image wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits INFO: FPACK_FULLY_CALIBRATED_IMAGE=no (not compressing the image) The destination file is already there - not rewriting /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/wcs_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits Preparing the HTML report for the field Dra-07-Q2b1x1 with default.sex.telephoto_lens_vSTL Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 17:47:46.34 +64:34:17.4: 13.05 +/- 0.02 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 17:30:09.75 +60:21:21.9: 14.04 +/- 0.05 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 17:09:48.13 +65:15:46.9: 13.38 +/- 0.03 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 17:08:39.65 +59:38:44.3: 14.06 +/- 0.05 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 17:28:02.82 +64:14:17.2: 12.67 +/- 0.02 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 17:36:00.55 +64:20:46.2: 14.90 +/- 0.11 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 16:56:05.06 +60:34:47.6: 13.50 +/- 0.03 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 17:17:07.01 +60:41:29.9: 14.43 +/- 0.07 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 17:41:56.64 +59:06:31.1: 13.38 +/- 0.03 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 17:08:39.65 +59:38:44.3: 14.12 +/- 0.05 detection Forced photometry reference-image weighted average: 14.08 +/- 0.04 Forced photometry filter REJECTED candidate at 17:08:39.65 +59:38:44.3: ref_mag=14.08 +/- 0.04 new_mean_mag=14.3886 delta=-0.30 (need > 0.90) Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 17:17:07.01 +60:41:29.9: 14.72 +/- 0.09 detection Forced photometry reference-image weighted average: 14.54 +/- 0.05 Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 17:28:02.82 +64:14:17.2: 12.65 +/- 0.02 detection Forced photometry filter REJECTED candidate at 17:17:07.01 +60:41:29.9: ref_mag=14.54 +/- 0.05 new_mean_mag=14.8035 delta=-0.26 (need > 0.90) Forced photometry reference-image weighted average: 12.66 +/- 0.01 Forced photometry filter REJECTED candidate at 17:28:02.82 +64:14:17.2: ref_mag=12.66 +/- 0.01 new_mean_mag=13.0389 delta=-0.38 (need > 0.90) Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 17:47:46.34 +64:34:17.4: 13.19 +/- 0.02 detection Forced photometry reference-image weighted average: 13.11 +/- 0.02 Forced photometry filter REJECTED candidate at 17:47:46.34 +64:34:17.4: ref_mag=13.11 +/- 0.02 new_mean_mag=13.3646 delta=-0.25 (need > 0.90) Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 17:36:00.55 +64:20:46.2: 14.84 +/- 0.10 detection Forced photometry reference-image weighted average: 14.87 +/- 0.07 Forced photometry filter REJECTED candidate at 17:36:00.55 +64:20:46.2: ref_mag=14.87 +/- 0.07 new_mean_mag=14.9524 delta=-0.08 (need > 0.90) Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 17:30:09.75 +60:21:21.9: 14.10 +/- 0.05 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 17:45:49.15 +62:04:02.2: 12.03 +/- 0.01 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 17:41:56.64 +59:06:31.1: 13.34 +/- 0.03 detection Forced photometry reference-image weighted average: 14.07 +/- 0.04 Forced photometry reference-image weighted average: 13.36 +/- 0.02 Forced photometry filter REJECTED candidate at 17:41:56.64 +59:06:31.1: ref_mag=13.36 +/- 0.02 new_mean_mag=13.5214 delta=-0.16 (need > 0.90) Forced photometry filter REJECTED candidate at 17:30:09.75 +60:21:21.9: ref_mag=14.07 +/- 0.04 new_mean_mag=14.3786 delta=-0.31 (need > 0.90) Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 16:56:05.06 +60:34:47.6: 13.51 +/- 0.03 detection Forced photometry reference-image weighted average: 13.51 +/- 0.02 Forced photometry filter REJECTED candidate at 16:56:05.06 +60:34:47.6: ref_mag=13.51 +/- 0.02 new_mean_mag=13.5274 delta=-0.02 (need > 0.90) Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 17:09:48.13 +65:15:46.9: 13.46 +/- 0.03 detection Forced photometry reference-image weighted average: 13.41 +/- 0.02 Forced photometry filter REJECTED candidate at 17:09:48.13 +65:15:46.9: ref_mag=13.41 +/- 0.02 new_mean_mag=13.5889 delta=-0.18 (need > 0.90) Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 17:45:49.15 +62:04:02.2: 12.06 +/- 0.01 detection Forced photometry reference-image weighted average: 12.04 +/- 0.01 Forced photometry filter REJECTED candidate at 17:45:49.15 +62:04:02.2: ref_mag=12.04 +/- 0.01 new_mean_mag=12.4332 delta=-0.39 (need > 0.90) Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 16:32:44.14 +64:42:46.4: 13.97 +/- 0.05 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 16:36:00.43 +63:54:52.6: 13.86 +/- 0.05 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 17:45:45.24 +62:04:35.0: 14.76 +/- 0.10 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 17:25:35.66 +64:09:06.9: 14.84 +/- 0.11 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 16:32:44.14 +64:42:46.4: 13.97 +/- 0.06 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 17:35:32.74 +58:47:21.2: 14.88 +/- 0.12 detection Forced photometry reference-image weighted average: 13.97 +/- 0.04 Forced photometry filter REJECTED candidate at 16:32:44.14 +64:42:46.4: ref_mag=13.97 +/- 0.04 new_mean_mag=14.0127 delta=-0.04 (need > 0.90) Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 17:42:55.21 +64:06:07.9: 14.94 +/- 0.12 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 16:36:00.43 +63:54:52.6: 13.97 +/- 0.05 detection Forced photometry reference-image weighted average: 13.91 +/- 0.04 Forced photometry filter REJECTED candidate at 16:36:00.43 +63:54:52.6: ref_mag=13.91 +/- 0.04 new_mean_mag=14.0651 delta=-0.15 (need > 0.90) Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 17:28:21.97 +58:01:24.7: 15.21 +/- 0.15 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 17:32:44.42 +57:39:56.5: 15.64 +/- 0.23 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 17:45:45.24 +62:04:35.0: 14.68 +/- 0.09 detection Forced photometry reference-image weighted average: 14.72 +/- 0.07 Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 17:38:11.34 +63:38:55.7: 15.43 +/- 0.20 detection Forced photometry filter REJECTED candidate at 17:45:45.24 +62:04:35.0: ref_mag=14.72 +/- 0.07 new_mean_mag=14.6842 delta=0.03 (need > 0.90) Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 17:25:06.48 +63:59:03.9: 15.24 +/- 0.15 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 17:35:32.74 +58:47:21.2: 14.75 +/- 0.10 detection Forced photometry reference-image weighted average: 14.80 +/- 0.08 Forced photometry filter REJECTED candidate at 17:35:32.74 +58:47:21.2: ref_mag=14.80 +/- 0.08 new_mean_mag=14.7484 delta=0.06 (need > 0.90) Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 17:25:35.66 +64:09:06.9: 14.85 +/- 0.11 detection Forced photometry reference-image weighted average: 14.85 +/- 0.08 Forced photometry filter REJECTED candidate at 17:25:35.66 +64:09:06.9: ref_mag=14.85 +/- 0.08 new_mean_mag=14.7806 delta=0.06 (need > 0.90) Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 17:42:55.21 +64:06:07.9: 14.90 +/- 0.12 detection Forced photometry reference-image weighted average: 14.92 +/- 0.08 Forced photometry filter REJECTED candidate at 17:42:55.21 +64:06:07.9: ref_mag=14.92 +/- 0.08 new_mean_mag=14.9326 delta=-0.01 (need > 0.90) Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 17:28:21.97 +58:01:24.7: 15.09 +/- 0.13 detection Forced photometry reference-image weighted average: 15.14 +/- 0.10 Forced photometry filter REJECTED candidate at 17:28:21.97 +58:01:24.7: ref_mag=15.14 +/- 0.10 new_mean_mag=14.9920 delta=0.15 (need > 0.90) Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 17:32:44.42 +57:39:56.5: 15.41 +/- 0.20 detection Forced photometry reference-image weighted average: 15.51 +/- 0.15 Forced photometry filter REJECTED candidate at 17:32:44.42 +57:39:56.5: ref_mag=15.51 +/- 0.15 new_mean_mag=14.9512 delta=0.55 (need > 0.90) Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 17:38:11.34 +63:38:55.7: 15.57 +/- 0.22 detection Forced photometry reference-image weighted average: 15.50 +/- 0.15 Forced photometry filter REJECTED candidate at 17:38:11.34 +63:38:55.7: ref_mag=15.50 +/- 0.15 new_mean_mag=15.0502 delta=0.45 (need > 0.90) Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 17:25:06.48 +63:59:03.9: 15.21 +/- 0.14 detection Forced photometry reference-image weighted average: 15.23 +/- 0.10 Forced photometry filter REJECTED candidate at 17:25:06.48 +63:59:03.9: ref_mag=15.23 +/- 0.10 new_mean_mag=14.7706 delta=0.46 (need > 0.90) Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 17:37:54.74 +62:40:55.5: 15.45 +/- 0.18 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 17:38:23.78 +61:52:46.6: 15.46 +/- 0.19 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 17:41:16.14 +64:23:50.6: 15.38 +/- 0.18 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 17:37:54.74 +62:40:55.5: 15.06 +/- 0.13 detection Forced photometry reference-image weighted average: 15.19 +/- 0.11 Forced photometry filter REJECTED candidate at 17:37:54.74 +62:40:55.5: ref_mag=15.19 +/- 0.11 new_mean_mag=14.9482 delta=0.25 (need > 0.90) Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 17:38:23.78 +61:52:46.6: 15.15 +/- 0.14 detection Forced photometry reference-image weighted average: 15.26 +/- 0.11 Forced photometry filter REJECTED candidate at 17:38:23.78 +61:52:46.6: ref_mag=15.26 +/- 0.11 new_mean_mag=14.9750 delta=0.29 (need > 0.90) Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 17:41:16.14 +64:23:50.6: 15.61 +/- 0.22 detection Forced photometry reference-image weighted average: 15.48 +/- 0.14 Forced photometry filter REJECTED candidate at 17:41:16.14 +64:23:50.6: ref_mag=15.48 +/- 0.14 new_mean_mag=14.9129 delta=0.56 (need > 0.90) make_report_in_HTML.sh Phase 1 (network queries): 4s Pre-generating preview images in parallel... Done pre-generating preview images. Pre-generating finding charts in parallel... Done pre-generating finding charts. make_report_in_HTML.sh Pre-generation: 0s xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 77593_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 77593_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 1   2026 07 23.33444    2461244.83444    15.01    17:36:00.40 +64:20:47.5   3007 1662   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits Discovery image 2   2026 07 23.33491    2461244.83491    14.91    17:36:00.69 +64:20:45.0   3004 1663   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 77609_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 77609_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 1   2026 07 23.33444    2461244.83444    14.75    17:17:06.91 +60:41:30.8   4155 3967   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits Discovery image 2   2026 07 23.33491    2461244.83491    14.89    17:17:07.12 +60:41:29.0   4152 3968   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 77616_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 77616_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 2   2026 07 23.33491    2461244.83491    14.65    17:28:52.85 +57:59:15.9   3142 5550   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits **** FOUND 17:28:52.94 +57:59:16.4 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 77617_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 77617_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 1   2026 07 23.33444    2461244.83444    14.41    17:08:39.62 +59:38:44.3   4776 4614   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits Discovery image 2   2026 07 23.33491    2461244.83491    14.38    17:08:39.67 +59:38:44.3   4772 4615   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 77623_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 77623_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 1   2026 07 23.33444    2461244.83444    14.39    17:30:09.69 +60:21:21.5   3172 4108   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits Discovery image 2   2026 07 23.33491    2461244.83491    14.37    17:30:09.82 +60:21:22.2   3169 4108   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 77632_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 77632_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 1   2026 07 23.33444    2461244.83444    13.74    17:09:48.22 +65:15:46.7   4727 1215   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits Discovery image 2   2026 07 23.33491    2461244.83491    13.50    17:09:48.03 +65:15:47.2   4725 1215   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 77633_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 77633_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 1   2026 07 23.33444    2461244.83444    13.44    16:56:05.02 +60:34:47.8   5713 4033   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits Discovery image 2   2026 07 23.33491    2461244.83491    13.66    16:56:05.09 +60:34:47.4   5710 4034   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 77634_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 77634_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 1   2026 07 23.33444    2461244.83444    13.58    17:41:56.60 +59:06:31.4   2191 4762   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits Discovery image 2   2026 07 23.33491    2461244.83491    13.48    17:41:56.68 +59:06:30.8   2187 4762   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 77636_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 77636_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 1   2026 07 23.33444    2461244.83444    13.36    17:47:46.23 +64:34:18.2   2261 1420   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits Discovery image 2   2026 07 23.33491    2461244.83491    13.37    17:47:46.45 +64:34:16.5   2258 1420   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 77639_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 77639_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 1   2026 07 23.33444    2461244.83444    13.03    17:28:02.90 +64:14:16.4   3522 1779   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits Discovery image 2   2026 07 23.33491    2461244.83491    13.05    17:28:02.75 +64:14:18.0   3519 1780   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 77643_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 77643_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 1   2026 07 23.33444    2461244.83444    12.46    17:45:49.17 +62:04:02.2   2160 2943   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits Discovery image 2   2026 07 23.33491    2461244.83491    12.41    17:45:49.13 +62:04:02.3   2157 2943   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 77644_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 77644_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 2   2026 07 23.33491    2461244.83491    11.48    17:20:28.22 +57:53:05.6   3814 5657   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits **** FOUND 17:20:28.23 +57:53:05.9 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 78660_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 78660_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 2   2026 07 23.33491    2461244.83491    11.09    16:32:57.49 +64:28:29.2   7119 1546   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits Rejecting candidate due to large distance (18.8") between the two second-epoch detections xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79154_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 79154_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 2   2026 07 23.33491    2461244.83491    11.65    17:20:06.81 +63:35:42.9   4020 2204   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits Rejecting candidate due to large distance (18.9") between the two second-epoch detections xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79388_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 79388_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 2   2026 07 23.33491    2461244.83491    11.86    17:06:04.16 +59:20:21.5   4971 4801   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits Rejecting candidate due to large distance (20.3") between the two second-epoch detections xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 80667_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 80667_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 2   2026 07 23.33491    2461244.83491    12.78    17:38:31.33 +62:11:17.7   2681 2941   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits Rejecting candidate due to large distance (19.0") between the two second-epoch detections xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 81550_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 81550_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 2   2026 07 23.33491    2461244.83491    12.84    16:32:53.21 +62:50:42.6   7252 2526   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits **** FOUND 16:32:53.21 +62:50:42.8 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 81586_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 81586_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 2   2026 07 23.33491    2461244.83491    13.07    17:41:37.34 +65:44:19.4   2750 0776   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits Rejecting candidate due to large distance (18.1") between the two second-epoch detections xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 81671_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 81671_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 2   2026 07 23.33491    2461244.83491    13.13    17:42:31.56 +59:25:02.2   2168 4570   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits Rejecting candidate due to large distance (20.1") between the two second-epoch detections xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 81699_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 81699_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 2   2026 07 23.33491    2461244.83491    12.92    16:37:03.99 +59:06:41.0   7224 4812   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits Rejecting candidate due to large distance (20.3") between the two second-epoch detections xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 82479_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 82479_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 2   2026 07 23.33491    2461244.83491    13.20    16:48:42.67 +59:31:15.4   6302 4644   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits **** FOUND 16:48:42.72 +59:31:15.5 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 83193_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 83193_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 2   2026 07 23.33491    2461244.83491    13.15    16:41:16.39 +58:14:20.0   6950 5374   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits Rejecting candidate due to large distance (20.7") between the two second-epoch detections xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 83514_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 83514_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 2   2026 07 23.33491    2461244.83491    13.71    16:42:57.68 +59:36:41.9   6738 4555   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits Rejecting candidate due to large distance (20.3") between the two second-epoch detections xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 83646_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 83646_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 2   2026 07 23.33491    2461244.83491    13.51    16:45:14.27 +61:21:07.3   6476 3519   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits Rejecting candidate due to large distance (19.6") between the two second-epoch detections xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 84754_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 84754_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 2   2026 07 23.33491    2461244.83491    13.97    17:33:41.41 +57:34:27.5   2730 5766   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits **** FOUND 17:33:41.40 +57:34:26.8 in the exclusion list exclusion_list_bsc.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 85078_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 85078_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 2   2026 07 23.33491    2461244.83491    14.06    17:19:48.27 +58:27:10.6   3885 5314   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits Rejecting candidate due to large distance (20.6") between the two second-epoch detections xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 85234_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 85234_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 2   2026 07 23.33491    2461244.83491    13.89    16:38:07.59 +65:25:39.1   6719 1012   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits **** FOUND 16:38:07.56 +65:25:39.4 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 86394_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 86394_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 1   2026 07 23.33444    2461244.83444    13.91    16:32:44.21 +64:42:47.7   7118 1400   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits Discovery image 2   2026 07 23.33491    2461244.83491    14.16    16:32:44.07 +64:42:45.1   7115 1401   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 87130_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 87130_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 1   2026 07 23.33444    2461244.83444    14.07    16:36:00.37 +63:54:51.5   6964 1909   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits Discovery image 2   2026 07 23.33491    2461244.83491    14.05    16:36:00.50 +63:54:53.7   6961 1909   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 87727_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 87727_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 2   2026 07 23.33491    2461244.83491    14.49    17:34:45.93 +58:03:44.2   2675 5461   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits Rejecting candidate due to large distance (20.4") between the two second-epoch detections xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 87755_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 87755_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 2   2026 07 23.33491    2461244.83491    14.46    17:32:54.74 +59:25:18.0   2907 4653   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits Rejecting candidate due to large distance (19.9") between the two second-epoch detections xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 88336_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 88336_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 2   2026 07 23.33491    2461244.83491    14.69    17:48:44.55 +64:16:05.2   2166 1592   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits **** FOUND 17:48:44.42 +64:16:05.2 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 88833_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 88833_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 1   2026 07 23.33444    2461244.83444    14.65    17:45:45.36 +62:04:34.6   2165 2938   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits Discovery image 2   2026 07 23.33491    2461244.83491    14.75    17:45:45.12 +62:04:35.3   2163 2939   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 89239_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 89239_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 2   2026 07 23.33491    2461244.83491    14.32    16:58:34.40 +62:30:18.3   5488 2877   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits **** FOUND 16:58:34.39 +62:30:18.3 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 90359_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 90359_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 1   2026 07 23.33444    2461244.83444    14.79    17:35:33.03 +58:47:22.2   2665 5014   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits Discovery image 2   2026 07 23.33491    2461244.83491    14.72    17:35:32.45 +58:47:20.2   2662 5015   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 90468_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 90468_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 1   2026 07 23.33444    2461244.83444    14.71    17:25:35.70 +64:09:07.0   3679 1844   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits Discovery image 2   2026 07 23.33491    2461244.83491    14.88    17:25:35.62 +64:09:06.8   3676 1845   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 90589_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 90589_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 1   2026 07 23.33444    2461244.83444    14.87    17:32:44.22 +57:39:55.7   2817 5718   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits Discovery image 2   2026 07 23.33491    2461244.83491    15.11    17:32:44.62 +57:39:57.2   2813 5718   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 91112_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 91112_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 1   2026 07 23.33444    2461244.83444    14.87    17:42:55.24 +64:06:08.8   2535 1750   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits Discovery image 2   2026 07 23.33491    2461244.83491    15.01    17:42:55.18 +64:06:07.0   2532 1751   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 91320_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 91320_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 1   2026 07 23.33444    2461244.83444    14.93    17:28:21.98 +58:01:23.8   3189 5531   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits Discovery image 2   2026 07 23.33491    2461244.83491    15.07    17:28:21.95 +58:01:25.6   3185 5531   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 91717_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 91717_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 1   2026 07 23.33444    2461244.83444    15.05    17:38:11.25 +63:38:55.6   2814 2065   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits Discovery image 2   2026 07 23.33491    2461244.83491    15.05    17:38:11.43 +63:38:55.7   2811 2065   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 91802_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 91802_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 1   2026 07 23.33444    2461244.83444    14.91    17:25:06.75 +63:59:04.3   3704 1948   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits Discovery image 2   2026 07 23.33491    2461244.83491    14.69    17:25:06.22 +63:59:03.6   3701 1948   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 91813_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 91813_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 1   2026 07 23.33444    2461244.83444    14.96    17:37:54.61 +62:40:55.7   2763 2649   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits Discovery image 2   2026 07 23.33491    2461244.83491    14.94    17:37:54.88 +62:40:55.3   2760 2649   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 91950_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 91950_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 1   2026 07 23.33444    2461244.83444    15.03    17:38:23.89 +61:52:47.0   2670 3127   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits Discovery image 2   2026 07 23.33491    2461244.83491    14.93    17:38:23.68 +61:52:46.2   2667 3128   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 92038_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 92038_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 1   2026 07 23.33444    2461244.83444    15.01    17:41:16.26 +64:23:50.7   2668 1588   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-01-25_20.00sec_4.90C_LIGHT_0312.fits Discovery image 2   2026 07 23.33491    2461244.83491    14.86    17:41:16.01 +64:23:50.5   2665 1588   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 92448_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 92448_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 2   2026 07 23.33491    2461244.83491    14.87    16:40:29.33 +65:44:22.0   6552 0840   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits Rejecting candidate due to large distance (18.5") between the two second-epoch detections xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 34950_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 The candidate 34950_fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313 did not pass the final checks Discovery image 3   2026 07 23.33491    2461244.83491    11.36    17:29:24.12 +62:19:48.2   3330 2923   /data_ssd/NMW-TexasTech/workdir//img_2026-07-23_CI_Dra-07-Q2b1x1_033259_TTUQ2b1x1_1710338_A65EJy0F/fd_Dra-07-Q2b1x1_2026-07-23_03-02-05_20.00sec_4.90C_LIGHT_0313.fits Rejecting candidate due to large distance (19.3") between the two second-epoch detections make_report_in_HTML.sh Phase 2 (HTML assembly): 1s make_report_in_HTML.sh TOTAL: 5s Prepared the HTML report for the field Dra-07-Q2b1x1 with default.sex.telephoto_lens_vSTL *------ done with default.sex.telephoto_lens_vSTL ------* #### The local exclusion list is exclusion_list_local.txt #### ########### Completed Dra-07-Q2b1x1 ########### The analysis was running at tau We are allowed to update the exclusion list at tau host Found ../exclusion_list_TTUQ2.txt #### The exclusion list before filtering-out asteroids, bad pixels and adding Gaia sources #### ################################################################################### renamed 'exclusion_list_index_html.txt_noasteroids' -> 'exclusion_list_index_html.txt' renamed 'exclusion_list_index_html.txt_nohotpixels' -> 'exclusion_list_index_html.txt' # Count candidates with no identification (that also don't look like hot pix) Found 0 unidentified candidates (excluding asteroids, hot pixels and known variable stars). ################################################################################### 0 candidates found (excluding asteroids and hot pixels) This does not look like a test run ################################################################################### exclusion_list_gaiadr2.txt NOT FOUND exclusion_list_apass.txt NOT FOUND IS_THIS_TEST_RUN=NO ALLOW_EXCLUSION_LIST_UPDATE= YES #### Nothing to add to the exclusion list #### The observatory MPC code is V36 ############################################################ Positions of planets computed with util/planet_finder/main.py for JD(UT)2461244.83443836 -observatory V36 07:07:11.04 +18:20:21.0 Mercury (2.2mag) 11:04:01.87 +06:41:41.5 Venus (-4.2mag) 05:02:38.00 +22:45:29.0 Mars (1.3mag) 08:28:30.80 +19:32:40.4 Jupiter (-1.8mag) 00:56:45.25 +03:22:12.8 Saturn (0.7mag) 04:09:31.76 +20:51:11.4 Uranus (5.8mag) 00:16:48.06 +00:18:30.3 Neptune (7.7mag) 20:29:41.01 -23:23:40.9 Pluto (14.4mag) 15:05:32.45 -23:26:30.4 Moon (-10.9mag) -rw-r--r-- 1 apache apache 362 Jul 23 07:34 planets.txt ############################################################ Positions of selected moons from JPL HORIZONS for JD(UT)2461244.83443836: 08:28:32.70 +19:32:32.3 Io (6.0mag) 08:28:23.21 +19:33:11.3 Europa (6.3mag) 08:28:33.97 +19:32:32.1 Ganymede (5.6mag) 08:28:46.38 +19:31:43.5 Callisto (6.7mag) 08:26:30.03 +19:22:57.1 Himalia (15.7mag) 08:28:34.65 +19:32:25.5 Thebe (16.6mag) 08:25:52.57 +19:24:38.4 Elara (17.7mag) 08:32:23.74 +19:19:59.8 Pasiphae (17.9mag) 08:32:42.59 +19:39:48.9 Carme (19.0mag) 00:56:35.12 +03:22:34.3 Titan (8.5mag) 00:56:41.21 +03:22:21.8 Rhea (9.8mag) 00:56:15.30 +03:19:36.7 Iapetus (11.2mag) 00:56:49.30 +03:21:32.2 Hyperion (14.5mag) 00:56:28.61 +03:17:34.2 Phoebe (16.5mag) -rw-r--r-- 1 apache apache 568 Jul 23 07:34 moons.txt ############################################################ Positions of selected spacecraft from JPL HORIZONS for JD(UT)2461244.83443836: 18:10:10.32 -29:33:17.6 JWST 15:14:20.17 +52:43:44.7 Chandra 10:05:05.45 -56:31:28.8 XMM-Newton -rw-r--r-- 1 apache apache 96 Jul 23 07:34 spacecraft.txt ############################################################ Positions of bright comets computed with util/comet_finder/main.py for JD(UT)2461244.83443836 -observatory V36 02:54:07.11 +15:52:58.6 17.8mag P/1996 R2 (Lagerkvist) 18:08:54.84 -34:36:39.2 13.8mag P/2010 H2 (Vales) 06:38:34.01 -68:24:14.1 17.3mag C/2014 UN271 (Bernardinelli-Bernstein) 06:05:09.46 +32:40:39.9 17.6mag C/2017 K2 (PANSTARRS) 02:49:33.54 +27:01:08.5 16.0mag P/2021 N1 (ZTF) 22:50:59.03 +32:07:22.6 17.3mag C/2022 E2 (ATLAS) 06:26:54.22 +26:47:04.9 16.7mag C/2022 N2 (PANSTARRS) 10:07:01.55 +29:11:34.6 16.9mag C/2022 QE78 (ATLAS) 09:18:14.19 +05:11:48.1 17.9mag C/2022 R6 (PANSTARRS) 15:11:00.69 -11:43:54.3 17.8mag P/2023 B1 (PANSTARRS) 21:32:28.54 +67:16:57.7 17.9mag C/2023 H5 (Lemmon) 16:07:56.74 -11:24:22.2 14.1mag C/2023 R1 (PANSTARRS) 08:23:52.39 +66:27:04.9 18.0mag C/2024 A1 (ATLAS) 07:49:21.83 +30:37:51.4 14.9mag C/2024 E1 (Wierzchos) 15:10:55.86 +15:34:03.2 17.6mag C/2024 G6 (ATLAS) 19:24:10.84 +41:33:48.6 13.7mag C/2024 J3 (ATLAS) 21:32:41.88 +47:45:59.9 17.7mag C/2024 R4 (PANSTARRS) 05:01:36.83 -13:18:02.7 15.6mag C/2024 T5 (ATLAS) 06:44:57.11 +26:53:35.4 17.9mag C/2025 J1 (Borisov) 07:22:45.13 -14:10:11.8 17.1mag C/2025 R3 (PANSTARRS) 10:11:47.87 +21:49:22.7 17.5mag C/2025 V2 (Rankin) 12:49:42.98 +03:18:41.3 17.0mag C/2025 Y1 (ATLAS) 16:20:09.79 +78:57:59.1 17.1mag C/2026 A2 (Bok) 02:58:21.17 +45:44:58.1 16.9mag C/2026 B2 (Sun-Gao) 11:34:23.31 +06:36:32.7 17.1mag A/2026 E1 21:38:24.39 -20:16:50.7 7.0mag 10P/Tempel 11:19:56.79 -02:29:50.1 16.2mag 29P/Schwassmann-Wachmann 04:18:28.72 +30:55:00.0 17.9mag 47P/Ashbrook-Jackson 10:35:04.50 +09:49:57.5 17.1mag 63P/Wild 00:52:47.17 -05:04:29.9 15.5mag 65P/Gunn 04:58:34.24 +20:40:01.0 13.7mag 78P/Gehrels 02:41:53.45 +12:13:49.9 16.4mag 88P/Howell 07:13:13.31 +29:31:38.0 15.9mag 93P/Lovas 05:03:39.82 +31:17:55.6 16.6mag 114P/Wiseman-Skiff 08:40:20.73 +29:05:43.9 15.1mag 123P/West-Hartley 11:12:39.61 -04:02:47.5 16.9mag 124P/Mrkos 05:12:21.31 +21:05:51.9 16.2mag 128P/Shoemaker-Holt 06:00:23.46 +19:29:55.4 17.8mag 131P/Mueller 07:58:27.90 +14:04:43.1 17.1mag 141P-D/Machholz 03:21:34.49 -20:25:37.2 14.8mag 161P/Hartley-IRAS 06:19:54.42 +36:17:08.9 15.5mag 162P/SidingSpring 18:14:53.72 +24:50:12.7 13.6mag 169P/NEAT 02:10:53.84 +08:48:53.2 17.6mag 220P/McNaught 16:36:04.74 -09:01:33.4 17.3mag 235P/LINEAR 20:34:22.06 -51:54:29.8 17.8mag 259P/Garradd 02:36:04.13 +18:07:52.6 15.5mag 260P/McNaught 06:16:53.00 +37:36:48.3 17.3mag 295P/LINEAR 15:06:58.32 +04:49:27.9 17.6mag 391P/Kowalski 08:46:21.75 +19:07:24.7 17.9mag 450P/LONEOS 08:11:55.15 +38:07:10.1 18.0mag 493P/LONEOS -rw-r--r-- 1 apache apache 2.4K Jul 23 07:34 comets.txt ############################################################ List of recent ASAS-SN transients from https://www.astronomy.ohio-state.edu/asassn/transients.html : 04:50:01.03 -02:22:33.80 ASASSN-26ej 2026-07-16.17 17.02 18:34:55.28 -31:41:00.90 ASASSN-26ek 2026-07-16.24 15.73 17:07:43.61 -44:21:53.50 ASASSN-26el 2026-07-15.86 16.01 14:45:08.35 +24:13:12.30 ASASSN-26ei 2026-07-16.17 16.46 10:00:46.44 -32:36:31.10 AT 2023mhb 2026-07-14.73 16.67 14:39:37.45 -11:22:36.20 AT 2026unl 2026-07-15.27 17.11 10:49:42.57 -11:25:55.80 ASASSN-26eh 2026-07-14.72 16.58 19:33:53.06 -07:15:00.80 ASASSN-26eg 2026-07-14.15 15.5 02:45:40.52 -27:55:30.30 ASASSN-26ef 2026-07-12.35 15.86 23:26:43.80 +04:42:39.70 SN 2026qtn 2026-07-12.22 16.47 02:19:17.26 +28:57:15.40 ASASSN-26ec 2026-07-11.53 2.78 18:31:15.56 -05:34:31.50 AT2026stb 2026-07-11.28 -1.29 13:36:08.24 +23:29:05.00 AT2026pjf 2026-07-10.18 -0.72 17:33:39.82 +04:22:36.70 SN2026pir 2026-07-9.86 -0.66 11:21:41.26 -50:33:36.30 ASASSN-26ed 2026-07-8.8 -1.3 23:41:42.11 +26:29:49.10 AT2026qil 2026-07-9.3 16.15 20:21:30.50 -32:03:40.10 ASASSN-26ee 2026-07-7.22 15.53 19:37:44.09 -05:35:42.80 AT2026ryu 2026-07-7.17 14.88 11:06:55.46 -04:07:04.50 AT2026qqg 2026-07-5.01 16.82 19:07:23.69 -74:13:37.30 AT2026qly 2026-07-5.02 17.31 17:57:43.80 +27:18:40.10 ASASSN-26ea 2026-07-5.07 16.67 19:59:01.43 -32:07:34.30 ASASSN-26eb 2026-07-4.97 15.52 18:46:50.35 -57:44:13.20 SN 2026qqp 2026-07-5.03 -0.92 19:17:31.69 -39:55:29.90 ASASSN-26dz 2026-07-5.14 15.91 19:14:31.37 +12:03:52.90 AT 2026rdg 2026-07-3.43 11.81 04:05:50.09 -70:24:34.40 AT 2026qpr 2026-06-30.4 15.96 13:45:37.49 -05:59:35.80 SN 2026pub 2026-06-30.09 16.01 16:41:15.63 +39:17:14.70 SN 2026pel 2026-06-26.38 16.07 10:14:40.19 -35:38:21.30 ASASSN-26dy 2026-06-25.99 15.63 14:47:21.56 -40:15:51.30 ASASSN-26dv 2026-06-23.03 14.62 13:38:49.79 -77:21:06.70 ASASSN-26dw 2026-06-23.04 16.09 00:59:27.90 +33:08:13.20 SN 2026mke 2026-06-22.39 17.13 11:10:44.73 -30:20:45.50 SN 2026nmv 2026-06-22.06 16.56 21:36:15.68 -21:19:12.50 AT2026oxh 2026-06-22.15 17.14 17:31:38.38 -56:05:51.90 ASASSN-26dx 2026-06-22.02 14.72 14:10:13.44 -38:46:46.10 AT2026pvk 2026-06-22.06 16.53 20:56:47.23 -18:31:05.20 AT2026plb 2026-06-21.31 16.4 15:44:29.68 +21:00:59.30 SN2026ore 2026-06-21.29 17.57 23:50:05.98 -14:01:41.30 AT2026oxl 2026-06-21.52 17.64 17:36:54.73 -18:10:04.20 AT2026ouj 2026-06-20.92 15.15 00:34:04.08 -30:22:09.20 AT2026ntk 2026-06-18.09 17.34 20:49:13.39 +25:17:59.20 ASASSN-26du 2026-06-15.39 15.93 23:09:30.84 +32:40:42.00 SN2026oxc 2026-06-14.35 16.83 02:02:26.78 +32:04:21.30 AT2026ovz 2026-06-14.59 15.39 21:26:28.11 -72:31:19.50 AT2026nwc 2026-06-11 17.05 17:54:57.33 +26:32:34.20 SN 2026odc 2026-06-11.23 17.62 13:55:59.94 +17:30:37.20 SN 2026nyq 2026-06-11.1 16.24 00:50:45.14 -71:38:36.90 ASASSN-26dt 2026-06-11.13 10.22 14:42:19.73 +19:11:35.60 SN2026nyp 2026-06-10.3 16.32 12:23:23.92 +12:56:43.50 SN2026mta 2026-06-8.29 16.69 12:30:18.51 +47:12:33.20 SN2026oao 2026-06-9.32 17.02 10:51:05.21 -42:28:56.60 AT2026nvf 2026-06-8.12 16.75 13:50:22.48 -07:35:00.00 SN2026npn 2026-06-8.02 17.58 00:56:07.17 +43:01:43.20 ASASSN-26dq 2026-06-7.43 13.58 01:07:49.46 +41:59:43.70 SN 2026obc 2026-06-7.43 15.15 21:11:25.22 +14:14:31.90 ASASSN-26dr 2026-06-7.24 16.24 06:21:27.06 -65:16:42.00 ASASSN-26ds 2026-06-2.97 15.02 20:07:38.15 -21:07:05.40 SN2026mho 2026-05-25.18 -1.12 11:29:42.55 +79:01:03.10 AT2026min 2026-05-24.21 16.63 11:44:32.95 -68:48:30.00 ASASSN-26no 2026-05-24 8.41 19:00:42.82 -48:31:01.60 ASASSN-26dp 2026-05-22.31 -3.28 14:23:56.72 -58:37:47.60 ASASSN-26dn 2026-05-20.01 14.64 11:24:54.06 +47:57:01.60 AT2026nma 2026-05-20.29 15.46 21:27:08.58 +33:24:38.10 AT2026lli 2026-05-19.34 15.86 00:31:01.41 -13:38:51.70 AT2026nad 2026-05-19.39 15.34 15:16:06.61 -79:16:32.40 ASASSN-26dm 2026-05-19.03 14.44 11:24:25.21 -59:23:19.10 ASASSN-26dl 2026-05-18.02 13.55 13:45:51.52 -53:16:01.00 ASASSN-26dk 2026-05-18.16 12.96 02:05:49.69 -30:29:09.60 ASASSN-26dh 2026-05-18.43 15.37 17:50:22.87 -39:42:33.90 ASASSN-26dj 2026-05-17.05 15.7 01:13:11.60 -33:25:16.10 ASASSN-26dg 2026-05-13.41 16.8 16:44:31.77 -27:15:18.40 AT2026mhn 2026-05-12.33 15.8 09:46:31.08 -33:41:51.00 ASASSN-26di 2026-05-12.14 14.63 21:23:11.57 -19:09:45.00 AT2026kwu 2026-05-12.26 16.9 14:20:14.30 -30:20:51.90 AT2026ktm 2026-05-12.06 17.21 14:41:39.01 -37:13:46.40 AT2026lkm 2026-05-11.18 16.89 12:59:50.45 -10:58:38.80 SN2026kep 2026-05-9.06 17.5 13:37:29.61 -29:50:30.90 AT2026lkd 2026-05-9.09 17.23 09:46:42.01 -14:52:03.60 SN2026kmo 2026-05-8.99 17.51 15:03:05.28 +22:02:03.80 AT2026lxf 2026-05-8.34 13.72 10:23:49.41 -20:57:25.30 ASASSN-26df 2026-05-8.21 16.52 22:14:40.56 +05:04:51.60 2026lda 2026-05-7.56 16.2 21:35:33.81 -14:05:16.30 ASASSN-26de 2026-05-6.29 14.51 16:21:49.13 -61:36:14.60 ASASSN-26dd 2026-05-5.15 15.93 14:26:40.22 -24:48:37.50 AT2026lig 2026-05-4.27 14.63 13:17:51.04 +30:25:13.50 SN2026kcp 2026-05-4.46 16.43 11:27:55.57 -13:38:56.90 SN2026kza 2026-05-1.08 15.59 22:28:27.10 +30:17:54.30 SN 2026fov 2026-04-29.6 14.36 21:00:10.71 -32:17:03.90 AT2026kis 2026-04-27.36 16.15 14:32:57.37 -58:13:26.40 ASASSN-26dc 2026-04-27.27 13.42 15:32:05.35 -43:54:34.60 ASASSN-26db 2026-04-27.37 16.06 16:34:34.97 -54:34:58.00 ASASSN-26da 2026-04-25.32 16.11 10:06:55.04 -01:13:49.70 SN2026jsg 2026-04-24.99 16.28 15:15:57.17 +56:18:32.80 SN2026kid 2026-04-24.52 -3.65 07:58:28.45 +57:03:42.40 AT2026kcf 2026-04-24.2 16.89 11:38:21.80 -50:43:06.50 SN2026jkb 2026-04-24.24 15.38 10:06:11.41 -39:41:04.20 AT2026dil 2026-04-24.2 16.85 14:21:40.08 +13:13:46.30 SN2026jlm 2026-04-22.16 15.12 10:53:55.52 -16:06:06.00 ASASSN-26cz 2026-04-22.28 16.29 04:50:01.03 -02:22:33.80 2026-07-16.17 17.02 -rw-r--r-- 1 apache apache 5.6K Jul 23 07:34 asassn_transients_list.txt ############################################################ Truncated list of TOCP transients from http://www.cbat.eps.harvard.edu/unconf/tocp.html : 15:03:05.19 +22:02:04.1 TCP J15030519+2202041 2026-05-08.3260 13.9mag 07:15:18.25 +47:53:16.7 TCP J07151825+4753167 2026-05-09.1599 14.4mag 16:00:18.44 -22:30:10.6 TCP J16001844-2230106 2026-05-09.6135 13.3mag 00:42:47.45 +41:16:58.5 PNV J00424745+4116585 2026-05-10.030 16.8mag 09:55:02.89 +69:02:13.8 PNV J09550289+6902138 2026-05-18.925 20.7mag 00:43:01.82 +41:18:16.6 PNV J00430182+4118166 2026-05-21.8651 18.83Cmag 00:42:51.20 +41:16:59.4 PNV J00425120+4116594 2022-10-26.135 19.3mag 12:24:25.10 +28:47:12.0 TCP J12242510+2847120 2026-05-31.6015 14.8mag 00:56:07.13 +43:01:40.6 TCP J00560713+4301406 2026-06-01.4135 12.2mag 00:42:41.64 +41:15:16.2 PNV J00424164+4115162 2026-06-02.029 17.4mag 00:42:38.68 +41:15:58.2 PNV J00423868+4115582 2026-06-05.1224 19.97Umag 19:00:42.95 -48:31:01.7 PNV J19004295-4831017 2026-05-25.0752 14.2mag 09:55:21.28 +69:02:52.6 PNV J09552128+6902526 2026-06-13.933 18.9mag 19:51:21.42 +37:06:40.0 TCP J19512142+3706400 2026-06-17.2942 16.8mag 19:57:03.87 +37:41:46.4 TCP J19570387+3741464 2026-06-18.2638 17.5mag 00:42:32.04 +41:10:28.3 PNV J00423204+4110283 2026-06-26.059 16.6mag 02:19:17.36 +28:57:15.8 TCP J02191736+2857158 2026-07-12.3549 12.5mag 00:44:56.43 +41:57:41.6 PNV J00445643+4157416 2026-07-13.8026 17.98Cmag 00:42:55.36 +41:17:27.0 PNV J00425536+4117270 2026-07-20.1813 17.7mag 20:35:43.64 +61:31:32.9 TCP J20354364+6131329 2026-07-20.5443 14.4mag -rw-r--r-- 1 apache apache 189K Jul 23 07:34 tocp_transients_list.txt ############################################################ Truncated list of recent TNS transients from https://www.wis-tns.org/ : 15:40:49.500 +03:40:01.11 AT 2026tok 2026-07-09.29 19.19 13:28:58.224 -31:39:58.70 AT 2026toj 2026-01-27.63 20.99 16:19:43.736 +12:53:16.12 AT 2026toi 2026-06-19.41 20.78 12:16:00.811 +13:52:30.28 AT 2026toh 2026-06-05.33 21.31 08:05:33.164 +19:53:59.86 AT 2026tog 2026-05-05.27 21.02 22:22:27.296 -01:16:48.01 AT 2026tof 2026-06-20.59 21.53 18:21:21.782 +34:34:12.08 AT 2026toe 2026-06-06.57 20.8 09:23:56.056 +15:48:10.98 AT 2026tod 2026-03-09.25 20.93 14:30:53.211 +02:37:48.55 AT 2026toc 2026-02-24.60 21.68 18:53:53.654 +37:31:27.95 AT 2026tob 2026-06-06.57 20.33 14:02:45.983 +27:31:29.38 AT 2026toa 2026-01-13.59 21.55 11:45:46.289 -15:58:14.20 AT 2026tnz 2026-04-19.34 21.32 17:01:06.389 +36:02:56.61 AT 2026tny 2026-06-22.29 20.16 14:21:15.460 +00:01:06.82 AT 2026tnx 2026-05-17.42 21.17 16:56:29.803 +29:23:52.18 AT 2026tnw 2026-06-06.48 20.57 13:19:42.648 +33:06:54.64 AT 2026tnv 2026-05-13.26 20.86 11:42:50.112 -20:30:52.08 AT 2026tnu 2026-02-14.47 20.76 21:12:00.798 -45:40:32.46 AT 2026tnt 2026-06-19.54 20.97 08:38:13.357 -04:40:15.41 AT 2026tns 2026-02-24.31 20.85 01:14:19.100 +10:26:27.44 AT 2026tnr 2026-06-21.59 20.53 -rw-r--r-- 1 apache apache 88K Jul 23 07:34 tns_transients_list.txt

Profiling:

CPU temperature: 90 C