This analysis is done by the script util/transients/transient_factory_test31.sh /data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH
The list of candidates will appear below. Please manually reload the page every few minutes untill the 'Processing complete' message appears.
Mean magnitude and position on the discovery images:
2026 05 20.1487 2461180.6487 11.16 09:16:47.32 +17:53:44.1
211.70925 39.93798 galactic Cnc Second-epoch detections are separated by 1.0" and 1.8 pix
The object was not found in VSX
The object was not found in ASASSN-V
The object was found in astcheck.44 Nysa -3 1 3 11.3 -0 0
Forced photometry on wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits at 09:16:47.32 +17:53:44.1: 15.95 +/- 99.00 upperlimit
Forced photometry on wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits at 09:16:47.32 +17:53:44.1: 16.03 +/- 99.00 upperlimit
Check this position in TNS.Manually check the ASAS-SN list of transients!Search this object in SIMBAD.Search this object in VizieR catalogs.WISE atlasAladin LiteSNAD ZTF viewer
Online MPChecker may fail to identify bright comets! Please manually check the Seiichi Yoshida's and Gideon van Buitenen's pages.
Don't forget to copy the leading white spaces and change the observatory code!
The code 'C32' is 'Ka-Dar Observatory, TAU Station, Nizhny Arkhyz', the code '500' is the geocenter.
Make sure there are no trailing white spaces after the observatory code.
The string should be exactly 80 characters long to conform to the MPC format.
Mean position:
You may copy/paste the above measurements to the following online services: MPChecker (in case the button does not work) NEOCMTChecker (NEO's and comets) sat_id2 (artificial satellites; needs at least two observations to work) fitsblink_satellites (art. sat.; you'll need to save the astrometry as a text file and upload it)
Here is a stub line for reporting a new transient to the TOCP.
Don't forget to set the constellation name and the number of days since the last non-detection!
Don't forget to change the observer code for the AAVSO and VSNET format data!
**** AAVSO file format ****
#TYPE=EXTENDED
#OBSCODE=SKA
#SOFTWARE=VaST 1.0rc90 transient pipeline
#DELIM=,
#DATE=JD
#NAME,DATE,MAG,MERR,FILT,TRANS,MTYPE,CNAME,CMAG,KNAME,KMAG,AMASS,GROUP,CHART,NOTES
VARIABLE_NAME,2461180.6487,11.16,0.05,CV,NO,STD,ENSEMBLE,na,na,na,na,1,na,NMW-TexasTech Camera-2 135mm f/2.2 telephoto lens + QHY600M CMOS
**** VSNET file format ****
# Here are some valid formatiing examples:
#CETFZ 20230815.9829 <13.5CV NMW
#CETFZ 20230818.9746 12.5CV NMW
#CETFZ 20230819.9732 12.6CV NMW
#TCPJ17453768-1756253 20230831.7290 12.7CV NMW
VARIABLE_NAME 20260520.1487 11.16CV NMW
The AAVSO data should be submitted to https://www.aavso.org/webobs
The VSNET data, depending on how interesting the target is, should be e-mailed to
vsnet-alert@ooruri.kusastro.kyoto-u.ac.jp
vsnet-outburst-wanted@ooruri.kusastro.kyoto-u.ac.jp
vsnet-obs@ooruri.kusastro.kyoto-u.ac.jp
# Time-series data may be sent to vsnet-campaign-report@ooruri.kusastro.kyoto-u.ac.jp
Mean magnitude and position on the discovery images:
2026 05 20.1487 2461180.6487 14.85 09:18:43.83 +18:02:53.3
211.73613 40.42386 galactic Cnc Second-epoch detections are separated by 0.5" and 1.7 pix
The object was not found in VSX
The object was not found in ASASSN-V
The object was found in astcheck.366 Vincentina -5 1 5 14.8 -0 0
Forced photometry on wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits at 09:18:43.83 +18:02:53.3: 16.15 +/- 99.00 upperlimit
Forced photometry on wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits at 09:18:43.83 +18:02:53.3: 16.24 +/- 99.00 upperlimit
Check this position in TNS.Manually check the ASAS-SN list of transients!Search this object in SIMBAD.Search this object in VizieR catalogs.WISE atlasAladin LiteSNAD ZTF viewer
Online MPChecker may fail to identify bright comets! Please manually check the Seiichi Yoshida's and Gideon van Buitenen's pages.
Don't forget to copy the leading white spaces and change the observatory code!
The code 'C32' is 'Ka-Dar Observatory, TAU Station, Nizhny Arkhyz', the code '500' is the geocenter.
Make sure there are no trailing white spaces after the observatory code.
The string should be exactly 80 characters long to conform to the MPC format.
Mean position:
You may copy/paste the above measurements to the following online services: MPChecker (in case the button does not work) NEOCMTChecker (NEO's and comets) sat_id2 (artificial satellites; needs at least two observations to work) fitsblink_satellites (art. sat.; you'll need to save the astrometry as a text file and upload it)
Here is a stub line for reporting a new transient to the TOCP.
Don't forget to set the constellation name and the number of days since the last non-detection!
Don't forget to change the observer code for the AAVSO and VSNET format data!
**** AAVSO file format ****
#TYPE=EXTENDED
#OBSCODE=SKA
#SOFTWARE=VaST 1.0rc90 transient pipeline
#DELIM=,
#DATE=JD
#NAME,DATE,MAG,MERR,FILT,TRANS,MTYPE,CNAME,CMAG,KNAME,KMAG,AMASS,GROUP,CHART,NOTES
VARIABLE_NAME,2461180.6487,14.85,0.05,CV,NO,STD,ENSEMBLE,na,na,na,na,1,na,NMW-TexasTech Camera-2 135mm f/2.2 telephoto lens + QHY600M CMOS
**** VSNET file format ****
# Here are some valid formatiing examples:
#CETFZ 20230815.9829 <13.5CV NMW
#CETFZ 20230818.9746 12.5CV NMW
#CETFZ 20230819.9732 12.6CV NMW
#TCPJ17453768-1756253 20230831.7290 12.7CV NMW
VARIABLE_NAME 20260520.1487 14.85CV NMW
The AAVSO data should be submitted to https://www.aavso.org/webobs
The VSNET data, depending on how interesting the target is, should be e-mailed to
vsnet-alert@ooruri.kusastro.kyoto-u.ac.jp
vsnet-outburst-wanted@ooruri.kusastro.kyoto-u.ac.jp
vsnet-obs@ooruri.kusastro.kyoto-u.ac.jp
# Time-series data may be sent to vsnet-campaign-report@ooruri.kusastro.kyoto-u.ac.jp
## VaST run with SExtractor config file default.sex.telephoto_lens_onlybrightstars_v1 ##
Images processed 4
Images used for photometry 4
Ref. image: 2461093.71767653 22.02.2026 05:13:17.252 /data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits
First image: 2461093.71767653 22.02.2026 05:13:17.252 /data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits
Last image: 2461180.64889861 20.05.2026 03:34:14.840 /data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits
JD time system (TT/UTC/UNKNOWN): UTC
Transient candidates found: 2
FILTER key from ref. img. header: CV
Magnitude scale: instrumental
Estimated ref. image limiting mag.: -7.54
Magnitude-Size filter: Disabled
For each source choose aperture with the smallest scatter: YES
Photometric errors rescaling: NO
Number of identified bad images: 0
Number of SysRem iterations: 0
User-specified moving object: none
Computation time: 3 seconds
Number of parallel threads: 24
SExtractor parameter file: default.sex
Some important SExtractor parameters:
DETECT_MINAREA 10.0 # minimum number of pixels above threshold
DETECT_THRESH 10.0 # or , in mag.arcsec-2
ANALYSIS_THRESH 10.0 # or , in mag.arcsec-2
SATUR_LEVEL 55000.0 # level (in ADUs) at which arises saturation
GAIN 0.37 # detector gain in e-/ADU
Total objects detected (at least 2 times): 5867
Objects passed selection criteria: 5859
Measurements per detected object (mean, median, min, max): 3.3 4.0 2 4
Measurements per selected object (mean, median, min, max): 3.3 4.0 2 4
Average stars detected per image: 5838.25
Average stars matched: 5190 (88.8965 %)
Memory usage VmPeak: 113388 kB
Software: VaST 1.0rc90 compiled with gcc (Gentoo 15.2.1_p20260214 p5) 15.2.1 20260214
VaST compiled on Tue May 19 15:05:05 CDT 2026
VaST build number 1.0rc89-63-g0e0f9022
OpenMP enabled: Yes
SExtractor version 2.19.5 (2026-05-19)
GNU bash, version 5.3.9(1)-release (x86_64-pc-linux-gnu)
Processing completed on Tue May 19 22:41:31 CDT 2026
Host name: tau
############################################################
## VaST run with SExtractor config file default.sex.telephoto_lens_vSTL ##
Images processed 4
Images used for photometry 4
Ref. image: 2461093.71767653 22.02.2026 05:13:17.252 /data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits
First image: 2461093.71767653 22.02.2026 05:13:17.252 /data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits
Last image: 2461180.64889861 20.05.2026 03:34:14.840 /data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits
JD time system (TT/UTC/UNKNOWN): UTC
Transient candidates found: 109
FILTER key from ref. img. header: CV
Magnitude scale: instrumental
Estimated ref. image limiting mag.: -7.24
Magnitude-Size filter: Disabled
For each source choose aperture with the smallest scatter: YES
Photometric errors rescaling: NO
Number of identified bad images: 0
Number of SysRem iterations: 0
User-specified moving object: none
Computation time: 12 seconds
Number of parallel threads: 24
SExtractor parameter file: default.sex
Some important SExtractor parameters:
DETECT_MINAREA 2.0 # minimum number of pixels above threshold
DETECT_THRESH 3.0 # or , in mag.arcsec-2
ANALYSIS_THRESH 3.0 # or , in mag.arcsec-2
SATUR_LEVEL 57000.0 # level (in ADUs) at which arises saturation
GAIN 0.83 # detector gain in e-/ADU
WEIGHT_TYPE BACKGROUND
Total objects detected (at least 2 times): 34167
Objects passed selection criteria: 34084
Measurements per detected object (mean, median, min, max): 3.4 4.0 2 4
Measurements per selected object (mean, median, min, max): 3.4 4.0 2 4
Average stars detected per image: 34119.2
Average stars matched: 30999.8 (90.8571 %)
Memory usage VmPeak: 142564 kB
Software: VaST 1.0rc90 compiled with gcc (Gentoo 15.2.1_p20260214 p5) 15.2.1 20260214
VaST compiled on Tue May 19 15:05:05 CDT 2026
VaST build number 1.0rc89-63-g0e0f9022
OpenMP enabled: Yes
SExtractor version 2.19.5 (2026-05-19)
GNU bash, version 5.3.9(1)-release (x86_64-pc-linux-gnu)
Processing completed on Tue May 19 22:42:52 CDT 2026
Host name: tau
############################################################
Updating neverexclude_list.txt
'/var/www/nmw_calibration/neverexclude_list.txt' -> './neverexclude_list.txt'
Choosing bad regions list
'/var/www/nmw_calibration/TTUQ2b1x1/TTUQ2_bad_region.lst' -> 'bad_region.lst'
wait
*------ default.sex.telephoto_lens_onlybrightstars_v1 ------*
'default.sex.telephoto_lens_onlybrightstars_v1' -> 'default.sex'
Starting VaST with default.sex.telephoto_lens_onlybrightstars_v1
./vast --norotation --noflagimage --starmatchraius 4 --matchstarnumber 500 --selectbestaperture --sysrem 0 --type 4 --maxsextractorflag 99 --UTC --nofind --nojdkeyword /data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits /data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits /data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits /data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits
SExtractor catalog cache: saved Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits.cat to cache
SExtractor catalog cache: saved Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits.cat to cache
VaST run complete with default.sex.telephoto_lens_onlybrightstars_v1
The four input images were /data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits /data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits /data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits /data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits
Checking WCS cache directory local_wcs_cache
Checking WCS cache directory /mnt/usb/NMW_NG/solved_reference_images
Found WCS cache directory /mnt/usb/NMW_NG/solved_reference_images
Checking WCS cache directory /home/NMW_web_upload/solved_reference_images
Checking WCS cache directory /dataX/kirx/NMW_NG_rt3_autumn2019/solved_reference_images
The reference JD(UT) for computing planet and comet positions: 2461180.64846500
Re-using ../tocp_transients_list.txt
'../tocp_transients_list.txt' -> 'tocp_transients_list.txt'
Re-using ../tns_transients_list.txt
'../tns_transients_list.txt' -> 'tns_transients_list.txt'
Plate-solving the images
'../asassn_transients_list.txt' -> 'asassn_transients_list.txt'
wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits exists and is non-empty
Saving wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits to local_wcs_cache/
'wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits' -> 'local_wcs_cache/wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits'
wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits exists and is non-empty
Saving wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits to local_wcs_cache/
'wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits' -> 'local_wcs_cache/wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits'
wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits exists and is non-empty
Saving wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits to local_wcs_cache/
'wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits' -> 'local_wcs_cache/wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits'
wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits exists and is non-empty
Saving wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits to local_wcs_cache/
'wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits' -> 'local_wcs_cache/wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits'
###################################
# fov_of_wcs_calibrated_image.sh output for wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits (1st reference image)
verification OK: wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits
Image size: 941.6'x627.1' 15.7(deg)x10.5(deg) 9576x6388 pix
Image scale: 5.90"/pix along the X axis and 5.89"/pix along the Y axis
Image center: 09:13:48.344 +22:00:23.49 J2000 4789.000 3195.000
###################################
The image scale is 5.90"/pix, setting the soft and hard astrometric limits for filtering second-epoch detections: 5.9" and 8.9"
###################################
# fov_of_wcs_calibrated_image.sh output for wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits (1st new image)
verification OK: wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits
Image size: 937.2'x624.0' 15.6(deg)x10.4(deg) 9576x6388 pix
Image scale: 5.87"/pix along the X axis and 5.86"/pix along the Y axis
Image center: 09:14:16.008 +21:59:11.06 J2000 4789.000 3195.000
###################################
###################################
# Check the image center offset between the reference and the first second-epoch image (pointing accuracy)
Reference image center 09:13:48.344 +22:00:23.49
Second-epoch image center 09:14:16.008 +21:59:11.06
Angular distance between the image centers 0.1088 deg.
Soft limit: 0.50 deg. Hard limit: 1.00 deg.
###################################
###################################
# fov_of_wcs_calibrated_image.sh output for wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits (2nd new image)
verification OK: wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits
Image size: 937.3'x624.1' 15.6(deg)x10.4(deg) 9576x6388 pix
Image scale: 5.87"/pix along the X axis and 5.86"/pix along the Y axis
Image center: 09:14:15.737 +21:59:20.27 J2000 4789.000 3195.000
###################################
###################################
# Check the image center offset between the reference and the second second-epoch image (pointing accuracy)
Reference image center 09:13:48.344 +22:00:23.49
Second-epoch image center 09:14:15.737 +21:59:20.27
Angular distance between the image centers 0.1073 deg.
###################################
###################################
# Check the image center offset between the first and the second second-epoch image (shift should be applied between the second-epoch images)
Second-epoch first image center 09:14:16.008 +21:59:11.06
Second-epoch second image center 09:14:15.737 +21:59:20.27
Angular distance between the image centers 0.00276 deg.
###################################
Running solve_plate_with_UCAC5...
Preparing for ar aprallel run
Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits &> /tmp/tmp.TIURil76kD
Parallel run for /data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits
Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits &> /tmp/tmp.wjcXRbHRo1
Parallel run for /data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits
Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits &> /tmp/tmp.6e1Rkr9uBF
Parallel run for /data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits
Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits &> /tmp/tmp.3rpxc85hNd
Parallel run for /data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits
Calibrating the magnitude scale
Found non-empty wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits
____ Start of magnitude calibration ____
PHOTOMETRIC_CALIBRATION=TYCHO2_V
Calibrating the magnitude scale with Tycho-2 stars
util/transients/transient_factory_test31.sh is checking for the presence of non-empty wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits and wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits.cat
Tycho-2 catalog is found at lib/catalogs/tycho2
Tycho-2 catalog and the derived bright star exclusion list are ready
Checking for the presence of non-empty wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits and wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits.cat
Found non-empty wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits and wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits.cat
The reference image (wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits) and catalog (wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits.cat) found
'wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits.cat' -> 'wcsmag.cat'
Read 9037 stars from the SExtractor catalog wcsmag.cat
Detected star coordinate range: RA 129.4948 to 147.0612 deg, Dec +16.3333 to +27.3527 deg
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.00
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.01
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.02
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.03
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.04
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.05
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.06
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.07
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.08
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.09
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.10
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.11
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.12
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.13
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.14
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.15
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.16
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.17
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.18
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.19
Tycho-2 catalog search boundaries: RA 129.4948 to 147.0612 deg, Dec 16.3333 to 27.3527 deg
Loaded 6007 Tycho-2 stars within the image boundaries (VT and BT non-zero).
Relation between the catalog and instrumental magnitudes is written to calib.txt
Stars used for magnitude calibration (good matches): 4487 out of 4795 total matches.
Matched with Tycho-2 4795 out of 9037 detected stars.
The calibration function type and coefficients are written to calib.txt_param
util/calibrate_magnitude_scale 0.000000 1.000000 22.922000
a=0.000000 b=1.000000 c=22.922000
From vast_summary.log: estimated ref. image limiting mag.: -7.54
Updating vast_summary.log: Estimated ref. image limiting mag.: 15.38
Updated vast_limiting_magnitude.log with calibrated magnitudes
Working...
Please, PLEASE, be patient!!!
All lightcurves processed! =)
Estimated ref. image limiting mag.: 15.38
Lightcurve magnitude calibration plot:
Preparing per-reference-image forced-photometry calibration (method=tycho2 band=V)
Read 9037 stars from the SExtractor catalog wcsmag.cat
Detected star coordinate range: RA 129.4948 to 147.0612 deg, Dec +16.3333 to +27.3527 deg
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.00
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.01
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.02
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.03
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.04
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.05
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.06
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.07
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.08
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.09
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.10
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.11
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.12
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.13
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.14
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.15
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.16
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.17
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.18
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.19
Tycho-2 catalog search boundaries: RA 129.4948 to 147.0612 deg, Dec 16.3333 to 27.3527 deg
Loaded 6007 Tycho-2 stars within the image boundaries (VT and BT non-zero).
Relation between the catalog and instrumental magnitudes is written to calib.txt
Stars used for magnitude calibration (good matches): 4487 out of 4795 total matches.
Matched with Tycho-2 4795 out of 9037 detected stars.
util/calibrate_single_image_with_tycho2.sh: calibrated wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits via Tycho-2
Single-image forced-photometry magnitude calibration plot for wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits:
Forced-photometry filter: calibrated wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits -> calib.txt_param_ref_wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits (aperture=6.3)
Read 10096 stars from the SExtractor catalog wcsmag.cat
Detected star coordinate range: RA 129.9622 to 147.5472 deg, Dec +16.1747 to +27.5160 deg
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.00
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.01
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.02
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.03
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.04
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.05
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.06
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.07
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.08
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.09
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.10
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.11
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.12
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.13
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.14
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.15
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.16
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.17
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.18
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.19
Tycho-2 catalog search boundaries: RA 129.9622 to 147.5472 deg, Dec 16.1747 to 27.5160 deg
Loaded 6109 Tycho-2 stars within the image boundaries (VT and BT non-zero).
Relation between the catalog and instrumental magnitudes is written to calib.txt
Stars used for magnitude calibration (good matches): 4505 out of 4764 total matches.
Matched with Tycho-2 4764 out of 10096 detected stars.
util/calibrate_single_image_with_tycho2.sh: calibrated wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits via Tycho-2
Single-image forced-photometry magnitude calibration plot for wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits:
Forced-photometry filter: calibrated wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits -> calib.txt_param_ref_wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits (aperture=6.5)
____ End of magnitude calibration ____
Applying consolidated magnitude filters...
Preparing the exclusion lists for this field
Done with filtering
Found 2 candidate transients before the final filtering. (Hard limit: 8000)
Median FWHM seeing for isolated stars:
2.2 pix Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits
2.4 pix Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits
2.5 pix fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits
2.5 pix fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits
2.2 pix wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits
2.4 pix wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits
Limiting magnitude estimates:
15.4 mag. Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits
15.5 mag. Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits
14.9 mag. fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits
14.9 mag. fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits
All-image limiting magnitude estimate: 14.9 (SNR ) 11.9 (80% of stars) with default.sex.telephoto_lens_onlybrightstars_v1
The first estimate is the magnitude of a star detected with a signal-to-noise ratio of following Karpov (2025, Acta Polytechnica, 65, 50).
This value should be representative of the faintest stars clearly visible in the image.
The brighter of the limiting magnitude estimates for the two second-epoch images is reported here.
The second estimate is the 80th percentile of the magnitude distribution of stars detected on all four images.
This value is representative of the faintest object that may enter the candidate transients list.
The hard cut-off for the candidate transients is 15.0 mag.
Waiting for UCAC5 plate solver
wait
############ /tmp/tmp.TIURil76kD (6) ############
Parsing command line arguments...
WARNING from replace_file_with_symlink_if_filename_contains_white_spaces() the input file /data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits is already a symlink and we do not allow symlinks on symlinks
The guess is based on the existing WCS header.
Trying to blindly solve the plate (local solve-field or remote server)...
/data_ssd/NMW-TexasTech/workdir/vast_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits 573.0
Entering WCS image calibration mode.
ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits
FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits
WARNING from replace_file_with_symlink_if_filename_contains_white_spaces() the input file /data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits is already a symlink and we do not allow symlinks on symlinks
FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits
verification OK: /data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits
It's a known telescope with plate solutions that are supposed to be good.
The input image /data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits has a WCS header - will blindly trust it is good...
'/data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits' -> 'wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits'
FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits
WCS_IMAGE_NAME=wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits
WCS-calibrated image found: wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits
Checking if the catalog wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits.cat corresponding to the image wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits alredy exist and is non-empty...
Catalog wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits.cat corresponding to the image wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits found.
The catalog is in the new format, as expected.
The plate-solved (WCS-calibrated) image is saved to wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits
util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits
WCS catalog name: wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits.cat
SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=0, blended=724, passed=9037
Got 9037 stars (including 8310 good ones) from the SExtractor catalog wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits.cat
util/solve_plate_with_UCAC5 got 9037 stars from the SExtractor catalog
Updated FoV from the plate-solved image: 941.6'
Seting catalog search parameters based on the expected field of view 941.6 arcmin
UCAC5 catalog search parameters:
catalog_search_parameters->search_radius_deg= 0.013078 (47.1 arcsec)
catalog_search_parameters->brightest_mag= 1.00
catalog_search_parameters->faintest_mag= 13.50
catalog_search_parameters->search_radius_second_step_deg 0.010462 (37.7 arcsec)
ITERATION 01 -- talking to VizieR, this might be slow!
UCAC5 search strategy: trying local copy first
Found a local copy of UCAC5
Reading UCAC5 zone files...
Searching UCAC5 zones 531 to 588 (Dec 16.3 to 27.4)
Done reading UCAC5 zone files...
Matched 958 stars with the local copy of UCAC5.
The local UCAC5 search seems to be a success
Correcting the measured astrometric positions...
Accuracy estimation diagnostic: 958 matched stars entering correct_measured_positions(), 949 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.41"
Removing outliers...
Correcting the measured astrometric positions...
Accuracy estimation diagnostic: 958 matched stars entering correct_measured_positions(), 8949 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.38"
ITERATION 02 -- talking to VizieR, this might be slow!
UCAC5 search strategy: trying local copy first
Found a local copy of UCAC5
Reading UCAC5 zone files...
Searching UCAC5 zones 531 to 588 (Dec 16.3 to 27.4)
Done reading UCAC5 zone files...
Matched 958 stars with the local copy of UCAC5.
The local UCAC5 search seems to be a success
Accuracy estimation diagnostic: 958 matched stars entering correct_measured_positions(), 8948 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.38"
Accuracy estimation diagnostic: 958 matched stars entering correct_measured_positions(), 8948 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.39"
Excluding outliers - 958 stars left (next iteration limit 1053)
Stop iterations.
The field is successfully solved and matched with the astrometric catalog! :)
WCS_QUALITY_DIAG: file=Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits N_match=958 sigma_overall_arcsec=0.407 sigma_q1_arcsec=0.483 sigma_q2_arcsec=0.443 sigma_q3_arcsec=0.392 sigma_q4_arcsec=0.345 n_q1=262 n_q2=201 n_q3=256 n_q4=239 worst_quadrant_to_overall_ratio=1.185
The image catalog is written to wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits.cat.ucac5
The DS9 region file with the matched stars is written to wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits.cat.ds9.reg
You may view it with the command:
ds9 /data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits -region wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits.cat.ds9.reg
The astrometric residuals vector field is written to wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits.cat.astrometric_residuals
Option '-n' not using photometric catalogs, just stick with astrometry
opt '-i': 2 is the maximum number of iterations
############ /tmp/tmp.wjcXRbHRo1 (6) ############
Parsing command line arguments...
The guess is based on the existing WCS header.
Trying to blindly solve the plate (local solve-field or remote server)...
/data_ssd/NMW-TexasTech/workdir/vast_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits 570.0
Entering WCS image calibration mode.
ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits
FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits
FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits
verification OK: /data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits
It's a known telescope with plate solutions that are supposed to be good.
The input image /data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits has a WCS header - will blindly trust it is good...
'/data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits' -> 'wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits'
FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits
WCS_IMAGE_NAME=wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits
WCS-calibrated image found: wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits
Checking if the catalog wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits.cat corresponding to the image wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits alredy exist and is non-empty...
Catalog wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits.cat corresponding to the image wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits found.
The catalog is in the new format, as expected.
The plate-solved (WCS-calibrated) image is saved to wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits
util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits
WCS catalog name: wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits.cat
SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=0, blended=699, passed=10096
Got 10096 stars (including 9392 good ones) from the SExtractor catalog wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits.cat
util/solve_plate_with_UCAC5 got 10096 stars from the SExtractor catalog
Updated FoV from the plate-solved image: 937.6'
Seting catalog search parameters based on the expected field of view 937.6 arcmin
UCAC5 catalog search parameters:
catalog_search_parameters->search_radius_deg= 0.013022 (46.9 arcsec)
catalog_search_parameters->brightest_mag= 1.00
catalog_search_parameters->faintest_mag= 13.50
catalog_search_parameters->search_radius_second_step_deg 0.010418 (37.5 arcsec)
ITERATION 01 -- talking to VizieR, this might be slow!
UCAC5 search strategy: trying local copy first
Found a local copy of UCAC5
Reading UCAC5 zone files...
Searching UCAC5 zones 530 to 589 (Dec 16.2 to 27.5)
Done reading UCAC5 zone files...
Matched 960 stars with the local copy of UCAC5.
The local UCAC5 search seems to be a success
Correcting the measured astrometric positions...
Accuracy estimation diagnostic: 960 matched stars entering correct_measured_positions(), 944 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.51"
Removing outliers...
Correcting the measured astrometric positions...
Accuracy estimation diagnostic: 960 matched stars entering correct_measured_positions(), 9955 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.47"
ITERATION 02 -- talking to VizieR, this might be slow!
UCAC5 search strategy: trying local copy first
Found a local copy of UCAC5
Reading UCAC5 zone files...
Searching UCAC5 zones 530 to 589 (Dec 16.2 to 27.5)
Done reading UCAC5 zone files...
Matched 960 stars with the local copy of UCAC5.
The local UCAC5 search seems to be a success
Accuracy estimation diagnostic: 960 matched stars entering correct_measured_positions(), 9955 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.47"
Accuracy estimation diagnostic: 960 matched stars entering correct_measured_positions(), 9955 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.50"
Excluding outliers - 960 stars left (next iteration limit 1056)
Stop iterations.
The field is successfully solved and matched with the astrometric catalog! :)
WCS_QUALITY_DIAG: file=Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits N_match=960 sigma_overall_arcsec=0.502 sigma_q1_arcsec=0.327 sigma_q2_arcsec=0.737 sigma_q3_arcsec=0.488 sigma_q4_arcsec=0.501 n_q1=207 n_q2=267 n_q3=191 n_q4=295 worst_quadrant_to_overall_ratio=1.466
The image catalog is written to wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits.cat.ucac5
The DS9 region file with the matched stars is written to wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits.cat.ds9.reg
You may view it with the command:
ds9 /data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits -region wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits.cat.ds9.reg
The astrometric residuals vector field is written to wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits.cat.astrometric_residuals
Option '-n' not using photometric catalogs, just stick with astrometry
opt '-i': 2 is the maximum number of iterations
############ /tmp/tmp.6e1Rkr9uBF (6) ############
Parsing command line arguments...
The minor axis of the CCD chip should be 24.0 mm based on the derived pixel size of 3.8 um
Internal estimated FoV 605.3'
The guess is based on the FOCALLEN keyword.
Trying to blindly solve the plate (local solve-field or remote server)...
/data_ssd/NMW-TexasTech/workdir/vast_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits 605.0
Entering WCS image calibration mode.
ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits
FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits
FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits
verification OK: /data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits
It's not one of the telescopes that are know to produce images with good WCS solutions - will try to re-solve!
FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits
WCS_IMAGE_NAME=wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits
WCS-calibrated image found: wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits
Checking if the catalog wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits.cat corresponding to the image wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits alredy exist and is non-empty...
Catalog wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits.cat corresponding to the image wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits found.
The catalog is in the new format, as expected.
The plate-solved (WCS-calibrated) image is saved to wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits
util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits
WCS catalog name: wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits.cat
SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=0, blended=385, passed=6370
Got 6370 stars (including 5981 good ones) from the SExtractor catalog wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits.cat
util/solve_plate_with_UCAC5 got 6370 stars from the SExtractor catalog
Updated FoV from the plate-solved image: 937.2'
Seting catalog search parameters based on the expected field of view 937.2 arcmin
UCAC5 catalog search parameters:
catalog_search_parameters->search_radius_deg= 0.013017 (46.9 arcsec)
catalog_search_parameters->brightest_mag= 1.00
catalog_search_parameters->faintest_mag= 13.50
catalog_search_parameters->search_radius_second_step_deg 0.010413 (37.5 arcsec)
ITERATION 01 -- talking to VizieR, this might be slow!
UCAC5 search strategy: trying local copy first
Found a local copy of UCAC5
Reading UCAC5 zone files...
Searching UCAC5 zones 532 to 588 (Dec 16.5 to 27.3)
Done reading UCAC5 zone files...
Matched 954 stars with the local copy of UCAC5.
The local UCAC5 search seems to be a success
Correcting the measured astrometric positions...
Accuracy estimation diagnostic: 954 matched stars entering correct_measured_positions(), 942 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.50"
Removing outliers...
Correcting the measured astrometric positions...
Accuracy estimation diagnostic: 954 matched stars entering correct_measured_positions(), 6283 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.46"
ITERATION 02 -- talking to VizieR, this might be slow!
UCAC5 search strategy: trying local copy first
Found a local copy of UCAC5
Reading UCAC5 zone files...
Searching UCAC5 zones 532 to 588 (Dec 16.5 to 27.3)
Done reading UCAC5 zone files...
Matched 954 stars with the local copy of UCAC5.
The local UCAC5 search seems to be a success
Accuracy estimation diagnostic: 954 matched stars entering correct_measured_positions(), 6285 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.46"
Accuracy estimation diagnostic: 954 matched stars entering correct_measured_positions(), 6285 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.47"
Excluding outliers - 954 stars left (next iteration limit 1049)
Stop iterations.
The field is successfully solved and matched with the astrometric catalog! :)
WCS_QUALITY_DIAG: file=fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits N_match=954 sigma_overall_arcsec=0.517 sigma_q1_arcsec=0.396 sigma_q2_arcsec=0.628 sigma_q3_arcsec=0.424 sigma_q4_arcsec=0.570 n_q1=204 n_q2=262 n_q3=193 n_q4=295 worst_quadrant_to_overall_ratio=1.214
The image catalog is written to wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits.cat.ucac5
The DS9 region file with the matched stars is written to wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits.cat.ds9.reg
You may view it with the command:
ds9 /data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits -region wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits.cat.ds9.reg
The astrometric residuals vector field is written to wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits.cat.astrometric_residuals
Option '-n' not using photometric catalogs, just stick with astrometry
opt '-i': 2 is the maximum number of iterations
############ /tmp/tmp.3rpxc85hNd (6) ############
Parsing command line arguments...
The minor axis of the CCD chip should be 24.0 mm based on the derived pixel size of 3.8 um
Internal estimated FoV 605.3'
The guess is based on the FOCALLEN keyword.
Trying to blindly solve the plate (local solve-field or remote server)...
/data_ssd/NMW-TexasTech/workdir/vast_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits 605.0
Entering WCS image calibration mode.
ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits
FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits
FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits
verification OK: /data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits
It's not one of the telescopes that are know to produce images with good WCS solutions - will try to re-solve!
FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits
WCS_IMAGE_NAME=wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits
WCS-calibrated image found: wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits
Checking if the catalog wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits.cat corresponding to the image wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits alredy exist and is non-empty...
Catalog wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits.cat corresponding to the image wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits found.
The catalog is in the new format, as expected.
The plate-solved (WCS-calibrated) image is saved to wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits
util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits
WCS catalog name: wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits.cat
SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=0, blended=380, passed=6435
Got 6435 stars (including 6051 good ones) from the SExtractor catalog wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits.cat
util/solve_plate_with_UCAC5 got 6435 stars from the SExtractor catalog
Updated FoV from the plate-solved image: 937.3'
Seting catalog search parameters based on the expected field of view 937.3 arcmin
UCAC5 catalog search parameters:
catalog_search_parameters->search_radius_deg= 0.013018 (46.9 arcsec)
catalog_search_parameters->brightest_mag= 1.00
catalog_search_parameters->faintest_mag= 13.50
catalog_search_parameters->search_radius_second_step_deg 0.010414 (37.5 arcsec)
ITERATION 01 -- talking to VizieR, this might be slow!
UCAC5 search strategy: trying local copy first
Found a local copy of UCAC5
Reading UCAC5 zone files...
Searching UCAC5 zones 532 to 588 (Dec 16.6 to 27.3)
Done reading UCAC5 zone files...
Matched 954 stars with the local copy of UCAC5.
The local UCAC5 search seems to be a success
Correcting the measured astrometric positions...
Accuracy estimation diagnostic: 954 matched stars entering correct_measured_positions(), 942 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.52"
Removing outliers...
Correcting the measured astrometric positions...
Accuracy estimation diagnostic: 954 matched stars entering correct_measured_positions(), 6331 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.49"
ITERATION 02 -- talking to VizieR, this might be slow!
UCAC5 search strategy: trying local copy first
Found a local copy of UCAC5
Reading UCAC5 zone files...
Searching UCAC5 zones 532 to 588 (Dec 16.6 to 27.3)
Done reading UCAC5 zone files...
Matched 954 stars with the local copy of UCAC5.
The local UCAC5 search seems to be a success
Accuracy estimation diagnostic: 954 matched stars entering correct_measured_positions(), 6330 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.49"
Accuracy estimation diagnostic: 954 matched stars entering correct_measured_positions(), 6330 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.49"
Excluding outliers - 954 stars left (next iteration limit 1049)
Stop iterations.
The field is successfully solved and matched with the astrometric catalog! :)
WCS_QUALITY_DIAG: file=fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits N_match=954 sigma_overall_arcsec=0.532 sigma_q1_arcsec=0.391 sigma_q2_arcsec=0.591 sigma_q3_arcsec=0.451 sigma_q4_arcsec=0.609 n_q1=200 n_q2=263 n_q3=189 n_q4=302 worst_quadrant_to_overall_ratio=1.145
The image catalog is written to wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits.cat.ucac5
The DS9 region file with the matched stars is written to wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits.cat.ds9.reg
You may view it with the command:
ds9 /data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits -region wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits.cat.ds9.reg
The astrometric residuals vector field is written to wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits.cat.astrometric_residuals
Option '-n' not using photometric catalogs, just stick with astrometry
opt '-i': 2 is the maximum number of iterations
###################################
# Pre-local-correction WCS quality summary (see WCS_QUALITY_DIAG lines above)
ref1=Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits sigma_overall=0.407 worst_q_ratio=1.185
ref2=Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits sigma_overall=0.502 worst_q_ratio=1.466
new1=fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits sigma_overall=0.517 worst_q_ratio=1.214
new2=fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits sigma_overall=0.532 worst_q_ratio=1.145
reference average sigma_overall=0.4545 worst_q_ratio=1.3255
warn-on-ratio threshold: 2.0x reference
###################################
Distribution of catalog-matched stars across the image:
plot_astrometric_residuals_xy: wrote wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200_astrometric_residuals.png (958 matched stars from wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits.cat.astrometric_residuals, image 9576x6388)
plot_astrometric_residuals_xy: wrote wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202_astrometric_residuals.png (960 matched stars from wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits.cat.astrometric_residuals, image 9576x6388)
plot_astrometric_residuals_xy: wrote wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070_astrometric_residuals.png (954 matched stars from wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits.cat.astrometric_residuals, image 9576x6388)
plot_astrometric_residuals_xy: wrote wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071_astrometric_residuals.png (954 matched stars from wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits.cat.astrometric_residuals, image 9576x6388)
Copying WCS-calibrated images back to input directory
Saving fully-calibrated image wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits
INFO: FPACK_FULLY_CALIBRATED_IMAGE=no (not compressing the image)
'wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits' -> '/data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits'
Saving fully-calibrated image wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits
INFO: FPACK_FULLY_CALIBRATED_IMAGE=no (not compressing the image)
'wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits' -> '/data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits'
Preparing the HTML report for the field Cnc-03-Q2b1x1 with default.sex.telephoto_lens_onlybrightstars_v1
Forced photometry on wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits at 09:16:47.32 +17:53:44.1: 15.95 +/- 99.00 upperlimit
Forced photometry on wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits at 09:16:47.32 +17:53:44.1: 16.03 +/- 99.00 upperlimit
Adding exclusion_list_local.txt__out22523.dat to exclusion_list_local.txt
make_report_in_HTML.sh Phase 1 (network queries): 5s
Pre-generating preview images in parallel...
Done pre-generating preview images.
Pre-generating finding charts in parallel...
Done pre-generating finding charts.
make_report_in_HTML.sh Pre-generation: 1s
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 22523_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
Preparing report for the candidate 22523_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 22527_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 22527_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
**** FOUND 09:01:03.28 +17:53:55.5 in the exclusion list exclusion_list.txt ****
make_report_in_HTML.sh Phase 2 (HTML assembly): 0s
make_report_in_HTML.sh TOTAL: 6s
Prepared the HTML report for the field Cnc-03-Q2b1x1 with default.sex.telephoto_lens_onlybrightstars_v1
*------ done with default.sex.telephoto_lens_onlybrightstars_v1 ------*
#### The local exclusion list is exclusion_list_local.txt ####
09:16:47.32 +17:53:44.1
wait
*------ default.sex.telephoto_lens_vSTL ------*
'default.sex.telephoto_lens_vSTL' -> 'default.sex'
Starting VaST with default.sex.telephoto_lens_vSTL
./vast --norotation --noflagimage --starmatchraius 4 --matchstarnumber 500 --selectbestaperture --sysrem 0 --type 4 --maxsextractorflag 99 --UTC --nofind --nojdkeyword /data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits /data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits /data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits /data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits
SExtractor catalog cache: saved Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits.cat to cache
SExtractor catalog cache: saved Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits.cat to cache
VaST run complete with default.sex.telephoto_lens_vSTL
The four input images were /data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits /data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits /data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits /data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits
Checking WCS cache directory local_wcs_cache
Found WCS cache directory local_wcs_cache
Creating symlink local_wcs_cache/wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits
Creating symlink local_wcs_cache/wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits
Creating symlink local_wcs_cache/wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits
Creating symlink local_wcs_cache/wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits
Creating symlink local_wcs_cache/exclusion_list.txt
Checking WCS cache directory /mnt/usb/NMW_NG/solved_reference_images
Found WCS cache directory /mnt/usb/NMW_NG/solved_reference_images
Checking WCS cache directory /home/NMW_web_upload/solved_reference_images
Checking WCS cache directory /dataX/kirx/NMW_NG_rt3_autumn2019/solved_reference_images
Plate-solving the images
wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits exists and is non-empty
wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits exists and is non-empty
wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits exists and is non-empty
wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits exists and is non-empty
###################################
# fov_of_wcs_calibrated_image.sh output for wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits (1st reference image)
verification OK: wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits
Image size: 941.6'x627.1' 15.7(deg)x10.5(deg) 9576x6388 pix
Image scale: 5.90"/pix along the X axis and 5.89"/pix along the Y axis
Image center: 09:13:48.344 +22:00:23.49 J2000 4789.000 3195.000
###################################
The image scale is 5.90"/pix, setting the soft and hard astrometric limits for filtering second-epoch detections: 5.9" and 8.9"
###################################
# fov_of_wcs_calibrated_image.sh output for wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits (1st new image)
verification OK: wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits
Image size: 937.2'x624.0' 15.6(deg)x10.4(deg) 9576x6388 pix
Image scale: 5.87"/pix along the X axis and 5.86"/pix along the Y axis
Image center: 09:14:16.008 +21:59:11.06 J2000 4789.000 3195.000
###################################
###################################
# Check the image center offset between the reference and the first second-epoch image (pointing accuracy)
Reference image center 09:13:48.344 +22:00:23.49
Second-epoch image center 09:14:16.008 +21:59:11.06
Angular distance between the image centers 0.1088 deg.
Soft limit: 0.50 deg. Hard limit: 1.00 deg.
###################################
###################################
# fov_of_wcs_calibrated_image.sh output for wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits (2nd new image)
verification OK: wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits
Image size: 937.3'x624.1' 15.6(deg)x10.4(deg) 9576x6388 pix
Image scale: 5.87"/pix along the X axis and 5.86"/pix along the Y axis
Image center: 09:14:15.737 +21:59:20.27 J2000 4789.000 3195.000
###################################
###################################
# Check the image center offset between the reference and the second second-epoch image (pointing accuracy)
Reference image center 09:13:48.344 +22:00:23.49
Second-epoch image center 09:14:15.737 +21:59:20.27
Angular distance between the image centers 0.1073 deg.
###################################
###################################
# Check the image center offset between the first and the second second-epoch image (shift should be applied between the second-epoch images)
Second-epoch first image center 09:14:16.008 +21:59:11.06
Second-epoch second image center 09:14:15.737 +21:59:20.27
Angular distance between the image centers 0.00276 deg.
###################################
Running solve_plate_with_UCAC5...
Preparing for ar aprallel run
Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits &> /tmp/tmp.DcPVirZtEC
Parallel run for /data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits
Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits &> /tmp/tmp.6iWepcBLYq
Parallel run for /data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits
Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits &> /tmp/tmp.RFELCvqkTi
Parallel run for /data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits
Running util/solve_plate_with_UCAC5 --no_photometric_catalog --iterations 2 /data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits &> /tmp/tmp.DCFbNK8ByH
Parallel run for /data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits
Calibrating the magnitude scale
Found non-empty wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits
____ Start of magnitude calibration ____
PHOTOMETRIC_CALIBRATION=TYCHO2_V
Calibrating the magnitude scale with Tycho-2 stars
util/transients/transient_factory_test31.sh is checking for the presence of non-empty wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits and wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits.cat
Tycho-2 catalog is found at lib/catalogs/tycho2
Tycho-2 catalog and the derived bright star exclusion list are ready
Checking for the presence of non-empty wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits and wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits.cat
Found non-empty wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits and wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits.cat
The reference image (wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits) and catalog (wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits.cat) found
'wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits.cat' -> 'wcsmag.cat'
Read 50709 stars from the SExtractor catalog wcsmag.cat
Detected star coordinate range: RA 129.4922 to 147.0612 deg, Dec +16.3288 to +27.3568 deg
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.00
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.01
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.02
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.03
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.04
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.05
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.06
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.07
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.08
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.09
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.10
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.11
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.12
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.13
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.14
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.15
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.16
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.17
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.18
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.19
Tycho-2 catalog search boundaries: RA 129.4922 to 147.0612 deg, Dec 16.3288 to 27.3568 deg
Loaded 6019 Tycho-2 stars within the image boundaries (VT and BT non-zero).
Relation between the catalog and instrumental magnitudes is written to calib.txt
Stars used for magnitude calibration (good matches): 4180 out of 4844 total matches.
Matched with Tycho-2 4844 out of 50709 detected stars.
The calibration function type and coefficients are written to calib.txt_param
util/calibrate_magnitude_scale 0.000000 1.000000 22.805350
a=0.000000 b=1.000000 c=22.805350
From vast_summary.log: estimated ref. image limiting mag.: -7.24
Updating vast_summary.log: Estimated ref. image limiting mag.: 15.57
Updated vast_limiting_magnitude.log with calibrated magnitudes
Working...
Please, PLEASE, be patient!!!
All lightcurves processed! =)
Estimated ref. image limiting mag.: 15.57
Lightcurve magnitude calibration plot:
Preparing per-reference-image forced-photometry calibration (method=tycho2 band=V)
Read 50709 stars from the SExtractor catalog wcsmag.cat
Detected star coordinate range: RA 129.4922 to 147.0612 deg, Dec +16.3288 to +27.3568 deg
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.00
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.01
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.02
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.03
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.04
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.05
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.06
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.07
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.08
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.09
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.10
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.11
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.12
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.13
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.14
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.15
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.16
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.17
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.18
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.19
Tycho-2 catalog search boundaries: RA 129.4922 to 147.0612 deg, Dec 16.3288 to 27.3568 deg
Loaded 6019 Tycho-2 stars within the image boundaries (VT and BT non-zero).
Relation between the catalog and instrumental magnitudes is written to calib.txt
Stars used for magnitude calibration (good matches): 4180 out of 4844 total matches.
Matched with Tycho-2 4844 out of 50709 detected stars.
util/calibrate_single_image_with_tycho2.sh: calibrated wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits via Tycho-2
Single-image forced-photometry magnitude calibration plot for wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits:
Forced-photometry filter: calibrated wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits -> calib.txt_param_ref_wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits (aperture=4.9)
Read 49658 stars from the SExtractor catalog wcsmag.cat
Detected star coordinate range: RA 129.9572 to 147.5472 deg, Dec +16.1145 to +27.5204 deg
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.00
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.01
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.02
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.03
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.04
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.05
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.06
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.07
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.08
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.09
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.10
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.11
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.12
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.13
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.14
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.15
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.16
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.17
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.18
Reading Tycho2 catalog file lib/catalogs/tycho2/tyc2.dat.19
Tycho-2 catalog search boundaries: RA 129.9572 to 147.5472 deg, Dec 16.1145 to 27.5204 deg
Loaded 6139 Tycho-2 stars within the image boundaries (VT and BT non-zero).
Relation between the catalog and instrumental magnitudes is written to calib.txt
Stars used for magnitude calibration (good matches): 4212 out of 4779 total matches.
Matched with Tycho-2 4779 out of 49658 detected stars.
util/calibrate_single_image_with_tycho2.sh: calibrated wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits via Tycho-2
Single-image forced-photometry magnitude calibration plot for wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits:
Forced-photometry filter: calibrated wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits -> calib.txt_param_ref_wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits (aperture=5.1)
____ End of magnitude calibration ____
Applying consolidated magnitude filters...
Preparing the exclusion lists for this field
Done with filtering
Found 74 candidate transients before the final filtering. (Hard limit: 8000)
Median FWHM seeing for isolated stars:
2.0 pix Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits
2.2 pix Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits
2.2 pix fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits
2.2 pix fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits
2.0 pix wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits
2.2 pix wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits
Limiting magnitude estimates:
15.6 mag. Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits
15.7 mag. Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits
15.0 mag. fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits
15.1 mag. fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits
All-image limiting magnitude estimate: 15.0 (SNR ) 14.5 (80% of stars) with default.sex.telephoto_lens_vSTL
The first estimate is the magnitude of a star detected with a signal-to-noise ratio of following Karpov (2025, Acta Polytechnica, 65, 50).
This value should be representative of the faintest stars clearly visible in the image.
The brighter of the limiting magnitude estimates for the two second-epoch images is reported here.
The second estimate is the 80th percentile of the magnitude distribution of stars detected on all four images.
This value is representative of the faintest object that may enter the candidate transients list.
The hard cut-off for the candidate transients is 15.0 mag.
Waiting for UCAC5 plate solver
wait
############ /tmp/tmp.DcPVirZtEC (6) ############
Parsing command line arguments...
WARNING from replace_file_with_symlink_if_filename_contains_white_spaces() the input file /data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits is already a symlink and we do not allow symlinks on symlinks
The guess is based on the existing WCS header.
Trying to blindly solve the plate (local solve-field or remote server)...
/data_ssd/NMW-TexasTech/workdir/vast_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits 573.0
Entering WCS image calibration mode.
ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits
FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits
WARNING from replace_file_with_symlink_if_filename_contains_white_spaces() the input file /data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits is already a symlink and we do not allow symlinks on symlinks
FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits
verification OK: /data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits
It's a known telescope with plate solutions that are supposed to be good.
The input image /data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits has a WCS header - will blindly trust it is good...
'/data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits' -> 'wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits'
FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits
WCS_IMAGE_NAME=wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits
WCS-calibrated image found: wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits
Checking if the catalog wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits.cat corresponding to the image wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits alredy exist and is non-empty...
Catalog wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits.cat corresponding to the image wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits found.
The catalog is in the new format, as expected.
The plate-solved (WCS-calibrated) image is saved to wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits
util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits
WCS catalog name: wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits.cat
SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=29, blended=2904, passed=50680
Got 50680 stars (including 47694 good ones) from the SExtractor catalog wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits.cat
util/solve_plate_with_UCAC5 got 50680 stars from the SExtractor catalog
Updated FoV from the plate-solved image: 941.6'
Seting catalog search parameters based on the expected field of view 941.6 arcmin
UCAC5 catalog search parameters:
catalog_search_parameters->search_radius_deg= 0.013078 (47.1 arcsec)
catalog_search_parameters->brightest_mag= 1.00
catalog_search_parameters->faintest_mag= 13.50
catalog_search_parameters->search_radius_second_step_deg 0.010462 (37.7 arcsec)
ITERATION 01 -- talking to VizieR, this might be slow!
UCAC5 search strategy: trying local copy first
Found a local copy of UCAC5
Reading UCAC5 zone files...
Searching UCAC5 zones 531 to 588 (Dec 16.3 to 27.4)
Done reading UCAC5 zone files...
Matched 957 stars with the local copy of UCAC5.
The local UCAC5 search seems to be a success
Correcting the measured astrometric positions...
Accuracy estimation diagnostic: 957 matched stars entering correct_measured_positions(), 946 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.41"
Removing outliers...
Correcting the measured astrometric positions...
Accuracy estimation diagnostic: 957 matched stars entering correct_measured_positions(), 50198 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.40"
ITERATION 02 -- talking to VizieR, this might be slow!
UCAC5 search strategy: trying local copy first
Found a local copy of UCAC5
Reading UCAC5 zone files...
Searching UCAC5 zones 531 to 588 (Dec 16.3 to 27.4)
Done reading UCAC5 zone files...
Matched 957 stars with the local copy of UCAC5.
The local UCAC5 search seems to be a success
Accuracy estimation diagnostic: 957 matched stars entering correct_measured_positions(), 50198 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.40"
Accuracy estimation diagnostic: 957 matched stars entering correct_measured_positions(), 50198 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.42"
Excluding outliers - 957 stars left (next iteration limit 1052)
Stop iterations.
The field is successfully solved and matched with the astrometric catalog! :)
WCS_QUALITY_DIAG: file=Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits N_match=957 sigma_overall_arcsec=0.416 sigma_q1_arcsec=0.470 sigma_q2_arcsec=0.403 sigma_q3_arcsec=0.394 sigma_q4_arcsec=0.376 n_q1=259 n_q2=193 n_q3=261 n_q4=244 worst_quadrant_to_overall_ratio=1.130
The image catalog is written to wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits.cat.ucac5
The DS9 region file with the matched stars is written to wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits.cat.ds9.reg
You may view it with the command:
ds9 /data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits -region wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits.cat.ds9.reg
The astrometric residuals vector field is written to wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits.cat.astrometric_residuals
Option '-n' not using photometric catalogs, just stick with astrometry
opt '-i': 2 is the maximum number of iterations
############ /tmp/tmp.6iWepcBLYq (6) ############
Parsing command line arguments...
The guess is based on the existing WCS header.
Trying to blindly solve the plate (local solve-field or remote server)...
/data_ssd/NMW-TexasTech/workdir/vast_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits 570.0
Entering WCS image calibration mode.
ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits
FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits
FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits
verification OK: /data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits
It's a known telescope with plate solutions that are supposed to be good.
The input image /data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits has a WCS header - will blindly trust it is good...
'/data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits' -> 'wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits'
FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits
WCS_IMAGE_NAME=wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits
WCS-calibrated image found: wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits
Checking if the catalog wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits.cat corresponding to the image wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits alredy exist and is non-empty...
Catalog wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits.cat corresponding to the image wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits found.
The catalog is in the new format, as expected.
The plate-solved (WCS-calibrated) image is saved to wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits
util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits
WCS catalog name: wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits.cat
SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=18, blended=2988, passed=49640
Got 49640 stars (including 46592 good ones) from the SExtractor catalog wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits.cat
util/solve_plate_with_UCAC5 got 49640 stars from the SExtractor catalog
Updated FoV from the plate-solved image: 937.6'
Seting catalog search parameters based on the expected field of view 937.6 arcmin
UCAC5 catalog search parameters:
catalog_search_parameters->search_radius_deg= 0.013022 (46.9 arcsec)
catalog_search_parameters->brightest_mag= 1.00
catalog_search_parameters->faintest_mag= 13.50
catalog_search_parameters->search_radius_second_step_deg 0.010418 (37.5 arcsec)
ITERATION 01 -- talking to VizieR, this might be slow!
UCAC5 search strategy: trying local copy first
Found a local copy of UCAC5
Reading UCAC5 zone files...
Searching UCAC5 zones 530 to 589 (Dec 16.1 to 27.5)
Done reading UCAC5 zone files...
Matched 958 stars with the local copy of UCAC5.
The local UCAC5 search seems to be a success
Correcting the measured astrometric positions...
Accuracy estimation diagnostic: 958 matched stars entering correct_measured_positions(), 943 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.51"
Removing outliers...
Correcting the measured astrometric positions...
Accuracy estimation diagnostic: 958 matched stars entering correct_measured_positions(), 49030 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.48"
ITERATION 02 -- talking to VizieR, this might be slow!
UCAC5 search strategy: trying local copy first
Found a local copy of UCAC5
Reading UCAC5 zone files...
Searching UCAC5 zones 530 to 589 (Dec 16.1 to 27.5)
Done reading UCAC5 zone files...
Matched 958 stars with the local copy of UCAC5.
The local UCAC5 search seems to be a success
Accuracy estimation diagnostic: 958 matched stars entering correct_measured_positions(), 49027 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.48"
Accuracy estimation diagnostic: 958 matched stars entering correct_measured_positions(), 49027 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.50"
Excluding outliers - 958 stars left (next iteration limit 1053)
Stop iterations.
The field is successfully solved and matched with the astrometric catalog! :)
WCS_QUALITY_DIAG: file=Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits N_match=958 sigma_overall_arcsec=0.507 sigma_q1_arcsec=0.334 sigma_q2_arcsec=0.668 sigma_q3_arcsec=0.490 sigma_q4_arcsec=0.487 n_q1=218 n_q2=271 n_q3=183 n_q4=286 worst_quadrant_to_overall_ratio=1.318
The image catalog is written to wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits.cat.ucac5
The DS9 region file with the matched stars is written to wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits.cat.ds9.reg
You may view it with the command:
ds9 /data_ssd/NMW-TexasTech/reference_imgs/Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits -region wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits.cat.ds9.reg
The astrometric residuals vector field is written to wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits.cat.astrometric_residuals
Option '-n' not using photometric catalogs, just stick with astrometry
opt '-i': 2 is the maximum number of iterations
############ /tmp/tmp.RFELCvqkTi (6) ############
Parsing command line arguments...
The minor axis of the CCD chip should be 24.0 mm based on the derived pixel size of 3.8 um
Internal estimated FoV 605.3'
The guess is based on the FOCALLEN keyword.
Trying to blindly solve the plate (local solve-field or remote server)...
/data_ssd/NMW-TexasTech/workdir/vast_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits 605.0
Entering WCS image calibration mode.
ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits
FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits
FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits
verification OK: /data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits
It's not one of the telescopes that are know to produce images with good WCS solutions - will try to re-solve!
FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits
WCS_IMAGE_NAME=wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits
WCS-calibrated image found: wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits
Checking if the catalog wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits.cat corresponding to the image wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits alredy exist and is non-empty...
Catalog wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits.cat corresponding to the image wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits found.
The catalog is in the new format, as expected.
The plate-solved (WCS-calibrated) image is saved to wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits
util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits
WCS catalog name: wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits.cat
SExtractor catalog parsing summary: zero_flux=0, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=9, blended=1915, passed=35072
Got 35072 stars (including 33115 good ones) from the SExtractor catalog wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits.cat
util/solve_plate_with_UCAC5 got 35072 stars from the SExtractor catalog
Updated FoV from the plate-solved image: 937.2'
Seting catalog search parameters based on the expected field of view 937.2 arcmin
UCAC5 catalog search parameters:
catalog_search_parameters->search_radius_deg= 0.013017 (46.9 arcsec)
catalog_search_parameters->brightest_mag= 1.00
catalog_search_parameters->faintest_mag= 13.50
catalog_search_parameters->search_radius_second_step_deg 0.010413 (37.5 arcsec)
ITERATION 01 -- talking to VizieR, this might be slow!
UCAC5 search strategy: trying local copy first
Found a local copy of UCAC5
Reading UCAC5 zone files...
Searching UCAC5 zones 532 to 588 (Dec 16.5 to 27.3)
Done reading UCAC5 zone files...
Matched 950 stars with the local copy of UCAC5.
The local UCAC5 search seems to be a success
Correcting the measured astrometric positions...
Accuracy estimation diagnostic: 950 matched stars entering correct_measured_positions(), 939 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.50"
Removing outliers...
Correcting the measured astrometric positions...
Accuracy estimation diagnostic: 950 matched stars entering correct_measured_positions(), 34643 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.46"
ITERATION 02 -- talking to VizieR, this might be slow!
UCAC5 search strategy: trying local copy first
Found a local copy of UCAC5
Reading UCAC5 zone files...
Searching UCAC5 zones 532 to 588 (Dec 16.5 to 27.3)
Done reading UCAC5 zone files...
Matched 950 stars with the local copy of UCAC5.
The local UCAC5 search seems to be a success
Accuracy estimation diagnostic: 949 matched stars entering correct_measured_positions(), 34641 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.46"
Accuracy estimation diagnostic: 949 matched stars entering correct_measured_positions(), 34635 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.46"
Excluding outliers - 949 stars left (next iteration limit 1045)
Stop iterations.
The field is successfully solved and matched with the astrometric catalog! :)
WCS_QUALITY_DIAG: file=fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits N_match=949 sigma_overall_arcsec=0.505 sigma_q1_arcsec=0.390 sigma_q2_arcsec=0.590 sigma_q3_arcsec=0.436 sigma_q4_arcsec=0.546 n_q1=206 n_q2=265 n_q3=187 n_q4=291 worst_quadrant_to_overall_ratio=1.170
The image catalog is written to wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits.cat.ucac5
The DS9 region file with the matched stars is written to wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits.cat.ds9.reg
You may view it with the command:
ds9 /data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits -region wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits.cat.ds9.reg
The astrometric residuals vector field is written to wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits.cat.astrometric_residuals
Option '-n' not using photometric catalogs, just stick with astrometry
opt '-i': 2 is the maximum number of iterations
############ /tmp/tmp.DCFbNK8ByH (6) ############
Parsing command line arguments...
The minor axis of the CCD chip should be 24.0 mm based on the derived pixel size of 3.8 um
Internal estimated FoV 605.3'
The guess is based on the FOCALLEN keyword.
Trying to blindly solve the plate (local solve-field or remote server)...
/data_ssd/NMW-TexasTech/workdir/vast_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/util/wcs_image_calibration.sh /data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits 605.0
Entering WCS image calibration mode.
ORIGINAL_FITSFILE=/data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits
FITSFILE before on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits
FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits
verification OK: /data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits
It's not one of the telescopes that are know to produce images with good WCS solutions - will try to re-solve!
FITSFILE after on_the_fly=/data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits
WCS_IMAGE_NAME=wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits
WCS-calibrated image found: wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits
Checking if the catalog wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits.cat corresponding to the image wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits alredy exist and is non-empty...
Catalog wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits.cat corresponding to the image wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits found.
The catalog is in the new format, as expected.
The plate-solved (WCS-calibrated) image is saved to wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits
util/solve_plate_with_UCAC5 is preparing to read a catalog corresponding to the image /data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits
WCS catalog name: wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits.cat
SExtractor catalog parsing summary: zero_flux=7, no_flux_err=0, no_mag=0, no_mag_err=0, low_SNR=13, blended=1829, passed=35416
Got 35416 stars (including 33540 good ones) from the SExtractor catalog wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits.cat
util/solve_plate_with_UCAC5 got 35416 stars from the SExtractor catalog
Updated FoV from the plate-solved image: 937.3'
Seting catalog search parameters based on the expected field of view 937.3 arcmin
UCAC5 catalog search parameters:
catalog_search_parameters->search_radius_deg= 0.013018 (46.9 arcsec)
catalog_search_parameters->brightest_mag= 1.00
catalog_search_parameters->faintest_mag= 13.50
catalog_search_parameters->search_radius_second_step_deg 0.010414 (37.5 arcsec)
ITERATION 01 -- talking to VizieR, this might be slow!
UCAC5 search strategy: trying local copy first
Found a local copy of UCAC5
Reading UCAC5 zone files...
Searching UCAC5 zones 532 to 588 (Dec 16.5 to 27.3)
Done reading UCAC5 zone files...
Matched 951 stars with the local copy of UCAC5.
The local UCAC5 search seems to be a success
Correcting the measured astrometric positions...
Accuracy estimation diagnostic: 951 matched stars entering correct_measured_positions(), 939 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.51"
Removing outliers...
Correcting the measured astrometric positions...
Accuracy estimation diagnostic: 951 matched stars entering correct_measured_positions(), 34929 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.49"
ITERATION 02 -- talking to VizieR, this might be slow!
UCAC5 search strategy: trying local copy first
Found a local copy of UCAC5
Reading UCAC5 zone files...
Searching UCAC5 zones 532 to 588 (Dec 16.5 to 27.3)
Done reading UCAC5 zone files...
Matched 951 stars with the local copy of UCAC5.
The local UCAC5 search seems to be a success
Accuracy estimation diagnostic: 950 matched stars entering correct_measured_positions(), 34930 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.49"
Accuracy estimation diagnostic: 950 matched stars entering correct_measured_positions(), 34918 with non-zero local correction accuracy
Estimated accuracy of the plate solution: 0.49"
Excluding outliers - 950 stars left (next iteration limit 1046)
Stop iterations.
The field is successfully solved and matched with the astrometric catalog! :)
WCS_QUALITY_DIAG: file=fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits N_match=950 sigma_overall_arcsec=0.525 sigma_q1_arcsec=0.394 sigma_q2_arcsec=0.582 sigma_q3_arcsec=0.456 sigma_q4_arcsec=0.573 n_q1=209 n_q2=259 n_q3=184 n_q4=298 worst_quadrant_to_overall_ratio=1.107
The image catalog is written to wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits.cat.ucac5
The DS9 region file with the matched stars is written to wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits.cat.ds9.reg
You may view it with the command:
ds9 /data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits -region wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits.cat.ds9.reg
The astrometric residuals vector field is written to wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits.cat.astrometric_residuals
Option '-n' not using photometric catalogs, just stick with astrometry
opt '-i': 2 is the maximum number of iterations
Skipping WCS quality comparison: not the first SExtractor pass (default.sex.telephoto_lens_vSTL)
Copying WCS-calibrated images back to input directory
Saving fully-calibrated image wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits
INFO: FPACK_FULLY_CALIBRATED_IMAGE=no (not compressing the image)
The destination file is already there - not rewriting /data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-33-37_20.00sec_4.90C_LIGHT_0070.fits
Saving fully-calibrated image wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits
INFO: FPACK_FULLY_CALIBRATED_IMAGE=no (not compressing the image)
The destination file is already there - not rewriting /data_ssd/NMW-TexasTech/workdir//img_2026-05-19_CI_Cnc-03-Q2b1x1_223715_TTUQ2b1x1_3398606_mSqzTgXH/wcs_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071.fits
Preparing the HTML report for the field Cnc-03-Q2b1x1 with default.sex.telephoto_lens_vSTL
Forced photometry on wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits at 09:32:28.53 +23:03:11.6: 13.38 +/- 0.03 detection
Forced photometry on wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits at 09:16:31.15 +18:06:21.1: 14.21 +/- 0.06 detection
Forced photometry on wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits at 09:16:31.15 +18:06:21.1: 14.24 +/- 0.06 detection
Forced photometry on wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits at 09:32:28.53 +23:03:11.6: 13.38 +/- 0.03 detection
Forced photometry reference-image weighted average: 13.38 +/- 0.02
Forced photometry reference-image weighted average: 14.22 +/- 0.04
Forced photometry filter REJECTED candidate at 09:32:28.53 +23:03:11.6: ref_mag=13.38 +/- 0.02 new_mean_mag=13.8464 delta=-0.47 (need > 0.90)
Forced photometry filter REJECTED candidate at 09:16:31.15 +18:06:21.1: ref_mag=14.22 +/- 0.04 new_mean_mag=14.3090 delta=-0.08 (need > 0.90)
Forced photometry on wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits at 09:13:08.23 +21:40:03.9: 13.57 +/- 0.03 detection
Forced photometry on wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits at 08:55:38.64 +19:59:31.5: 13.97 +/- 0.06 detection
Forced photometry on wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits at 09:13:08.23 +21:40:03.9: 13.70 +/- 0.03 detection
Forced photometry reference-image weighted average: 13.63 +/- 0.02
Forced photometry filter REJECTED candidate at 09:13:08.23 +21:40:03.9: ref_mag=13.63 +/- 0.02 new_mean_mag=13.9515 delta=-0.32 (need > 0.90)
Forced photometry on wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits at 09:07:22.68 +24:49:57.3: 14.65 +/- 0.10 detection
Forced photometry on wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits at 08:55:38.64 +19:59:31.5: 14.10 +/- 0.06 detection
Forced photometry reference-image weighted average: 14.03 +/- 0.04
Forced photometry filter REJECTED candidate at 08:55:38.64 +19:59:31.5: ref_mag=14.03 +/- 0.04 new_mean_mag=14.2348 delta=-0.20 (need > 0.90)
Forced photometry on wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits at 09:07:22.68 +24:49:57.3: 14.56 +/- 0.09 detection
Forced photometry reference-image weighted average: 14.60 +/- 0.07
Forced photometry filter REJECTED candidate at 09:07:22.68 +24:49:57.3: ref_mag=14.60 +/- 0.07 new_mean_mag=14.3411 delta=0.26 (need > 0.90)
Forced photometry on wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits at 09:22:00.85 +23:19:46.4: 14.57 +/- 0.08 detection
Forced photometry on wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits at 09:18:44.72 +22:06:58.5: 14.48 +/- 0.07 detection
Forced photometry on wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits at 09:24:58.32 +21:07:42.8: 15.11 +/- 0.14 detection
Forced photometry on wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits at 09:18:43.83 +18:02:53.3: 16.15 +/- 99.00 upperlimit
Forced photometry on wcs_Cnc-03-Q2b1x1_2026-02-21_23-13-17_20.00sec_-15.00C_LIGHT_0200.fits at 09:07:38.43 +24:43:34.2: 14.29 +/- 0.06 detection
Forced photometry on wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits at 09:22:00.85 +23:19:46.4: 14.84 +/- 0.10 detection
Forced photometry reference-image weighted average: 14.68 +/- 0.06
Forced photometry filter REJECTED candidate at 09:22:00.85 +23:19:46.4: ref_mag=14.68 +/- 0.06 new_mean_mag=14.5240 delta=0.15 (need > 0.90)
Forced photometry on wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits at 09:18:44.72 +22:06:58.5: 14.57 +/- 0.07 detection
Forced photometry reference-image weighted average: 14.53 +/- 0.05
Forced photometry filter REJECTED candidate at 09:18:44.72 +22:06:58.5: ref_mag=14.53 +/- 0.05 new_mean_mag=14.6893 delta=-0.16 (need > 0.90)
Forced photometry on wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits at 09:18:43.83 +18:02:53.3: 16.24 +/- 99.00 upperlimit
Forced photometry on wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits at 09:24:58.32 +21:07:42.8: 15.05 +/- 0.12 detection
Forced photometry reference-image weighted average: 15.08 +/- 0.09
Forced photometry filter REJECTED candidate at 09:24:58.32 +21:07:42.8: ref_mag=15.08 +/- 0.09 new_mean_mag=14.7136 delta=0.37 (need > 0.90)
Forced photometry on wcs_Cnc-03-Q2b1x1_2026-02-22_00-05-05_20.00sec_-14.90C_LIGHT_0202.fits at 09:07:38.43 +24:43:34.2: 14.37 +/- 0.07 detection
Forced photometry reference-image weighted average: 14.33 +/- 0.04
Forced photometry filter REJECTED candidate at 09:07:38.43 +24:43:34.2: ref_mag=14.33 +/- 0.04 new_mean_mag=14.7347 delta=-0.41 (need > 0.90)
Adding exclusion_list_local.txt__out72792.dat to exclusion_list_local.txt
make_report_in_HTML.sh Phase 1 (network queries): 7s
Pre-generating preview images in parallel...
Done pre-generating preview images.
Pre-generating finding charts in parallel...
Done pre-generating finding charts.
make_report_in_HTML.sh Pre-generation: 1s
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 71933_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 71933_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate due to large distance (9.6") between the two second-epoch detections
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 71935_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 71935_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 71946_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 71946_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 71947_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 71947_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
**** FOUND 09:28:01.32 +23:18:11.1 in the exclusion list exclusion_list.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 71949_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 71949_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
**** FOUND 09:17:55.49 +20:03:06.6 in the exclusion list exclusion_list.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 71951_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 71951_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
**** FOUND 09:07:19.40 +19:49:17.6 in the exclusion list exclusion_list.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 71987_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 71987_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
**** FOUND 09:16:47.32 +17:53:44.2 in the exclusion list exclusion_list_local.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72004_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72004_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate due to large distance (9.9") between the two second-epoch detections
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72050_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72050_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
**** FOUND 09:09:54.00 +25:12:43.0 in the exclusion list exclusion_list.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72066_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72066_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate due to large distance (9.8") between the two second-epoch detections
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72076_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72076_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate due to large distance (9.8") between the two second-epoch detections
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72089_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72089_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate due to large distance (9.5") between the two second-epoch detections
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72092_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72092_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
**** FOUND 09:05:00.98 +22:48:39.3 in the exclusion list exclusion_list.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72122_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72122_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate due to large distance (9.7") between the two second-epoch detections
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72124_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72124_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate due to large distance (10.0") between the two second-epoch detections
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72127_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72127_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate due to large distance (9.8") between the two second-epoch detections
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72142_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72142_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate due to large distance (10.1") between the two second-epoch detections
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72147_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72147_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
**** FOUND 09:16:16.55 +23:25:03.4 in the exclusion list exclusion_list.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72157_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72157_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate due to large distance (9.7") between the two second-epoch detections
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72167_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72167_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate due to large distance (9.8") between the two second-epoch detections
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72182_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72182_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate due to large distance (10.0") between the two second-epoch detections
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72197_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72197_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
**** FOUND 09:12:48.03 +20:01:54.5 in the exclusion list exclusion_list.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72214_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72214_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate due to large distance (9.6") between the two second-epoch detections
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72215_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72215_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate due to large distance (10.0") between the two second-epoch detections
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72221_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72221_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate due to large distance (10.0") between the two second-epoch detections
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72250_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72250_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72255_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72255_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate due to large distance (9.7") between the two second-epoch detections
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72260_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72260_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate due to large distance (9.9") between the two second-epoch detections
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72266_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72266_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate due to large distance (9.9") between the two second-epoch detections
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72270_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72270_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate due to large distance (9.9") between the two second-epoch detections
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72295_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72295_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
**** FOUND 09:15:26.95 +23:46:01.1 in the exclusion list exclusion_list.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72306_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72306_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate due to large distance (10.2") between the two second-epoch detections
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72327_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72327_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate due to large distance (9.7") between the two second-epoch detections
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72342_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72342_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate due to large distance (9.8") between the two second-epoch detections
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72364_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72364_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate due to large distance (9.7") between the two second-epoch detections
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72368_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72368_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72380_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72380_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate due to large distance (9.6") between the two second-epoch detections
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72393_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72393_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate due to large distance (10.0") between the two second-epoch detections
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72416_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72416_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
**** FOUND 09:13:43.90 +21:02:53.0 in the exclusion list exclusion_list.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72478_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72478_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate due to large distance (9.6") between the two second-epoch detections
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72479_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72479_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
**** FOUND 09:23:03.18 +19:09:24.2 in the exclusion list exclusion_list.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72533_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72533_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate due to large distance (9.8") between the two second-epoch detections
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72543_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72543_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate due to large distance (10.1") between the two second-epoch detections
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72581_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72581_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72582_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72582_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate due to large distance (9.8") between the two second-epoch detections
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72638_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72638_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate due to large distance (10.2") between the two second-epoch detections
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72665_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72665_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
**** FOUND 09:21:20.53 +19:25:27.6 in the exclusion list exclusion_list.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72685_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72685_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate due to large distance (9.6") between the two second-epoch detections
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72704_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72704_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate due to large distance (9.5") between the two second-epoch detections
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72740_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72740_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate due to large distance (9.7") between the two second-epoch detections
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72750_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72750_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate due to large distance (9.6") between the two second-epoch detections
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72754_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72754_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate due to large distance (10.1") between the two second-epoch detections
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72756_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72756_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate due to large distance (9.5") between the two second-epoch detections
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72758_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72758_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate due to large distance (10.3") between the two second-epoch detections
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72760_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72760_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72763_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72763_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72769_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72769_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate due to large distance (10.1") between the two second-epoch detections
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72772_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72772_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate due to large distance (10.0") between the two second-epoch detections
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72789_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72789_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72791_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72791_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate due to large distance (9.8") between the two second-epoch detections
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72792_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
Preparing report for the candidate 72792_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72811_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72811_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72819_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72819_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate due to large distance (12.3") between the two second-epoch detections
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72832_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72832_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate due to large distance (9.3") between the two second-epoch detections
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72834_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72834_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate as there is no shift in pixel position (shift 0.1 pix) between the two second-epoch detections and REQUIRE_PIX_SHIFT_BETWEEN_IMAGES_FOR_TRANSIENT_CANDIDATES is set to 'yes'
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72841_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72841_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate due to large distance (12.1") between the two second-epoch detections
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72845_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72845_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate due to large distance (10.5") between the two second-epoch detections
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72855_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72855_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate due to large distance (9.6") between the two second-epoch detections
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 72860_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 72860_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
Rejecting candidate as there is no shift in pixel position (shift 0.3 pix) between the two second-epoch detections and REQUIRE_PIX_SHIFT_BETWEEN_IMAGES_FOR_TRANSIENT_CANDIDATES is set to 'yes'
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 70699_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 70699_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
**** FOUND 09:15:05.26 +19:17:38.1 in the exclusion list exclusion_list.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 13384_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 13384_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
**** FOUND 09:13:31.88 +19:34:23.2 in the exclusion list exclusion_list.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 09233_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 09233_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
**** FOUND 09:03:15.96 +18:35:22.2 in the exclusion list exclusion_list.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 06078_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 06078_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks
**** FOUND 09:01:03.29 +17:53:55.5 in the exclusion list exclusion_list.txt ****
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Considering the candidate 22575_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071
The candidate 22575_fd_Cnc-03-Q2b1x1_2026-05-19_22-34-14_20.00sec_5.00C_LIGHT_0071 did not pass the final checks