NMW transient search results

This analysis is done by the script util/transients/transient_factory_test31.sh /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt

The list of candidates will appear below. Please manually reload the page every few minutes untill the 'Processing complete' message appears.

Processing fields Dra-07-Q2b1x1

Processing complete!

Total number of candidates identified: 0

Processing log:

Filtering log:

######## Processing parameters ########
AAVSO_COMMENT_STRING= NMW-TexasTech Camera-2 135mm f/2.2 telephoto lens + QHY600M CMOS
ASTCHECK_ASTEROID_SEARCH_RADIUS_ARCSEC= 
BAD_REGION_FILE= /var/www/nmw_calibration/TTUQ2b1x1/TTUQ2_bad_region.lst
CAMERA_SETTINGS= TTUQ2b1x1
CHECK_POINTING_ACCURACY= yes
DARK_FRAMES_DIR_OR_FILE= /var/www/nmw_calibration/TTUQ2b1x1/darks
EXCLUSION_LIST= ../exclusion_list_TTUQ2.txt
FILTER_BAD_IMG__MAX_APERTURE_STAR_SIZE_PIX= 12.5
FILTER_BAD_IMG__MAX_ELONGATION_AminusB_PIX= 0.55
FILTER_BAD_IMG__MIN_APERTURE_STAR_SIZE_PIX= 2.0
FILTER_BRIGHT_MAG_CUTOFF_TRANSIENT_SEARCH= -5
FILTER_FAINT_MAG_CUTOFF_TRANSIENT_SEARCH= 15.0
FLAT_FIELD_DIR_OR_FILE= /var/www/nmw_calibration/TTUQ2b1x1/flats
FRAME_EDGE_OFFSET_PIX= 600
GAIA_BAND_FOR_CATALOGED_SOURCE_CHECK= 
MAX_NEW_TO_REF_MEAN_IMG_VALUE_RATIO= 100
MAX_NEW_IMG_MEAN_VALUE= 25000
MAX_SD_RATIO_OF_SECOND_EPOCH_IMGS= 0.18
MAX_SD_RATIO_OF_SECOND_EPOCH_IMGS_SOFT_LIMIT= 0.12
MPC_CODE= V36
NMW_CALIBRATION= /var/www/nmw_calibration
NUMBER_OF_DETECTED_TRANSIENTS_BEFORE_FILTERING_HARD_LIMIT= 8000
NUMBER_OF_DETECTED_TRANSIENTS_BEFORE_FILTERING_SOFT_LIMIT= 4000
OMP_NUM_THREADS= 
ONLINE_MPCHECKER_BUTTON_ASTEROID_SEARCH_RADIUS_ARCMIN= 
PHOTOMETRIC_CALIBRATION= 
REQUIRE_PIX_SHIFT_BETWEEN_IMAGES_FOR_TRANSIENT_CANDIDATES= yes
SEXTRACTOR_CONFIG_BRIGHTSTARPASS= default.sex.telephoto_lens_onlybrightstars_v1
SEXTRACTOR_CONFIG_FILES= default.sex.telephoto_lens_onlybrightstars_v1 default.sex.telephoto_lens_vSTL
STARMATCH_RADIUS_PIX= 4
SYSREM_ITERATIONS= 0
TELESCOP= 
TELESCOP_NAME_KNOWN_TO_VaST_FOR_FOV_DETERMINATION= 
UCAC5_PLATESOLVE_ITERATIONS= 2
FPACK_FULLY_CALIBRATED_IMAGE= no
#######################################
HOSTNAME= tau
USER= 
HOME= 
#######################################
SExtractor catalog cache: enabled, directory /data_ssd/NMW-TexasTech/vast_sextractor_cache
Reference image directory is set to /data_ssd/NMW-TexasTech/reference_imgs
VIZIER_SITE=vizier.cds.unistra.fr
GAIA_DR2_CLIENT=vizquery (lib/vizquery -> VizieR vizier.cds.unistra.fr)
INFO: MAKE_PNG_PLOTS is set to yes
FITS_FILE_EXT=fits
CALIBRATION_STATUS_PREFIX=
Fields in the data directory: 
Dra-07-Q2b1x1
#######################################
########### Starting Dra-07-Q2b1x1 ###########
Processing Dra-07-Q2b1x1
server tau has sufficient free disk space available: 557193 MB at /data_ssd/NMW-TexasTech/workdir
server tau has sufficient free disk space available: 557193 MB at .
Checking input images (2 new)
REFERENCE_EPOCH__FIRST_IMAGE= /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits
REFERENCE_EPOCH__SECOND_IMAGE= /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits
Small preview (one of the new images): 
Large previews of the second-epoch (new) images:
MAKE_PNG_PLOTS=yes
renamed 'Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.png' -> 'transient_report/Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits_preview.png'
Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits

renamed 'Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.png' -> 'transient_report/Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits_preview.png'
Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits


Read-check the input FITS images... read-check OK Blank image check the input FITS images... blank-image-check OK Read date check the input FITS images... read-date-check OK Mean value check the input FITS images... OK, at least two new images have mean values below the threshold. ---------------------------------------------- INFO: REFERENCE_EPOCH__FIRST_IMAGE_MEAN_VALUE= 396.0722 INFO: REFERENCE_EPOCH__FIRST_IMAGE_SD= 539.7815 INFO: SECOND_EPOCH__FIRST_IMAGE_MEAN_VALUE= 883.1970 INFO: SECOND_EPOCH__FIRST_IMAGE_SD= 543.2872 INFO: SECOND_EPOCH__SECOND_IMAGE_MEAN_VALUE= 883.7508 INFO: SECOND_EPOCH__SECOND_IMAGE_SD= 543.8354 ---------------------------------------------- INFO: ref_to_second_epoch_img_mean_ratio= 2.22989 INFO: SECOND_EPOCH__SD_ratio= 0.001 ---------------------------------------------- Calibration settings: DARK_FRAMES_DIR_OR_FILE=/var/www/nmw_calibration/TTUQ2b1x1/darks FLAT_FIELD_DIR_OR_FILE=/var/www/nmw_calibration/TTUQ2b1x1/flats EXPTIME = 20.0 / [s] Exposure duration SET-TEMP= 5.0 / [degC] CCD temperature setpoint CCD-TEMP= 4.9 / [degC] CCD temperature FOCTEMP = 23.3999996185303 / [degC] Focuser temperature AMBTEMP = 24.2 / [degC] Ambient air temperature Exploring image header: /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits CCD-TEMP= 4.900000 for /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits SET-TEMP= 5.000000 for /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Header: 74 keys total, 33 keys left Record 0: "" status=0 Record 1: "SIMPLE = T / C# FITS" status=0 Record 2: "BITPIX = 16" status=0 Record 3: "NAXIS = 2 / Dimensionality" status=0 Record 4: "NAXIS1 = 9576" status=0 Record 5: "NAXIS2 = 6388" status=0 Record 6: "BZERO = 32768" status=0 Record 7: "EXTEND = T / Extensions are permitted" status=0 Record 8: "IMAGETYP= 'LIGHT' / Type of exposure" status=0 Record 9: "EXPOSURE= 20.0 / [s] Exposure duration" status=0 Record 10: "EXPTIME = 20.0 / [s] Exposure duration" status=0 Record 11: "DATE-LOC= '2026-06-11T03:16:32.0931863' / Time of observation (local)" status=0 Record 12: "DATE-OBS= '2026-06-11T08:16:32.0931863' / Time of observation (UTC)" status=0 Record 13: "MJD-OBS = 61202.3448158912 / Modified Julian Date of observation" status=0 Record 14: "DATE-AVG= '2026-06-11T08:16:41.9962521' / Averaged midpoint time (UTC)" status=0 Record 15: "MJD-AVG = 61202.3449305091 / Modified Julian Date of averaged midpoint" status=0 Record 16: "XBINNING= 1 / X axis binning factor" status=0 Record 17: "YBINNING= 1 / Y axis binning factor" status=0 Record 18: "GAIN = 30 / Sensor gain" status=0 Record 19: "OFFSET = 30 / Sensor gain offset" status=0 Record 20: "XPIXSZ = 3.76 / [um] Pixel X axis size" status=0 Record 21: "YPIXSZ = 3.76 / [um] Pixel Y axis size" status=0 Record 22: "INSTRUME= 'QHY600M' / Imaging instrument name" status=0 Record 23: "CAMERAID= 'QHY600M-84137c4dbbbd119a9' / Imaging instrument identifier" status=0 Record 24: "SET-TEMP= 5.0 / [degC] CCD temperature setpoint" status=0 Record 25: "CCD-TEMP= 4.9 / [degC] CCD temperature" status=0 Record 26: "READOUTM= '2CMS-0' / Sensor readout mode" status=0 Record 27: "USBLIMIT= 50 / Camera-specific USB setting" status=0 Record 28: "TELESCOP= 'QHY600M-TTU2' / Name of telescope" status=0 Record 29: "FOCALLEN= 135.0 / [mm] Focal length" status=0 Record 30: "FOCRATIO= 2.2 / Focal ratio" status=0 Record 31: "RA = 257.142818283573 / [deg] RA of telescope" status=0 Record 32: "DEC = 61.9997901478205 / [deg] Declination of telescope" status=0 Record 33: "CENTALT = 57.7075 / [deg] Altitude of telescope" status=0 Record 34: "CENTAZ = 338.4075 / [deg] Azimuth of telescope" status=0 Record 35: "AIRMASS = 1.18243946857339 / Airmass at frame center (Gueymard 1993)" status=0 Record 36: "PIERSIDE= 'East' / Telescope pointing state" status=0 Record 37: "SITEELEV= 1009.5 / [m] Observation site elevation" status=0 Record 38: "SITELAT = 33.7482925 / [deg] Observation site latitude" status=0 Record 39: "SITELONG= -101.958319 / [deg] Observation site longitude" status=0 Record 40: "OBSERVER= 'Sokolovsky' / Observer name" status=0 Record 41: "OBSERVAT= 'TTU Skyview' / Observatory name" status=0 Record 42: "SITENAME= '' / Observatory site name" status=0 Record 43: "FWHEEL = 'Simulator' / Filter Wheel name" status=0 Record 44: "FILTER = 'CV' / Active filter name" status=0 Record 45: "OBJECT = 'Dra-07' / Name of the object of interest" status=0 Record 46: "OBJCTRA = '17 08 34' / [H M S] RA of imaged object" status=0 Record 47: "OBJCTDEC= '+62 00 00' / [D M S] Declination of imaged object" status=0 Record 48: "OBJCTROT= 0.0 / [deg] planned rotation of imaged object" status=0 Record 49: "FOCNAME = 'ZWO Focuser' / Focusing equipment name" status=0 Record 50: "FOCPOS = 20435 / [step] Focuser position" status=0 Record 51: "FOCUSPOS= 20435 / [step] Focuser position" status=0 Record 52: "FOCUSSZ = 0.0 / [um] Focuser step size" status=0 Record 53: "FOCTEMP = 23.3999996185303 / [degC] Focuser temperature" status=0 Record 54: "FOCUSTEM= 23.3999996185303 / [degC] Focuser temperature" status=0 Record 55: "DEWPOINT= 17.2 / [degC] Dew point" status=0 Record 56: "HUMIDITY= 65.0 / [percent] Relative humidity" status=0 Record 57: "PRESSURE= 893.19 / [hPa] Air pressure" status=0 Record 58: "AMBTEMP = 24.2 / [degC] Ambient air temperature" status=0 Record 59: "WINDDIR = 37.0 / [deg] Wind direction: 0=N, 180=S, 90=E, 270=W" status=0 Record 60: "WINDGUST= 29.50236 / [kph] Wind gust" status=0 Record 61: "WINDSPD = 19.801584 / [kph] Wind speed" status=0 Record 62: "ROWORDER= 'TOP-DOWN' / FITS Image Orientation" status=0 Record 63: "EQUINOX = 2000.0 / Equinox of celestial coordinate system" status=0 Record 64: "SWCREATE= 'N.I.N.A. 3.2.0.9001 (x64)' / Software that created this file" status=0 Record 65: "QHY_EXP = 20.000096 / [s] Actual exposure time" status=0 Record 66: "QHY_PP = 13888.0 / [ps] pixelPeriod" status=0 Record 67: "QHY_LP = 85000.0 / [ns] linePeriod" status=0 Record 68: "GPS_LP = 85000.0 / [ns] linePeriod" status=0 Record 69: "QHY_FP = 20000160.0 / [us] framePeriod" status=0 Record 70: "QHY_CPL = 6120.0 / clocksPerLine" status=0 Record 71: "QHY_LPF = 235295.0 / linesPerFrame" status=0 Record 72: "QHY_AET = 20000096.0 / [us] actualExposureTime" status=0 Record 73: "QHY_LEM = T / isLongExposureMode" status=0 Record 74: "QHY_OFF0= 3767.777 / [us] RollingShutterEndOffset row 0" status=0 Allocating memory for image, dark and result arrays... Reading image /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits 9576 6388 16 bitpix SET-TEMP= 5.000000 for /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits SET-TEMP= 5.000000 for /var/www/nmw_calibration/TTUQ2b1x1/darks/mdark_TTUQ2b1x1_5C_20s_2026-05-30.fit CCD-TEMP= 4.900000 for /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits CCD-TEMP= 4.800000 for /var/www/nmw_calibration/TTUQ2b1x1/darks/mdark_TTUQ2b1x1_5C_20s_2026-05-30.fit Reading dark frame /var/www/nmw_calibration/TTUQ2b1x1/darks/mdark_TTUQ2b1x1_5C_20s_2026-05-30.fit 9576 6388 16 bitpix Dark frame is subtracted, output is written to /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/d_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits :) Spent 0.606721 seconds renamed 'mdark_TTUQ2b1x1_5C_20s_2026-05-30.png' -> 'transient_report/dark.png' try_to_calibrate_the_input_frame(): selected flat field /var/www/nmw_calibration/TTUQ2b1x1/flats/mff_TTUQ2b1x1_2026-05-30.fit from directory /var/www/nmw_calibration/TTUQ2b1x1/flats MegaDivider v7 Reading image /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/d_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits 9576 6388 16 bitpix Reading flat /var/www/nmw_calibration/TTUQ2b1x1/flats/mff_TTUQ2b1x1_2026-05-30.fit 9576 6388 16 bitpix Avarage count on flat field image: 20659.746399 Minimal real count (from overscan): 5 Output is written to /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits :) No overscan detected - all values seem high! (left_median=14784.5, right_median=14894.5) renamed 'mff_TTUQ2b1x1_2026-05-30.png' -> 'transient_report/flat.png' Using calibrated image CALIBRATED_SECOND_EPOCH__FIRST_IMAGE=/data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits EXPTIME = 20.0 / [s] Exposure duration SET-TEMP= 5.0 / [degC] CCD temperature setpoint CCD-TEMP= 5.0 / [degC] CCD temperature FOCTEMP = 23.3400001525879 / [degC] Focuser temperature AMBTEMP = 24.2 / [degC] Ambient air temperature Exploring image header: /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits CCD-TEMP= 5.000000 for /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits SET-TEMP= 5.000000 for /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits Header: 74 keys total, 33 keys left Record 0: "" status=0 Record 1: "SIMPLE = T / C# FITS" status=0 Record 2: "BITPIX = 16" status=0 Record 3: "NAXIS = 2 / Dimensionality" status=0 Record 4: "NAXIS1 = 9576" status=0 Record 5: "NAXIS2 = 6388" status=0 Record 6: "BZERO = 32768" status=0 Record 7: "EXTEND = T / Extensions are permitted" status=0 Record 8: "IMAGETYP= 'LIGHT' / Type of exposure" status=0 Record 9: "EXPOSURE= 20.0 / [s] Exposure duration" status=0 Record 10: "EXPTIME = 20.0 / [s] Exposure duration" status=0 Record 11: "DATE-LOC= '2026-06-11T03:17:21.7911728' / Time of observation (local)" status=0 Record 12: "DATE-OBS= '2026-06-11T08:17:21.7911728' / Time of observation (UTC)" status=0 Record 13: "MJD-OBS = 61202.3453910993 / Modified Julian Date of observation" status=0 Record 14: "DATE-AVG= '2026-06-11T08:17:31.6913393' / Averaged midpoint time (UTC)" status=0 Record 15: "MJD-AVG = 61202.3455056828 / Modified Julian Date of averaged midpoint" status=0 Record 16: "XBINNING= 1 / X axis binning factor" status=0 Record 17: "YBINNING= 1 / Y axis binning factor" status=0 Record 18: "GAIN = 30 / Sensor gain" status=0 Record 19: "OFFSET = 30 / Sensor gain offset" status=0 Record 20: "XPIXSZ = 3.76 / [um] Pixel X axis size" status=0 Record 21: "YPIXSZ = 3.76 / [um] Pixel Y axis size" status=0 Record 22: "INSTRUME= 'QHY600M' / Imaging instrument name" status=0 Record 23: "CAMERAID= 'QHY600M-84137c4dbbbd119a9' / Imaging instrument identifier" status=0 Record 24: "SET-TEMP= 5.0 / [degC] CCD temperature setpoint" status=0 Record 25: "CCD-TEMP= 5.0 / [degC] CCD temperature" status=0 Record 26: "READOUTM= '2CMS-0' / Sensor readout mode" status=0 Record 27: "USBLIMIT= 50 / Camera-specific USB setting" status=0 Record 28: "TELESCOP= 'QHY600M-TTU2' / Name of telescope" status=0 Record 29: "FOCALLEN= 135.0 / [mm] Focal length" status=0 Record 30: "FOCRATIO= 2.2 / Focal ratio" status=0 Record 31: "RA = 257.142818287025 / [deg] RA of telescope" status=0 Record 32: "DEC = 61.9997900848314 / [deg] Declination of telescope" status=0 Record 33: "CENTALT = 57.6433333333333 / [deg] Altitude of telescope" status=0 Record 34: "CENTAZ = 338.268611111111 / [deg] Azimuth of telescope" status=0 Record 35: "AIRMASS = 1.18327561834162 / Airmass at frame center (Gueymard 1993)" status=0 Record 36: "PIERSIDE= 'East' / Telescope pointing state" status=0 Record 37: "SITEELEV= 1009.5 / [m] Observation site elevation" status=0 Record 38: "SITELAT = 33.7482925 / [deg] Observation site latitude" status=0 Record 39: "SITELONG= -101.958319 / [deg] Observation site longitude" status=0 Record 40: "OBSERVER= 'Sokolovsky' / Observer name" status=0 Record 41: "OBSERVAT= 'TTU Skyview' / Observatory name" status=0 Record 42: "SITENAME= '' / Observatory site name" status=0 Record 43: "FWHEEL = 'Simulator' / Filter Wheel name" status=0 Record 44: "FILTER = 'CV' / Active filter name" status=0 Record 45: "OBJECT = 'Dra-07' / Name of the object of interest" status=0 Record 46: "OBJCTRA = '17 08 34' / [H M S] RA of imaged object" status=0 Record 47: "OBJCTDEC= '+62 00 00' / [D M S] Declination of imaged object" status=0 Record 48: "OBJCTROT= 0.0 / [deg] planned rotation of imaged object" status=0 Record 49: "FOCNAME = 'ZWO Focuser' / Focusing equipment name" status=0 Record 50: "FOCPOS = 20435 / [step] Focuser position" status=0 Record 51: "FOCUSPOS= 20435 / [step] Focuser position" status=0 Record 52: "FOCUSSZ = 0.0 / [um] Focuser step size" status=0 Record 53: "FOCTEMP = 23.3400001525879 / [degC] Focuser temperature" status=0 Record 54: "FOCUSTEM= 23.3400001525879 / [degC] Focuser temperature" status=0 Record 55: "DEWPOINT= 17.2 / [degC] Dew point" status=0 Record 56: "HUMIDITY= 65.0 / [percent] Relative humidity" status=0 Record 57: "PRESSURE= 893.19 / [hPa] Air pressure" status=0 Record 58: "AMBTEMP = 24.2 / [degC] Ambient air temperature" status=0 Record 59: "WINDDIR = 37.0 / [deg] Wind direction: 0=N, 180=S, 90=E, 270=W" status=0 Record 60: "WINDGUST= 29.50236 / [kph] Wind gust" status=0 Record 61: "WINDSPD = 19.801584 / [kph] Wind speed" status=0 Record 62: "ROWORDER= 'TOP-DOWN' / FITS Image Orientation" status=0 Record 63: "EQUINOX = 2000.0 / Equinox of celestial coordinate system" status=0 Record 64: "SWCREATE= 'N.I.N.A. 3.2.0.9001 (x64)' / Software that created this file" status=0 Record 65: "QHY_EXP = 20.000096 / [s] Actual exposure time" status=0 Record 66: "QHY_PP = 13888.0 / [ps] pixelPeriod" status=0 Record 67: "QHY_LP = 85000.0 / [ns] linePeriod" status=0 Record 68: "GPS_LP = 85000.0 / [ns] linePeriod" status=0 Record 69: "QHY_FP = 20000160.0 / [us] framePeriod" status=0 Record 70: "QHY_CPL = 6120.0 / clocksPerLine" status=0 Record 71: "QHY_LPF = 235295.0 / linesPerFrame" status=0 Record 72: "QHY_AET = 20000096.0 / [us] actualExposureTime" status=0 Record 73: "QHY_LEM = T / isLongExposureMode" status=0 Record 74: "QHY_OFF0= 3767.777 / [us] RollingShutterEndOffset row 0" status=0 Allocating memory for image, dark and result arrays... Reading image /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits 9576 6388 16 bitpix SET-TEMP= 5.000000 for /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits SET-TEMP= 5.000000 for /var/www/nmw_calibration/TTUQ2b1x1/darks/mdark_TTUQ2b1x1_5C_20s_2026-05-30.fit CCD-TEMP= 5.000000 for /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits CCD-TEMP= 4.800000 for /var/www/nmw_calibration/TTUQ2b1x1/darks/mdark_TTUQ2b1x1_5C_20s_2026-05-30.fit Reading dark frame /var/www/nmw_calibration/TTUQ2b1x1/darks/mdark_TTUQ2b1x1_5C_20s_2026-05-30.fit 9576 6388 16 bitpix Dark frame is subtracted, output is written to /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/d_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits :) Spent 0.621990 seconds renamed 'mdark_TTUQ2b1x1_5C_20s_2026-05-30.png' -> 'transient_report/dark.png' try_to_calibrate_the_input_frame(): selected flat field /var/www/nmw_calibration/TTUQ2b1x1/flats/mff_TTUQ2b1x1_2026-05-30.fit from directory /var/www/nmw_calibration/TTUQ2b1x1/flats MegaDivider v7 Reading image /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/d_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits 9576 6388 16 bitpix Reading flat /var/www/nmw_calibration/TTUQ2b1x1/flats/mff_TTUQ2b1x1_2026-05-30.fit 9576 6388 16 bitpix Avarage count on flat field image: 20659.746399 Minimal real count (from overscan): 5 Output is written to /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits :) No overscan detected - all values seem high! (left_median=14784.5, right_median=14894.5) renamed 'mff_TTUQ2b1x1_2026-05-30.png' -> 'transient_report/flat.png' Using calibrated image CALIBRATED_SECOND_EPOCH__SECOND_IMAGE=/data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits Dark frame used to calibrate the second-epoch images:

Flat field used to calibrate the second-epoch images:

after the calibration attempt: SECOND_EPOCH__FIRST_IMAGE=/data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits SECOND_EPOCH__SECOND_IMAGE=/data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits Previews of the CALIBRATED second-epoch images:

fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits


fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits


Updating neverexclude_list.txt '/var/www/nmw_calibration/neverexclude_list.txt' -> './neverexclude_list.txt' Choosing bad regions list '/var/www/nmw_calibration/TTUQ2b1x1/TTUQ2_bad_region.lst' -> 'bad_region.lst' wait *------ default.sex.telephoto_lens_onlybrightstars_v1 ------* 'default.sex.telephoto_lens_onlybrightstars_v1' -> 'default.sex' Starting VaST with default.sex.telephoto_lens_onlybrightstars_v1 ./vast --norotation --noflagimage --starmatchraius 4 --matchstarnumber 500 --selectbestaperture --sysrem 0 --type 4 --maxsextractorflag 99 --UTC --nofind --nojdkeyword /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits SExtractor catalog cache: saved Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.cat to cache SExtractor catalog cache: saved Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits.cat to cache VaST run complete with default.sex.telephoto_lens_onlybrightstars_v1 The four input images were /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits Checking WCS cache directory local_wcs_cache Checking WCS cache directory /mnt/usb/NMW_NG/solved_reference_images Found WCS cache directory /mnt/usb/NMW_NG/solved_reference_images Checking WCS cache directory /home/NMW_web_upload/solved_reference_images Checking WCS cache directory /dataX/kirx/NMW_NG_rt3_autumn2019/solved_reference_images The reference JD(UT) for computing planet and comet positions: 2461202.84493163 Re-using ../asassn_transients_list.txt '../asassn_transients_list.txt' -> 'asassn_transients_list.txt' Re-using ../tns_transients_list.txt '../tns_transients_list.txt' -> 'tns_transients_list.txt' Plate-solving the images 'tocp_transients_list.txt' -> '../tocp_transients_list.txt' wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits exists and is non-empty Saving wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits to local_wcs_cache/ 'wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits' -> 'local_wcs_cache/wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits' wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits exists and is non-empty Saving wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits to local_wcs_cache/ 'wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits' -> 'local_wcs_cache/wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits' wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits exists and is non-empty Saving wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits to local_wcs_cache/ 'wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits' -> 'local_wcs_cache/wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits' wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits exists and is non-empty Saving wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits to local_wcs_cache/ 'wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits' -> 'local_wcs_cache/wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits' ################################### # fov_of_wcs_calibrated_image.sh output for wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits (1st reference image) verification OK: wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits Image size: 937.1'x624.0' 15.6(deg)x10.4(deg) 9576x6388 pix Image scale: 5.87"/pix along the X axis and 5.86"/pix along the Y axis Image center: 17:08:34.611 +61:59:42.08 J2000 4789.000 3195.000 ################################### The image scale is 5.87"/pix, setting the soft and hard astrometric limits for filtering second-epoch detections: 5.9" and 8.8" ################################### # fov_of_wcs_calibrated_image.sh output for wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits (1st new image) verification OK: wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Image size: 937.2'x624.1' 15.6(deg)x10.4(deg) 9576x6388 pix Image scale: 5.87"/pix along the X axis and 5.86"/pix along the Y axis Image center: 17:08:36.434 +61:59:26.42 J2000 4789.000 3195.000 ################################### ################################### # Check the image center offset between the reference and the first second-epoch image (pointing accuracy) Reference image center 17:08:34.611 +61:59:42.08 Second-epoch image center 17:08:36.434 +61:59:26.42 Angular distance between the image centers 0.0056 deg. Soft limit: 0.50 deg. Hard limit: 1.00 deg. ################################### ################################### # fov_of_wcs_calibrated_image.sh output for wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits (2nd new image) verification OK: wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits Image size: 937.2'x624.1' 15.6(deg)x10.4(deg) 9576x6388 pix Image scale: 5.87"/pix along the X axis and 5.86"/pix along the Y axis Image center: 17:08:33.574 +61:59:45.91 J2000 4789.000 3195.000 ################################### ################################### # Check the image center offset between the reference and the second second-epoch image (pointing accuracy) Reference image center 17:08:34.611 +61:59:42.08 Second-epoch image center 17:08:33.574 +61:59:45.91 Angular distance between the image centers 0.0023 deg. ################################### ################################### # Check the image center offset between the first and the second second-epoch image (shift should be applied between the second-epoch images) Second-epoch first image center 17:08:36.434 +61:59:26.42 Second-epoch second image center 17:08:33.574 +61:59:45.91 Angular distance between the image centers 0.00779 deg. ################################### Running solve_plate_with_UCAC5... Preparing for ar aprallel run Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits &> /tmp/tmp.zrYpUISqUG Parallel run for /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits &> /tmp/tmp.ym9oSawSY5 Parallel run for /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits &> /tmp/tmp.z2T6VMIxkg Parallel run for /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits &> /tmp/tmp.j3ApgdlPKy Parallel run for /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits Calibrating the magnitude scale Found non-empty wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits ____ Start of magnitude calibration ____ PHOTOMETRIC_CALIBRATION=TYCHO2_V Calibrating the magnitude scale with Tycho-2 stars util/transients/transient_factory_test31.sh is checking for the presence of non-empty wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits and wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat wait (drain background util/solve_plate_with_UCAC5 jobs before Tycho-2 calibration -- avoids wcs_.fits write race) Tycho-2 catalog is found at lib/catalogs/tycho2 Tycho-2 catalog and the derived bright star exclusion list are ready Checking for the presence of non-empty wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits and wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat Found non-empty wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits and wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat The reference image (wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits) and catalog (wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat) found 'wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat' -> 'wcsmag.cat' Read 12417 stars from the SExtractor catalog wcsmag.cat Detected star coordinate range: RA 237.8607 to 276.6328 deg, Dec +55.9095 to +67.2593 deg Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.00 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.01 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.02 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.03 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.04 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.05 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.06 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.07 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.08 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.09 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.10 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.11 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.12 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.13 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.14 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.15 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.16 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.17 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.18 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.19 Tycho-2 catalog search boundaries: RA 237.8607 to 276.6328 deg, Dec 55.9095 to 67.2593 deg Loaded 9265 Tycho-2 stars within the image boundaries (VT and BT non-zero). Relation between the catalog and instrumental magnitudes is written to calib.txt Stars used for magnitude calibration (good matches): 6067 out of 6312 total matches. Matched with Tycho-2 6312 out of 12417 detected stars. The calibration function type and coefficients are written to calib.txt_param util/calibrate_magnitude_scale 0.000000 1.000000 22.773800 a=0.000000 b=1.000000 c=22.773800 From vast_summary.log: estimated ref. image limiting mag.: -7.36 Updating vast_summary.log: Estimated ref. image limiting mag.: 15.41 Updated vast_limiting_magnitude.log with calibrated magnitudes Working... Please, PLEASE, be patient!!! All lightcurves processed! =) Estimated ref. image limiting mag.: 15.41
Lightcurve magnitude calibration plot:

Preparing per-reference-image forced-photometry calibration (method=tycho2 band=V) Read 12417 stars from the SExtractor catalog wcsmag.cat Detected star coordinate range: RA 237.8607 to 276.6328 deg, Dec +55.9095 to +67.2593 deg Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.00 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.01 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.02 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.03 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.04 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.05 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.06 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.07 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.08 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.09 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.10 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.11 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.12 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.13 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.14 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.15 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.16 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.17 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.18 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.19 Tycho-2 catalog search boundaries: RA 237.8607 to 276.6328 deg, Dec 55.9095 to 67.2593 deg Loaded 9265 Tycho-2 stars within the image boundaries (VT and BT non-zero). Relation between the catalog and instrumental magnitudes is written to calib.txt Stars used for magnitude calibration (good matches): 6067 out of 6312 total matches. Matched with Tycho-2 6312 out of 12417 detected stars. util/calibrate_single_image_with_tycho2.sh: calibrated wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits via Tycho-2
Single-image forced-photometry magnitude calibration plot for wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits:

Forced-photometry filter: calibrated wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits -> calib.txt_param_ref_wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits (aperture=6.2) Read 12355 stars from the SExtractor catalog wcsmag.cat Detected star coordinate range: RA 237.8606 to 276.6324 deg, Dec +55.9095 to +67.2524 deg Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.00 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.01 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.02 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.03 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.04 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.05 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.06 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.07 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.08 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.09 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.10 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.11 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.12 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.13 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.14 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.15 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.16 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.17 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.18 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.19 Tycho-2 catalog search boundaries: RA 237.8606 to 276.6324 deg, Dec 55.9095 to 67.2524 deg Loaded 9256 Tycho-2 stars within the image boundaries (VT and BT non-zero). Relation between the catalog and instrumental magnitudes is written to calib.txt Stars used for magnitude calibration (good matches): 6050 out of 6317 total matches. Matched with Tycho-2 6317 out of 12355 detected stars. util/calibrate_single_image_with_tycho2.sh: calibrated wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits via Tycho-2
Single-image forced-photometry magnitude calibration plot for wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits:

Forced-photometry filter: calibrated wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits -> calib.txt_param_ref_wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits (aperture=6.2) ____ End of magnitude calibration ____ Applying consolidated magnitude filters... Preparing the exclusion lists for this field Done with filtering Found 7 candidate transients before the final filtering. (Hard limit: 8000) Median FWHM seeing for isolated stars: 2.3 pix Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits 2.3 pix Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits 2.3 pix fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits 2.3 pix fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits 2.3 pix wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits 2.3 pix wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits Limiting magnitude estimates: 15.4 mag. Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits 15.4 mag. Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits 15.3 mag. fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits 15.3 mag. fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits All-image limiting magnitude estimate: 15.3 (SNR ) 12.3 (80% of stars) with default.sex.telephoto_lens_onlybrightstars_v1 The first estimate is the magnitude of a star detected with a signal-to-noise ratio of following Karpov (2025, Acta Polytechnica, 65, 50). This value should be representative of the faintest stars clearly visible in the image. The brighter of the limiting magnitude estimates for the two second-epoch images is reported here. The second estimate is the 80th percentile of the magnitude distribution of stars detected on all four images. This value is representative of the faintest object that may enter the candidate transients list. The hard cut-off for the candidate transients is 15.0 mag. Waiting for UCAC5 plate solver wait ############ /tmp/tmp.zrYpUISqUG (6) ############ Parsing command line arguments... The guess is based on the existing WCS header. Trying to blindly solve the plate (local solve-field or remote server)... /data_ssd/NMW-TexasTech/workdir/vast_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits 571.0 Entering WCS image calibration mode. ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits verification OK: /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits It's a known telescope with plate solutions that are supposed to be good. The input image /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits has a WCS header - will blindly trust it is good... '/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits' -> 'wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits' FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits WCS_IMAGE_NAME=wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits WCS-calibrated image found: wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits Checking if the catalog wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat corresponding to the image wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits alredy exist and is non-empty... Catalog wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat corresponding to the image wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits found. The catalog is in the new format, as expected. The plate-solved (WCS-calibrated) image is saved to wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits WCS catalog name: wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=0, blended=703, passed=12417 Got 12417 stars (including 11703 good ones) from the SExtractor catalog wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat util/solve_plate_with_UCAC5 got 12417 stars from the SExtractor catalog Updated FoV from the plate-solved image: 937.1' Seting catalog search parameters based on the expected field of view 937.1 arcmin UCAC5 catalog search parameters: catalog_search_parameters->search_radius_deg= 0.013015 (46.9 arcsec) catalog_search_parameters->brightest_mag= 1.00 catalog_search_parameters->faintest_mag= 13.50 catalog_search_parameters->search_radius_second_step_deg 0.010412 (37.5 arcsec) ITERATION 01 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 Reading UCAC5 zone files... Searching UCAC5 zones 729 to 788 (Dec 55.9 to 67.3) Done reading UCAC5 zone files... Matched 969 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Correcting the measured astrometric positions... Accuracy estimation diagnostic: 969 matched stars entering correct_measured_positions(), 960 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.49" Removing outliers... Correcting the measured astrometric positions... Accuracy estimation diagnostic: 969 matched stars entering correct_measured_positions(), 12199 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.49" ITERATION 02 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 Reading UCAC5 zone files... Searching UCAC5 zones 729 to 788 (Dec 55.9 to 67.3) Done reading UCAC5 zone files... Matched 969 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Accuracy estimation diagnostic: 969 matched stars entering correct_measured_positions(), 12200 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.49" Accuracy estimation diagnostic: 969 matched stars entering correct_measured_positions(), 12200 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.55" Excluding outliers - 969 stars left (next iteration limit 1065) Stop iterations. The field is successfully solved and matched with the astrometric catalog! :) WCS_QUALITY_DIAG: file=Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits N_match=969 sigma_overall_arcsec=0.521 sigma_q1_arcsec=0.322 sigma_q2_arcsec=0.700 sigma_q3_arcsec=0.399 sigma_q4_arcsec=0.719 n_q1=208 n_q2=269 n_q3=201 n_q4=291 worst_quadrant_to_overall_ratio=1.380 The image catalog is written to wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat.ucac5 The DS9 region file with the matched stars is written to wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat.ds9.reg You may view it with the command: ds9 /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits -region wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat.ds9.reg The astrometric residuals vector field is written to wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat.astrometric_residuals Option '-n' not using photometric catalogs, just stick with astrometry opt '-i': 2 is the maximum number of iterations ############ /tmp/tmp.ym9oSawSY5 (6) ############ Parsing command line arguments... The guess is based on the existing WCS header. Trying to blindly solve the plate (local solve-field or remote server)... /data_ssd/NMW-TexasTech/workdir/vast_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits 571.0 Entering WCS image calibration mode. ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits verification OK: /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits It's a known telescope with plate solutions that are supposed to be good. The input image /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits has a WCS header - will blindly trust it is good... '/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits' -> 'wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits' FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits WCS_IMAGE_NAME=wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits WCS-calibrated image found: wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits Checking if the catalog wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits.wcscat corresponding to the image wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits alredy exist and is non-empty... Catalog wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits.wcscat corresponding to the image wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits found. The catalog is in the new format, as expected. The plate-solved (WCS-calibrated) image is saved to wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits WCS catalog name: wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits.wcscat SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=0, blended=723, passed=12355 Got 12355 stars (including 11619 good ones) from the SExtractor catalog wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits.wcscat util/solve_plate_with_UCAC5 got 12355 stars from the SExtractor catalog Updated FoV from the plate-solved image: 937.1' Seting catalog search parameters based on the expected field of view 937.1 arcmin UCAC5 catalog search parameters: catalog_search_parameters->search_radius_deg= 0.013015 (46.9 arcsec) catalog_search_parameters->brightest_mag= 1.00 catalog_search_parameters->faintest_mag= 13.50 catalog_search_parameters->search_radius_second_step_deg 0.010412 (37.5 arcsec) ITERATION 01 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 Reading UCAC5 zone files... Searching UCAC5 zones 729 to 788 (Dec 55.9 to 67.3) Done reading UCAC5 zone files... Matched 970 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Correcting the measured astrometric positions... Accuracy estimation diagnostic: 970 matched stars entering correct_measured_positions(), 963 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.48" Removing outliers... Correcting the measured astrometric positions... Accuracy estimation diagnostic: 970 matched stars entering correct_measured_positions(), 12128 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.49" ITERATION 02 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 Reading UCAC5 zone files... Searching UCAC5 zones 729 to 788 (Dec 55.9 to 67.3) Done reading UCAC5 zone files... Matched 970 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Accuracy estimation diagnostic: 970 matched stars entering correct_measured_positions(), 12128 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.50" Accuracy estimation diagnostic: 970 matched stars entering correct_measured_positions(), 12128 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.54" Excluding outliers - 970 stars left (next iteration limit 1067) Stop iterations. The field is successfully solved and matched with the astrometric catalog! :) WCS_QUALITY_DIAG: file=Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits N_match=970 sigma_overall_arcsec=0.527 sigma_q1_arcsec=0.344 sigma_q2_arcsec=0.610 sigma_q3_arcsec=0.367 sigma_q4_arcsec=0.760 n_q1=210 n_q2=275 n_q3=201 n_q4=284 worst_quadrant_to_overall_ratio=1.443 The image catalog is written to wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits.wcscat.ucac5 The DS9 region file with the matched stars is written to wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits.wcscat.ds9.reg You may view it with the command: ds9 /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits -region wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits.wcscat.ds9.reg The astrometric residuals vector field is written to wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits.wcscat.astrometric_residuals Option '-n' not using photometric catalogs, just stick with astrometry opt '-i': 2 is the maximum number of iterations ############ /tmp/tmp.z2T6VMIxkg (6) ############ Parsing command line arguments... The minor axis of the CCD chip should be 24.0 mm based on the derived pixel size of 3.8 um Internal estimated FoV 605.3' The guess is based on the FOCALLEN keyword. Trying to blindly solve the plate (local solve-field or remote server)... /data_ssd/NMW-TexasTech/workdir/vast_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits 605.0 Entering WCS image calibration mode. ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits verification OK: /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits It's not one of the telescopes that are know to produce images with good WCS solutions - will try to re-solve! FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits WCS_IMAGE_NAME=wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits WCS-calibrated image found: wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Checking if the catalog wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits.wcscat corresponding to the image wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits alredy exist and is non-empty... Catalog wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits.wcscat corresponding to the image wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits found. The catalog is in the new format, as expected. The plate-solved (WCS-calibrated) image is saved to wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits WCS catalog name: wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits.wcscat SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=0, blended=705, passed=11048 Got 11048 stars (including 10329 good ones) from the SExtractor catalog wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits.wcscat util/solve_plate_with_UCAC5 got 11048 stars from the SExtractor catalog Updated FoV from the plate-solved image: 937.2' Seting catalog search parameters based on the expected field of view 937.2 arcmin UCAC5 catalog search parameters: catalog_search_parameters->search_radius_deg= 0.013017 (46.9 arcsec) catalog_search_parameters->brightest_mag= 1.00 catalog_search_parameters->faintest_mag= 13.50 catalog_search_parameters->search_radius_second_step_deg 0.010413 (37.5 arcsec) ITERATION 01 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 Reading UCAC5 zone files... Searching UCAC5 zones 729 to 788 (Dec 55.9 to 67.3) Done reading UCAC5 zone files... Matched 973 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Correcting the measured astrometric positions... Accuracy estimation diagnostic: 973 matched stars entering correct_measured_positions(), 970 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.46" Removing outliers... Correcting the measured astrometric positions... Accuracy estimation diagnostic: 973 matched stars entering correct_measured_positions(), 10912 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.44" ITERATION 02 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 Reading UCAC5 zone files... Searching UCAC5 zones 729 to 788 (Dec 55.9 to 67.3) Done reading UCAC5 zone files... Matched 973 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Accuracy estimation diagnostic: 973 matched stars entering correct_measured_positions(), 10911 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.45" Accuracy estimation diagnostic: 973 matched stars entering correct_measured_positions(), 10911 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.48" Excluding outliers - 973 stars left (next iteration limit 1070) Stop iterations. The field is successfully solved and matched with the astrometric catalog! :) WCS_QUALITY_DIAG: file=fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits N_match=973 sigma_overall_arcsec=0.459 sigma_q1_arcsec=0.422 sigma_q2_arcsec=0.589 sigma_q3_arcsec=0.457 sigma_q4_arcsec=0.418 n_q1=258 n_q2=252 n_q3=232 n_q4=231 worst_quadrant_to_overall_ratio=1.282 The image catalog is written to wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits.wcscat.ucac5 The DS9 region file with the matched stars is written to wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits.wcscat.ds9.reg You may view it with the command: ds9 /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits -region wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits.wcscat.ds9.reg The astrometric residuals vector field is written to wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits.wcscat.astrometric_residuals Option '-n' not using photometric catalogs, just stick with astrometry opt '-i': 2 is the maximum number of iterations ############ /tmp/tmp.j3ApgdlPKy (6) ############ Parsing command line arguments... The minor axis of the CCD chip should be 24.0 mm based on the derived pixel size of 3.8 um Internal estimated FoV 605.3' The guess is based on the FOCALLEN keyword. Trying to blindly solve the plate (local solve-field or remote server)... /data_ssd/NMW-TexasTech/workdir/vast_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits 605.0 Entering WCS image calibration mode. ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits verification OK: /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits It's not one of the telescopes that are know to produce images with good WCS solutions - will try to re-solve! FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits WCS_IMAGE_NAME=wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits WCS-calibrated image found: wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits Checking if the catalog wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat corresponding to the image wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits alredy exist and is non-empty... Catalog wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat corresponding to the image wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits found. The catalog is in the new format, as expected. The plate-solved (WCS-calibrated) image is saved to wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits WCS catalog name: wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=0, blended=730, passed=10895 Got 10895 stars (including 10157 good ones) from the SExtractor catalog wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat util/solve_plate_with_UCAC5 got 10895 stars from the SExtractor catalog Updated FoV from the plate-solved image: 937.2' Seting catalog search parameters based on the expected field of view 937.2 arcmin UCAC5 catalog search parameters: catalog_search_parameters->search_radius_deg= 0.013017 (46.9 arcsec) catalog_search_parameters->brightest_mag= 1.00 catalog_search_parameters->faintest_mag= 13.50 catalog_search_parameters->search_radius_second_step_deg 0.010413 (37.5 arcsec) ITERATION 01 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 Reading UCAC5 zone files... Searching UCAC5 zones 729 to 788 (Dec 55.9 to 67.3) Done reading UCAC5 zone files... Matched 975 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Correcting the measured astrometric positions... Accuracy estimation diagnostic: 975 matched stars entering correct_measured_positions(), 971 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.49" Removing outliers... Correcting the measured astrometric positions... Accuracy estimation diagnostic: 975 matched stars entering correct_measured_positions(), 10770 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.47" ITERATION 02 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 Reading UCAC5 zone files... Searching UCAC5 zones 729 to 788 (Dec 55.9 to 67.3) Done reading UCAC5 zone files... Matched 975 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Accuracy estimation diagnostic: 975 matched stars entering correct_measured_positions(), 10770 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.47" Accuracy estimation diagnostic: 975 matched stars entering correct_measured_positions(), 10770 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.51" Excluding outliers - 975 stars left (next iteration limit 1072) Stop iterations. The field is successfully solved and matched with the astrometric catalog! :) WCS_QUALITY_DIAG: file=fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits N_match=975 sigma_overall_arcsec=0.498 sigma_q1_arcsec=0.441 sigma_q2_arcsec=0.633 sigma_q3_arcsec=0.504 sigma_q4_arcsec=0.462 n_q1=260 n_q2=248 n_q3=233 n_q4=234 worst_quadrant_to_overall_ratio=1.271 The image catalog is written to wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat.ucac5 The DS9 region file with the matched stars is written to wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat.ds9.reg You may view it with the command: ds9 /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits -region wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat.ds9.reg The astrometric residuals vector field is written to wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat.astrometric_residuals Option '-n' not using photometric catalogs, just stick with astrometry opt '-i': 2 is the maximum number of iterations ################################### # Pre-local-correction WCS quality summary (see WCS_QUALITY_DIAG lines above) ref1=Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits sigma_overall=0.521 worst_q_ratio=1.380 ref2=Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits sigma_overall=0.527 worst_q_ratio=1.443 new1=fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits sigma_overall=0.459 worst_q_ratio=1.282 new2=fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits sigma_overall=0.498 worst_q_ratio=1.271 reference average sigma_overall=0.524 worst_q_ratio=1.4115 warn-on-ratio threshold: 2.0x reference ###################################
Astrometric residual vector field (catalog-matched stars):
plot_astrometric_residuals_xy.py: wrote wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302_astrometric_residuals.png (969 matched stars from wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat.astrometric_residuals, image 9576x6388, median residual 0.45 arcsec)
plot_astrometric_residuals_xy.py: wrote wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303_astrometric_residuals.png (970 matched stars from wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits.wcscat.astrometric_residuals, image 9576x6388, median residual 0.46 arcsec)
plot_astrometric_residuals_xy.py: wrote wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244_astrometric_residuals.png (973 matched stars from wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits.wcscat.astrometric_residuals, image 9576x6388, median residual 0.42 arcsec)
plot_astrometric_residuals_xy.py: wrote wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245_astrometric_residuals.png (975 matched stars from wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat.astrometric_residuals, image 9576x6388, median residual 0.45 arcsec)
Copying WCS-calibrated images back to input directory Saving fully-calibrated image wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits INFO: FPACK_FULLY_CALIBRATED_IMAGE=no (not compressing the image) 'wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits' -> '/data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits' Saving fully-calibrated image wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits INFO: FPACK_FULLY_CALIBRATED_IMAGE=no (not compressing the image) 'wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits' -> '/data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits' Preparing the HTML report for the field Dra-07-Q2b1x1 with default.sex.telephoto_lens_onlybrightstars_v1 Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 16:50:05.34 +59:12:19.6: 12.47 +/- 0.01 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 16:39:18.03 +59:46:46.1: 12.54 +/- 0.02 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 16:33:10.42 +63:22:56.8: 12.63 +/- 0.02 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 17:20:01.58 +63:16:00.2: 10.52 +/- 0.00 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 16:48:48.13 +62:30:02.1: 12.59 +/- 0.02 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 16:39:18.03 +59:46:46.1: 12.56 +/- 0.01 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 16:33:10.42 +63:22:56.8: 12.63 +/- 0.02 detection Forced photometry reference-image weighted average: 12.55 +/- 0.01 Forced photometry filter REJECTED candidate at 16:39:18.03 +59:46:46.1: ref_mag=12.55 +/- 0.01 new_mean_mag=12.5031 delta=0.05 (need > 0.90) Forced photometry reference-image weighted average: 12.63 +/- 0.01 Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 16:50:05.34 +59:12:19.6: 12.46 +/- 0.01 detection Forced photometry filter REJECTED candidate at 16:33:10.42 +63:22:56.8: ref_mag=12.63 +/- 0.01 new_mean_mag=12.5374 delta=0.09 (need > 0.90) Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 16:48:48.13 +62:30:02.1: 12.57 +/- 0.01 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 17:20:01.58 +63:16:00.2: 10.54 +/- 0.00 detection Forced photometry reference-image weighted average: 12.47 +/- 0.01 Forced photometry reference-image weighted average: 10.53 +/- 0.00 Forced photometry reference-image weighted average: 12.58 +/- 0.01 Forced photometry filter REJECTED candidate at 16:50:05.34 +59:12:19.6: ref_mag=12.47 +/- 0.01 new_mean_mag=12.4449 delta=0.02 (need > 0.90) Forced photometry filter REJECTED candidate at 16:48:48.13 +62:30:02.1: ref_mag=12.58 +/- 0.01 new_mean_mag=12.5047 delta=0.08 (need > 0.90) Forced photometry filter REJECTED candidate at 17:20:01.58 +63:16:00.2: ref_mag=10.53 +/- 0.00 new_mean_mag=10.9819 delta=-0.45 (need > 0.90) make_report_in_HTML.sh Phase 1 (network queries): 1s Pre-generating preview images in parallel... Done pre-generating preview images. Pre-generating finding charts in parallel... Done pre-generating finding charts. make_report_in_HTML.sh Pre-generation: 0s xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 20361_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 20361_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 2   2026 06 11.34551    2461202.84551    11.78    16:41:49.05 +64:06:27.2   6581 1861   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits **** FOUND 16:41:48.97 +64:06:27.8 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 20362_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 20362_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 2   2026 06 11.34551    2461202.84551    11.51    17:20:28.17 +57:53:05.7   3781 5644   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits **** FOUND 17:20:28.23 +57:53:05.7 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 21046_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 21046_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 1   2026 06 11.34493    2461202.84493    10.94    17:20:01.63 +63:16:00.3   4029 2391   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Discovery image 2   2026 06 11.34551    2461202.84551    11.03    17:20:01.54 +63:16:00.2   4026 2394   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 22602_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 22602_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 1   2026 06 11.34493    2461202.84493    12.45    16:50:05.34 +59:12:19.9   6189 4858   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Discovery image 2   2026 06 11.34551    2461202.84551    12.44    16:50:05.35 +59:12:19.3   6186 4862   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 22675_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 22675_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 1   2026 06 11.34493    2461202.84493    12.50    16:39:18.03 +59:46:45.9   6993 4454   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Discovery image 2   2026 06 11.34551    2461202.84551    12.51    16:39:18.03 +59:46:46.3   6989 4457   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 22677_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 22677_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 1   2026 06 11.34493    2461202.84493    12.50    16:48:48.11 +62:30:02.0   6177 2862   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Discovery image 2   2026 06 11.34551    2461202.84551    12.51    16:48:48.16 +62:30:02.2   6173 2865   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 22741_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 22741_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 1   2026 06 11.34493    2461202.84493    12.53    16:33:10.42 +63:22:57.2   7205 2236   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Discovery image 2   2026 06 11.34551    2461202.84551    12.54    16:33:10.41 +63:22:56.4   7202 2240   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits make_report_in_HTML.sh Phase 2 (HTML assembly): 0s make_report_in_HTML.sh TOTAL: 1s Prepared the HTML report for the field Dra-07-Q2b1x1 with default.sex.telephoto_lens_onlybrightstars_v1 *------ done with default.sex.telephoto_lens_onlybrightstars_v1 ------* #### The local exclusion list is exclusion_list_local.txt #### wait *------ default.sex.telephoto_lens_vSTL ------* 'default.sex.telephoto_lens_vSTL' -> 'default.sex' Starting VaST with default.sex.telephoto_lens_vSTL ./vast --norotation --noflagimage --starmatchraius 4 --matchstarnumber 500 --selectbestaperture --sysrem 0 --type 4 --maxsextractorflag 99 --UTC --nofind --nojdkeyword /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits SExtractor catalog cache: saved Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.cat to cache SExtractor catalog cache: saved Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits.cat to cache VaST run complete with default.sex.telephoto_lens_vSTL The four input images were /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits Checking WCS cache directory local_wcs_cache Found WCS cache directory local_wcs_cache Creating symlink local_wcs_cache/wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits Creating symlink local_wcs_cache/wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits Creating symlink local_wcs_cache/wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Creating symlink local_wcs_cache/wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits Creating symlink local_wcs_cache/exclusion_list.txt Checking WCS cache directory /mnt/usb/NMW_NG/solved_reference_images Found WCS cache directory /mnt/usb/NMW_NG/solved_reference_images Checking WCS cache directory /home/NMW_web_upload/solved_reference_images Checking WCS cache directory /dataX/kirx/NMW_NG_rt3_autumn2019/solved_reference_images Plate-solving the images wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits exists and is non-empty wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits exists and is non-empty wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits exists and is non-empty wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits exists and is non-empty ################################### # fov_of_wcs_calibrated_image.sh output for wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits (1st reference image) verification OK: wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits Image size: 937.1'x624.0' 15.6(deg)x10.4(deg) 9576x6388 pix Image scale: 5.87"/pix along the X axis and 5.86"/pix along the Y axis Image center: 17:08:34.611 +61:59:42.08 J2000 4789.000 3195.000 ################################### The image scale is 5.87"/pix, setting the soft and hard astrometric limits for filtering second-epoch detections: 5.9" and 8.8" ################################### # fov_of_wcs_calibrated_image.sh output for wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits (1st new image) verification OK: wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Image size: 937.2'x624.1' 15.6(deg)x10.4(deg) 9576x6388 pix Image scale: 5.87"/pix along the X axis and 5.86"/pix along the Y axis Image center: 17:08:36.434 +61:59:26.42 J2000 4789.000 3195.000 ################################### ################################### # Check the image center offset between the reference and the first second-epoch image (pointing accuracy) Reference image center 17:08:34.611 +61:59:42.08 Second-epoch image center 17:08:36.434 +61:59:26.42 Angular distance between the image centers 0.0056 deg. Soft limit: 0.50 deg. Hard limit: 1.00 deg. ################################### ################################### # fov_of_wcs_calibrated_image.sh output for wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits (2nd new image) verification OK: wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits Image size: 937.2'x624.1' 15.6(deg)x10.4(deg) 9576x6388 pix Image scale: 5.87"/pix along the X axis and 5.86"/pix along the Y axis Image center: 17:08:33.574 +61:59:45.91 J2000 4789.000 3195.000 ################################### ################################### # Check the image center offset between the reference and the second second-epoch image (pointing accuracy) Reference image center 17:08:34.611 +61:59:42.08 Second-epoch image center 17:08:33.574 +61:59:45.91 Angular distance between the image centers 0.0023 deg. ################################### ################################### # Check the image center offset between the first and the second second-epoch image (shift should be applied between the second-epoch images) Second-epoch first image center 17:08:36.434 +61:59:26.42 Second-epoch second image center 17:08:33.574 +61:59:45.91 Angular distance between the image centers 0.00779 deg. ################################### Running solve_plate_with_UCAC5... Preparing for ar aprallel run Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits &> /tmp/tmp.jTb7SNJoJU Parallel run for /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits &> /tmp/tmp.OqcKVf6hoT Parallel run for /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits &> /tmp/tmp.YtFXtH6rOI Parallel run for /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits &> /tmp/tmp.RtwRRdQ0NS Parallel run for /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits Calibrating the magnitude scale Found non-empty wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits ____ Start of magnitude calibration ____ PHOTOMETRIC_CALIBRATION=TYCHO2_V Calibrating the magnitude scale with Tycho-2 stars util/transients/transient_factory_test31.sh is checking for the presence of non-empty wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits and wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat wait (drain background util/solve_plate_with_UCAC5 jobs before Tycho-2 calibration -- avoids wcs_.fits write race) Tycho-2 catalog is found at lib/catalogs/tycho2 Tycho-2 catalog and the derived bright star exclusion list are ready Checking for the presence of non-empty wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits and wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat Found non-empty wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits and wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat The reference image (wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits) and catalog (wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat) found 'wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat' -> 'wcsmag.cat' Read 63914 stars from the SExtractor catalog wcsmag.cat Detected star coordinate range: RA 237.8607 to 276.6327 deg, Dec +55.8792 to +67.2592 deg Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.00 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.01 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.02 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.03 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.04 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.05 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.06 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.07 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.08 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.09 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.10 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.11 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.12 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.13 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.14 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.15 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.16 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.17 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.18 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.19 Tycho-2 catalog search boundaries: RA 237.8607 to 276.6327 deg, Dec 55.8792 to 67.2592 deg Loaded 9293 Tycho-2 stars within the image boundaries (VT and BT non-zero). Relation between the catalog and instrumental magnitudes is written to calib.txt Stars used for magnitude calibration (good matches): 5638 out of 6334 total matches. Matched with Tycho-2 6334 out of 63914 detected stars. The calibration function type and coefficients are written to calib.txt_param util/calibrate_magnitude_scale 0.000000 1.000000 22.653550 a=0.000000 b=1.000000 c=22.653550 From vast_summary.log: estimated ref. image limiting mag.: -7.08 Updating vast_summary.log: Estimated ref. image limiting mag.: 15.57 Updated vast_limiting_magnitude.log with calibrated magnitudes Working... Please, PLEASE, be patient!!! All lightcurves processed! =) Estimated ref. image limiting mag.: 15.57
Lightcurve magnitude calibration plot:

Preparing per-reference-image forced-photometry calibration (method=tycho2 band=V) Read 63914 stars from the SExtractor catalog wcsmag.cat Detected star coordinate range: RA 237.8607 to 276.6327 deg, Dec +55.8792 to +67.2592 deg Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.00 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.01 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.02 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.03 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.04 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.05 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.06 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.07 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.08 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.09 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.10 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.11 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.12 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.13 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.14 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.15 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.16 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.17 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.18 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.19 Tycho-2 catalog search boundaries: RA 237.8607 to 276.6327 deg, Dec 55.8792 to 67.2592 deg Loaded 9293 Tycho-2 stars within the image boundaries (VT and BT non-zero). Relation between the catalog and instrumental magnitudes is written to calib.txt Stars used for magnitude calibration (good matches): 5638 out of 6334 total matches. Matched with Tycho-2 6334 out of 63914 detected stars. util/calibrate_single_image_with_tycho2.sh: calibrated wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits via Tycho-2
Single-image forced-photometry magnitude calibration plot for wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits:

Forced-photometry filter: calibrated wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits -> calib.txt_param_ref_wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits (aperture=4.9) Read 64100 stars from the SExtractor catalog wcsmag.cat Detected star coordinate range: RA 237.8607 to 276.6331 deg, Dec +55.8769 to +67.2570 deg Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.00 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.01 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.02 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.03 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.04 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.05 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.06 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.07 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.08 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.09 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.10 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.11 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.12 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.13 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.14 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.15 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.16 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.17 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.18 Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.19 Tycho-2 catalog search boundaries: RA 237.8607 to 276.6331 deg, Dec 55.8769 to 67.2570 deg Loaded 9293 Tycho-2 stars within the image boundaries (VT and BT non-zero). Relation between the catalog and instrumental magnitudes is written to calib.txt Stars used for magnitude calibration (good matches): 5609 out of 6336 total matches. Matched with Tycho-2 6336 out of 64100 detected stars. util/calibrate_single_image_with_tycho2.sh: calibrated wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits via Tycho-2
Single-image forced-photometry magnitude calibration plot for wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits:

Forced-photometry filter: calibrated wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits -> calib.txt_param_ref_wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits (aperture=4.9) ____ End of magnitude calibration ____ Applying consolidated magnitude filters... Preparing the exclusion lists for this field Done with filtering Found 49 candidate transients before the final filtering. (Hard limit: 8000) Median FWHM seeing for isolated stars: 2.2 pix Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits 2.2 pix Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits 2.1 pix fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits 2.1 pix fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits 2.2 pix wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits 2.2 pix wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits Limiting magnitude estimates: 15.6 mag. Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits 15.6 mag. Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits 15.5 mag. fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits 15.5 mag. fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits All-image limiting magnitude estimate: 15.5 (SNR ) 14.8 (80% of stars) with default.sex.telephoto_lens_vSTL The first estimate is the magnitude of a star detected with a signal-to-noise ratio of following Karpov (2025, Acta Polytechnica, 65, 50). This value should be representative of the faintest stars clearly visible in the image. The brighter of the limiting magnitude estimates for the two second-epoch images is reported here. The second estimate is the 80th percentile of the magnitude distribution of stars detected on all four images. This value is representative of the faintest object that may enter the candidate transients list. The hard cut-off for the candidate transients is 15.0 mag. Waiting for UCAC5 plate solver wait ############ /tmp/tmp.jTb7SNJoJU (6) ############ Parsing command line arguments... The guess is based on the existing WCS header. Trying to blindly solve the plate (local solve-field or remote server)... /data_ssd/NMW-TexasTech/workdir/vast_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits 571.0 Entering WCS image calibration mode. ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits verification OK: /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits It's a known telescope with plate solutions that are supposed to be good. The input image /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits has a WCS header - will blindly trust it is good... '/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits' -> 'wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits' FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits WCS_IMAGE_NAME=wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits WCS-calibrated image found: wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits Checking if the catalog wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat corresponding to the image wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits alredy exist and is non-empty... Catalog wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat corresponding to the image wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits found. The catalog is in the new format, as expected. The plate-solved (WCS-calibrated) image is saved to wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits WCS catalog name: wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=12, blended=4104, passed=63902 Got 63902 stars (including 59733 good ones) from the SExtractor catalog wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat util/solve_plate_with_UCAC5 got 63902 stars from the SExtractor catalog Updated FoV from the plate-solved image: 937.1' Seting catalog search parameters based on the expected field of view 937.1 arcmin UCAC5 catalog search parameters: catalog_search_parameters->search_radius_deg= 0.013015 (46.9 arcsec) catalog_search_parameters->brightest_mag= 1.00 catalog_search_parameters->faintest_mag= 13.50 catalog_search_parameters->search_radius_second_step_deg 0.010412 (37.5 arcsec) ITERATION 01 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 Reading UCAC5 zone files... Searching UCAC5 zones 729 to 788 (Dec 55.9 to 67.3) Done reading UCAC5 zone files... Matched 973 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Correcting the measured astrometric positions... Accuracy estimation diagnostic: 973 matched stars entering correct_measured_positions(), 965 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.46" Removing outliers... Correcting the measured astrometric positions... Accuracy estimation diagnostic: 973 matched stars entering correct_measured_positions(), 62935 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.46" ITERATION 02 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 Reading UCAC5 zone files... Searching UCAC5 zones 729 to 788 (Dec 55.9 to 67.3) Done reading UCAC5 zone files... Matched 973 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Accuracy estimation diagnostic: 972 matched stars entering correct_measured_positions(), 62936 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.47" Accuracy estimation diagnostic: 972 matched stars entering correct_measured_positions(), 62936 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.51" Excluding outliers - 972 stars left (next iteration limit 1070) Stop iterations. The field is successfully solved and matched with the astrometric catalog! :) WCS_QUALITY_DIAG: file=Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits N_match=972 sigma_overall_arcsec=0.499 sigma_q1_arcsec=0.336 sigma_q2_arcsec=0.697 sigma_q3_arcsec=0.382 sigma_q4_arcsec=0.672 n_q1=224 n_q2=260 n_q3=217 n_q4=271 worst_quadrant_to_overall_ratio=1.396 The image catalog is written to wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat.ucac5 The DS9 region file with the matched stars is written to wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat.ds9.reg You may view it with the command: ds9 /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits -region wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat.ds9.reg The astrometric residuals vector field is written to wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits.wcscat.astrometric_residuals Option '-n' not using photometric catalogs, just stick with astrometry opt '-i': 2 is the maximum number of iterations ############ /tmp/tmp.OqcKVf6hoT (6) ############ Parsing command line arguments... The guess is based on the existing WCS header. Trying to blindly solve the plate (local solve-field or remote server)... /data_ssd/NMW-TexasTech/workdir/vast_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits 571.0 Entering WCS image calibration mode. ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits verification OK: /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits It's a known telescope with plate solutions that are supposed to be good. The input image /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits has a WCS header - will blindly trust it is good... '/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits' -> 'wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits' FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits WCS_IMAGE_NAME=wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits WCS-calibrated image found: wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits Checking if the catalog wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits.wcscat corresponding to the image wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits alredy exist and is non-empty... Catalog wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits.wcscat corresponding to the image wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits found. The catalog is in the new format, as expected. The plate-solved (WCS-calibrated) image is saved to wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits WCS catalog name: wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits.wcscat SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=23, blended=4098, passed=64077 Got 64077 stars (including 59908 good ones) from the SExtractor catalog wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits.wcscat util/solve_plate_with_UCAC5 got 64077 stars from the SExtractor catalog Updated FoV from the plate-solved image: 937.1' Seting catalog search parameters based on the expected field of view 937.1 arcmin UCAC5 catalog search parameters: catalog_search_parameters->search_radius_deg= 0.013015 (46.9 arcsec) catalog_search_parameters->brightest_mag= 1.00 catalog_search_parameters->faintest_mag= 13.50 catalog_search_parameters->search_radius_second_step_deg 0.010412 (37.5 arcsec) ITERATION 01 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 Reading UCAC5 zone files... Searching UCAC5 zones 729 to 788 (Dec 55.9 to 67.3) Done reading UCAC5 zone files... Matched 976 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Correcting the measured astrometric positions... Accuracy estimation diagnostic: 976 matched stars entering correct_measured_positions(), 971 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.44" Removing outliers... Correcting the measured astrometric positions... Accuracy estimation diagnostic: 976 matched stars entering correct_measured_positions(), 63044 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.46" ITERATION 02 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 Reading UCAC5 zone files... Searching UCAC5 zones 729 to 788 (Dec 55.9 to 67.3) Done reading UCAC5 zone files... Matched 976 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Accuracy estimation diagnostic: 975 matched stars entering correct_measured_positions(), 63044 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.46" Accuracy estimation diagnostic: 975 matched stars entering correct_measured_positions(), 63044 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.51" Excluding outliers - 975 stars left (next iteration limit 1073) Stop iterations. The field is successfully solved and matched with the astrometric catalog! :) WCS_QUALITY_DIAG: file=Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits N_match=975 sigma_overall_arcsec=0.515 sigma_q1_arcsec=0.327 sigma_q2_arcsec=0.689 sigma_q3_arcsec=0.394 sigma_q4_arcsec=0.725 n_q1=226 n_q2=259 n_q3=221 n_q4=269 worst_quadrant_to_overall_ratio=1.407 The image catalog is written to wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits.wcscat.ucac5 The DS9 region file with the matched stars is written to wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits.wcscat.ds9.reg You may view it with the command: ds9 /data_ssd/NMW-TexasTech/reference_imgs/Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits -region wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits.wcscat.ds9.reg The astrometric residuals vector field is written to wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits.wcscat.astrometric_residuals Option '-n' not using photometric catalogs, just stick with astrometry opt '-i': 2 is the maximum number of iterations ############ /tmp/tmp.YtFXtH6rOI (6) ############ Parsing command line arguments... The minor axis of the CCD chip should be 24.0 mm based on the derived pixel size of 3.8 um Internal estimated FoV 605.3' The guess is based on the FOCALLEN keyword. Trying to blindly solve the plate (local solve-field or remote server)... /data_ssd/NMW-TexasTech/workdir/vast_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits 605.0 Entering WCS image calibration mode. ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits verification OK: /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits It's not one of the telescopes that are know to produce images with good WCS solutions - will try to re-solve! FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits WCS_IMAGE_NAME=wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits WCS-calibrated image found: wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Checking if the catalog wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits.wcscat corresponding to the image wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits alredy exist and is non-empty... Catalog wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits.wcscat corresponding to the image wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits found. The catalog is in the new format, as expected. The plate-solved (WCS-calibrated) image is saved to wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits WCS catalog name: wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits.wcscat SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=29, blended=3804, passed=63150 Got 63150 stars (including 59265 good ones) from the SExtractor catalog wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits.wcscat util/solve_plate_with_UCAC5 got 63150 stars from the SExtractor catalog Updated FoV from the plate-solved image: 937.2' Seting catalog search parameters based on the expected field of view 937.2 arcmin UCAC5 catalog search parameters: catalog_search_parameters->search_radius_deg= 0.013017 (46.9 arcsec) catalog_search_parameters->brightest_mag= 1.00 catalog_search_parameters->faintest_mag= 13.50 catalog_search_parameters->search_radius_second_step_deg 0.010413 (37.5 arcsec) ITERATION 01 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 Reading UCAC5 zone files... Searching UCAC5 zones 729 to 788 (Dec 55.9 to 67.3) Done reading UCAC5 zone files... Matched 971 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Correcting the measured astrometric positions... Accuracy estimation diagnostic: 971 matched stars entering correct_measured_positions(), 968 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.46" Removing outliers... Correcting the measured astrometric positions... Accuracy estimation diagnostic: 971 matched stars entering correct_measured_positions(), 62275 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.45" ITERATION 02 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 Reading UCAC5 zone files... Searching UCAC5 zones 729 to 788 (Dec 55.9 to 67.3) Done reading UCAC5 zone files... Matched 971 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Accuracy estimation diagnostic: 970 matched stars entering correct_measured_positions(), 62276 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.45" Accuracy estimation diagnostic: 970 matched stars entering correct_measured_positions(), 62276 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.47" Excluding outliers - 970 stars left (next iteration limit 1068) Stop iterations. The field is successfully solved and matched with the astrometric catalog! :) WCS_QUALITY_DIAG: file=fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits N_match=970 sigma_overall_arcsec=0.472 sigma_q1_arcsec=0.421 sigma_q2_arcsec=0.556 sigma_q3_arcsec=0.498 sigma_q4_arcsec=0.440 n_q1=245 n_q2=264 n_q3=222 n_q4=239 worst_quadrant_to_overall_ratio=1.178 The image catalog is written to wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits.wcscat.ucac5 The DS9 region file with the matched stars is written to wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits.wcscat.ds9.reg You may view it with the command: ds9 /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits -region wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits.wcscat.ds9.reg The astrometric residuals vector field is written to wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits.wcscat.astrometric_residuals Option '-n' not using photometric catalogs, just stick with astrometry opt '-i': 2 is the maximum number of iterations ############ /tmp/tmp.RtwRRdQ0NS (6) ############ Parsing command line arguments... The minor axis of the CCD chip should be 24.0 mm based on the derived pixel size of 3.8 um Internal estimated FoV 605.3' The guess is based on the FOCALLEN keyword. Trying to blindly solve the plate (local solve-field or remote server)... /data_ssd/NMW-TexasTech/workdir/vast_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits 605.0 Entering WCS image calibration mode. ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits verification OK: /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits It's not one of the telescopes that are know to produce images with good WCS solutions - will try to re-solve! FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits WCS_IMAGE_NAME=wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits WCS-calibrated image found: wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits Checking if the catalog wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat corresponding to the image wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits alredy exist and is non-empty... Catalog wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat corresponding to the image wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits found. The catalog is in the new format, as expected. The plate-solved (WCS-calibrated) image is saved to wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits WCS catalog name: wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=37, blended=3836, passed=63665 Got 63665 stars (including 59742 good ones) from the SExtractor catalog wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat util/solve_plate_with_UCAC5 got 63665 stars from the SExtractor catalog Updated FoV from the plate-solved image: 937.2' Seting catalog search parameters based on the expected field of view 937.2 arcmin UCAC5 catalog search parameters: catalog_search_parameters->search_radius_deg= 0.013017 (46.9 arcsec) catalog_search_parameters->brightest_mag= 1.00 catalog_search_parameters->faintest_mag= 13.50 catalog_search_parameters->search_radius_second_step_deg 0.010413 (37.5 arcsec) ITERATION 01 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 Reading UCAC5 zone files... Searching UCAC5 zones 729 to 788 (Dec 55.8 to 67.3) Done reading UCAC5 zone files... Matched 973 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Correcting the measured astrometric positions... Accuracy estimation diagnostic: 973 matched stars entering correct_measured_positions(), 971 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.49" Removing outliers... Correcting the measured astrometric positions... Accuracy estimation diagnostic: 973 matched stars entering correct_measured_positions(), 63056 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.48" ITERATION 02 -- talking to VizieR, this might be slow! UCAC5 search strategy: trying local copy first Found a local copy of UCAC5 Reading UCAC5 zone files... Searching UCAC5 zones 729 to 788 (Dec 55.8 to 67.3) Done reading UCAC5 zone files... Matched 973 stars with the local copy of UCAC5. The local UCAC5 search seems to be a success Accuracy estimation diagnostic: 972 matched stars entering correct_measured_positions(), 63055 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.48" Accuracy estimation diagnostic: 972 matched stars entering correct_measured_positions(), 63055 with non-zero local correction accuracy Estimated accuracy of the plate solution: 0.51" Excluding outliers - 972 stars left (next iteration limit 1070) Stop iterations. The field is successfully solved and matched with the astrometric catalog! :) WCS_QUALITY_DIAG: file=fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits N_match=972 sigma_overall_arcsec=0.491 sigma_q1_arcsec=0.440 sigma_q2_arcsec=0.605 sigma_q3_arcsec=0.522 sigma_q4_arcsec=0.480 n_q1=245 n_q2=265 n_q3=215 n_q4=247 worst_quadrant_to_overall_ratio=1.231 The image catalog is written to wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat.ucac5 The DS9 region file with the matched stars is written to wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat.ds9.reg You may view it with the command: ds9 /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits -region wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat.ds9.reg The astrometric residuals vector field is written to wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits.wcscat.astrometric_residuals Option '-n' not using photometric catalogs, just stick with astrometry opt '-i': 2 is the maximum number of iterations Skipping WCS quality comparison: not the first SExtractor pass (default.sex.telephoto_lens_vSTL) Copying WCS-calibrated images back to input directory Saving fully-calibrated image wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits INFO: FPACK_FULLY_CALIBRATED_IMAGE=no (not compressing the image) The destination file is already there - not rewriting /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Saving fully-calibrated image wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits INFO: FPACK_FULLY_CALIBRATED_IMAGE=no (not compressing the image) The destination file is already there - not rewriting /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/wcs_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits Preparing the HTML report for the field Dra-07-Q2b1x1 with default.sex.telephoto_lens_vSTL Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 17:42:12.07 +62:53:56.7: 15.08 +/- 0.13 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 17:19:52.02 +62:56:50.7: 14.47 +/- 0.07 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 16:48:05.66 +63:49:05.7: 14.42 +/- 0.07 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 16:41:49.99 +60:05:12.3: 14.73 +/- 0.09 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 16:35:09.84 +61:18:18.1: 14.70 +/- 0.10 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 17:13:12.45 +60:22:19.4: 14.88 +/- 0.11 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 17:41:22.31 +59:34:52.7: 14.35 +/- 0.07 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 17:29:33.01 +58:05:13.9: 14.84 +/- 0.12 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 17:30:40.20 +58:31:58.1: 13.80 +/- 0.04 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 16:34:16.24 +65:09:52.2: 14.46 +/- 0.08 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 16:48:05.66 +63:49:05.7: 14.45 +/- 0.07 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 17:42:12.07 +62:53:56.7: 15.04 +/- 0.12 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 17:19:52.02 +62:56:50.7: 14.32 +/- 0.06 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 16:41:49.99 +60:05:12.3: 14.53 +/- 0.08 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 16:35:09.84 +61:18:18.1: 14.75 +/- 0.10 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 17:13:12.45 +60:22:19.4: 15.00 +/- 0.12 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 17:29:33.01 +58:05:13.9: 14.92 +/- 0.13 detection Forced photometry reference-image weighted average: 14.44 +/- 0.05 Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 17:30:40.20 +58:31:58.1: 13.84 +/- 0.04 detection Forced photometry filter REJECTED candidate at 16:48:05.66 +63:49:05.7: ref_mag=14.44 +/- 0.05 new_mean_mag=14.7603 delta=-0.32 (need > 0.90) Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 17:41:22.31 +59:34:52.7: 14.56 +/- 0.08 detection Forced photometry reference-image weighted average: 14.88 +/- 0.09 Forced photometry reference-image weighted average: 14.93 +/- 0.08 Forced photometry reference-image weighted average: 14.73 +/- 0.07 Forced photometry reference-image weighted average: 14.38 +/- 0.05 Forced photometry reference-image weighted average: 13.82 +/- 0.03 Forced photometry reference-image weighted average: 14.61 +/- 0.06 Forced photometry reference-image weighted average: 15.06 +/- 0.09 Forced photometry filter REJECTED candidate at 17:29:33.01 +58:05:13.9: ref_mag=14.88 +/- 0.09 new_mean_mag=14.8896 delta=-0.01 (need > 0.90) Forced photometry filter REJECTED candidate at 17:13:12.45 +60:22:19.4: ref_mag=14.93 +/- 0.08 new_mean_mag=14.9021 delta=0.03 (need > 0.90) Forced photometry filter REJECTED candidate at 16:35:09.84 +61:18:18.1: ref_mag=14.73 +/- 0.07 new_mean_mag=14.8940 delta=-0.17 (need > 0.90) Forced photometry filter REJECTED candidate at 16:41:49.99 +60:05:12.3: ref_mag=14.61 +/- 0.06 new_mean_mag=14.8618 delta=-0.25 (need > 0.90) Forced photometry filter REJECTED candidate at 17:19:52.02 +62:56:50.7: ref_mag=14.38 +/- 0.05 new_mean_mag=14.7771 delta=-0.40 (need > 0.90) Forced photometry filter REJECTED candidate at 17:30:40.20 +58:31:58.1: ref_mag=13.82 +/- 0.03 new_mean_mag=14.4820 delta=-0.66 (need > 0.90) Forced photometry reference-image weighted average: 14.44 +/- 0.05 Forced photometry filter REJECTED candidate at 17:42:12.07 +62:53:56.7: ref_mag=15.06 +/- 0.09 new_mean_mag=14.9265 delta=0.13 (need > 0.90) Forced photometry filter REJECTED candidate at 17:41:22.31 +59:34:52.7: ref_mag=14.44 +/- 0.05 new_mean_mag=14.5275 delta=-0.09 (need > 0.90) Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 16:34:16.24 +65:09:52.2: 14.62 +/- 0.10 detection Forced photometry reference-image weighted average: 14.53 +/- 0.06 Forced photometry filter REJECTED candidate at 16:34:16.24 +65:09:52.2: ref_mag=14.53 +/- 0.06 new_mean_mag=14.6538 delta=-0.12 (need > 0.90) Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 16:46:43.00 +57:43:05.7: 14.21 +/- 0.06 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 17:09:47.99 +65:15:46.9: 13.36 +/- 0.03 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 17:04:42.57 +60:18:37.6: 14.07 +/- 0.05 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 16:47:43.07 +61:57:30.8: 13.53 +/- 0.03 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 17:41:56.42 +59:06:30.6: 13.44 +/- 0.03 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 17:47:46.14 +64:34:16.5: 13.11 +/- 0.02 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 16:56:05.18 +60:34:47.7: 13.54 +/- 0.03 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 17:41:42.70 +63:02:11.4: 13.28 +/- 0.02 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 16:46:43.00 +57:43:05.7: 14.42 +/- 0.07 detection Forced photometry reference-image weighted average: 14.30 +/- 0.05 Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 17:28:02.91 +64:14:16.3: 12.64 +/- 0.01 detection Forced photometry filter REJECTED candidate at 16:46:43.00 +57:43:05.7: ref_mag=14.30 +/- 0.05 new_mean_mag=14.5228 delta=-0.22 (need > 0.90) Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 17:04:42.57 +60:18:37.6: 14.05 +/- 0.05 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 17:09:47.99 +65:15:46.9: 13.44 +/- 0.03 detection Forced photometry reference-image weighted average: 14.06 +/- 0.03 Forced photometry filter REJECTED candidate at 17:04:42.57 +60:18:37.6: ref_mag=14.06 +/- 0.03 new_mean_mag=14.4050 delta=-0.34 (need > 0.90) Forced photometry reference-image weighted average: 13.40 +/- 0.02 Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 17:47:46.14 +64:34:16.5: 13.22 +/- 0.03 detection Forced photometry filter REJECTED candidate at 17:09:47.99 +65:15:46.9: ref_mag=13.40 +/- 0.02 new_mean_mag=13.7267 delta=-0.33 (need > 0.90) Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 16:47:43.07 +61:57:30.8: 13.62 +/- 0.03 detection Forced photometry reference-image weighted average: 13.16 +/- 0.02 Forced photometry filter REJECTED candidate at 17:47:46.14 +64:34:16.5: ref_mag=13.16 +/- 0.02 new_mean_mag=13.3953 delta=-0.24 (need > 0.90) Forced photometry reference-image weighted average: 13.57 +/- 0.02 Forced photometry filter REJECTED candidate at 16:47:43.07 +61:57:30.8: ref_mag=13.57 +/- 0.02 new_mean_mag=13.8246 delta=-0.25 (need > 0.90) Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 16:56:05.18 +60:34:47.7: 13.55 +/- 0.03 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 17:41:56.42 +59:06:30.6: 13.39 +/- 0.03 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 17:41:42.70 +63:02:11.4: 13.27 +/- 0.02 detection Forced photometry reference-image weighted average: 13.54 +/- 0.02 Forced photometry reference-image weighted average: 13.42 +/- 0.02 Forced photometry filter REJECTED candidate at 16:56:05.18 +60:34:47.7: ref_mag=13.54 +/- 0.02 new_mean_mag=13.6961 delta=-0.15 (need > 0.90) Forced photometry filter REJECTED candidate at 17:41:56.42 +59:06:30.6: ref_mag=13.42 +/- 0.02 new_mean_mag=13.5210 delta=-0.10 (need > 0.90) Forced photometry reference-image weighted average: 13.28 +/- 0.02 Forced photometry filter REJECTED candidate at 17:41:42.70 +63:02:11.4: ref_mag=13.28 +/- 0.02 new_mean_mag=13.5250 delta=-0.25 (need > 0.90) Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 17:28:02.91 +64:14:16.3: 12.62 +/- 0.01 detection Forced photometry reference-image weighted average: 12.63 +/- 0.01 Forced photometry filter REJECTED candidate at 17:28:02.91 +64:14:16.3: ref_mag=12.63 +/- 0.01 new_mean_mag=12.7698 delta=-0.14 (need > 0.90) Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 17:20:01.59 +63:15:60.0: 10.87 +/- 0.00 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 16:36:00.73 +63:54:53.4: 13.88 +/- 0.05 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 16:32:43.97 +64:42:47.8: 13.99 +/- 0.05 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 17:22:14.61 +64:25:26.7: 14.28 +/- 0.06 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 16:49:28.06 +58:53:56.7: 14.86 +/- 0.12 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 17:20:01.59 +63:15:60.0: 10.88 +/- 0.00 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 17:44:52.23 +65:24:34.7: 14.71 +/- 0.10 detection Forced photometry reference-image weighted average: 10.88 +/- 0.00 Forced photometry filter REJECTED candidate at 17:20:01.59 +63:15:60.0: ref_mag=10.88 +/- 0.00 new_mean_mag=10.9723 delta=-0.10 (need > 0.90) Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 16:36:00.73 +63:54:53.4: 13.98 +/- 0.05 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 16:32:43.97 +64:42:47.8: 13.98 +/- 0.06 detection Forced photometry reference-image weighted average: 13.93 +/- 0.04 Forced photometry filter REJECTED candidate at 16:36:00.73 +63:54:53.4: ref_mag=13.93 +/- 0.04 new_mean_mag=14.0479 delta=-0.12 (need > 0.90) Forced photometry reference-image weighted average: 13.99 +/- 0.04 Forced photometry filter REJECTED candidate at 16:32:43.97 +64:42:47.8: ref_mag=13.99 +/- 0.04 new_mean_mag=14.1217 delta=-0.14 (need > 0.90) Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 16:54:17.49 +63:48:43.5: 14.86 +/- 0.12 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 17:49:37.61 +64:02:56.2: 14.04 +/- 0.06 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 17:06:36.07 +65:41:11.7: 14.63 +/- 0.09 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 17:47:07.99 +63:16:25.4: 15.03 +/- 0.15 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 17:22:14.61 +64:25:26.7: 14.33 +/- 0.07 detection Forced photometry reference-image weighted average: 14.30 +/- 0.05 Forced photometry filter REJECTED candidate at 17:22:14.61 +64:25:26.7: ref_mag=14.30 +/- 0.05 new_mean_mag=14.4276 delta=-0.12 (need > 0.90) Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 16:49:28.06 +58:53:56.7: 14.83 +/- 0.11 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 17:44:52.23 +65:24:34.7: 14.61 +/- 0.09 detection Forced photometry reference-image weighted average: 14.84 +/- 0.08 Forced photometry filter REJECTED candidate at 16:49:28.06 +58:53:56.7: ref_mag=14.84 +/- 0.08 new_mean_mag=14.5740 delta=0.27 (need > 0.90) Forced photometry reference-image weighted average: 14.65 +/- 0.07 Forced photometry filter REJECTED candidate at 17:44:52.23 +65:24:34.7: ref_mag=14.65 +/- 0.07 new_mean_mag=14.6748 delta=-0.03 (need > 0.90) Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 16:54:17.49 +63:48:43.5: 15.05 +/- 0.13 detection Forced photometry reference-image weighted average: 14.94 +/- 0.09 Forced photometry filter REJECTED candidate at 16:54:17.49 +63:48:43.5: ref_mag=14.94 +/- 0.09 new_mean_mag=14.7657 delta=0.18 (need > 0.90) Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 17:49:37.61 +64:02:56.2: 14.20 +/- 0.07 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 17:06:36.07 +65:41:11.7: 14.68 +/- 0.10 detection Forced photometry reference-image weighted average: 14.11 +/- 0.04 Forced photometry reference-image weighted average: 14.66 +/- 0.07 Forced photometry filter REJECTED candidate at 17:49:37.61 +64:02:56.2: ref_mag=14.11 +/- 0.04 new_mean_mag=14.4335 delta=-0.32 (need > 0.90) Forced photometry filter REJECTED candidate at 17:06:36.07 +65:41:11.7: ref_mag=14.66 +/- 0.07 new_mean_mag=14.7963 delta=-0.14 (need > 0.90) Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 17:47:07.99 +63:16:25.4: 15.23 +/- 0.18 detection Forced photometry reference-image weighted average: 15.11 +/- 0.12 Forced photometry filter REJECTED candidate at 17:47:07.99 +63:16:25.4: ref_mag=15.11 +/- 0.12 new_mean_mag=14.7500 delta=0.36 (need > 0.90) Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 16:33:54.47 +59:46:06.6: 14.80 +/- 0.11 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 16:38:04.89 +59:02:45.7: 15.07 +/- 0.13 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 16:41:44.88 +57:50:55.3: 15.10 +/- 0.15 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 16:33:54.47 +59:46:06.6: 14.96 +/- 0.13 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 17:42:54.94 +64:06:08.1: 14.97 +/- 0.12 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 17:21:28.96 +64:34:08.5: 15.06 +/- 0.15 detection Forced photometry reference-image weighted average: 14.87 +/- 0.08 Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-55-54_20.00sec_-5.00C_LIGHT_0302.fits at 17:41:27.36 +61:26:35.5: 15.22 +/- 0.15 detection Forced photometry filter REJECTED candidate at 16:33:54.47 +59:46:06.6: ref_mag=14.87 +/- 0.08 new_mean_mag=14.8983 delta=-0.03 (need > 0.90) Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 16:41:44.88 +57:50:55.3: 15.37 +/- 0.19 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 16:38:04.89 +59:02:45.7: 14.99 +/- 0.13 detection Forced photometry reference-image weighted average: 15.20 +/- 0.12 Forced photometry reference-image weighted average: 15.03 +/- 0.09 Forced photometry filter REJECTED candidate at 16:41:44.88 +57:50:55.3: ref_mag=15.20 +/- 0.12 new_mean_mag=14.9710 delta=0.23 (need > 0.90) Forced photometry filter REJECTED candidate at 16:38:04.89 +59:02:45.7: ref_mag=15.03 +/- 0.09 new_mean_mag=14.8492 delta=0.18 (need > 0.90) Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 17:41:27.36 +61:26:35.5: 15.23 +/- 0.14 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 17:21:28.96 +64:34:08.5: 14.97 +/- 0.14 detection Forced photometry on wcs_Dra-07-Q2b1x1_2026-05-12_02-56-33_20.00sec_-4.90C_LIGHT_0303.fits at 17:42:54.94 +64:06:08.1: 14.89 +/- 0.11 detection Forced photometry reference-image weighted average: 15.22 +/- 0.10 Forced photometry reference-image weighted average: 15.01 +/- 0.10 Forced photometry reference-image weighted average: 14.93 +/- 0.08 Forced photometry filter REJECTED candidate at 17:41:27.36 +61:26:35.5: ref_mag=15.22 +/- 0.10 new_mean_mag=14.7281 delta=0.50 (need > 0.90) Forced photometry filter REJECTED candidate at 17:21:28.96 +64:34:08.5: ref_mag=15.01 +/- 0.10 new_mean_mag=14.9589 delta=0.05 (need > 0.90) Forced photometry filter REJECTED candidate at 17:42:54.94 +64:06:08.1: ref_mag=14.93 +/- 0.08 new_mean_mag=14.8565 delta=0.07 (need > 0.90) make_report_in_HTML.sh Phase 1 (network queries): 4s Pre-generating preview images in parallel... Done pre-generating preview images. Pre-generating finding charts in parallel... Done pre-generating finding charts. make_report_in_HTML.sh Pre-generation: 0s xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 77624_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 77624_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 1   2026 06 11.34493    2461202.84493    14.96    17:29:33.04 +58:05:15.3   3067 5459   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Discovery image 2   2026 06 11.34551    2461202.84551    14.84    17:29:32.98 +58:05:12.5   3063 5463   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 77633_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 77633_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 1   2026 06 11.34493    2461202.84493    14.95    17:42:12.41 +62:53:56.8   2493 2449   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Discovery image 2   2026 06 11.34551    2461202.84551    14.90    17:42:11.73 +62:53:56.6   2490 2452   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 77637_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 77637_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 1   2026 06 11.34493    2461202.84493    14.87    17:13:12.39 +60:22:19.7   4426 4163   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Discovery image 2   2026 06 11.34551    2461202.84551    14.94    17:13:12.51 +60:22:19.0   4422 4166   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 77640_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 77640_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 1   2026 06 11.34493    2461202.84493    14.89    16:35:09.93 +61:18:18.1   7207 3503   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Discovery image 2   2026 06 11.34551    2461202.84551    14.90    16:35:09.75 +61:18:18.2   7204 3506   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 77641_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 77641_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 1   2026 06 11.34493    2461202.84493    14.87    16:41:49.92 +60:05:12.9   6785 4284   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Discovery image 2   2026 06 11.34551    2461202.84551    14.85    16:41:50.06 +60:05:11.7   6781 4288   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 77645_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 77645_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 2   2026 06 11.34551    2461202.84551    14.88    16:57:06.56 +65:45:42.2   5547 0914   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits **** FOUND 16:57:06.68 +65:45:43.5 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 77646_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 77646_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 1   2026 06 11.34493    2461202.84493    14.69    17:19:51.92 +62:56:51.3   4028 2585   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Discovery image 2   2026 06 11.34551    2461202.84551    14.92    17:19:52.13 +62:56:50.1   4024 2588   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 77647_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 77647_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 1   2026 06 11.34493    2461202.84493    14.73    16:48:05.61 +63:49:05.7   6179 2063   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Discovery image 2   2026 06 11.34551    2461202.84551    14.79    16:48:05.70 +63:49:05.7   6176 2067   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 77652_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 77652_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 1   2026 06 11.34493    2461202.84493    14.50    17:41:22.45 +59:34:52.4   2256 4447   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Discovery image 2   2026 06 11.34551    2461202.84551    14.56    17:41:22.16 +59:34:52.9   2253 4450   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 77653_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 77653_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 1   2026 06 11.34493    2461202.84493    14.48    17:30:40.20 +58:31:58.0   3006 5181   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Discovery image 2   2026 06 11.34551    2461202.84551    14.48    17:30:40.20 +58:31:58.2   3002 5184   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 77655_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 77655_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 1   2026 06 11.34493    2461202.84493    14.65    16:34:16.17 +65:09:52.2   7011 1169   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Discovery image 2   2026 06 11.34551    2461202.84551    14.65    16:34:16.32 +65:09:52.1   7008 1173   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 77656_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 77656_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 1   2026 06 11.34493    2461202.84493    14.48    16:46:42.96 +57:43:05.6   6510 5747   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Discovery image 2   2026 06 11.34551    2461202.84551    14.58    16:46:43.05 +57:43:05.8   6506 5750   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 77658_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 77658_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 1   2026 06 11.34493    2461202.84493    14.42    17:04:42.62 +60:18:37.5   5060 4214   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Discovery image 2   2026 06 11.34551    2461202.84551    14.39    17:04:42.52 +60:18:37.8   5057 4217   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 77661_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 77661_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 2   2026 06 11.34551    2461202.84551    14.37    16:57:49.37 +58:03:18.6   5602 5580   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits **** FOUND 16:57:49.50 +58:03:18.8 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 77665_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 77665_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 1   2026 06 11.34493    2461202.84493    13.81    16:56:05.23 +60:34:47.6   5701 4044   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Discovery image 2   2026 06 11.34551    2461202.84551    13.62    16:56:05.12 +60:34:47.8   5698 4047   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 77666_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 77666_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 1   2026 06 11.34493    2461202.84493    13.78    16:47:43.10 +61:57:31.0   6272 3185   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Discovery image 2   2026 06 11.34551    2461202.84551    13.88    16:47:43.04 +61:57:30.7   6269 3188   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 77668_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 77668_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 1   2026 06 11.34493    2461202.84493    13.68    17:09:47.93 +65:15:46.3   4753 1214   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Discovery image 2   2026 06 11.34551    2461202.84551    13.78    17:09:48.04 +65:15:47.4   4750 1217   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 77669_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 77669_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 1   2026 06 11.34493    2461202.84493    13.54    17:41:42.69 +63:02:11.2   2539 2371   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Discovery image 2   2026 06 11.34551    2461202.84551    13.51    17:41:42.70 +63:02:11.6   2536 2374   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 77670_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 77670_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 1   2026 06 11.34493    2461202.84493    13.51    17:41:56.44 +59:06:30.9   2170 4725   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Discovery image 2   2026 06 11.34551    2461202.84551    13.54    17:41:56.40 +59:06:30.2   2166 4728   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 77671_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 77671_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 1   2026 06 11.34493    2461202.84493    13.44    17:47:46.15 +64:34:16.2   2284 1386   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Discovery image 2   2026 06 11.34551    2461202.84551    13.36    17:47:46.13 +64:34:16.8   2281 1389   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 77674_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 77674_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 2   2026 06 11.34551    2461202.84551    12.88    17:17:53.85 +63:04:47.2   4164 2516   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits **** FOUND 17:17:53.84 +63:04:47.2 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 77676_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 77676_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 1   2026 06 11.34493    2461202.84493    12.75    17:28:02.99 +64:14:16.1   3541 1762   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Discovery image 2   2026 06 11.34551    2461202.84551    12.80    17:28:02.84 +64:14:16.6   3537 1765   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 77677_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 77677_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 2   2026 06 11.34551    2461202.84551    12.78    16:37:31.02 +62:14:22.0   6976 2961   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits **** FOUND 16:37:31.07 +62:14:22.3 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 77678_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 77678_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 2   2026 06 11.34551    2461202.84551    12.11    16:49:00.69 +57:56:44.6   6312 5622   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits **** FOUND 16:49:00.69 +57:56:44.6 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 77679_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 77679_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 2   2026 06 11.34551    2461202.84551    11.49    17:20:28.19 +57:53:05.7   3781 5644   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits **** FOUND 17:20:28.21 +57:53:05.8 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 78356_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 78356_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 1   2026 06 11.34493    2461202.84493    10.97    17:20:01.66 +63:16:00.0   4029 2391   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Discovery image 2   2026 06 11.34551    2461202.84551    10.98    17:20:01.52 +63:15:59.9   4026 2394   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 79729_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 79729_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 2   2026 06 11.34551    2461202.84551    12.24    16:54:14.78 +62:14:40.6   5799 3037   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits **** FOUND 16:54:14.76 +62:14:40.5 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 80469_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 80469_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 2   2026 06 11.34551    2461202.84551    12.78    17:06:32.13 +64:08:31.4   4948 1900   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits **** FOUND 17:06:32.09 +64:08:31.8 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 80534_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 80534_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 2   2026 06 11.34551    2461202.84551    12.86    16:32:53.18 +62:50:42.3   7260 2561   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits **** FOUND 16:32:53.18 +62:50:42.4 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 84324_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 84324_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 1   2026 06 11.34493    2461202.84493    14.05    16:36:00.73 +63:54:53.4   6979 1937   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Discovery image 2   2026 06 11.34551    2461202.84551    14.05    16:36:00.73 +63:54:53.3   6976 1940   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 84708_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 84708_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 1   2026 06 11.34493    2461202.84493    14.12    16:32:43.93 +64:42:47.9   7141 1430   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Discovery image 2   2026 06 11.34551    2461202.84551    14.12    16:32:44.01 +64:42:47.7   7137 1434   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 84791_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 84791_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 2   2026 06 11.34551    2461202.84551    13.99    17:20:21.03 +62:27:02.8   3972 2885   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits **** FOUND 17:20:21.02 +62:27:03.0 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 85385_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 85385_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 2   2026 06 11.34551    2461202.84551    14.12    17:48:15.82 +64:46:24.7   2270 1262   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits **** FOUND 17:48:15.83 +64:46:24.2 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 86218_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 86218_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 2   2026 06 11.34551    2461202.84551    14.34    16:58:34.15 +62:30:17.3   5492 2888   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits **** FOUND 16:58:34.12 +62:30:16.9 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 86686_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 86686_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 2   2026 06 11.34551    2461202.84551    14.35    17:44:05.50 +63:31:19.5   2420 2058   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits **** FOUND 17:44:05.39 +63:31:19.8 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 86722_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 86722_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 1   2026 06 11.34493    2461202.84493    14.41    17:22:14.60 +64:25:27.2   3929 1682   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Discovery image 2   2026 06 11.34551    2461202.84551    14.45    17:22:14.62 +64:25:26.1   3926 1685   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 86903_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 86903_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 2   2026 06 11.34551    2461202.84551    14.50    17:01:31.72 +63:56:02.9   5279 2027   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits **** FOUND 17:01:31.74 +63:56:04.4 in the exclusion list exclusion_list.txt **** xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 88016_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 88016_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 1   2026 06 11.34493    2461202.84493    14.56    16:49:28.02 +58:53:57.0   6248 5041   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Discovery image 2   2026 06 11.34551    2461202.84551    14.58    16:49:28.10 +58:53:56.4   6244 5045   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 88318_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 88318_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 1   2026 06 11.34493    2461202.84493    14.63    17:44:52.40 +65:24:36.8   2552 0914   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Discovery image 2   2026 06 11.34551    2461202.84551    14.73    17:44:52.07 +65:24:32.5   2549 0918   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 88677_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 88677_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 1   2026 06 11.34493    2461202.84493    14.75    16:54:17.47 +63:48:42.8   5766 2087   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Discovery image 2   2026 06 11.34551    2461202.84551    14.78    16:54:17.50 +63:48:44.3   5763 2090   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 88844_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 88844_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 1   2026 06 11.34493    2461202.84493    14.68    17:49:37.67 +64:02:56.2   2109 1677   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Discovery image 2   2026 06 11.34551    2461202.84551    14.32    17:49:37.56 +64:02:56.3   2105 1679   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 88949_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 88949_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 1   2026 06 11.34493    2461202.84493    14.80    17:06:36.04 +65:41:12.6   4959 0960   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Discovery image 2   2026 06 11.34551    2461202.84551    14.80    17:06:36.09 +65:41:10.8   4956 0964   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 89416_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 89416_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 1   2026 06 11.34493    2461202.84493    14.75    17:47:08.13 +63:16:25.9   2194 2170   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Discovery image 2   2026 06 11.34551    2461202.84551    14.75    17:47:07.84 +63:16:25.0   2191 2173   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 90085_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 90085_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 1   2026 06 11.34493    2461202.84493    14.93    16:33:54.45 +59:46:06.1   7405 4419   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Discovery image 2   2026 06 11.34551    2461202.84551    14.87    16:33:54.48 +59:46:07.2   7401 4423   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 90377_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 90377_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 1   2026 06 11.34493    2461202.84493    14.95    16:38:04.82 +59:02:46.6   7130 4888   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Discovery image 2   2026 06 11.34551    2461202.84551    14.78    16:38:04.95 +59:02:44.7   7126 4892   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 90541_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 90541_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 1   2026 06 11.34493    2461202.84493    14.97    16:41:45.02 +57:50:55.3   6906 5640   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Discovery image 2   2026 06 11.34551    2461202.84551    14.97    16:41:44.74 +57:50:55.3   6902 5643   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 90560_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 90560_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 1   2026 06 11.34493    2461202.84493    14.97    17:21:28.90 +64:34:08.2   3985 1598   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Discovery image 2   2026 06 11.34551    2461202.84551    14.95    17:21:29.03 +64:34:08.9   3982 1601   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 90904_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 90904_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 1   2026 06 11.34493    2461202.84493    14.89    17:41:27.45 +61:26:35.2   2415 3329   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Discovery image 2   2026 06 11.34551    2461202.84551    14.67    17:41:27.26 +61:26:35.7   2412 3332   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Considering the candidate 91171_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 The candidate 91171_fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245 did not pass the final checks Discovery image 1   2026 06 11.34493    2461202.84493    15.03    17:42:55.07 +64:06:08.2   2555 1720   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-16-32_20.00sec_4.90C_LIGHT_0244.fits Discovery image 2   2026 06 11.34551    2461202.84551    14.75    17:42:54.80 +64:06:07.9   2552 1723   /data_ssd/NMW-TexasTech/workdir//img_2026-06-11_CI_Dra-07-Q2b1x1_034346_TTUQ2b1x1_660418_EGPVAqmt/fd_Dra-07-Q2b1x1_2026-06-11_03-17-21_20.00sec_5.00C_LIGHT_0245.fits make_report_in_HTML.sh Phase 2 (HTML assembly): 0s make_report_in_HTML.sh TOTAL: 4s Prepared the HTML report for the field Dra-07-Q2b1x1 with default.sex.telephoto_lens_vSTL *------ done with default.sex.telephoto_lens_vSTL ------* #### The local exclusion list is exclusion_list_local.txt #### ########### Completed Dra-07-Q2b1x1 ########### The analysis was running at tau We are allowed to update the exclusion list at tau host Found ../exclusion_list_TTUQ2.txt #### The exclusion list before filtering-out asteroids, bad pixels and adding Gaia sources #### ################################################################################### renamed 'exclusion_list_index_html.txt_noasteroids' -> 'exclusion_list_index_html.txt' renamed 'exclusion_list_index_html.txt_nohotpixels' -> 'exclusion_list_index_html.txt' # Count candidates with no identification (that also don't look like hot pix) Found 0 unidentified candidates (excluding asteroids, hot pixels and known variable stars). ################################################################################### 0 candidates found (excluding asteroids and hot pixels) This does not look like a test run ################################################################################### exclusion_list_gaiadr2.txt NOT FOUND exclusion_list_apass.txt NOT FOUND IS_THIS_TEST_RUN=NO ALLOW_EXCLUSION_LIST_UPDATE= YES #### Nothing to add to the exclusion list #### The observatory MPC code is V36 ############################################################ Positions of planets computed with util/planet_finder/main.py for JD(UT)2461202.84493163 -observatory V36 07:01:27.24 +24:19:58.7 Mercury (0.3mag) 07:58:37.24 +22:42:50.8 Venus (-4.0mag) 02:58:47.14 +16:24:43.1 Mars (1.3mag) 07:51:04.84 +21:24:43.9 Jupiter (-1.9mag) 00:50:14.98 +02:53:25.0 Saturn (0.8mag) 04:00:57.21 +20:27:36.1 Uranus (5.8mag) 00:16:19.10 +00:17:46.3 Neptune (7.8mag) 20:33:10.50 -23:05:44.9 Pluto (14.5mag) 01:37:54.55 +13:43:03.3 Moon (-9.4mag) -rw-r--r-- 1 apache apache 361 Jun 11 04:33 planets.txt ############################################################ Positions of selected moons from JPL HORIZONS for JD(UT)2461202.84493163: 07:50:59.40 +21:25:01.2 Io (6.0mag) 07:50:58.48 +21:25:05.3 Europa (6.2mag) 07:51:21.12 +21:23:56.8 Ganymede (5.6mag) 07:50:49.99 +21:25:23.3 Callisto (6.7mag) 07:51:10.84 +21:01:17.9 Himalia (15.6mag) 07:51:04.16 +21:24:47.4 Thebe (16.5mag) 07:51:05.03 +21:15:22.0 Elara (17.5mag) 07:53:25.18 +21:34:42.5 Pasiphae (17.7mag) 07:57:31.52 +21:26:41.0 Carme (18.9mag) 00:50:17.61 +02:53:01.2 Titan (8.6mag) 00:50:19.77 +02:53:29.1 Rhea (9.9mag) 00:50:44.75 +02:55:49.8 Iapetus (11.3mag) 00:50:22.59 +02:52:54.9 Hyperion (14.6mag) 00:50:53.34 +02:54:54.2 Phoebe (16.7mag) -rw-r--r-- 1 apache apache 568 Jun 11 04:33 moons.txt ############################################################ Positions of selected spacecraft from JPL HORIZONS for JD(UT)2461202.84493163: 17:26:51.35 -35:29:52.1 JWST 16:38:20.06 +47:09:01.9 Chandra 09:20:50.72 -53:15:24.9 XMM-Newton -rw-r--r-- 1 apache apache 96 Jun 11 04:33 spacecraft.txt ############################################################ Positions of bright comets computed with util/comet_finder/main.py for JD(UT)2461202.84493163 -observatory V36 18:41:16.95 -32:52:47.8 13.6mag P/2010 H2 (Vales) 05:56:34.96 -68:02:04.8 17.4mag C/2014 UN271 (Bernardinelli-Bernstein) 05:50:13.35 +32:00:34.5 17.5mag C/2017 K2 (PANSTARRS) 17:13:28.12 +15:30:04.6 17.8mag C/2021 G2 (ATLAS) 21:42:10.73 -47:31:25.3 16.6mag P/2021 N1 (ZTF) 23:11:53.16 +31:42:32.2 17.2mag C/2022 E2 (ATLAS) 05:37:54.15 +26:59:30.3 16.5mag C/2022 N2 (PANSTARRS) 09:32:01.26 +30:58:14.2 16.7mag C/2022 QE78 (ATLAS) 08:52:15.33 +04:04:42.7 17.7mag C/2022 R6 (PANSTARRS) 18:26:09.38 +21:39:15.6 17.8mag C/2023 A3 (Tsuchinshan-ATLAS) 15:18:16.10 -11:00:57.8 17.6mag P/2023 B1 (PANSTARRS) 22:13:15.80 +66:43:00.5 17.8mag C/2023 H5 (Lemmon) 17:38:34.23 -07:00:04.5 13.7mag C/2023 R1 (PANSTARRS) 13:16:54.89 +82:16:12.6 18.0mag C/2023 X2 (Lemmon) 07:14:50.59 +64:25:03.3 17.7mag C/2024 A1 (ATLAS) 06:52:01.72 +28:06:31.8 13.7mag C/2024 E1 (Wierzchos) 15:34:50.74 +13:47:34.2 17.4mag C/2024 G6 (ATLAS) 20:10:51.75 +32:04:00.7 14.0mag C/2024 J3 (ATLAS) 04:21:11.18 -15:40:49.3 16.0mag C/2024 T5 (ATLAS) 06:08:50.81 +33:56:44.5 17.9mag C/2025 J1 (Borisov) 11:33:35.80 +52:33:51.4 17.5mag C/2025 L1 (ATLAS) 06:48:40.03 -11:00:53.4 14.4mag C/2025 R3 (PANSTARRS) 09:26:47.58 +23:17:38.8 17.9mag C/2025 V2 (Rankin) 12:39:40.48 +04:40:28.3 17.2mag C/2025 Y1 (ATLAS) 18:07:33.71 +75:47:35.4 17.8mag C/2026 A2 (Bok) 02:06:03.88 +43:38:08.4 16.1mag C/2026 B2 (Sun-Gao) 11:12:02.19 -02:39:14.4 16.5mag A/2026 E1 20:29:21.30 -08:49:27.5 8.6mag 10P/Tempel 11:02:46.85 -01:01:01.3 16.0mag 29P/Schwassmann-Wachmann 03:16:35.65 +26:03:50.9 17.7mag 47P/Ashbrook-Jackson 09:06:42.13 +22:51:48.5 16.9mag 63P/Wild 00:29:35.28 -06:10:16.3 15.7mag 65P/Gunn 06:53:40.25 +33:43:26.7 17.0mag 76P/West-Kohoutek-Ikemura 03:16:48.58 +17:36:34.8 13.8mag 78P/Gehrels 01:27:32.26 +05:31:27.1 15.6mag 88P/Howell 05:04:47.30 +30:31:11.0 15.3mag 93P/Lovas 02:51:56.02 +28:07:09.7 17.5mag 114P/Wiseman-Skiff 06:58:05.02 +32:54:49.2 15.6mag 123P/West-Hartley 09:55:40.70 +13:17:25.4 16.5mag 124P/Mrkos 04:04:14.30 +19:27:22.1 16.3mag 128P/Shoemaker-Holt 04:39:49.69 +19:13:17.2 17.7mag 131P/Mueller 06:11:38.72 +18:16:44.9 15.0mag 141P/Machholz 06:14:27.47 +17:48:38.4 15.0mag 141P-A/Machholz 05:09:49.49 +16:34:12.2 11.9mag 141P-D/Machholz 02:59:53.00 -24:16:11.8 16.7mag 161P/Hartley-IRAS 03:51:57.91 +25:03:04.8 15.0mag 162P/SidingSpring 19:36:12.45 +02:40:50.8 16.7mag 169P/NEAT 00:26:48.21 +03:04:30.6 17.8mag 220P/McNaught 16:49:48.53 -08:20:07.8 16.4mag 235P/LINEAR 07:41:46.30 +35:21:07.5 17.6mag 240P/NEAT 00:40:38.37 -01:07:12.9 16.3mag 260P/McNaught 04:12:50.60 +33:02:32.3 17.5mag 295P/LINEAR 00:11:22.10 -05:50:04.4 17.7mag 320P/McNaught 15:13:51.74 +07:58:56.7 17.4mag 391P/Kowalski 08:09:39.98 +20:39:49.8 17.9mag 450P/LONEOS 07:05:06.78 +41:28:14.8 17.8mag 493P/LONEOS -rw-r--r-- 1 apache apache 2.7K Jun 11 04:33 comets.txt ############################################################ List of recent ASAS-SN transients from https://www.astronomy.ohio-state.edu/asassn/transients.html : 20:07:38.15 -21:07:05.40 SN2026mho 2026-05-25.18 -1.12 11:29:42.55 +79:01:03.10 AT2026min 2026-05-24.21 16.63 11:44:32.95 -68:48:30.00 ASASSN-26no 2026-05-24 8.41 19:00:42.82 -48:31:01.60 ASASSN-26dp 2026-05-22.31 -3.28 14:23:56.59 -58:37:47.40 ASASSN-26dn 2026-05-20.01 14.59 11:24:54.06 +47:57:01.60 AT2026nma 2026-05-20.29 15.46 21:27:08.58 +33:24:38.10 AT2026lli 2026-05-19.34 15.86 00:31:01.41 -13:38:51.70 AT2026nad 2026-05-19.39 15.34 15:16:06.61 -79:16:32.40 ASASSN-26dm 2026-05-19.03 14.44 11:24:25.21 -59:23:19.10 ASASSN-26dl 2026-05-18.02 13.55 13:45:51.52 -53:16:01.00 ASASSN-26dk 2026-05-18.16 12.96 02:05:49.69 -30:29:09.60 ASASSN-26dh 2026-05-18.43 15.37 17:50:22.87 -39:42:33.90 ASASSN-26dj 2026-05-17.05 15.7 01:13:11.60 -33:25:16.10 ASASSN-26dg 2026-05-13.41 16.8 16:44:31.77 -27:15:18.40 AT2026mhn 2026-05-12.33 15.8 09:46:31.08 -33:41:51.00 ASASSN-26di 2026-05-12.14 14.63 21:23:11.57 -19:09:45.00 AT2026kwu 2026-05-12.26 16.9 14:20:14.30 -30:20:51.90 AT2026ktm 2026-05-12.06 17.21 14:41:39.01 -37:13:46.40 AT2026lkm 2026-05-11.18 16.89 12:59:50.45 -10:58:38.80 SN2026kep 2026-05-9.06 17.5 13:37:29.61 -29:50:30.90 AT2026lkd 2026-05-9.09 17.23 09:46:42.01 -14:52:03.60 SN2026kmo 2026-05-8.99 17.51 15:03:05.28 +22:02:03.40 AT2026lxf 2026-05-8.07 13.88 10:23:49.41 -20:57:25.30 ASASSN-26df 2026-05-8.21 16.52 22:14:40.56 +05:04:51.60 2026lda 2026-05-7.56 16.2 21:35:33.81 -14:05:16.30 ASASSN-26de 2026-05-6.29 14.51 16:21:48.82 -61:36:13.20 ASASSN-26dd 2026-05-5.21 15.15 14:26:40.22 -24:48:37.50 AT2026lig 2026-05-4.27 14.63 13:17:51.04 +30:25:13.50 SN2026kcp 2026-05-4.46 16.43 11:27:55.57 -13:38:56.90 SN2026kza 2026-05-1.08 15.59 22:28:27.10 +30:17:54.30 SN 2026fov 2026-04-29.6 14.36 21:00:10.71 -32:17:03.90 AT2026kis 2026-04-27.36 16.15 14:32:57.37 -58:13:26.40 ASASSN-26dc 2026-04-27.27 13.42 15:32:05.35 -43:54:34.60 ASASSN-26db 2026-04-27.37 16.06 16:34:34.97 -54:34:58.00 ASASSN-26da 2026-04-25.32 16.11 10:06:55.04 -01:13:49.70 SN2026jsg 2026-04-24.99 16.28 15:15:57.17 +56:18:32.80 SN2026kid 2026-04-24.52 -3.65 07:58:28.45 +57:03:42.40 AT2026kcf 2026-04-24.2 16.89 11:38:21.80 -50:43:06.50 SN2026jkb 2026-04-24.24 15.38 10:06:11.41 -39:41:04.20 AT2026dil 2026-04-24.2 16.85 14:21:40.08 +13:13:46.30 SN2026jlm 2026-04-22.16 15.12 10:53:55.52 -16:06:06.00 ASASSN-26cz 2026-04-22.28 16.29 20:07:38.15 -21:07:05.40 2026-05-25.18 -1.12 13:45:02.03 +15:17:14.50 ASASSN-26cy 2026-04-21.27 15.78 13:20:52.22 -35:57:03.60 AT2026jcm 2026-04-19.01 16.65 13:36:15.66 -36:53:48.40 SN 2026iqy 2026-04-18.92 17.31 06:34:01.33 -40:07:34.00 ASASSN-26cx 2026-04-19.07 16.16 23:33:57.97 -45:12:11.90 SN 2026idu 2026-04-19.41 15.9 12:10:50.92 +66:55:31.20 SN 2026icv 2026-04-17.14 16.03 21:36:59.06 -60:43:35.90 ASASSN-26cv 2026-04-17.35 -1.18 08:13:26.26 -27:07:30.50 ASASSN-26cw 2026-04-17.07 -1.01 14:49:14.13 -27:29:20.60 ASASSN-26cu 2026-04-16.06 14.03 17:21:59.44 -38:54:04.60 ASASSN-26ct 2026-04-14.4 15.15 15:25:54.99 +07:49:24.50 SN2026huo 2026-04-12.14 16.96 20:07:38.15 -21:07:05.40 2026-05-25.18 -1.12 12:23:20.40 +04:53:39.10 AT2026ixd 2026-04-12.14 17.65 17:46:09.76 -61:19:50.40 SN2026icy 2026-04-12.2 17.03 09:25:46.42 +02:13:46.30 SN2026gud 2026-04-11.98 16.49 16:52:15.46 -60:27:45.90 ASASSN-26cs 2026-04-12.4 15.5 04:20:55.37 -51:15:31.10 ASASSN-26cr 2026-04-12.01 15.37 22:25:39.35 +36:45:06.90 AT2026ihl 2026-04-10.48 14.21 19:40:44.94 +00:41:03.80 AT2026imw 2026-04-10.32 16.06 19:52:04.70 +05:53:33.50 ASASSN-26cq 2026-04-9.31 14.98 16:08:18.39 -64:11:08.80 ASASSN-26cp 2026-04-9.29 13.32 09:22:22.90 -61:02:43.70 SN2026idh 2026-04-7.97 16.34 05:06:54.12 -19:42:26.40 AT2026imr 2026-04-8 17.49 07:14:55.34 -36:03:21.40 AT2026hei 2026-04-8.12 16.7 21:35:33.14 -19:01:34.80 AT2026ihm 2026-04-8.36 16.7 04:28:24.08 -32:25:35.30 AT2026imo 2026-04-8.02 16.81 05:10:35.79 -39:38:40.80 SN 2026hnn 2026-04-7.04 17.07 09:54:32.04 -01:17:25.80 ASASSN-26cn 2026-04-7.01 15.58 07:46:24.43 -77:29:35.90 ASASSN-26co 2026-04-7.15 14.93 05:00:45.52 -29:51:06.20 AT2026hvw 2026-04-6.03 16.51 19:49:33.10 -23:37:11.00 ASASSN-26cl 2026-04-5.29 14.98 19:32:43.55 -22:39:33.40 ASASSN-26cm 2026-04-4.3 13.88 18:08:57.38 +76:48:23.60 ASASSN-26ck 2026-04-2.37 15.38 16:16:36.10 +44:52:30.20 AT2026hyy 2026-04-2.58 13.81 21:55:23.31 -34:48:53.90 ASASSN-26cj 2026-03-30.4 -1.47 11:19:50.70 -27:51:49.80 SN2026gvk 2026-03-30 15.48 11:53:57.02 -23:09:46.20 SN2026gzx 2026-03-28.75 15.27 07:13:46.14 -33:10:15.70 ASASSN-26ci 2026-03-28.15 15.14 09:03:36.09 -67:58:13.00 SN2026hkg 2026-03-28.19 15.82 07:03:00.72 +39:14:43.00 SN2026fin 2026-03-28.27 15.82 05:35:42.80 -63:44:05.50 ASASSN-26ch 2026-03-27.86 13.02 11:23:19.04 +34:22:38.00 SN2026fwt 2026-03-27.3 16.56 19:03:49.79 +37:04:05.20 ASASSN-26ce 2026-03-26.56 16.3 20:26:56.07 -52:54:06.50 AT2026hiy 2026-03-26.35 16.95 05:25:54.76 -30:15:35.80 ASASSN-26cg 2026-03-25.07 16.88 06:57:16.49 -26:54:37.20 SN2026fzb 2026-03-25.14 15.8 14:37:38.23 -43:00:52.30 ASASSN-26cd 2026-03-24.24 12.52 17:34:53.03 +06:04:29.70 AT2026gzl 2026-03-23.27 15.82 08:30:02.60 -35:12:47.50 ASASSN-26cf 2026-03-23.2 14.82 16:54:25.33 +37:49:56.60 SN 2026evz 2026-03-21.32 17.54 17:06:19.20 -18:54:19.50 ASASSN-26bx 2026-03-21.25 16.39 19:01:16.28 -29:29:23.10 ASASSN-26bw 2026-03-21.33 15.81 08:46:05.75 +10:47:39.80 ASASSN-26ca 2026-03-21.13 14.27 12:14:58.16 +63:47:16.20 SN 2026fvx 2026-03-21.12 15.6 18:02:55.90 -75:23:02.60 ASASSN-26bz 2026-03-21.32 16.16 12:16:02.88 -53:16:33.80 ASASSN-26cc 2026-03-20.04 15.48 13:08:21.85 +29:13:44.20 SN 2026fmh 2026-03-20.16 -0.33 -rw-r--r-- 1 apache apache 5.6K Jun 11 04:33 asassn_transients_list.txt ############################################################ Truncated list of TOCP transients from http://www.cbat.eps.harvard.edu/unconf/tocp.html : 09:55:38.83 +69:05:21.7 PNV J09553883+6905217 2026-04-01.893 19.4mag 19:32:43.67 -22:39:30.7 TCP J19324367-2239307 2026-04-05.4395 13.6mag 16:16:36.03 +44:52:28.9 TCP J16163603+4452289 2026-04-05.6655 14.2mag 00:43:38.36 +41:15:32.4 PNV J00433836+4115324 2026-04-08.079 17.2mag 15:41:11.68 +59:18:26.8 TCP J15411168+5918268 2026-04-12.9625 19.2mag 00:43:35.02 +41:46:28.0 PNV J00433502+4146280 2026-04-23.056 15.9mag 00:42:55.64 +41:14:12.2 PNV J00425564+4114122 2026-04-24.042 16.2mag 21:14:03.38 +56:46:44.1 TCP J21140338+5646441 2026-05-05.3534 16.7mag 15:03:05.19 +22:02:04.1 TCP J15030519+2202041 2026-05-08.3260 13.9mag 07:15:18.25 +47:53:16.7 TCP J07151825+4753167 2026-05-09.1599 14.4mag 16:00:18.44 -22:30:10.6 TCP J16001844-2230106 2026-05-09.6135 13.3mag 00:42:47.45 +41:16:58.5 PNV J00424745+4116585 2026-05-10.030 16.8mag 09:55:02.89 +69:02:13.8 PNV J09550289+6902138 2026-05-18.925 20.7mag 00:43:01.82 +41:18:16.6 PNV J00430182+4118166 2026-05-21.8651 18.83Cmag 00:42:51.20 +41:16:59.4 PNV J00425120+4116594 2022-10-26.135 19.3mag 12:24:25.10 +28:47:12.0 TCP J12242510+2847120 2026-05-31.6015 14.8mag 00:56:07.13 +43:01:40.6 TCP J00560713+4301406 2026-06-01.4135 12.2mag 00:42:41.64 +41:15:16.2 PNV J00424164+4115162 2026-06-02.029 17.4mag 00:42:38.68 +41:15:58.2 PNV J00423868+4115582 2026-06-05.1224 19.97Umag 19:00:42.95 -48:31:01.7 PNV J19004295-4831017 2026-05-25.0752 14.2mag -rw-r--r-- 1 apache apache 189K Jun 11 04:33 tocp_transients_list.txt ############################################################ Truncated list of recent TNS transients from https://www.wis-tns.org/ : 14:42:53.361 +09:25:56.12 AT 2026oek 2026-05-31.21 19.7393 16:12:09.163 +29:54:51.29 AT 2026oej 2026-05-25.37 21.1198 16:32:31.727 +65:39:51.90 AT 2026oei 2026-05-23.32 20.7631 16:04:39.925 -21:36:56.05 AT 2026oeh 2026-05-21.40 20.1751 15:27:47.338 +38:55:13.31 AT 2026oeg 2026-05-21.97 19.64 14:51:39.615 +45:21:56.05 AT 2026oef 2026-05-28.95 19.09 10:32:49.111 +46:46:00.48 AT 2026oee 2026-06-03.89 19.348 17:25:39.755 +21:57:18.90 SN 2026oed 2026-05-31.37 19.4457 09:59:38.199 +00:31:00.31 AT 2026oec 2026-05-30.97 22.39 09:27:53.984 +22:21:00.63 AT 2026oeb 2026-06-01.17 18.66 09:22:28.890 +11:30:25.73 AT 2026oea 2026-06-04.18 19.4125 12:42:23.918 -13:22:38.30 AT 2026odz 2026-06-02.21 20.0149 09:58:40.601 +01:27:22.46 AT 2026ody 2026-05-29.04 21.94 14:57:09.055 +33:12:55.31 AT 2026odx 2026-05-28.93 19.3 13:30:34.211 +08:18:17.60 AT 2026odw 2026-06-02.93 19.81 22:05:04.941 -08:18:56.22 SN 2026odv 2026-06-03.15 18.492 01:22:49.923 +43:28:14.10 AT 2026odu 2026-05-31.48 19.5762 09:01:08.906 -74:52:14.00 AT 2026odt 2026-06-03.00 17.911 12:00:27.833 -47:27:26.10 AT 2026ods 2026-06-03.09 18.497 01:23:02.862 -43:07:38.98 SN 2026odr 2026-05-31.37 17.272 -rw-r--r-- 1 apache apache 30K Jun 11 04:33 tns_transients_list.txt

Profiling:

CPU temperature: 90 C